940 resultados para low pass filter (LPF)
Resumo:
The design and manufacture of a prototype chip level power supply is described, with both simulated and experimental results. Of particular interest is the inclusion of a fully integrated on-chip LC filter. A high switching frequency of 660MHz and the design of a device drive circuit reduce losses by supply stacking, low-swing signaling and charge recycling. The paper demonstrates that a chip level converter operating at high frequency can be built and shows how this can be achieved, using zero voltage switching techniques similar to those commonly used in larger converters. Both simulations and experimental data from a fabricated circuit in 0.18μm CMOS are included. The circuit converts 2.2V to 0.75∼1.0V at ∼55mA. ©2008 IEEE.
Resumo:
The objective of this study was to examine the operating characteristics of a light duty multi cylinder compression ignition engine with regular gasoline fuel at low engine speed and load. The effects of fuel stratification by means of multiple injections as well as the sensitivity of auto-ignition and burn rate to intake pressure and temperature are presented. The measurements used in this study included gaseous emissions, filter smoke opacity and in-cylinder indicated information. It was found that stable, low emission operation was possible with raised intake manifold pressure and temperature, and that fuel stratification can lead to an increase in stability and a reduced reliance on increased temperature and pressure. It was also found that the auto-ignition delay sensitivity of gasoline to intake temperature and pressure was low within the operating window considered in this study. Nevertheless, the requirement for an increase of pressure, temperature and stratification in order to achieve auto-ignition time scales small enough for combustion in the engine was clear, using pump gasoline. Copyright © 2009 SAE International.
Resumo:
Phenotypic plasticity widely exists in the external morphology of animals as well as the internal traits of organs. In the present study, we studied the gut length plasticity of planktivorous filter-feeding silver carp under different food resources in large-net cage experiments in Meiliang Bay of Lake Taihu in 2004 and 2005. There was a significant difference in stocking density between these 2 years. Under a low stocking density and abundant food resources, silver carp increased their energy intake by feeding on more zooplankton. Meanwhile, silver carp adjusted their gut length to match the digestive requirements of food when exposed to different food resources. In the main growth seasons (from April to October), silver carp significantly increased their relative gut length when feeding on more phytoplankton in 2005 (p < 0.01, 9.23 +/- 1.80 in 2004 and 10.77 +/- 2.05 in 2005, respectively). There was a nearly significant negative correlation between zooplankton proportion in the diet and the relative gut length when silver carp were stocked in a high density (p = 0.112). It appears that silver carp might have evolved plasticity to change their gut length rapidly to facilitate efficient utilization of food resources. Such resource polymorphisms in the gut may be a good indication of temporal adaptation to resource conditions. Our work provided field evidence for understanding the functional basis of resource polymorphisms and the evolution of phenotypic plasticity in planktivorous filter-feeding fish.
Resumo:
In contrast to the relatively well documented impact of particulate-feeding fish on zooplankton communities, little attention has been devoted to the impact of filter-feeding fish. Filter-feeding silver and bighead carp are the most intensively cultured fish species in Asia and comprise much of the production of Chinese aquaculture. However, little information is known about the impact of either fish on the zooplankton community. Long-term changes in the Copepoda community (1957-1996) were studied at two sampling stations of a subtropical Chinese lake (Lake Donghu) dominated by silver and bighead carp. For both calanoids and cyclopoids, the littoral station (I) was much more resource profitable than the pelagic station (II). There has been a tremendous increase in the annual fish catch over the past 30 years due to the increased stocking with fingerlings of the two carp species. There was a notably higher fish density at Station I than at Station II. Cyclopoid abundance was notably higher at Station I than at Station II during the 1950s to the 1980s, while the reverse became true in the 1990s. This is probably because when fish abundance increased to an extremely high level, the impact of fish predation on the cyclopoids became more important than that of food resources at the littoral station. At both stations, cyclopoid abundance was relatively low in spite of the presence of abundant prey. Similarly, calanoid density did not differ significantly between the two stations in the 1950s and 1960s, but was significantly lower at Station I than at Station II during the 1980s and 1990s. Such changes are attributed to the gradient of fish predation between the stations and an increasing predation pressure by the fish. The increased fish predation also correlated with a shift in summer-dominant calanoids from larger species to smaller ones. In conclusion, the predaceous cyclopoids are affected by fish predation to a much lesser extent than the herbivorous calanoids, and therefore increased predation by filter-feeding fish results in a definite increase in the cyclopoid/calanoid ratio. Predation by filter-feeding fish has been a driving force in shaping the copepod community structure of Lake Donghu during the past decades.
Resumo:
The authors present an analysis of plasmonic wave filter and curved waveguide, simulated using a 2-D finite-difference time-domain technique. With different dielectric materials or surface structures located on the interface of the metal/dielectric, the resonant enhanced wave filter can divide light waves of different wavelengths and guide them with low losses. And the straight or curved waveguide can confine and guide light waves in a subwavelength scale. Within the 20 mu m simulation region, it is found that the intensity of the guided light at the interface is roughly four times the peak intensity of the incident light.
Resumo:
In this paper, we propose a new approach to construct a 2-dimensional (2-D) directional filter bank (DFB) by cascading a 2-D nonseparable checkerboard-shaped filter pair and 2-D separable cosine modulated filter bank (CMFB). Similar to diagonal subbands in 2-D separable wavelets, most of the subbands in 2-D separable CMFBs, tensor products of two 1-D CMFBs, are poor in directional selectivity due to the fact that the frequency supports of most of the subband filters are concentrated along two different directions. To improve the directional selectivity, we propose a new DFB to realize the subband decomposition. First, a checkerboard-shaped filter pair is used to decompose an input image into two images containing different directional information of the original image. Next, a 2-D separable CMFB is applied to each of the two images for directional decomposition. The new DFB is easy in design and has merits: low redundancy ratio and fine directional-frequency tiling. As its application, the BLS-GSM algorithm for image denoising is extended to use the new DFBs. Experimental results show that the proposed DFB achieves better denoising performance than the methods using other DFBs for images of abundant textures. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
A low-power, highly linear, multi-standard, active-RC filter with an accurate and novel tuning architec-ture is presented. It exhibits 1EEE 802. 11a/b/g (9.5 MHz) and DVB-H (3 MHz, 4 MHz) application. The filter exploits digitally-controlled polysilicon resistor banks and a phase lock loop type automatic tuning system. The novel and complex automatic frequency calibration scheme provides better than 4 comer frequency accuracy, and it can be powered down after calibration to save power and avoid digital signal interference. The filter achieves OIP3 of 26 dBm and the measured group delay variation of the receiver filter is 50 ns (WLAN mode). Its dissipation is 3.4 mA in RX mode and 2.3 mA (only for one path) in TX mode from a 2.85 V supply. The dissipation of calibration consumes 2 mA. The circuit has been fabricated in a 0.35μm 47 GHz SiGe BiCMOS technology; the receiver and transmitter filter occupy 0.21 mm~2 and 0.11 mm~2 (calibration circuit excluded), respectively.
Resumo:
Optical filters capable of single control parameter-based wide tuning are implemented and studied. A prototype surface micromachined 1.3μm Si-based MOEMS (micro-opto-electro-mechanical-systems) tunable filter exhibits a continuous and large tuning range of 90 nm at 50 V tuning voltage. The filter can be integrated with Si-based photodetector in a low-cost component for coarse wavelength division multiplexing systems operating in the 1.3μm band.
Resumo:
The ever increasing demand for broadband communications requires sophisticated devices. Photonic integrated circuits (PICs) are an approach that fulfills those requirements. PICs enable the integration of different optical modules on a single chip. Low loss fiber coupling and simplified packaging are key issues in keeping the price of PICs at a low level. Integrated spot size converters (SSC) offer an opportunity to accomplish this. Design, fabrication and characterization of SSCs based on an asymmetric twin waveguide (ATG) at a wavelength of 1.55 μm are the main elements of this dissertation. It is theoretically and experimentally shown that a passive ATG facilitates a polarization filter mechanism. A reproducible InP process guideline is developed that achieves vertical waveguides with smooth sidewalls. Birefringence and resonant coupling are used in an ATG to enable a polarization filtering and splitting mechanism. For the first time such a filter is experimentally shown. At a wavelength of 1610 nm a power extinction ratio of (1.6 ± 0.2) dB was measured for the TE- polarization in a single approximately 372 μm long TM- pass polarizer. A TE-pass polarizer with a similar length was demonstrated with a TM/TE-power extinction ratio of (0.7 ± 0.2) dB at 1610 nm. The refractive indices of two different InGaAsP compositions, required for a SSC, are measured by the reflection spectroscopy technique. A SSC layout for dielectric-free fabricated compact photodetectors is adjusted to those index values. The development and the results of the final fabrication procedure for the ATG concept are outlined. The etch rate, sidewall roughness and selectivity of a Cl2/CH4/H2 based inductively coupled plasma (ICP) etch are investigated by a design of experiment approach. The passivation effect of CH4 is illustrated for the first time. Conditions are determined for etching smooth and vertical sidewalls up to a depth of 5 μm.
Resumo:
In this thesis, the evanescent field sensing techniques of tapered optical nanofibres and microspherical resonators are investigated. This includes evanescent field spectroscopy of a silica nanofibre in a rubidium vapour; thermo-optical tuning of Er:Yb co-doped phosphate glass microspheres; optomechanical properties of microspherical pendulums; and the fabrication and characterisation of borosilicate microbubble resonators. Doppler-broadened and sub-Doppler absorption spectroscopic techniques are performed around the D2 transition (780.24 nm) of rubidium using the evanescent field produced at the waist of a tapered nanofibre with input probe powers as low as 55 nW. Doppler-broadened Zeeman shifts and a preliminary dichroic atomic vapour laser lock (DAVLL) line shape are also observed via the nanofibre waist with an applied magnetic field of 60 G. This device has the potential for laser frequency stabilisation while also studying the effects of atom-surface interactions. A non-invasive thermo-optical tuning technique of Er:Yb co-doped microspheres to specific arbitrary wavelengths is demonstrated particularly to 1294 nm and the 5S1/2F=3 to 5P3/2Fʹ=4 laser cooling transition of 85Rb. Reversible tuning ranges of up to 474 GHz and on resonance cavity timescales on the order of 100 s are reported. This procedure has prospective applications for sensing a variety of atomic or molecular species in a cavity quantum electrodynamics (QED) experiments. The mechanical characteristics of a silica microsphere pendulum with a relatively low spring constant of 10-4 Nm-1 are explored. A novel method of frequency sweeping the motion of the pendulum to determine its natural resonance frequencies while overriding its sensitivity to environmental noise is proposed. An estimated force of 0.25 N is required to actuate the pendulum by a displacement of (1-2) μm. It is suggested that this is of sufficient magnitude to be experienced between two evanescently coupled microspheres (photonic molecule) and enable spatial trapping of the micropendulum. Finally, single-input borosilicate microbubble resonators with diameters <100 μm are fabricated using a CO2 laser. Optical whispering gallery mode spectra are observed via evanescent coupling with a tapered fibre. A red-shift of (4-22) GHz of the resonance modes is detected when the hollow cavity was filled with nano-filtered water. A polarisation conversion effect, with an efficiency of 10%, is observed when the diameter of the coupling tapered fibre waist is varied. This effect is also achieved by simply varying the polarisation of the input light in the tapered fibre where the efficiency is optimised to 92%. Thus, the microbubble device acts as a reversible band-pass to band-stop optical filter for cavity-QED, integrated solid-state and semiconductor circuit applications.
Resumo:
The ability of diffuse reflectance spectroscopy to extract quantitative biological composition of tissues has been used to discern tissue types in both pre-clinical and clinical cancer studies. Typically, diffuse reflectance spectroscopy systems are designed for single-point measurements. Clinically, an imaging system would provide valuable spatial information on tissue composition. While it is feasible to build a multiplexed fiber-optic probe based spectral imaging system, these systems suffer from drawbacks with respect to cost and size. To address these we developed a compact and low cost system using a broadband light source with an 8-slot filter wheel for illumination and silicon photodiodes for detection. The spectral imaging system was tested on a set of tissue mimicking liquid phantoms which yielded an optical property extraction accuracy of 6.40 +/- 7.78% for the absorption coefficient (micro(a)) and 11.37 +/- 19.62% for the wavelength-averaged reduced scattering coefficient (micro(s)').
Resumo:
The design of a low loss quasi-optical beam splitter which is required to provide efficient diplexing of the bands 316.5-325.5 GHz and 349.5-358.5 GHz is presented. To minimise the filter insertion loss, the chosen architecture is a three-layer freestanding array of dipole slot elements. Floquet modal analysis and finite element method computer models are used to establish the geometry of the periodic structure and to predict its spectral response. Two different micromachining approaches have been employed to fabricate close packed arrays of 460 mm long elements in the screens that form the basic building block of the 30mm diameter multilayer frequency selective surface. Comparisons between simulated and measured transmission coefficients for the individual dichroic surfaces are used to determine the accuracy of the computer models and to confirm the suitability of the fabrication methods.
Resumo:
The performance of a very low loss frequency selective surface (FSS) comprising two air spaced planar arrays of linear slot elements is reported. The beamsplitter generates a low loss passband response with a very sharp transmission roll-off with frequency. Simulated and measured results in the 30 GHz and 300 GHz wavebands are used to quantify the performance improvement compared to a conventional multilayer dielectrically backed conducting ring FSS. The paper also discusses the effect of the array dimensions on the passband width and filter roll-off rate.
Resumo:
In this paper, we introduce an efficient method for particle selection in tracking objects in complex scenes. Firstly, we improve the proposal distribution function of the tracking algorithm, including current observation, reducing the cost of evaluating particles with a very low likelihood. In addition, we use a partitioned sampling approach to decompose the dynamic state in several stages. It enables to deal with high-dimensional states without an excessive computational cost. To represent the color distribution, the appearance of the tracked object is modelled by sampled pixels. Based on this representation, the probability of any observation is estimated using non-parametric techniques in color space. As a result, we obtain a Probability color Density Image (PDI) where each pixel points its membership to the target color model. In this way, the evaluation of all particles is accelerated by computing the likelihood p(z|x) using the Integral Image of the PDI.
Resumo:
Flattening filter free (FFF) linear accelerators allow for an increase in instantaneous dose-rate of the x-ray pulses by a factor of 2-6 over the conventional flattened output. As a result, radiobiological investigations are being carried out to determine the effect of these higher dose-rates on cell response. The studies reported thus far have presented conflicting results, highlighting the need for further investigation. To determine the radiobiological impact of the increased dose-rates from FFF exposures a Varian Truebeam medical linear accelerator was used to irradiate two human cancer cell lines in vitro, DU-145 prostate and H460 non-small cell lung, with both flattened and FFF 6 MV beams. The fluence profile of the FFF beam was modified using a custom-designed Nylon compensator to produce a similar dose profile to the flattened beam (6X) at the cell surface but at a higher instantaneous dose-rate. For both cell lines there appeared to be no significant change in cell survival. Curve fitting coefficients for DU145 cells irradiated with constant average dose-rates were 6X: alpha = 0.09 +/- 0.03, beta = 0.03 +/- 0.01 and 6FFF: alpha = 0.14 +/- 0.13, beta = 0.03 +/- 0.02 with a significance of p = 0.75. For H460 cells irradiated with the same instantaneous dose-rate but different average dose-rate the fit coefficients were 6FFF (low dose-rate): alpha = 0.21 +/- 0.11, 0.07 +/- 0.02 and 6FFF (high dose-rate): alpha = 0.21 +/- 0.16, 0.07 +/- 0.03, with p = 0.79. The results indicate that collective damage behaviour does not occur at the instantaneous dose-rates investigated here and that the use of either modality should result in the same clinical outcome, however this will require further validation in vivo.