947 resultados para laser efficiency
Resumo:
Laser-driven coherent extreme-ultraviolet (XUV) sources provide pulses lasting a few hundred attoseconds(1,2), enabling real-time access to dynamic changes of the electronic structure of matter(3,4), the fastest processes outside the atomic nucleus. These pulses, however, are typically rather weak. Exploiting the ultrahigh brilliance of accelerator-based XUV sources(5) and the unique time structure of their laser-based counterparts would open intriguing opportunities in ultrafast X-ray and high-field science, extending powerful nonlinear optical and pump-probe techniques towards X-ray frequencies, and paving the way towards unequalled radiation intensities. Relativistic laser-plasma interactions have been identified as a promising approach to achieve this goal(6-13). Recent experiments confirmed that relativistically driven overdense plasmas are able to convert infrared laser light into harmonic XUV radiation with unparalleled efficiency, and demonstrated the scalability of the generation technique towards hard X-rays(14-19). Here we show that the phases of the XUV harmonics emanating from the interaction processes are synchronized, and therefore enable attosecond temporal bunching. Along with the previous findings concerning energy conversion and recent advances in high-power laser technology, our experiment demonstrates the feasibility of confining unprecedented amounts of light energy to within less than one femtosecond.
Resumo:
A new regime is described for radiation pressure acceleration of a thin foil by an intense laser beam of above 10(20) W cm(-2). Highly monoenergetic proton beams extending to giga-electron-volt energies can be produced with very high efficiency using circularly polarized light. The proton beams have a very small divergence angle (< 4 degrees). This new method allows the construction of ultra-compact proton and ion accelerators with ultra-short particle bursts.
Resumo:
Recent progress using the VULCAN laser at the Rutherford Appleton Laboratory to pump X-ray lasing in nickel-like ions is reviewed. Double pulse pumping with similar to 100 ps pulses has been shown to produce significantly greater X-ray laser output than single pulses of duration 0.1-1 ns. With double pulse pumping, the main pumping pulse interacts with a pre-formed plasma created by a pre-pulse. The efficiency of lasing increases as there is a reduced effect of refraction of the X-ray laser beam due to smaller density gradients and larger gain volumes, which enable propagation of the X-ray laser beam along the full length of the target. The record shortest wavelength saturated laser at 5.9 nm has been achieved in Ni-like dysprosium using double pulse pumping of 75 ps duration from the VULCAN laser. A variant of the double pulse pumping using a single similar to 100 ps laser pulse and a superimposed short similar to 1 ps pulse has been found to further increase the efficiency of lasing by reducing the effects of over-ionisation during the gain period. The record shortest wavelength saturated laser pumped by a short similar to 1 ps pulse has been achieved in Ni-like samarium using the VULCAN laser operating in chirped pulse amplified (CPA) mode. Ni-like samarium lases at 7.3 nm. (C) 2000 Academie des sciences/Editions scientifiques et medicales Elsevier SAS.
Resumo:
The temporal development of laser driven single mode perturbations in thin A1 foils has been measured using extreme ultraviolet (XUV) laser radiography. 15, 30, 70 and 90 mu m single modes were imprinted on 2 mu m thick A1 foils with an optical driver laser at 527 nm for intensities in the range 5 x 10(12) to 1.5 x 10(13) W cm(-2). The magnitude of the imprinted perturbation at the time of shock break out was determined by fitting to the data estimated curves of growth of the Rayleigh-Taylor instability after shock break out. The efficiency of imprinting is independent of perturbation wavelength in the parameter range of this experiment, suggesting little influence of thermal conduction smoothing. The results are of interest for directly driven inertially confined fusion. (C) 1998 American Institute of Physics.
Resumo:
We report the first demonstration of saturation in a Ni-like x-ray laser, specifically Ni-like Ag x-ray laser at 14 nm. Using high-resolution spatial imaging and angularly resolved streaking techniques, the output source size as well as the time history, divergence, energy, and spatial profile of the output beam have been fully characterized. The output intensity of the Ag laser was measured to be about 70 GWcm(-2) The narrow divergence, short pulse duration, high efficiency, and high brightness of the Ag laser make it an ideal candidate for many x-ray laser applications.
Resumo:
The current saturated operation of X-ray lasers at wavelengths > 15 nm requires at least kilojoule drive energy, which is only available at the largest laser installations in the world, Using a specially designed drive pulse configuration, saturated operation of a Ni-like Sn X-ray laser at 12 nm has been achieved with only 75 J drive energy, An efficiency as high as 9 x 10(6) in converting laser energy from the 1 eV optical spectral range to the 100 eV soft X-ray range has been reached, This paves the way for applications of saturated X-ray lasers at 12 nm at many other smaller laboratories. (C) 1997 Published by Elsevier Science B.V.
Resumo:
A saturated nickel-like samarium x-ray laser beam at 7 nanometers has been demonstrated with an output energy of 0.3 millijoule in 50-picosecond pulses, demonstrating that saturated operation of a laser at wavelengths shorter than 10 nanometers can be achieved. The narrow divergence, short wavelength, short pulse duration, high efficiency, and high brightness of this samarium laser make it an ideal candidate for many x-ray laser applications.
Resumo:
We have studied the effect of prepulses in enhancing the efficiency of generating ASE beams in soft X-ray laser plasma amplifiers based on pumping Ne-like ions, Slab targets were irradiated with a weak prepulse followed by a main plasma heating pulse of nanosecond duration, Time-integrated; time and spectrally resolved and time and angularly resolved lasing emissions on the 3p-3s (J=0-1) XUV lasing lines of Ne-like Ni, Cu and Zn at wavelengths 232 Angstrom 221 Angstrom and 212 Angstrom respectively have been monitored. Measurements were made for pre-pulse/main-pulse intensity ratios from 10(-5)-10(-1) and for pump delay times of 2 ns and 4.5 ns. Zinc is shown to exhibit a peak in output intensity at similar to 2x10(-3) pre-pulse fraction for a 4.5 ns pump delay, with a main pulse pump intensity of similar to 1.3x10(13) W cm(-2) on a 20 mm target. The Zn lasing emission had a duration of similar to 240 ps and this was insensitive to prepulse fraction. The J=0-1 XUV laser output for nickel and copper increased monotonically with prepulse fraction, with copper targets showing least sensitivity to either prepulse level or prepulse to main pulse delay. Under the conditions of the study, the pre-pulse level was observed to haveno significant influence on the output intensity of the 3p-3s (J=2-1) lines of any of the elements investigated.
Resumo:
We report on measurements of the saturated single frequency output of a Ge XXIII x-ray laser on the J=0-->1 transition at 19.6 nm from a refraction compensating double target driven by 150 J of energy from 75-ps Nd-glass laser pulses. The 19.6-nm line completely dominated the laser output. The output energy was measured to be 0.9 mJ in a beam of 6.6x30 mrad(2) divergence, corresponding to a conversion efficiency of 6 x 10(-6).
Resumo:
From measurements of spatial coherence and beam divergence of Ge soft x-ray laser at a far field, the x-ray laser beam has been characterized as a partially coherent Gaussian beam. Double-pass amplification will improve spatial and temporal coherence, spectral brightness and efficiency. Close to 100% geometrical coupling efficiency has been obtained in double pass amplification in Ge. Transient loss of feedback is attributed to mirror structure damage within the build-up time of the x-ray laser. Prospect for generation of coherent x-ray laser beam is discussed.
Resumo:
The use of two separate ultraintense laser pulses in laser-proton acceleration was compared to the single pulse case employing the same total laser energy. A double pulse profile, with the temporal separation of the pulses varied between 0.75-2.5 ps, was shown to result in an increased maximum proton energy and an increase in conversion efficiency to fast protons by up to a factor of 3.3. Particle-in-cell simulations indicate the existence of a two stage acceleration process. The second phase, induced by the main pulse preferentially accelerates slower protons located deeper in the plasma, in contrast to conventional target normal sheath acceleration.
Resumo:
We demonstrate experimentally that the relativistic electron flow in a dense plasma can be efficiently confined and guided in targets exhibiting a high-resistivity-core-low-resistivity-cladding structure analogous to optical waveguides. The relativistic electron beam is shown to be confined to an area of the order of the core diameter (50 mu m), which has the potential to substantially enhance the coupling efficiency of electrons to the compressed fusion fuel in the Fast Ignitor fusion in full-scale fusion experiments.
Resumo:
The properties of beams of high energy protons accelerated during ultraintense, picosecond laser-irradiation of thin foil targets are investigated as a function of preplasma expansion at the target front surface. Significant enhancement in the maximum proton energy and laser-to-proton energy conversion efficiency is observed at optimum preplasma density gradients due, to self-focusing Of the incident laser pulse. For very long preplasma expansion, the propagating laser pulse is observed to filament, resulting in highly uniform proton beams, but with reduced flux and maximum energy.
Resumo:
We present results of experiments studying the efficiency of high harmonic generation from a gas target using the TITANIA krypton fluoride laser at the Rutherford Appleton Laboratory. The variation of harmonic yield for the 7th to 13th harmonics (355-191 Angstrom) is studied as a function of the backing pressure of a solenoid valve gas jet and of the axial position of the laser focus relative to the centre of the gas jet nozzle. Harmonic energies up to 1 mu J were produced in helium and neon targets from laser energies of approximately 200 mJ. This corresponds to absolute conversion efficiencies of up to 5 x 10(-6).
Resumo:
We present images of the source of extreme ultraviolet (XUV) harmonic emission at a wavelength of 220 Angstrom from the interaction of a 20 TW, 1.053 mu m Nd:glass laser beam focused to intensities up to 4x10(18) W cm(-2) onto a solid target. From these measurements we determine an upper limit to the source size and brightness of the harmonic emission to show its efficacy as a novel source of short-pulse, coherent XUV radiation. We also demonstrate the empirical scaling of the harmonic generation efficiency with irradiance up to 10(19) W mu m(2) cm(-2), and extrapolate to estimate the possible source brightness at higher irradiances. These source brightnesses are compared to those available from an x-ray laser system. (C) 1997 American Institute of Physics.