969 resultados para protection mechanisms


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Online social networking has become one of the most popular Internet applications in the modern era. They have given the Internet users, access to information that other Internet based applications are unable to. Although many of the popular online social networking web sites are focused towards entertainment purposes, sharing information can benefit the healthcare industry in terms of both efficiency and effectiveness. But the capability to share personal information; the factor which has made online social networks so popular, is itself a major obstacle when considering information security and privacy aspects. Healthcare can benefit from online social networking if they are implemented such that sensitive patient information can be safeguarded from ill exposure. But in an industry such as healthcare where the availability of information is crucial for better decision making, information must be made available to the appropriate parties when they require it. Hence the traditional mechanisms for information security and privacy protection may not be suitable for healthcare. In this paper we propose a solution to privacy enhancement in online healthcare social networks through the use of an information accountability mechanism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discusses the control and protection of a microgrid that is connected to utility through back-to-back converters. The back-to-back converter connection facilitates bidirectional power flow between the utility and the microgrid. These converters can operate in two different modes–one in which a fixed amount of power is drawn from the utility and the other in which the microgrid power shortfall is supplied by the utility. In the case of a fault in the utility or microgrid side, the protection system should act not only to clear the fault but also to block the back-to-back converters such that its dc bus voltage does not fall during fault. Furthermore, a converter internal mechanism prevents it from supplying high current during a fault and this complicates the operation of a protection system. To overcome this, an admittance based relay scheme is proposed, which has an inverse time characteristic based on measured admittance of the line. The proposed protection and control schemes are able to ensure reliable operation of the microgrid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A recent report delivered by the Australian Centre for Child Protection has highlighted the need for empirical evidence of effective pedagogies for supporting teaching and learning of child protection content in Australian teacher education programs (Arnold & Maio-Taddeo, 2007). This paper advances this call by presenting case study accounts of different approaches to teaching child protection content in University-based teacher education programs across three Australian States. These different cases provide a basis for understanding existing strategies as an important precursor to improving practice. Although preschool, primary and secondary schools have been involved in efforts to protect children from abuse and neglect since the 1970s, teacher education programs, including preservice and inservice programs, have been slow to align their work with child protection agendas. This paper opens a long-overdue discussion about the extent and nature of child protection content in teacher education and proposes strategies for translating research into practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Teachers have a crucial role as “sentinels” for children who have been abused or neglected. This professional development session will provide a framework for understanding the types, incidence and causes of child abuse and neglect, and teachers’ role in reporting suspected cases. The session will provide participants with knowledge and skills to enable them to identify warning signs and indicators of child abuse and neglect, know the basis of their duties to report suspected cases of abuse and neglect, and respond to the needs of abused and neglected children at school. The presentation will focus on: • the reasons why child abuse and neglect can occur; • the different types of child abuse and neglect and their effects on children; • the warning signs and indicators of physical abuse, emotional abuse, sexual abuse and neglect; • applying knowledge of indicators to make judgements about risk of harm; • responding to indications of risk of harm, including complying with legislative and policy-based duties to report suspected child abuse and neglect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Section 366 of the Property Agents and Motor Dealers Act 2000 (Qld) (‘PAMDA’) mandates that all contracts for the sale of residential property in Queensland (other than contracts formed on a sale by auction) have a warning statement ‘attached’ as the first or top sheet. Alternative judicial views have emerged concerning the possibility of attaching a warning statement to a contract sent by facsimile. In recognition of the consumer protection nature of the legislation, in MP Management (Aust) Pty Ltd v Churven [2002] QSC 320 Muir J favoured a restrictive view of the word ‘attached’ requiring physical joinder of the warning statement to the relevant contract. In contrast, in MNM Developments Pty Ltd v Gerrard [2005] QDC 10 Newton DCJ opined that the requirements of the PAMDA could be met where the warning statement preceded the contract of sale in a facsimile transmission sent in one continuous stream. Newton DCJ considered that this broader approach promoted commercial convenience. In an appeal from the decision of Newton DCJ, in MNM Developments Pty Ltd v Gerrard [2005] QCA 230 a majority of the Queensland Court of Appeal has held that the restrictive view propounded by Muir J is correct. Notwithstanding possible commercial inconvenience, it is not possible for a warning statement to be attached to a contract sent by facsimile.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Extraterritorial processing schemes are designed to prevent and deter access to statutory and judicial safeguards in the country responsible for the interception and transfer of asylum seekers to a third country. In line with this objective, they incorporate interdiction, transfer and processing practices and standards that are deliberately isolated from the national legal and institutional protections within either the intercepting state or the third country where processing occurs. Australia's recent disbandment of its extraterritorial processing centres in third countries highlights the fact that extraterritorial processing schemes have proven unworkable as a matter of international law, as they negate the national safeguards fundamental to the satisfaction of a state's protection obligations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of vaccines to combat pathogens that infect across mucosal surfaces has been a major goal of vaccine research. Successful mucosal vaccination requires the co-administration of adjuvants that can overcome the state of immune tolerance normally associated with mucosal application of proteins. In the case of oral immunization, delivery systems are also required to protect vaccine antigens against destruction by gastric pH and digestive enzymes. Furthermore, adjuvants used for mucosal delivery must be free of neurotoxic effects like those induced by the commonly used experimental mucosal adjuvant cholera toxin. Maintenance of the "cold chain" is also essential for the effectiveness of any vaccine and adjuvants/delivery systems that enhance the stability of a vaccine would offer a significant advantage. Needle-free methods of vaccination that induce protective immunity at multiple mucosal surfaces are also desirable for rapid vaccination of large populations. In the present study we show that transcutaneous immunization (TCI) using Lipid C, a novel lipid-based matrix originally developed for oral immunization, containing soluble Helicobacter sonicate significantly reduces the gastric bacterial burden in mice following gastric challenge with live Helicobacter pylori. Protection is associated with the production of splenic gamma interferon and gastric IgA and was achieved without the co-administration of potent and potentially toxic adjuvants, although protection was further enhanced by inclusion of CpG-ODN and cholera toxin in the lipid delivery system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nationally, there is much legislation regulating land sale transactions, particularly in relation to seller disclosure of information. The statutes require strict compliance by a seller failing which, in general, a buyer can terminate the contract. In a number of instances, when buyers have sought to exercise these rights, sellers have alleged that buyers have either expressly or by conduct waived their rights to rely upon these statutes. This article examines the nature of these rights in this context, whether they are capable of waiver and, if so, what words or conduct might be sufficient to amount to waiver. The analysis finds that the law is in a very unsatisfactory state, that the operation of those rules that can be identified as having relevance are unevenly applied and concludes that sellers have, in the main, been unsuccessful in defeating buyers' statutory rights as a result of an alleged waiver by those buyers.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the rapid increase in electrical energy demand, power generation in the form of distributed generation is becoming more important. However, the connections of distributed generators (DGs) to a distribution network or a microgrid can create several protection issues. The protection of these networks using protective devices based only on current is a challenging task due to the change in fault current levels and fault current direction. The isolation of a faulted segment from such networks will be difficult if converter interfaced DGs are connected as these DGs limit their output currents during the fault. Furthermore, if DG sources are intermittent, the current sensing protective relays are difficult to set since fault current changes with time depending on the availability of DG sources. The system restoration after a fault occurs is also a challenging protection issue in a converter interfaced DG connected distribution network or a microgrid. Usually, all the DGs will be disconnected immediately after a fault in the network. The safety of personnel and equipment of the distribution network, reclosing with DGs and arc extinction are the major reasons for these DG disconnections. In this thesis, an inverse time admittance (ITA) relay is proposed to protect a distribution network or a microgrid which has several converter interfaced DG connections. The ITA relay is capable of detecting faults and isolating a faulted segment from the network, allowing unfaulted segments to operate either in grid connected or islanded mode operations. The relay does not make the tripping decision based on only the fault current. It also uses the voltage at the relay location. Therefore, the ITA relay can be used effectively in a DG connected network in which fault current level is low or fault current level changes with time. Different case studies are considered to evaluate the performance of the ITA relays in comparison to some of the existing protection schemes. The relay performance is evaluated in different types of distribution networks: radial, the IEEE 34 node test feeder and a mesh network. The results are validated through PSCAD simulations and MATLAB calculations. Several experimental tests are carried out to validate the numerical results in a laboratory test feeder by implementing the ITA relay in LabVIEW. Furthermore, a novel control strategy based on fold back current control is proposed for a converter interfaced DG to overcome the problems associated with the system restoration. The control strategy enables the self extinction of arc if the fault is a temporary arc fault. This also helps in self system restoration if DG capacity is sufficient to supply the load. The coordination with reclosers without disconnecting the DGs from the network is discussed. This results in increased reliability in the network by reduction of customer outages.