997 resultados para let-7


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quinoline fused-ring system of the title compound, C11H8ClNO, is planar (r.m.s. deviation = 0.007 angstrom); the formyl group is bent slightly out of the plane [C-C-C-O torsion angles = -9.6 (5) and 170.4 (3)degrees].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Welcome to Volume 7 of Student Success. This editorial has two parts: The first part maintains the “doing things differently” tradition, making readers aware by chronicling the publishing of the journal in an open access (OA) forum. Future editorials will briefly discuss other aspects and issues pertaining to the new scholarly publishing landscape that this journal adheres to, such as: Creative Commons Licencing; ORCID IDs; considerations of new peer review models and importantly; measuring research impact in OA publishing. The second part presents the usual editorial summary of the content of this issue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

State-of-the-art image-set matching techniques typically implicitly model each image-set with a Gaussian distribution. Here, we propose to go beyond these representations and model image-sets as probability distribution functions (PDFs) using kernel density estimators. To compare and match image-sets, we exploit Csiszar´ f-divergences, which bear strong connections to the geodesic distance defined on the space of PDFs, i.e., the statistical manifold. Furthermore, we introduce valid positive definite kernels on the statistical manifold, which let us make use of more powerful classification schemes to match image-sets. Finally, we introduce a supervised dimensionality reduction technique that learns a latent space where f-divergences reflect the class labels of the data. Our experiments on diverse problems, such as video-based face recognition and dynamic texture classification, evidence the benefits of our approach over the state-of-the-art image-set matching methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polygenic profiling has been proposed for elite endurance performance, using an additive model determining the proportion of optimal alleles in endurance athletes. To investigate this model’s utility for elite triathletes, we genotyped seven polymorphisms previously associated with an endurance polygenic profile (ACE Ins/Del, ACTN3 Arg577Ter, AMPD1 Gln12Ter, CKMM 1170bp/985+185bp, HFE His63Asp, GDF8 Lys153Arg and PPARGC1A Gly482Ser) in a cohort of 196 elite athletes who participated in the 2008 Kona Ironman championship triathlon. Mean performance time (PT) was not significantly different in individual marker analysis. Age, sex, and continent of origin had a significant influence on PT and were adjusted for. Only the AMPD1 endurance-optimal Gln allele was found to be significantly associated with an improvement in PT (model p=5.79 x 10-17, AMPD1 genotype p=0.01). Individual genotypes were combined into a total genotype score (TGS); TGS distribution ranged from 28.6 to 92.9, concordant with prior studies in endurance athletes (mean±SD: 60.75±12.95). TGS distribution was shifted toward higher TGS in the top 10% of athletes, though the mean TGS was not significantly different (p=0.164) and not significantly associated with PT even when adjusted for age, sex, and origin. Receiver operating characteristic curve analysis determined that TGS alone could not significantly predict athlete finishing time with discriminating sensitivity and specificity for three outcomes (less than median PT, less than mean PT, or in the top 10%), though models with the age, sex, continent of origin, and either TGS or AMPD1 genotype could. These results suggest three things: that more sophisticated genetic models may be necessary to accurately predict athlete finishing time in endurance events; that non-genetic factors such as training are hugely influential and should be included in genetic analyses to prevent confounding; and that large collaborations may be necessary to obtain sufficient sample sizes for powerful and complex analyses of endurance performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

All non-H atoms of the title compound, C12H12ClNO, are co-planar (r.m.s. deviation = 0.055 angstrom). The hydroxy H atom is disordered over two positions of equal occupancy. In the crystal, molecules are linked by O-H center dot center dot center dot O hydrogen bonds, generating zigzag chains running along the b axis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The title compound, C24H24N2O3S, exhibits antifungal and antibacterial properties. The compound crystallizes with two molecules in the asymmetric unit, with one molecule exhibiting 'orientational disorder' in the crystal structure with respect to the cyclohexene ring. The o-toluidine groups in both molecules are noncoplanar with the respective cyclohexene-fused thiophene ring. In both molecules, there is an intramolecular N-H...N hydrogen bond forming a pseudo-six-membered ring which locks the molecular conformation and eliminates conformational flexibility. The crystal structure is stabilized by O-H...O hydrogen bonds; both molecules in the asymmetric unit form independent chains, each such chain consisting of alternating 'ordered' and 'disordered' molecules in the crystal lattice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the title compound, C17H10Br2O5, the chromene ring is almost planar with minimal puckering [total puckering amplitude = 0.067 (4) angstrom]. The dihedral angle between chromeme ring system and phenyl ring is 3.7 (2)degrees. The crystal structure is stabilized by intermolecular C-H center dot center dot center dot O interactions and an intramolecular O-H center dot center dot center dot O hydrogen bond also occurs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

γ-Y 2Si 2O 7 is a promising candidate material both for hightemperature structural applications and as an environmental/thermal barrier coating material due to its unique properties such as high melting point, machinability, thermal stability, low linear thermal expansion coefficient (3.9×10 -6/K, 200°-1300°C), and low thermal conductivity (<3.0 W/ṁK above 300°C). The hot corrosion behavior of γ-Y 2Si 2O 7 in thin-film molten Na 2SO 4 at 850°-1000°C for 20 h in flowing air was investigated using a thermogravimetric analyzer (TGA) and a mass spectrometer (MS). γ-Y 2Si 2O 7 exhibited good resistance against Na 2SO 4 molten salt. The kinetic curves were well fitted by a paralinear equation: the linear part was caused by the evaporation of Na2SO4 and the parabolic part came from gas products evolved from the hotcorrosion reaction. A thin silica film formed under the corrosion scale was the key factor for retarding the hot corrosion. The apparent activation energy for the corrosion of γ-Y 2Si 2O 7 in Na 2SO 4 molten salt with flowing air was evaluated to be 255 kJ/mol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Early studies on grain boundary sliding (GBS) in Mg alloys have suggested frequently that the contribution of GBS to creep is high even under conditions corresponding to dislocation creep. The role of creep strain and grain size in influencing the experimental measurements has not been clearly identified. Grain boundary sliding measurements were conducted in detail over experimental conditions corresponding to diffusion creep as well as dislocation creep in a single-phase Mg-0.7 wt pet Al alloy. The results indicated clearly that the GBS contribution to creep was Very high during,, diffusion creep at low stresses (similar to 75 pct) and substantially reduced during dislocation creep at high stresses (similar to 15 pct). These measurements were consistent with the observation of significant intragranular slip band activity observed in most grains at high stresses and very little slip band activity at low stresses. The experimental measurements and analysis indicated also that the GBS contribution to creep was high during the initial stages of creep and decreased to a steady-state value at large strains.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Generating a cultural lighting icon on the Manhattan skyline is a big responsibility and there is no second chance to make it right. In addition, we had to balance a classic timeless lighting design for the building while responding to the lighting criteria of the Times Square district – in a time of energy awareness...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Boron neutron capture therapy (BNCT) is a form of chemically targeted radiotherapy that utilises the high neutron capture cross-section of boron-10 isotope to achieve a preferential dose increase in the tumour. The BNCT dosimetry poses a special challenge as the radiation dose absorbed by the irradiated tissues consists of several dose different components. Dosimetry is important as the effect of the radiation on the tissue is correlated with the radiation dose. Consistent and reliable radiation dose delivery and dosimetry are thus basic requirements for radiotherapy. The international recommendations for are not directly applicable to BNCT dosimetry. The existing dosimetry guidance for BNCT provides recommendations but also calls for investigating for complementary methods for comparison and improved accuracy. In this thesis the quality assurance and stability measurements of the neutron beam monitors used in dose delivery are presented. The beam monitors were found not to be affected by the presence of a phantom in the beam and that the effect of the reactor core power distribution was less than 1%. The weekly stability test with activation detectors has been generally reproducible within the recommended tolerance value of 2%. An established toolkit for epithermal neutron beams for determination of the dose components is presented and applied in an international dosimetric intercomparison. The measured quantities (neutron flux, fast neutron and photon dose) by the groups in the intercomparison were generally in agreement within the stated uncertainties. However, the uncertainties were large, ranging from 3-30% (1 standard deviation), emphasising the importance of dosimetric intercomparisons if clinical data is to be compared between different centers. Measurements with the Exradin type 2M ionisation chamber have been repeated in the epithermal neutron beam in the same measurement configuration over the course of 10 years. The presented results exclude severe sensitivity changes to thermal neutrons that have been reported for this type of chamber. Microdosimetry and polymer gel dosimetry as complementary methods for epithermal neutron beam dosimetry are studied. For microdosimetry the comparison of results with ionisation chambers and computer simulation showed that the photon dose measured with microdosimetry was lower than with the two other methods. The disagreement was within the uncertainties. For neutron dose the simulation and microdosimetry results agreed within 10% while the ionisation chamber technique gave 10-30% lower neutron dose rates than the two other methods. The response of the BANG-3 gel was found to be linear for both photon and epithermal neutron beam irradiation. The dose distribution normalised to dose maximum measured by MAGIC polymer gel was found to agree well with the simulated result near the dose maximum while the spatial difference between measured and simulated 30% isodose line was more than 1 cm. In both the BANG-3 and MAGIC gel studies, the interpretation of the results was complicated by the presence of high-LET radiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The complexes, Ba (HQS) (H2O)(4) (HQS = 8-hydroxyquinoline-5-sulfonic acid) (1) and Ag (HIQS) (H2O) (Ferron = 7-iodo-8-hydroxyquinoline-5-sulfonic acid) (2) have been synthesized and characterized by X-ray diffraction analysis and spectroscopic studies. In compound 1, Ba2+ ion has a nine-coordinate monocapped antiprismatic geometry. In compound 2, Ag+ has distorted tetrahedral coordination and Ag center dot center dot center dot I interactions generate the supramolecular architectures. The complexes have been characterized by FT-IR and UV-Visible measurements. In both the structures, the inversion-related organic ligands are stacked over one another leading to three-dimensional networks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The irreversible ErbB family blocker afatinib and the reversible EGFR tyrosine kinase inhibitor gefitinib are approved for first-line treatment of EGFR mutation-positive non-small-cell lung cancer (NSCLC). We aimed to compare the efficacy and safety of afatinib and gefitinib in this setting. Methods This multicentre, international, open-label, exploratory, randomised controlled phase 2B trial (LUX-Lung 7) was done at 64 centres in 13 countries. Treatment-naive patients with stage IIIB or IV NSCLC and a common EGFR mutation (exon 19 deletion or Leu858Arg) were randomly assigned (1:1) to receive afatinib (40 mg per day) or gefitinib (250 mg per day) until disease progression, or beyond if deemed beneficial by the investigator. Randomisation, stratified by EGFR mutation type and status of brain metastases, was done centrally using a validated number generating system implemented via an interactive voice or web-based response system with a block size of four. Clinicians and patients were not masked to treatment allocation; independent review of tumour response was done in a blinded manner. Coprimary endpoints were progression-free survival by independent central review, time-to-treatment failure, and overall survival. Efficacy analyses were done in the intention-to-treat population and safety analyses were done in patients who received at least one dose of study drug. This ongoing study is registered with ClinicalTrials.gov, number NCT01466660. Findings Between Dec 13, 2011, and Aug 8, 2013, 319 patients were randomly assigned (160 to afatinib and 159 to gefitinib). Median follow-up was 27·3 months (IQR 15·3–33·9). Progression-free survival (median 11·0 months [95% CI 10·6–12·9] with afatinib vs 10·9 months [9·1–11·5] with gefitinib; hazard ratio [HR] 0·73 [95% CI 0·57–0·95], p=0·017) and time-to-treatment failure (median 13·7 months [95% CI 11·9–15·0] with afatinib vs 11·5 months [10·1–13·1] with gefitinib; HR 0·73 [95% CI 0·58–0·92], p=0·0073) were significantly longer with afatinib than with gefitinib. Overall survival data are not mature. The most common treatment-related grade 3 or 4 adverse events were diarrhoea (20 [13%] of 160 patients given afatinib vs two [1%] of 159 given gefitinib) and rash or acne (15 [9%] patients given afatinib vs five [3%] of those given gefitinib) and liver enzyme elevations (no patients given afatinib vs 14 [9%] of those given gefitinib). Serious treatment-related adverse events occurred in 17 (11%) patients in the afatinib group and seven (4%) in the gefitinib group. Ten (6%) patients in each group discontinued treatment due to drug-related adverse events. 15 (9%) fatal adverse events occurred in the afatinib group and ten (6%) in the gefitinib group. All but one of these deaths were considered unrelated to treatment; one patient in the gefitinib group died from drug-related hepatic and renal failure. Interpretation Afatinib significantly improved outcomes in treatment-naive patients with EGFR-mutated NSCLC compared with gefitinib, with a manageable tolerability profile. These data are potentially important for clinical decision making in this patient population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the title compound, C16H13ClN2O, the quinoline ring system is essentially planar, with a maximum deviation of 0.021 (2) angstrom. The pyridone ring is oriented at a dihedral angle of 85.93 (6)degrees with respect to the quinoline ring system. In the crystal structure, intermolecular C-H center dot center dot center dot O hydrogen bonds link the molecules along the b axis. Weak pi-pi stacking interactions [centroid-centroid distances = 3.7218 (9) and 3.6083 (9) angstrom] are also observed.