984 resultados para mitral stenosis
Resumo:
In our study, 60 infants and children, each with a severe subglottic stenosis (SGS), underwent partial cricotracheal resection (PCTR) with primary thyrotracheal anastomosis. According to the Myer-Cotton classification, two were grade II, 41 were grade III and 17 were grade IV stenoses. Of the 60 patients, 57 (95%) are presently decannulated, and one patient sustained a complete restenosis. Two patients with better than 80% subglottic airways still are waiting for decannulation: one because of bilateral cricoarytenoid joint fixation and the second because of temporary stenting of the subglottis with a Montgomery T-tube. The rate of decannulation is 97% (36 of 37 cases) in primary PCTRs, 100% (13 of 13 cases) in salvage PCTRs for failed laryngotracheal reconstructions (LTR) and 70% (7 of 10 cases) in extended PCTRs (i.e., PCTR associated with an additional open-airway procedure).
Resumo:
This article evaluates the results of portal vein (PV) stent placement in patients with malignant extrinsic lesions stenosing or obstructing the PV and causing symptomatic PV hypertension (PVHT). Fourteen patients with bile duct cancer (n = 7), pancreatic adenocarcinoma (n = 4), or another cancer (n = 3) underwent percutaneous transhepatic portal venous stent placement because of gastroesophageal or jejunal varices (n = 9), ascites (n = 7), and/or thrombocytopenia (n = 2). Concurrent tumoral obstruction of the main bile duct was treated via the transhepatic route in the same session in four patients. Changes in portal venous pressure, complications, stent patency, and survival were evaluated. Mean +/- standard deviation (SD) gradient of portal venous pressure decreased significantly immediately after stent placement from 11.2 mmHg +/- 4.6 to 1.1 mmHg +/- 1.0 (P < 0.00001). Three patients had minor complications, and one developed a liver abscess. During a mean +/- SD follow-up of 134.4 +/- 123.3 days, portal stents remained patent in 11 patients (78.6%); stent occlusion occurred in 3 patients, 2 of whom had undergone previous major hepatectomy. After stent placement, PVHT symptoms were relieved in four (57.1%) of seven patients who died (mean survival, 97 +/- 71.2 days), and relieved in six (85.7%) of seven patients still alive at the end of follow-up (mean follow-up, 171.7 +/- 153.5 days). Stent placement in the PV is feasible and relatively safe. It helped to relieve PVHT symptoms in a single session.
Resumo:
STUDY DESIGN: Prospective neurophysiological study. OBJECTIVE: To identify and quantify the neurophysiological effects of interspinous distraction during spine surgery for lumbar spinal stenosis (LSS). SUMMARY OF BACKGROUND DATA: Interspinous devices have been introduced as an alternative treatment of LSS in selected patients aiming at obtaining indirect decompression. Nevertheless, there is no data on the immediate neurophysiological effect of distraction. METHODS: Thirty patients with LSS undergoing decompression (14 at single level, 16 at multiple levels) were enrolled, resulting in a total of 48 levels to be analyzed. Before decompression, calibrated incremental distraction simulating interspinous device implantation of 8, 10, 12, 14, and 16 mm was performed. Intraoperative motor evoked potentials were acquired before any distraction, during distraction at each incremental value and after bilateral decompression. We evaluated relative changes of motor evoked potentials normalized to hand muscles and related them to the number of affected levels, LSS radiological severity based on the A to D grading, lordosis, and disc height. RESULTS: For single-level disease, 8-mm distraction and open decompression yielded similar improvement in motor evoked potentials not only in levels with morphological grades A or B, but also in levels with morphological grades C or D (i.e., severe or extreme stenosis) (P = 0.32). In contrast, distraction superior to 8 mm was less effective (P ≤ 0.05). In multiple-level stenosis, decompression was significantly more effective than any degree of distraction (P < 0.001). No correlation of those results to disc height or lordosis was observed. Using χ trend test to analyze the effect of distraction, a linear trend favoring moderate over severe stenotic morphology was observed (P = 0.0349). CONCLUSION: Interspinous distraction of 8 mm is sufficient to replicate electrophysiological improvements obtained during full decompression even in severe single-level stenosis but not in multilevel disease. Interspinous distraction has therefore an immediately measurable neurophysiological effect. Level of Evidence: 4.
Resumo:
In the western world, the carotid-artery stenosis is one of the major causes of ischemic stroke in elderly people. The principal therapeutic indication is a symptomatic stenosis > 50% in the first two weeks and the surgical approach has shown the best results. Despite inferior results to carotid endarterectomy in terms of post-operative rate of stroke and/or death, except for young patients, carotid stenting remains the best choice in patients at high surgical risk. The best medical treatment, consisting in correction of cardiovascular risk factors, statin therapy and anti-aggregation led to a drastic reduction in the annual rate of stroke associated to carotid stenosis and thus limited the surgical intervention in asymptomatic patient to men with a life expectancy of at least 5 years and a stenosis > 70%.
Resumo:
BACKGROUND/AIMS: The present report examines a new pig model for progressive induction of high-grade stenosis, for the study of chronic myocardial ischemia and the dynamics of collateral vessel growth. METHODS: Thirty-nine Landrace pigs were instrumented with a novel experimental stent (GVD stent) in the left anterior descending coronary artery. Eight animals underwent transthoracic echocardiography at rest and under low-dose dobutamine. Seven animals were examined by nuclear PET and SPECT analysis. Epi-, mid- and endocardial fibrosis and the numbers of arterial vessels were examined by histology. RESULTS: Functional analysis showed a significant decrease in global left ventricular ejection fraction (24.5 +/- 1.6%) 3 weeks after implantation. There was a trend to increased left ventricular ejection fraction after low-dose dobutamine stress (36.0 +/- 6.6%) and a significant improvement of the impaired regional anterior wall motion. PET and SPECT imaging documented chronic hibernation. Myocardial fibrosis increased significantly in the ischemic area with a gradient from epi- to endocardial. The number of arterial vessels in the ischemic area increased and coronary angiography showed abundant collateral vessels of Rentrop class 1. CONCLUSION: The presented experimental model mimics the clinical situation of chronic myocardial ischemia secondary to 1-vessel coronary disease.
Resumo:
BACKGROUND: Diastolic dysfunction with delayed relaxation and abnormal passive elastic properties has been described in patients with severe pressure overload hypertrophy. The purpose of this study was to evaluate the time course of rotational motion of the left ventricle in patients with aortic valve stenosis using myocardial tagging. METHODS: Myocardial tagging is a non-invasive method based on magnetic resonance which makes it possible to label ('tag') specific myocardial regions. From the motion of the tag's cardiac rotation, radial displacement and translational motion can be determined. In 12 controls and 13 patients with severe aortic valve stenosis systolic and diastolic wall motion was assessed in an apical and basal short axis plane. RESULTS: The normal left ventricle performs a systolic wringing motion around the ventricular long axis with clockwise rotation at the base (-4.4+/-1.6 degrees) and counter-clockwise rotation at the apex (+6.8+/-2.5 degrees) when viewed from the apex. During early diastole an untwisting motion can be observed which precedes diastolic filling. In patients with aortic valve stenosis systolic rotation is reduced at the base (-2.4+/-2.0 degrees; P<0.01) but increased at the apex (+12.0+/-6.0 degrees; P<0.05). Diastolic untwisting is delayed and prolonged with a decrease in normalized rotation velocity (-6.9+/-1.1 s(-1)) when compared to controls (-10.7+/-2.2 s(-1); P<0.001). Maximal systolic torsion is 8.0+/-2.1 degrees in controls and 14.1+/-6.4 degrees (P<0.01) in patients with aortic valve stenosis. CONCLUSIONS: Left ventricular pressure overload hypertrophy is associated with a reduction in basal and an increase in apical rotation resulting in increased torsion of the ventricle. Diastolic untwisting is delayed and prolonged. This may explain the occurrence of diastolic dysfunction in patients with severe pressure overload hypertrophy.
Resumo:
PRINCIPLES: Cardiac myxoma is the most commonly diagnosed cardiac tumour. Infection of herpes simplex virus 1 (HSV1) has been postulated to be a factor for this pathologic entity. The aim of the current study was to evaluate the association between HSV 1 and myxoma occurrence.METHODS: Between 1965 and 2005, 70 patients (36 female, mean age: 52.6 years) underwent a resection of myxoma. Selected variables such as hospital mortality and morbidity were studied. A follow-up (FU; mean FU time: 138 +/- 83 months) was obtained (76% complete). Immunohistological studies with monoclonal antibodies against HSV type 1 were performed on tumour biopsies of 40 patients.RESULTS: The mean age was 53 +/- 16 years (range 23 to 84 years, 51% female). Of the investigated population, 31 (44%) were in New York Heart Association (NYHA) class III-IV. Mitral valve stenosis was identified in 14 patients (20%), and in 25 (36%) patients mitral valve was insufficient. During hospitalisation 3 patients suffered from a transient neurological disorder, and in addition to myxoma resection 18 (25.7%) patients had to undergo an additional intervention. The overall survival rate was 91% at 40 years. There was no early postoperative mortality in follow-up, although 4 patients died and 2 patients had been re-operated on for recurrent myxomas after 2 and 9 years. Immunohistology revealed no positive signals for HSV-1 antigens among the 40 analysed cases.CONCLUSION: Complete surgical resection, septum included, was the treatment of choice and mandatory to prevent relapse. Peri-operative morbidity and mortality over 40 years remained low, and no association between HSV infection and occurrence of cardiac myxoma was found.
Resumo:
The purpose of this study was to assess the safety and efficacy of stenting in upper airway reconstructions for benign laryngotracheal stenosis (LTS) with a newly designed prosthesis, the LT-Mold?. The LT-Mold and its proper use during open surgery and endoscopy are described, and the experience gathered from a prospectively collected database on 65 patients treated for complex LTS or severe aspiration is reported. This series is compared to the results of other stenting methods. All patients were available for evaluation. In all but one case, the prosthesis was removed at the end of the study. The new prosthesis did not induce any stent-related trauma to the supraglottis, glottis and subglottis. Before adding a distal round-shaped silicone cap to the LT-Mold, granulation tissue was usually seen at the stent-mucosal interface at the tracheostoma level. In 14 cases, there has been a spontaneous extrusion of the prosthesis through the mouth; this problem was solved by fixing the prosthesis through the reinforced portion of the prosthesis at the cap level and by adding one fixation stitch in the supraglottis. We have to document the loss of the silicone cap in three cases. This problem was resolved by designing a new prototype with an integrated cap, glued with a slow hardening silicone glue. Fifty-four (83 %) of 65 patients were decannulated after a mean duration of stenting of 3 months (range 1-12 months). The mean follow-up after decannulation was 23 months (range 1 month to 10 years). The experience gathered with the LT-Mold shows that long-term stenting for complex LTS is safely achieved when the prosthesis is used with its distal integrated silicone cap. The softness and smoothness of the prosthesis with a round-shaped configuration of both extremities help avoid ulceration and granulation tissue formation in the reconstructed airway. Adequate fixation is mandatory to avoid extrusion.
Resumo:
Renin angiotensin system (RAS) blockers are generally considered as contraindicated when an atheromatous renal artery stenosis (ARAS) is diagnosed. The main reason is the fear of inducing renal ischemia and, hence, accelerating renal fibrosis and the progression towards end stage renal disease, albeit RAS blocker have been shown to be highly effective in controlling blood pressure. Part of the solution came by the development of the revascularization. There is now growing evidence showing no superiority of angioplasty over medical treatment on cardiovascular events and mortality, renal function and blood pressure control. Hence, RAS blockers resurfaced based on their proven beneficial effects on blood pressure control and cardiovascular prevention in high risk atherosclerotic patients. Thus, RAS blockers belong today to the standard treatment of hypertensive patients with ARAS. However they were not systematically prescribed in trials focusing on ARAS. The ongoing CORAL trial will give us further information on the place of this class of antihypertensive drugs in patients with ARAS.
Resumo:
In some high-risk patients, standard mitral valve replacement can represent a challenging procedure, requiring a risky extensive decalcification of the annulus. In particular, high-risk redo patients and patients with a previously implanted transcatheter aortic valve, who develop calcific mitral disease, would benefit from the development of new, minimally invasive, transcatheter or hybrid techniques for mitral valve replacement. In particular, mixing transcatheter valve therapies and well-established minimally invasive techniques for mitral replacement or repair can help in decreasing the surgical risk and the technical complexity. Thus, placing transcatheter, balloon-expandable Sapien? XT stent-valves in calcified, degenerated mitral valves through a right thoracotomy, a left atriotomy and on an on-pump fibrillating heart, represents an attractive alternative to standard surgery in redo patients, in patients with concomitant transcatheter aortic stent-valves in place and in patients with a high-risk profile. We describe this hybrid technique in detail.
Resumo:
Biomarkers of blood lipid modification and oxidative stress have been associated with increased cardiovascular morbidity. We sought to determine whether these biomarkers were related to functional indices of stenosis severity among patients with stable coronary artery disease. We studied 197 consecutive patients with stable coronary artery disease due to single vessel disease. Fractional flow reserve (FFR) ≤ 0.80 was assessed as index of a functionally significant lesion. Serum levels of secretory phospholipase A2 (sPLA2) activity, secretory phospholipase A2 type IIA (sPLA2-IIA), myeloperoxydase (MPO), lipoprotein-associated phospholipase A2 (Lp-PLA2), and oxidized low-density lipoprotein (OxLDL) were assessed using commercially available assays. Patients with FFR > 0.8 had higher sPLA2 activity, sPLA2 IIA, and OxLDL levels than patients with FFR ≤ 0.8 (21.25 [16.03-27.28] vs 25.85 [20.58-34.63] U/mL, p < 0.001, 2.0 [1.5-3.4] vs 2.6 [2.0-3.4] ng/mL, p < 0.01; and 53.0 [36.0-71.0] vs 64.5 [50-89.25], p < 0.001 respectively). Patients with FFR > 0.80 had similar Lp-PLA2 and MPO levels versus those with FFR ≤ 0.8. sPLA2 activity, sPLA2 IIA significantly increased area under the curve over baseline characteristics to predict FFR ≤ 0.8 (0.67 to 0.77 (95 % confidence interval [CI]: 0.69-0.85) p < 0.01 and 0.67 to 0.77 (95 % CI: 0.69-0.84) p < 0.01, respectively). Serum sPLA2 activity as well as sPLA2-IIA level is related to functional characteristics of coronary stenoses in patients with stable coronary artery disease.