905 resultados para micro-
Resumo:
Aim: The aim of this study was to assess the effect of iStent (trabecular micro-bypass stent) implantation in combination with phacoemulsification on IOP and glaucoma medications and to compare this to the outcome of phacoemulsification alone. Patients and Methods: A retrospective consecutive comparative review was undertaken. 131 eyes with ocular hypertension and medically controlled glaucoma underwent phacoemulsification alone (n = 78 group I) or combined with gonioscopic-guided implantation of one iStent (n = 31, group II) or two iStents (n = 22, group III). Patients were assessed at postoperative weeks 1, 3 and 6, and months 3 and 6. Pre- and post-operative measures included visual acuity, IOP and glaucoma medications. Results: Post-operatively at 6 months, mean IOP decreased from 16.3 mmHg to 14.2 mmHg in group I (p < 0.01), from 16.7 mmHg to 15.1 mmHg in group II (p < 0.16) and from 17.0 to 13.8 in group III (p = 0.05). Mean glaucoma medication decreased from 1.9 to 1.6 in group I (8 %, p = 0.12), from 2.5 to 0.8 in group II (27 %, p = 0.04), and from 2.1 to 1.0 in group III (45 %, p < 0.01). Conclusions: iStent implantation resulted in similar IOP reduction to phacoemulsification alone but achieved a significantly greater reduction in glaucoma medications. This may improve compliance and quality of life, and reduce health care costs in patients with early to moderate glaucoma.
Resumo:
This article analyses the impact that innovation expenditure and intrasectoral and intersectoral externalities have on productivity in Spanish firms. While there is an extensive literature analysing the relationship between innovation and productivity, in this particular area there are far fewer studies that examine the importance of sectoral externalities, especially with the focus on Spain. One novelty of the study, which covers the industrial and service sectors, is that we also consider jointly the technology level of the sector in which the firm operates and the firm size. The database used is the Technological Innovation Panel, PITEC, which includes 12,813 firms for the year 2008 and has been little used in this type of study. The estimation method used is Iteratively Reweighted Least Squares method, IRLS, which is very useful for obtaining robust estimations in the presence of outliers. The results confirm that innovation has a positive effect on productivity, especially in high-tech and large firms. The impact of externalities is more heterogeneous because, while intrasectoral externalities have a poitive and significant effect, especially in low-tech firms independently of size, intersectoral externalities have a more ambiguous effect, being clearly significant for advanced industries in which size has a positive effect.
Resumo:
Regional disparities in unemployment rates are large and persistent. The literature provides evidence of their magnitude and evolution, as well as evidence of the role of certain economic, demographic and environmental factors in explaining the gap between regions of low and high unemployment. Most of these studies, however, adopt an aggregate approach and so do not account for the individual characteristics of the unemployed and employed in each region. This paper, by drawing on micro-data from the Spanish wave of the Labour Force Survey, seeks to remedy this shortcoming by analysing regional differentials in unemployment rates. An appropriate decomposition of the regional gap in the average probability of being unemployed enables us to distinguish between the contribution of differences in the regional distribution of individual characteristics from that attributable to a different impact of these characteristics on the probability of unemployment. Our results suggest that the well-documented disparities in regional unemployment are not just the result of regional heterogeneity in the distribution of individual characteristics. Non-negligible differences in the probability of unemployment remain after controlling for this type of heterogeneity, as a result of differences across regions in the impact of the observed characteristics. Among the factors considered in our analysis, regional differences in the endowment and impact of an individual’s education are shown to play a major role.
Resumo:
Diabetic macular edema (DME) is a frequent complication of diabetic retinopathy and may cause severe visual loss. In this article, we examine the pathophysiology of DME and review various treatment options, such as laser photocoagulation, anti-vascular endothelial growth factor (VEGF) receptor antibodies, and steroids including ILUVIEN(®), which is a new sustained-release, non biodegradable, injectable, intravitreal micro-implant containing fluocinolone acetonide. The results of the FAME (Fluocinolone Acetonide in Diabetic Macular Edema) studies, conducted to evaluate the efficacy and safety of ILUVIEN(®) in DME, are discussed.
Resumo:
Peer-reviewed
Resumo:
Two models of a glass micro-extractor were constructed after modification of a model proposed in the literature. The two models were used for the simultaneous extraction and enrichment of organochlorinated pesticides from aqueous matrixes to an organic solution appropriate for the gas chromatographic analysis of the pesticide. It was established that the performance of one of the modified micro-extractors permits the pre-concentration of the pesticides to a level that allow their quantitation at the trace level with electron capture detection. It is thus concluded that the glass micro-extractor is a suitable tool for the sample preparation step in the gas chromatographic analysis of environmental pollutants of the class of pesticides.
Resumo:
The technique of solid phase microextraction (SPME) was used for the extraction of halogenated contaminants of water samples from three cities of the State of São Paulo and the extracts were submitted to gas chromatographic analysis with electron capture detection (GC-ECD). In the samples of water collected at the city of São Paulo the detected level of trihalomethanes (THM) expressed as the sum of chloroform, dibromochloromethane and dichlorobromomethane, were higher than the permissible limit established by the Brazilian regulation. In the samples collected at the two other cities the level of any of the three THM remained below the sensitivity of the ECD.
Resumo:
A procedure for the nitration of phenol in a semi-micro scale, followed by separation of the formed orto- and para-nitrophenol isomers by column chromatography, is described. All the experiment, including determination of the melting point of the isolated products, require a period of 4 hours, and it is suitable for organic chemistry laboratory undergraduate courses.
Resumo:
The pyrethroids bifenthrin, permethrin, cypermethrin and deltamethrin were extracted by solid phase extraction (SPE) and solid phase microextraction (SPME). The analysis were performed on a gas chromatograph with electron capture detection (GC-ECD). Octadecil Silano-C18, Florisil and Silica stationary phases were studied for SPE. Better results were obtained for Florisil which gave recoveries from 80% to 108%. Pyrethroids extraction by SPME showed a linear response and a detection limit of 10 pg ml-1. Although the data showed that the two extraction methods were able to isolate the pesticide residues from water samples, the best results were obtained by using SPME which is more sensitive, faster, cheeper, being a more useful technique for the analysis of pyrethroids in drinking water.
Resumo:
A method for determination of lead and cadmium in aqueous samples using solvent microextraction and dithizone as complexing agent with FAAS was developed. Solvent microextraction parameters were optimized. The effect of foreign ions on the extraction yields was studied. The extraction was carried out until the aqueous to organic phase ratio achieved a 250 fold preconcentration of metals. For preconcentration times of 4 min the 3sigma detection limits, relative standard deviations (n=7) and linear calibration ranges were 1.6 mug L-1, 5.8% and 10.0 -- 80.0 mug L-1 for lead and 11.1 ng L-1, 5.9% and 0.3 -- 3.0 mug L-1 for cadmium, respectively. The solvent microextraction procedure presented here was applied to the determination of lead and cadmium in natural waters.