958 resultados para precision leaching
Resumo:
Today electronic portal imaging devices (EPID's) are used primarily to verify patient positioning. They have, however, also the potential as 2D-dosimeters and could be used as such for transit dosimetry or dose reconstruction. It has been proven that such devices, especially liquid filled ionization chambers, have a stable dose response relationship which can be described in terms of the physical properties of the EPID and the pulsed linac radiation. For absolute dosimetry however, an accurate method of calibration to an absolute dose is needed. In this work, we concentrate on calibration against dose in a homogeneous water phantom. Using a Monte Carlo model of the detector we calculated dose spread kernels in units of absolute dose per incident energy fluence and compared them to calculated dose spread kernels in water at different depths. The energy of the incident pencil beams varied between 0.5 and 18 MeV. At the depth of dose maximum in water for a 6 MV beam (1.5 cm) and for a 18 MV beam (3.0 cm) we observed large absolute differences between water and detector dose above an incident energy of 4 MeV but only small relative differences in the most frequent energy range of the beam energy spectra. It is shown that for a 6 MV beam the absolute reference dose measured at 1.5 cm water depth differs from the absolute detector dose by 3.8%. At depth 1.2 cm in water, however, the relative dose differences are almost constant between 2 and 6 MeV. The effects of changes in the energy spectrum of the beam on the dose responses in water and in the detector are also investigated. We show that differences larger than 2% can occur for different beam qualities of the incident photon beam behind water slabs of different thicknesses. It is therefore concluded that for high-precision dosimetry such effects have to be taken into account. Nevertheless, the precise information about the dose response of the detector provided in this Monte Carlo study forms the basis of extracting directly the basic radiometric quantities photon fluence and photon energy fluence from the detector's signal using a deconvolution algorithm. The results are therefore promising for future application in absolute transit dosimetry and absolute dose reconstruction.
Resumo:
Range estimation is the core of many positioning systems such as radar, and Wireless Local Positioning Systems (WLPS). The estimation of range is achieved by estimating Time-of-Arrival (TOA). TOA represents the signal propagation delay between a transmitter and a receiver. Thus, error in TOA estimation causes degradation in range estimation performance. In wireless environments, noise, multipath, and limited bandwidth reduce TOA estimation performance. TOA estimation algorithms that are designed for wireless environments aim to improve the TOA estimation performance by mitigating the effect of closely spaced paths in practical (positive) signal-to-noise ratio (SNR) regions. Limited bandwidth avoids the discrimination of closely spaced paths. This reduces TOA estimation performance. TOA estimation methods are evaluated as a function of SNR, bandwidth, and the number of reflections in multipath wireless environments, as well as their complexity. In this research, a TOA estimation technique based on Blind signal Separation (BSS) is proposed. This frequency domain method estimates TOA in wireless multipath environments for a given signal bandwidth. The structure of the proposed technique is presented and its complexity and performance are theoretically evaluated. It is depicted that the proposed method is not sensitive to SNR, number of reflections, and bandwidth. In general, as bandwidth increases, TOA estimation performance improves. However, spectrum is the most valuable resource in wireless systems and usually a large portion of spectrum to support high performance TOA estimation is not available. In addition, the radio frequency (RF) components of wideband systems suffer from high cost and complexity. Thus, a novel, multiband positioning structure is proposed. The proposed technique uses the available (non-contiguous) bands to support high performance TOA estimation. This system incorporates the capabilities of cognitive radio (CR) systems to sense the available spectrum (also called white spaces) and to incorporate white spaces for high-performance localization. First, contiguous bands that are divided into several non-equal, narrow sub-bands that possess the same SNR are concatenated to attain an accuracy corresponding to the equivalent full band. Two radio architectures are proposed and investigated: the signal is transmitted over available spectrum either simultaneously (parallel concatenation) or sequentially (serial concatenation). Low complexity radio designs that handle the concatenation process sequentially and in parallel are introduced. Different TOA estimation algorithms that are applicable to multiband scenarios are studied and their performance is theoretically evaluated and compared to simulations. Next, the results are extended to non-contiguous, non-equal sub-bands with the same SNR. These are more realistic assumptions in practical systems. The performance and complexity of the proposed technique is investigated as well. This study’s results show that selecting bandwidth, center frequency, and SNR levels for each sub-band can adapt positioning accuracy.
Resumo:
Sulphide ores of copper are insoluble in dilute sulphuric acid leaching solutions, but a very high extraction can be obtained if the copper ore is in the oxidized condition. The problem is to convert the sulphide into the oxide form. This can be done by giving the sulphide ore an oxidizing-sulphatizing roast. Copper sulphate is soluble in water, so acid will be saved in the leaching process if copper sulphate is present. The iron in the copper sulphide ores is present as pyrite, or in combinations as bornite, or chalcopyrite.
Resumo:
Electrolytic iron as deposited is brittle and therefore must be annealed. After annealing, the material is ductile and closely resembles copper in its behavior under work. It is claimed to be more resistant to corrosion than dead soft iron. It also has the advantage of corroding uniformly ( ordinary soft iron develops pin holes which shorten its life considerably). The extreme purity of electrolytic iron namely makes it very suitable as a base metal for alloys. Its ductility opens up a field for use in the manufacture of cold rolled strip, seamless tubes, and wire.
Resumo:
The history of mining in Butte is woven about three of our principal metals. The gold placers first attracted the attention of miners in 1863, and reached their peak production in 1867. Silver was the second metal mined, and this operation required the erection of large mills with a consequent increase in mining activity that made the district a prominent producer. Although the presence of copper in the silver ore had been known, the credit for the first development of the copper veins is due Senator W. A. Clark. The original Colusa, Mining Chief, and Gambetta claims were developed to 1872. The ore was freighted by wagon trains 400 miles to Corrine, Utah, thence by rail eastward, some of it going to Swansea, Wales. The cooper production of the "richest hill on earth" has mounted to ten billion pounds.
Resumo:
The aim of this research was to investigate the possibilities of roasting and leaching a bulk copper-zinc sulfide concentrate, and the subsequent separation of the metals from the leach solution by electrolytic deposition.
Resumo:
It is the purpose of this investigation to obtain some insight into optimum conditions for leaching Stibnite with sodium hydroxide solution and also to steady the factors affecting the electrolysis of the resulting solution.
Resumo:
With the increasing importance of manganese in the metallurgical fields of today and tomorrow, extensive work along the lines of its successful exploitation has been accomplished by many investigators. Since tie current world situation has shut off most of our supply of high-grade manganese ores from foreign sources, the low-grade domestic deposits have entered the fields of investigation very rapidly.
Resumo:
The United States, although the leading consumer of chromite, depends almost entirely on imports for its supply. Domestic production of chromite is limited, because high-grade imported ore is plentiful and inexpensive in normal times. There are several large deposits of chromite in the United States, representing millions of tons of low grade ore. These deposits form a strategic reserve that must be used in time of national emergency.
Resumo:
Although there are many uses for manganese today, none of them approaches its importance as a deoxidizing agent in the manufacture of steels. Without manganese the steelmaking industry would be very seriously handicapped. The metallurgy of manganese has been developed around the high-grade ores, and unfortunately, our reserves of high-grade ores are very limited.
Resumo:
Chromite is the most important ore used for the production of chromium and chromium alloys. At present, the domestic production is insignificant as compared with the amount of chromite consumed in the United States.
Resumo:
The purpose of this investigation is to determine the effect of the factors listed previously by conducting a series of tests that will indicate the extent to which the purification is influenced by time, temperature, zinc oust size, zinc dust quantity, iron concentration, two stage precipitation, and aeration.
Resumo:
During the past decade microbeam radiation therapy has evolved from preclinical studies to a stage in which clinical trials can be planned, using spatially fractionated, highly collimated and high intensity beams like those generated at the x-ray ID17 beamline of the European Synchrotron Radiation Facility. The production of such microbeams typically between 25 and 100 microm full width at half maximum (FWHM) values and 100-400 microm center-to-center (c-t-c) spacings requires a multislit collimator either with fixed or adjustable microbeam width. The mechanical regularity of such devices is the most important property required to produce an array of identical microbeams. That ensures treatment reproducibility and reliable use of Monte Carlo-based treatment planning systems. New high precision wire cutting techniques allow the fabrication of these collimators made of tungsten carbide. We present a variable slit width collimator as well as a single slit device with a fixed setting of 50 microm FWHM and 400 microm c-t-c, both able to cover irradiation fields of 50 mm width, deemed to meet clinical requirements. Important improvements have reduced the standard deviation of 5.5 microm to less than 1 microm for a nominal FWHM value of 25 microm. The specifications of both devices, the methods used to measure these characteristics, and the results are presented.