945 resultados para normal-mode analysis


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mode characteristics for equilateral triangles, squares, and hexagonal resonators with a center hole are numerically simulated by the finite-different time domain (FDTD) technique. The center hole does not break the symmetry behavior of the original resonators and can result in modification of the mode field patterns and mode Q factors. In an equilateral triangle resonator the center hole can suppress the symmetry state of degenerate states with the merit of single mode operation. In a square resonator, the Q factor can be enhanced for some modes with a suitable size of the hole. For a hexagonal resonator with a side length of 1 mu m and a refractive index of 3.2, the mode Q factors first gradually decrease with the increase of the hole diameter for modes at a wavelength of about 1500 nm, then the modes transform to that of a microdisk with a jump of the mode wavelength as the hole diameter approaches 0.7 mu m. Finally, the mode Q factors greatly enhance as the hole diameter reaches about 1 mu m. The results indicate that the center hole can greatly modify mode characteristics, especially that of the mode Q factor. (C) 2009 Optical Society of America

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The influence of imperfect boundaries on the mode quality factor is investigated for equilateral-triangle-resonator (ETR) semiconductor microlasers by the finite difference time domain technique and the Pade approximation with Baker's algorithm. For 2-D ETR with a refractive index of 3.2 and side length of 5 mum, the confined modes can still have a quality factor of about 1000 as small triangles with side length of 1 mum are cut from the vertices of the ETR. For a deformed 5 mum ETR with round vertices and curve sides, the simulated mode quality factors are comparable to the measured results.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mode characteristics for two-dimensional equilateral-polygonal microresonators are investigated based on symmetry analysis and finite-difference time-domain numerical simulation. The symmetries of the resonators can be described by the point group C-Nv, accordingly, the confined modes in these resonators can be classified into irreducible representations of the point group C-Nv. Compared with circular resonators, the modes in equilateral-polygonal resonators have different characteristics due to the break of symmetries, such as the split of double-degenerate modes, high field intensity in the center region, and anomalous traveling-wave modes, which should be considered in the designs of the polygonal resonator microlasers or optical add-drop filters.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An add-drop filter based on a perfect square resonator can realize a maximum of only 25% power dropping because the confined modes are standing-wave modes. By means of mode coupling between two modes with inverse symmetry properties, a traveling-wave-like filtering response is obtained in a two-dimensional single square cavity filter with cut or circular corners by finite-difference time-domain simulation. The optimized deformation parameters for an add-drop filter can be accurately predicted as the overlapping point of the two coupling modes in an isolated deformed square cavity. More than 80% power dropping can be obtained in a deformed square cavity filter with a side length of 3.01 mu m. The free spectral region is decided by the mode spacing between modes, with the sum of the mode indices differing by 1. (c) 2007 Optical Society of America.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Quality factor enhancement due to mode coupling is observed in a three-dimensional microdisk resonator. The microdisk, which is vertically sandwiched between air and a substrate, with a radius of 1 mu m, a thickness of 0.2 mu m, and a refractive index of 3.4, is considered in a finite-difference time-domain (FDTD) numerical simulation. The mode quality factor of the fundamental mode HE71 decreases with an increase of the refractive index of the substrate, n(sub), from 2.0 to 3.17. However, the mode quality factor of the first-order mode HE72 reaches a peak value at n(sub) = 2.7 because of the mode coupling between the fundamental and the first-order modes. The variation of mode field distributions due to the mode coupling is also observed. This mechanism may be used to realize high-quality-factor modes in microdisks with high-refractive-index substrates. (c) 2006 Optical Society of America.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The mode frequencies and quality factors (Q-factors) in two-dimensional (2-D) deformed square resonators are analyzed by finite-difference time-domain (FDTD) technique. The results show that the deformed square cavities with circular and cut corners have larger Q-factors than the perfect ones at certain conditions. For a square cavity with side length of 2 mu m and refractive index of 3.2, the mode Q-factor can increase 13 times as the perfect corners are replaced by a quarter of circle with radius of 0.3 pm. Furthermore the blue shift with the increasing deformations is found as a result of the reduction in effective resonator area. In square cavities with periodic roughness at sidewalls which maintains the symmetry of the square, the Q-factors of the whisperin gallery (WG)-like modes are still one order of magnitude larger that those of non-WG-like modes. However, the Q-tactors of these two types of modes are of the same order in the square cavity with random roughness. We also find that the rectangular and rhombic deformation largely reduce the Q-factors with the increasing offset and cause the splitting of the doubly degenerate modes due to the breaking of certain symmetry properties.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The mode frequency and the quality factor of nanowire cavities are calculated from the intensity spectrum obtained by the finite-difference time-domain (FDTD) technique and the Pade approximation. In a free-standing nanowire cavity with dielectric constant epsilon = 6.0 and a length of 5 mu m, quality factors of 130, 159, and 151 are obtained for the HE11 modes with a wavelength around 375 nm, at cavity radius of 60, 75, and 90 nm, respectively. The corresponding quality factors reduce to 78, 94, and 86 for a nanowire cavity standing on a sapphire substrate with a refractive index of 1.8. The mode quality factors are also calculated for the TE01 and TM01 modes, and the mode reflectivities are calculated from the mode quality factors.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The eigenmode characteristics for equilateral triangle resonator (ETR) semiconductor microlasers are analysed by the finite-difference time-domain technique and the Pade approximation. The random Gaussian correlation function and sinusoidal function are used to model the side roughness of the ETR. The numerical results show that the roughness can cause the split of the degenerative modes, but the confined modes can still have a high quality factor. For the ETR with a 3 mum side length and the sinusoidal fluctuation, we can have a quality factor of 800 for the fundamental mode in the wavelength of 1500 nm, as the amplitude of roughness is 75 mn.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Bloch modes can be excited in planar array due to its periodic lateral refractive index. The power coupled into each eigenmode of the array waveguides is calculated through the overlap integrals of the input field with the eigenmode fields of the coupled infinite array waveguides projected onto the x-axis. Low losses can be obtained if the transition from the array to the free propagation region is adiabatic. Due to the finite resolution of lithographic process the gap between the waveguides will stop abruptly, however, when the waveguides come into too close together. Calculation results show that losses will occur at this discontinuity, which are dependent on the ratio of the gap between the waveguides and grating pitch and on the confinement of field in the array waveguides. Tapered waveguides and low index contrast between the core and cladding layers can lower the transmitted losses.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Modified nucleosides, formed post-transcriptionally in RNA by a number of modification enzymes, are excreted in abnormal levels in the urine of patients with malignant tumors. To test their usefulness as tumor markers, and to compare them with the conventional tumor markers, a reversed-phase high-performance liquid chromatographic (RP-HPLC) method and a factor analysis method have been used to study the excretion pattern of nucleosides of breast cancer patients. A clear cut differentiation of the breast cancer group and the healthy individuals in two clusters without overlapping was obtained. Copyright (C) 2000 John Wiley & Sons, Ltd.