891 resultados para on-line analysis of milk


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A high performance liquid chromatography (HPLC) method for extraction and determination of pesticides from raw milk was developed. The method involves direct injection of raw milk samples on a bovine serum albumin-dimethyl-octyl-silica gel (BSA-Si-Cs) column. The mobile phase 0.05 mol.L-1 phosphate buffer pH6.0 in acetonitrile (70:30 v/v) was employed for extraction and separation of bendiocarb, methylparathion, pentachlorophenol, and methomyl pesticides. The method shows good results of recovery in the pesticides studied, higher than 99.6%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and rapid procedure for extraction and separation from aldrin, DDT, endrin, heptachloro- and methoxychloro-organochlorine pesticides in raw milk has been developed by direct injection into an HPLC system without pretreatment of the samples, using an ISRP column.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An automated on-line solid phase extraction procedure followed by liquid chromatography with diode array detection was investigated for the determination of different classes of pesticides in water samples containing varied amount of humic substances. The different pesticides used were: carbendazin, carbofuran, atrazine, diuron, propanil, molinate, alachlor, parathion-ethyl, diazinon, trifluralin and the degradation products deisopropylatrazine and deethylatrazine. Humic substances extracted from a Brazilian sediment were used from 5 to 80 mg/l and their influence on recoveries was evaluated in neutral and acidic media. Recoveries higher than 70% were obtained for all the pesticides, from the preconcentration of 75 mi of aqueous sample fortified at 2 ng/ml using precolumns packed with PLRP-S. Good recoveries were obtained at neutral pH for most of the analytes up to 40 mg/l of humic acid. Only at 80 mg/l the recoveries were significantly affected, both at acidic and neutral pH. The method was applied to the determination of pesticides in river water spiked at 0.1 to 1 ng/ml. Detection limits obtained for water containing 10 mg/l of humic acid were between 0.05 and 0.3 ng/ml.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A study was undertaken to evaluate Saccharonzyces cerevisiae as a substrate for the biosorption of Cr(III) and Cr(VI) aiming to the selective determination of these species in aqueous solutions. The yeast cells were covalently immobilised on controlled pore glass (CPG), packed in a minicolumn and incorporated in an on-line flow injection system. The effect of chemical and physical variables affecting the biosorption process was tested in order to select the optimal analytical conditions for the Cr retention by S. cerevisiae. Cr(III) was retained by the immobilised cells and Cr(VI) were retained by CPG. The speciation was possible by selective and sequential elution of Cr(III) with 0.05 mol L-1 HCl and 2.0 mol L-1 HNO3 for Cr(VI). The influence of some concomitant ions up to 20 mg L-1 was also tested. Quantitative determinations of Cr were carried out by means of inductively coupled plasma optical emission spectrometry (ICP OES). Preconcentration factors of 12 were achieved for Cr(III) and 5 for Cr(VI) when 1.7 mL of sample were processed reaching detection limits of 0.45 for Cr(III) and 1.5 mu g L-1 for Cr(VI). The speciation of inorganic Cr in different kinds of natural waters was performed following the proposed method. Spiked water samples were also analysed and the recoveries were in all cases between 81 and 103%. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The application of on-line C30-reversed-phase high-pressure liquid chromatography-nuclear magnetic resonance spectroscopy is described for the analysis of tetraglycosylated flavonoids in aqueous and hydroalcoholic extracts of the leaves of Maytenus aquifolium (Celastraceae). Triacontyl stationary phases showed adequate separation for on-line 1H-NMR measurements at 600 MHz and allowed the characterisation of these flavonoids by detection of both aromatic and anomeric proton signals. Copyright (C) 2000 John Wiley and Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this paper is to show a methodology to estimate the longitudinal parameters of transmission lines. The method is based on the modal analysis theory and developed from the currents and voltages measured at the sending and receiving ends of the line. Another proposal is to estimate the line impedance in function of the real-time load apparent power and power factor. The procedure is applied for a non-transposed 440 kV three-phase line. © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a procedure for the on-line process control of variables is proposed. This procedure consists of inspecting the m-th item from every m produced items and deciding, at each inspection, whether the process is out-of-control. Two sets of limits, warning (µ0 ± W) and control (µ0 ± C), are used. If the value of the monitored statistic falls beyond the control limits or if a sequence of h observations falls between the warning limits and the control limits, the production is stopped for adjustment; otherwise, production goes on. The properties of an ergodic Markov chain are used to obtain an expression for the average cost per item. The parameters (the sampling interval m, the widths of the warning, the control limits W and C(W < C), and the sequence length (h) are optimized by minimizing the cost function. A numerical example illustrates the proposed procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES Zidovudine (ZDV) is recommended for first-line antiretroviral therapy (ART) in resource-limited settings. ZDV may, however, lead to anemia and impaired immunological response. We compared CD4+ cell counts over 5 years between patients starting ART with and without ZDV in southern Africa. DESIGN Cohort study. METHODS Patients aged at least 16 years who started first-line ART in South Africa, Botswana, Zambia, or Lesotho were included. We used linear mixed-effect models to compare CD4+ cell count trajectories between patients on ZDV-containing regimens and patients on other regimens, censoring follow-up at first treatment change. Impaired immunological recovery, defined as a CD4+ cell count below 100 cells/μl at 1 year, was assessed in logistic regression. Analyses were adjusted for baseline CD4+ cell count and hemoglobin level, age, sex, type of regimen, viral load monitoring, and calendar year. RESULTS A total of 72,597 patients starting ART, including 19,758 (27.2%) on ZDV, were analyzed. Patients on ZDV had higher CD4+ cell counts (150 vs.128 cells/μl) and hemoglobin level (12.0 vs. 11.0 g/dl) at baseline, and were less likely to be women than those on other regimens. Adjusted differences in CD4+ cell counts between regimens containing and not containing ZDV were -16 cells/μl [95% confidence interval (CI) -18 to -14] at 1 year and -56 cells/μl (95% CI -59 to -52) at 5 years. Impaired immunological recovery was more likely with ZDV compared to other regimens (odds ratio 1.40, 95% CI 1.22-1.61). CONCLUSION In southern Africa, ZDV is associated with inferior immunological recovery compared to other backbones. Replacing ZDV with another nucleoside reverse transcriptase inhibitor could avoid unnecessary switches to second-line ART.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A microwave-based thermal nebulizer (MWTN) has been employed for the first time as on-line preconcentration device in inductively coupled plasma atomic emission spectrometry (ICP-AES). By the appropriate selection of the experimental conditions, the MWTN could be either operated as a conventional thermal nebulizer or as on-line analyte preconcentration and nebulization device. Thus, when operating at microwave power values above 100 W and highly concentrated alcohol solutions, the amount of energy per solvent mass liquid unit (EMR) is high enough to completely evaporate the solvent inside the system and, as a consequence, the analyte is deposited (and then preconcentrated) on the inner walls of the MWTN capillary. When reducing the EMR to the appropriate value (e.g., by reducing the microwave power at a constant sample uptake rate) the retained analyte is swept along by the liquid-gas stream and an analyte-enriched aerosol is generated and next introduced into the plasma cell. Emission signals obtained with the MWTN operating in preconcentration-nebulization mode improved when increasing preconcentration time and sample uptake rate as well as when decreasing the nozzle inner diameter. When running with pure ethanol solution at its optimum experimental conditions, the MWTN in preconcentration-nebulization mode afforded limits of detection up to one order of magnitude lowers than those obtained operating the MWTN exclusively as a nebulizer. To validate the method, the multi-element analysis (i.e. Al, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na, Pb and Zn) of different commercial spirit samples in ICP-AES has been performed. Analyte recoveries for all the elements studied ranged between 93% and 107% and the dynamic linear range covered up to 4 orders of magnitude (i.e. from 0.1 to 1000 μg L−1). In these analysis, both MWTN operating modes afforded similar results. Nevertheless, the preconcentration-nebulization mode permits to determine a higher number of analytes due to its higher detection capabilities.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Structural analysis in handwritten mathematical expressions focuses on interpreting the recognized symbols using geometrical information such as relative sizes and positions of the symbols. Most existing approaches rely on hand-crafted grammar rules to identify semantic relationships among the recognized mathematical symbols. They could easily fail when writing errors occurred. Moreover, they assume the availability of the whole mathematical expression before being able to analyze the semantic information of the expression. To tackle these problems, we propose a progressive structural analysis (PSA) approach for dynamic recognition of handwritten mathematical expressions. The proposed PSA approach is able to provide analysis result immediately after each written input symbol. This has an advantage that users are able to detect any recognition errors immediately and correct only the mis-recognized symbols rather than the whole expression. Experiments conducted on 57 most commonly used mathematical expressions have shown that the PSA approach is able to achieve very good performance results.