867 resultados para measurement and metrology
Resumo:
Respiration is a complex activity. If the relationship between all neurological and skeletomuscular interactions was perfectly understood, an accurate dynamic model of the respiratory system could be developed and the interaction between different inputs and outputs could be investigated in a straightforward fashion. Unfortunately, this is not the case and does not appear to be viable at this time. In addition, the provision of appropriate sensor signals for such a model would be a considerable invasive task. Useful quantitative information with respect to respiratory performance can be gained from non-invasive monitoring of chest and abdomen motion. Currently available devices are not well suited in application for spirometric measurement for ambulatory monitoring. A sensor matrix measurement technique is investigated to identify suitable sensing elements with which to base an upper body surface measurement device that monitors respiration. This thesis is divided into two main areas of investigation; model based and geometrical based surface plethysmography. In the first instance, chapter 2 deals with an array of tactile sensors that are used as progression of existing and previously investigated volumetric measurement schemes based on models of respiration. Chapter 3 details a non-model based geometrical approach to surface (and hence volumetric) profile measurement. Later sections of the thesis concentrate upon the development of a functioning prototype sensor array. To broaden the application area the study has been conducted as it would be fore a generically configured sensor array. In experimental form the system performance on group estimation compares favourably with existing system on volumetric performance. In addition provides continuous transient measurement of respiratory motion within an acceptable accuracy using approximately 20 sensing elements. Because of the potential size and complexity of the system it is possible to deploy it as a fully mobile ambulatory monitoring device, which may be used outside of the laboratory. It provides a means by which to isolate coupled physiological functions and thus allows individual contributions to be analysed separately. Thus facilitating greater understanding of respiratory physiology and diagnostic capabilities. The outcome of the study is the basis for a three-dimensional surface contour sensing system that is suitable for respiratory function monitoring and has the prospect with future development to be incorporated into a garment based clinical tool.
Resumo:
We demonstrate a new approach to in-situ measurement of femtosecond laser pulse induced changes in glass enabling the reconstruction in 3D of the induced complex permittivity modification. The technique can be used to provide single shot and time resolved quantitative measurements with a micron scale spatial resolution.
Resumo:
This thesis contributes to the paucity of marketing research into the area of internal marketing. Drawing from knowledge developed in a diverse range of marketing and management literatures, the domaill of internal marketing is clarified Gild a new concept, internal market orientation is developed. A new instrument, measuring the internal market orientation, is developed and subjected to standard scale development procedures. Six dimensions of the construct are confirmed; collegial interaction, group interaction, jorlllal interaction, external envirollment, wage flexibility and job flexibility. A sample of 766 UK retail store managers are surveyed to identify levels of internal market orientation and external market orientation in large UK multi-product, multi-site retailers and the structural relationships between internal market orientation, extemal market orientation alld company performance are examined. The external market orientation construct is applied to the local retail market and established measurement instruments adapted to this pwpose. Three measures of performance are employed ill this study. The structural relationships between the six dimensions of internal market orientation and the three dimensions of external market orientation are examined employing structural equations methodology, using LISREL 8.3. alld the impact of internal market orientation Oil external market orientation and company performance is measured. The study finds no direct link between internal market orientation and financial performance but does identify the moderated role of internal market orientation on financial performance. Significant relationships between three of the six dimensions of internal market orientation and the three dimensions of external market orientation are identified and the impact of internal market orientation on the retention of employees and their behaviour is also identified. The research findings contribute to marketing theory by providing empirical evidence to support the long held assumption that internal marketing has an impact on marketing success and offers an explanation of the mechanism by which this influence operates. For marketing practitioners, the research findings offer additional information on which services marketing strategies may be formulated.
Resumo:
Coke oven liquor is a toxic wastewater produced in large quantities by the Iron and Steel, and Coking Industries, and gives rise to major effluent treatment problems in those industries. Conscious of the potentially serious environmental impact of the discharge of such wastes, pollution control agencies in many countries have made progressively more stringent quality requirements for the discharge of the treated waste. The most common means of treating the waste is the activated sludge process. Problems with achieving consistently satisfactory treatment by this process have been experienced in the past. The need to improve the quality of the discharge of the treated waste prompted attempts by TOMLINS to model the process using Adenosine Triphosophnte (ATP) as a measure of biomass, but these were unsuccessful. This thesis describes work that was carried out to determine the significance of ATP in the activated sludge treatment of the waste. The use of ATP measurements in wastewater treatment were reviewed. Investigations were conducted into the ATP behaviour of the batch activated sludge treatment of two major components of the waste, phenol, and thiocyanate, and the continuous activated sludge treatment of the liquor itself, using laboratory scale apparatus. On the basis of these results equations were formulated to describe the significance of ATP as a measured activity and biomass in the treatment system. These were used as the basis for proposals to use ATP as a control parameter in the activated sludge treatment of coke oven liquor, and wastewaters in general. These had relevance both to the treatment of the waste in the reactor and to the settlement of the sludge produced in the secondary settlement stage of the treatment process.
Resumo:
We demonstrate a novel time-resolved Q-factor measurement technique and demonstrate its application in the analysis of optical packet switching systems with high information spectral density. For the first time, we report the time-resolved Q-factor measurement of 42.6 Gbit/s AM-PSK and DQPSK modulated packets, which were generated by a SGDBR laser under wavelength switching. The time dependent degradation of Q-factor performance during the switching transient was analyzed and was found to be correlated with different laser switching characteristics in each case.
Resumo:
Productivity at the macro level is a complex concept but also arguably the most appropriate measure of economic welfare. Currently, there is limited research available on the various approaches that can be used to measure it and especially on the relative accuracy of said approaches. This thesis has two main objectives: firstly, to detail some of the most common productivity measurement approaches and assess their accuracy under a number of conditions and secondly, to present an up-to-date application of productivity measurement and provide some guidance on selecting between sometimes conflicting productivity estimates. With regards to the first objective, the thesis provides a discussion on the issues specific to macro-level productivity measurement and on the strengths and weaknesses of the three main types of approaches available, namely index-number approaches (represented by Growth Accounting), non-parametric distance functions (DEA-based Malmquist indices) and parametric production functions (COLS- and SFA-based Malmquist indices). The accuracy of these approaches is assessed through simulation analysis, which provided some interesting findings. Probably the most important were that deterministic approaches are quite accurate even when the data is moderately noisy, that no approaches were accurate when noise was more extensive, that functional form misspecification has a severe negative effect in the accuracy of the parametric approaches and finally that increased volatility in inputs and prices from one period to the next adversely affects all approaches examined. The application was based on the EU KLEMS (2008) dataset and revealed that the different approaches do in fact result in different productivity change estimates, at least for some of the countries assessed. To assist researchers in selecting between conflicting estimates, a new, three step selection framework is proposed, based on findings of simulation analyses and established diagnostics/indicators. An application of this framework is also provided, based on the EU KLEMS dataset.
Resumo:
The purpose of this work is the development of database of the distributed information measurement and control system that implements methods of optical spectroscopy for plasma physics research and atomic collisions and provides remote access to information and hardware resources within the Intranet/Internet networks. The database is based on database management system Oracle9i. Client software was realized in Java language. The software was developed using Model View Controller architecture, which separates application data from graphical presentation components and input processing logic. The following graphical presentations were implemented: measurement of radiation spectra of beam and plasma objects, excitation function for non-elastic collisions of heavy particles and analysis of data acquired in preceding experiments. The graphical clients have the following functionality of the interaction with the database: browsing information on experiments of a certain type, searching for data with various criteria, and inserting the information about preceding experiments.
Resumo:
The development of the distributed information measurement and control system for optical spectral research of particle beam and plasma objects and the execution of laboratory works on Physics and Engineering Department of Petrozavodsk State University are described. At the hardware level the system is represented by a complex of the automated workplaces joined into computer network. The key element of the system is the communication server, which supports the multi-user mode and distributes resources among clients, monitors the system and provides secure access. Other system components are formed by equipment servers (CАМАC and GPIB servers, a server for the access to microcontrollers MCS-196 and others) and the client programs that carry out data acquisition, accumulation and processing and management of the course of the experiment as well. In this work the designed by the authors network interface is discussed. The interface provides the connection of measuring and executive devices to the distributed information measurement and control system via Ethernet. This interface allows controlling of experimental parameters by use of digital devices, monitoring of experiment parameters by polling of analog and digital sensors. The device firmware is written in assembler language and includes libraries for Ethernet-, IP-, TCP- и UDP-packets forming.
Resumo:
The present paper is devoted to creation of cryptographic data security and realization of the packet mode in the distributed information measurement and control system that implements methods of optical spectroscopy for plasma physics research and atomic collisions. This system gives a remote access to information and instrument resources within the Intranet/Internet networks. The system provides remote access to information and hardware resources for the natural sciences within the Intranet/Internet networks. The access to physical equipment is realized through the standard interface servers (PXI, CАМАC, and GPIB), the server providing access to Ethernet devices, and the communication server, which integrates the equipment servers into a uniform information system. The system is used to make research task in optical spectroscopy, as well as to support the process of education at the Department of Physics and Engineering of Petrozavodsk State University.
Resumo:
Measuring and compensating the pivot points of five-axis machine tools is always challenging and very time consuming. This paper presents a newly developed approach for automatic measurement and compensation of pivot point positional errors on five-axis machine tools. Machine rotary axis errors are measured using a circular test. This method has been tested on five-axis machine tools with swivel table configuration. Results show that up to 99% of the positional errors of the rotary axis can be compensated by using this approach.