843 resultados para multimodal collaboration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In severe forms of Diamond-Blackfan anemia, preimplantation genetic diagnosis (PGD) of histocompatibility leukocyte antigen-compatible embryos for enabling the next sibling in the family to be a stem-cell transplantation donor constitutes the sole lasting cure capable of terminating the enduring need for iterative transfusions. We report here an open collaboration between two renowned institutions to provide a family desiring this treatment even though they resided where the preimplantation genetic diagnosis procedure is banned.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fast-track multimodal rehabilitation after cesarean, the sum of all tricks Fast-track multimodal rehabilitation after caesarean is an interdisciplinary concept allowing an accelerated return to normal physiology. Fast-track rehabilitation combines minimising surgical trauma, regional anaesthesia and active management of pain control, minimally invasive postoperative care while promoting return to autonomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Ocular anatomy and radiation-associated toxicities provide unique challenges for external beam radiation therapy. For treatment planning, precise modeling of organs at risk and tumor volume are crucial. Development of a precise eye model and automatic adaptation of this model to patients' anatomy remain problematic because of organ shape variability. This work introduces the application of a 3-dimensional (3D) statistical shape model as a novel method for precise eye modeling for external beam radiation therapy of intraocular tumors. METHODS AND MATERIALS: Manual and automatic segmentations were compared for 17 patients, based on head computed tomography (CT) volume scans. A 3D statistical shape model of the cornea, lens, and sclera as well as of the optic disc position was developed. Furthermore, an active shape model was built to enable automatic fitting of the eye model to CT slice stacks. Cross-validation was performed based on leave-one-out tests for all training shapes by measuring dice coefficients and mean segmentation errors between automatic segmentation and manual segmentation by an expert. RESULTS: Cross-validation revealed a dice similarity of 95% ± 2% for the sclera and cornea and 91% ± 2% for the lens. Overall, mean segmentation error was found to be 0.3 ± 0.1 mm. Average segmentation time was 14 ± 2 s on a standard personal computer. CONCLUSIONS: Our results show that the solution presented outperforms state-of-the-art methods in terms of accuracy, reliability, and robustness. Moreover, the eye model shape as well as its variability is learned from a training set rather than by making shape assumptions (eg, as with the spherical or elliptical model). Therefore, the model appears to be capable of modeling nonspherically and nonelliptically shaped eyes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors have developed a live-cell multimodality microscope combining epifluorescence with digital holographic microscopy; it has been implemented with a decoupling procedure allowing to separately measure from the quantitative phase important cell parameters including absolute volume, shape and integral intracellular refractive index. In combination with the numerous different specific fluorescent cellular probes, this multimodality microscopy can address important issues in cell biology. This is demonstrated by the study of intracellular calcium homeostasis associated with the change in cell volume, which play a critical role in the excitotoxicity-induced neuronal death.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fondements : La recherche sur l'oedème postopératoire consécutif à la chirurgie prothétique du genou est peu développée, notamment en raison de l'absence d'une méthode de mesure adaptée. Une collaboration entre physiothérapeutes et ingénieurs a permis de développer et valider une méthode de mesure innovante et facilement applicable. Les physiothérapeutes ont identifié un besoin clinique, les ingénieurs ont apporté leur savoir technologique, et l'équipe a conjointement élaboré le protocole de mesure et effectué l'étude de validation. Introduction : La bioimpédance est fréquemment utilisée pour évaluer l'oedème par l'analyse d'un signal électrique passant au travers du corps, en extrapolant la résistance théorique à une fréquence égale à zéro (R0). La mesure s'avère fiable et rapide, mais n'a jamais été appliquée et validée pour l'évaluation de l'oedème en chirurgie orthopédique. Objectif : L'objectif de l'étude est de valider la mesure de l'oedème du membre inférieur par bioimpédance, chez des patients ayant bénéficié d'une prothèse totale de genou (PTG). Questionnement : Après nous être assurés de l'absence d'influence de l'implant métallique de la PTG sur la mesure, nous nous questionnions sur la validité et la fiabilité des mesures de bioimpédance dans ce contexte. Méthodes : Deux évaluateurs ont mesuré à tour de rôle et à deux reprises successives l'oedème chez 24 patients opérés d'une PTG, à trois temps différents (préopératoire, J+2, J+8). L'oedème a été évalué par bioimpédance (R0) et par conversion en volume de mesures centimétriques du membre inférieur (MI). Nous avons calculé le ratio moyen des MI pour chaque méthode. Nous avons évalué la reproductibilité intra- et inter-observateurs de la bioimpédance (coefficient de corrélation intraclasse, CCI) et la corrélation entre méthodes (Spearman). Résultats : Le ratio moyen opéré/sain du volume des MI est de 1.04 (SD ± 0.06) en préopératoire, 1.18 (SD ± 0.09) à J+2 et 1.17 (SD ± 0.10) à J+8. Le ratio sain/opéré des MI de R0 est de 1.04 (SD ± 0.07) en préopératoire, 1.51 (SD ± 0.22) à J+2 et 1.65 (SD ± 0.21) à J+8. En préopératoire, à J+2 et J+8, les CCI tous supérieurs à 0.95 pour la reproductibilité intra- et inter-observateurs de la bioimpédance. La corrélation entre méthodes est de 0.71 en préopératoire, 0.61 à J2 et 0.33 à J8. Analyse et conclusion : La variation du ratio des MI entre les temps préopératoire, J+2 et J+8 est plus marquée pour R0. La mesure de bioimpédance bénéficie d'une excellente reproductibilité intra- et inter-observateurs. L'évolution dans le temps de la corrélation entre méthodes peut être expliquée par l'influence potentielle de facteurs confondants sur R0 (modification de la composition liquidienne) et par l'influence de l'atrophie musculaire postopératoire sur la mesure de volume. La collaboration physiothérapeutes-ingénieurs a permis le développement et l'évaluation d'une nouvelle méthode de mesure.

Relevância:

20.00% 20.00%

Publicador: