986 resultados para mitral valve regurgitation


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Transcatheter aortic valve replacement (TAVR) has been established as a less invasive alternative to open-heart surgery in inoperable or high-risk patients presenting with symptomatic severe aortic valve stenosis. The feasibility and efficacy of valve-in-valve implantation in degenerated surgical aortic bioprostheses have also been described and can currently be considered a valuable treatment option in patients deemed unsuitable for repeat cardiac surgery. However, the clinical use of TAVR devices is not limited to the treatment of the tricuspid stenotic aortic valve. Several additional indications including treatment of the bicuspid stenotic aortic valve, aortic regurgitation, and valve-in-valve or valve-in-ring implantation in the mitral or tricuspid position as well as treatment of pure mitral, tricuspid, or pulmonary regurgitation have been described. The purpose of the present review is to summarize the available evidence concerning the emerging off-label use of TAVR devices in current clinical practice. Case examples have been selected to highlight the main procedural steps of each particular intervention.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study sought the ability of strain rate imaging to detect subclinical left ventricular dysfunction, as evidenced by reduced contractile reserve (CR) in 32 asymptomatic patients with isolated severe mitral regurgitation. Compared with CR- patients (n = 10), CR+ patients (n = 22) had significantly higher end-systolic strain and peak systolic strain rate, but these parameters were not significantly different between CR+ patients and matched normal controls. (C) 2004 by Excerpta Medica, Inc.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: Mitral repair is increasingly performed in asymptomatic mitral regurgitation (MR). Previous work showed that pre-operative documentation of loss of contractile reserve (Cr) by exercise echo (ExE) may predict LV dysfunction early after repair. We sought the value of Cr in predicting late post-op LV dysfunction and clinical outcome. Methods: Pre-op ExE was performed in 41 pts with isolated MR without coronary disease undergoing repair. LV end-systolic and end-diastolic volumes were measured at rest and post-stress and EF was calculated using modified Simpson’s rule. Intact Cr was defined by >4% increment of stress compared with rest EF. During follow up (3±1 years), EF was serially assessed and occurrence of cardiac events was documented. Results: Cr was present in 19 pts (Cr+)(peak EF 76±7%) and absent in 22 pts (Cr-)(peak EF 56±11%, p

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introdution: The transcatheter aortic valve implantation in the treatment of high-risk symptomatic aortic stenosis has increased the number of implants every year. The learning curve for transcatheter aortic valve implantation has improved since the last 12 years, allowing access alternatives. The aim of this study is to approach the implantation of transcatheter aortic valve through transaortic via associated with off-pump cardiopulmonary bypass surgery in a 67-year-old man, with chronic obstructive pulmonary disease, arterial hypertension and kidney transplant. Off-pump coronary artery bypass surgery was performed and the valve in the aortic position was released successfully. There were no complications in the intraoperative and postoperative period. Gradient reduction, effective orifice increasing of the prosthesis and absence of valvular regurgitation after implantation were observed by transesophageal echocardiography. Procedural success demonstrates that implantation of transcatheter aortic valve through the ascending aorta associated with coronary artery bypass surgery without CPB is a new option for these patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

N-Acetylglucosamine (GlcNAc) is the major immunoepitope of group A streptococcal cell wall carbohydrates. Antistreptococcal antibodies cross-reactive with anti-GlcNAc and laminin are present in sera of patients with rheumatic fever. The cross-reactivity of these antibodies with human heart valvular endothelium and the underlying basement membrane has been suggested to be a possible cause of immune-mediated valve lesion. Mannose-binding lectin (MBL) encoded by the MBL2 gene, a soluble pathogen recognition receptor, has high affinity for GlcNAc. We postulated that mutations in exon 1 of the MBL2 gene associated with a deficient serum level of MBL may contribute to chronic severe aortic regurgitation (AR) of rheumatic etiology. We studied 90 patients with severe chronic AR of rheumatic etiology and 281 healthy controls (HC) for the variants of the MBL2 gene at codons 52, 54, and 57 by using a PCR-restriction fragment length polymorphism-based method. We observed a significant difference in the prevalence of defective MBL2 alleles between patients with chronic severe AR and HC. Sixteen percent of patients with chronic severe AR were homozygotes or compound heterozygotes for defective MBL alleles in contrast to 5% for HC (P = 0.0022; odds ratio, 3.5 [ 95% confidence interval, 1.6 to 7.7]). No association was detected with the variant of the MASP2 gene. Our study suggests that MBL deficiency may contribute to the development of chronic severe AR of rheumatic etiology.