995 resultados para image-guided radiotherapy
Resumo:
Techniques applying digital images increasingly have been used in biology, medicine, physics, and other research areas. The image coordinates can represent light intensities values to be detected by a CCD. Based on this concept, a photometric system composed of a LED source and a digital camera as a detector was used for optical density measurements. Standards for permanganate, glucose, and protein solutions were detemined by colorimetric methods using our device. Samples of protein of Pasteurella mutocida bacteria membrane and, also, fractions of rabbit kidney membrane, rich in Na, K-ATPase, with unknown concentrations were dosed through the Hartree method using our photometric system.
Resumo:
What different forms of engagement do image and text allow the spectator/reader? We know that text and image communicate, and that all communication depends on a relationship between those who communicate. The objective of this text is therefore to understand the new possibilities available to an anthropology of the expression of knowledge that makes use of images, such as photographs and films.
Resumo:
Purpose: To evaluate the risk of geographic miss associated with the classic four-field ""box"" irradiation technique and to define the variables that predict this risk. Materials and Methods: The study population consisted of 80 patients with uterine cervix cancer seen between 2001 and 2006. Median age was 55 years (23-82 years), and 72 (90%) presented with squamous cell carcinoma. Most patients (68.7%) presented with locally advanced disease (IIb or more). Magnetic resonance imaging findings from before treatment were compared with findings from simulation of the conventional four-field ""box"" technique done with rectal contrast. Study variables included tumor volume; involvement of vagina, parametrium, bladder, or rectum; posterior displacement of the anterior rectal wall; and tumor anteroposterior diameter (APD). Margins were considered adequate when the target volume (primary tumor extension, whole uterine body, and parametrium) was included within the field limits and were at least 1 cm in width. Results: Field limits were inadequate in 45 (56%) patients: 29 (36%) patients at the anterior and 28 (35%) at the posterior border of the lateral fields. Of these, 12 patients had both anterior and posterior miss, and this risk was observed in all stages of the disease (p = 0.076). Posterior displacement of the anterior rectal wall beyond S2-S3 was significantly correlated with the risk of geographic miss (p = 0.043). Larger tumors (APD 6 cm or above and volume above 50 cm(3)) were also significantly correlated with this risk (p = 0.004 and p = 0.046, respectively). Conclusions: Posterior displacement of the anterior rectal wall, tumor APD, and volume can be used as guidance in evaluating the risk of geographic miss. (C) 2009 Elsevier Inc.
Resumo:
Vagal Denervation and Neurally Mediated Syncope. A 15-year-old female patient presented with frequent episodes of vasovagal syncope refractory to non-pharmacological and pharmacological measures. Two tilt-table tests performed before and after conventional therapy were positive and reproduced the patient`s clinical symptoms. Selective vagal denervation, guided by HFS, was performed. Six radiofrequency pulses were applied on the left and right sides of the interatrial septum, abolishing vagal responses at these locations. Basal sinus node and Wenckebach cycle lengths changed significantly following ablation. A tilt test performed after denervation was negative and revealed autonomic tone modification. The patient reported significant improvement in quality of life and remained asymptomatic for 9 months after denervation. After this period, three episodes of NMS occurred during a 4-month interval and a tilt test performed 11 months after the procedure demonstrated vagal activity recovery. (J Cardiovasc Electrophysiol, Vol. 20, pp. 558-563, May 2009).
Resumo:
Objectives: Lung hyperinflation may be assessed by computed tomography (CT). As shown for patients with emphysema, however, CT image reconstruction affects quantification of hyperinflation. We studied the impact of reconstruction parameters on hyperinflation measurements in mechanically ventilated (MV) patients. Design: Observational analysis. Setting: A University hospital-affiliated research Unit. Patients: The patients were MV patients with injured (n = 5) or normal lungs (n = 6), and spontaneously breathing patients (n = 5). Interventions: None. Measurements and results: Eight image series involving 3, 5, 7, and 10 mm slices and standard and sharp filters were reconstructed from identical CT raw data. Hyperinflated (V-hyper), normally (V-normal), poorly (V-poor), and nonaerated (V-non) volumes were calculated by densitometry as percentage of total lung volume (V-total). V-hyper obtained with the sharp filter systematically exceeded that with the standard filter showing a median (interquartile range) increment of 138 (62-272) ml corresponding to approximately 4% of V-total. In contrast, sharp filtering minimally affected the other subvolumes (V-normal, V-poor, V-non, and V-total). Decreasing slice thickness also increased V-hyper significantly. When changing from 10 to 3 mm thickness, V-hyper increased by a median value of 107 (49-252) ml in parallel with a small and inconsistent increment in V-non of 12 (7-16) ml. Conclusions: Reconstruction parameters significantly affect quantitative CT assessment of V-hyper in MV patients. Our observations suggest that sharp filters are inappropriate for this purpose. Thin slices combined with standard filters and more appropriate thresholds (e.g., -950 HU in normal lungs) might improve the detection of V-hyper. Different studies on V-hyper can only be compared if identical reconstruction parameters were used.
Resumo:
Introduction. Two-dimensional (2-D) echocardiography is an excellent alternative method to perform endomyocardial biopsies (EB) in special situations, mainly when the patient is in a critical state and cannot go to the catheterization laboratory or when there are contraindications to the use of fluoroscopy as in the pregnancy. Objective. This single-center experience analyzed the last 25 years use of an EB technique guided by echocardiography realized at the bedside on critical patients. Methods. From 1985 to 2010, we performed 76 EB guided by 2-D echocardiography on 59 patients, among whom 38 (64.4%) were critically ill with examinations at the bedside; among 10 (16.9%) subjects, the procedure was carried out simultaneously with fluoroscopy for safety`s sake during the learning period. In addition, 8 (13.6%) were unavailable for fluoroscopy, and 3 (5.1%) required a hybrid method due to an intracardiac tumor. Results. The main adverse effects included local pain (n = 4, 5.6%); difficult out successful puncture due to previous biopsies (n = 4, 5.6%); local hematoma without major consequences (n = 3, 4.2%); failed but ultimately successful puncture on the first try due to previous biopsies or (n = 3, 4.2%); obesity and immediate postoperative period with impossibility to pass the bioptome into the right ventricle; however 2 days later the procedure was repeated successfully by echocardiography (n = 1, 1.4%). All myocardial specimens displayed suitable size. There were no undesirable extraction effects on the tricuspid valve tissue. In this series, there was no case of death, hemopericardium, or other major complication as a direct consequence of the biopsy. Conclusion. 2-D echocardiography is a special feature to guide EB is mainly in critically ill patients because it can be performed at the bedside without additional risk or disadvantages of fluoroscopy. The hybrid method associating 2-D echocardiography and fluoroscopy allows the procedure in different situations such as intracardiac tumor cases.
Resumo:
Arteriovenous fistula involving renal artery and inferior vena cava are rare. We report the case of a 47-year-old woman with a chronic arteriovenous fistula between right renal artery and inferior vena cava due to a penetrating trauma. Another finding was a vena cava aneurysm caused by the fistula. The patient was successfully treated with a covered stent in the renal artery. Diagnosis and postoperative control have been documented with CT scan. Endovascular techniques may be effective and minimally invasive option for treatment and renal preservation in renal-cava arteriovenous fistulae.
Resumo:
Objective: To investigate the possible role of chromatin texture parameters, nuclear morphology, DNA ploidy and clinical functional status in discriminating benign from malignant adrenocortical tumors (ACT). Patients and Methods: Forty-eight cases of clinically benign (n=40) and clinically malignant (n=8) ACT with a minimum of 5-years` follow-up were evaluated for chromatin texture parameters (run length, standard deviation, configurable run length, valley, slope, peak and other 21 Markovian features that describe the distribution of the chromatin in the nucleus), nuclear morphology (nuclear area, nuclear perimeter, nuclear maximum and minumum diameter, nuclear shape), and DNA ploidy. Nuclear parameters were evaluated in Feulgen-stained 5 mu m paraffin-sections analyzed using a CAS 200 image analyzer. Results: Since ACTs present different biological features in children and adults, patients were divided into two groups: children (<= 15 years) and adults (>15 years). In the group of children DNA ploidy presented a marginal significance (p=0.05) in discriminating ACTs. None of the parameters discriminated between malignant and benign ACT in the adult group. Conclusion: ACTs are uncommon and definitive predictive criteria for malignancy remain uncertain, particularly in children. Our data point to DNA content evaluated by image analysis as a new candidate tool for this challenging task. Texture image analysis did not help to differentiate malignant from benign adrenal cortical tumors in children and adults.
Resumo:
Background: Insulin resistance and obesity are recognized as left ventricular (LV) mass determinants independent of blood pressure (BP). Prevalence of LV hypertrophy (LVH) and the relationship between LV mass to body composition and metabolic variables were evaluated in normotensive individuals as participants of a population-based study. Methods: LV mass was measured using the second harmonic image by M-mode 2D guided echocardiography in 326 normotensive subjects (mean 47 +/- 9.4 years). Fasting serum lipids and glucose, BP, body composition and waist circumference (WC) were recorded during a clinic visit. Results: Applying a normalization criterion not related to body weight (g/height raised to the power 2.7) and the cut-off points of 47.7 (men) and 46.6 g/m(2.7) (women), LVH was found in 7.9% of the sample. Univariate analysis showed LV mass (g/m(2.7)) related to age, body mass index (BMI), WC, fat and lean body mass, systolic and diastolic BP, and metabolic variables (cholesterol, HDL-c, triglycerides and glucose). In multivariate analysis only BMI and age-adjusted systolic BP remained as independent predictors of LV mass, explaining 31% and 5% of its variability. Removing BMI from the model, WC, age-adjusted systolic BP and lean mass remained independent predictors, explaining 25.0%, 4.0% and 1.5% of LV mass variability, respectively. After sex stratification, LV mass predictors were WC (8%) and systolic BP (5%) in men and WC (36%) and systolic BP (3%) in women. Conclusion: BMI in general and particularly increased abdominal adiposity (WC as surrogate) seems to account for most of LV mass increase in normotensive individuals, mainly in women. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Radiation dose calculations in nuclear medicine depend on quantification of activity via planar and/or tomographic imaging methods. However, both methods have inherent limitations, and the accuracy of activity estimates varies with object size, background levels, and other variables. The goal of this study was to evaluate the limitations of quantitative imaging with planar and single photon emission computed tomography (SPECT) approaches, with a focus on activity quantification for use in calculating absorbed dose estimates for normal organs and tumors. To do this we studied a series of phantoms of varying complexity of geometry, with three radionuclides whose decay schemes varied from simple to complex. Four aqueous concentrations of (99m)Tc, (131)I, and (111)In (74, 185, 370, and 740 kBq mL(-1)) were placed in spheres of four different sizes in a water-filled phantom, with three different levels of activity in the surrounding water. Planar and SPECT images of the phantoms were obtained on a modern SPECT/computed tomography (CT) system. These radionuclides and concentration/background studies were repeated using a cardiac phantom and a modified torso phantom with liver and ""tumor"" regions containing the radionuclide concentrations and with the same varying background levels. Planar quantification was performed using the geometric mean approach, with attenuation correction (AC), and with and without scatter corrections (SC and NSC). SPECT images were reconstructed using attenuation maps (AM) for AC; scatter windows were used to perform SC during image reconstruction. For spherical sources with corrected data, good accuracy was observed (generally within +/- 10% of known values) for the largest sphere (11.5 mL) and for both planar and SPECT methods with (99m)Tc and (131)I, but were poorest and deviated from known values for smaller objects, most notably for (111)In. SPECT quantification was affected by the partial volume effect in smaller objects and generally showed larger errors than the planar results in these cases for all radionuclides. For the cardiac phantom, results were the most accurate of all of the experiments for all radionuclides. Background subtraction was an important factor influencing these results. The contribution of scattered photons was important in quantification with (131)I; if scatter was not accounted for, activity tended to be overestimated using planar quantification methods. For the torso phantom experiments, results show a clear underestimation of activity when compared to previous experiment with spherical sources for all radionuclides. Despite some variations that were observed as the level of background increased, the SPECT results were more consistent across different activity concentrations. Planar or SPECT quantification on state-of-the-art gamma cameras with appropriate quantitative processing can provide accuracies of better than 10% for large objects and modest target-to-background concentrations; however when smaller objects are used, in the presence of higher background, and for nuclides with more complex decay schemes, SPECT quantification methods generally produce better results. Health Phys. 99(5):688-701; 2010
Resumo:
Purpose: Erlotinib, an oral tyrosine kinase inhibitor, is active against head-and-neck squamous cell carcinoma (HNSCC) and possibly has a synergistic interaction with chemotherapy and radiotherapy. We investigated the safety and efficacy of erlotinib added to cisplatin and radiotherapy in locally advanced HNSCC. Methods and Materials: In this Phase I/II trial 100 mg/m(2) of cisplatin was administered on Days 8, 29, and 50, and radiotherapy at 70 Gy was started on Day 8. During Phase I, the erlotinib dose was escalated (50 mg, 100 mg, and 150 mg) in consecutive cohorts of 3 patients, starting on Day 1 and continuing during radiotherapy. Dose-limiting toxicity was defined as any Grade 4 event requiring radiotherapy interruptions. Phase 11 was initiated 8 weeks after the last Phase I enrollment. Results: The study accrued 9 patients in Phase I and 28 in Phase II; all were evaluable for efficacy and safety. No dose-limiting toxicity occurred in Phase I, and the recommended Phase 11 dose was 150 mg. The most frequent nonhematologic toxicities were nausea/vomiting, dysphagia, stomatitis, xerostomia and in-field dermatitis, acneiform rash, and diarrhea. Of the 31 patients receiving a 150-mg daily dose of erlotinib, 23 (74%; 95% confidence interval, 56.8%-86.3%) had a complete response, 3 were disease free after salvage surgery, 4 had inoperable residual disease, and 1 died of sepsis during treatment. With a median 37 months` follow-up, the 3-year progression-free and overall survival rates were 61% and 72%, respectively. Conclusions: This combination appears safe, has encouraging activity, and deserves further studies in locally advanced HNSCC. (C) 2010 Elsevier Inc.
Resumo:
Purpose: To compare the sparing potential of cerebral hemispheres with intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) for whole-ventricular irradiation (WVI) and conventional whole-brain irradiation (WBI) in the management of localized central nervous system germ cell tumors (CNSGCTs). Methods and Materials: Ten cases of patients with localized CNSGCTs and submitted to WVI by use of IMRT with or without a ""boost"" to the primary lesion were selected. For comparison purposes, similar treatment plans were produced by use of 3D-CRT (WVI with or without boost) and WBI (opposed lateral fields with or without boost), and cerebral hemisphere sparing was evaluated at dose levels ranging from 2 Gy to 40 Gy. Results: The median prescription dose for WVI was 30.6 Gy (range, 25.2-37.5 Gy), and that for the boost was 16.5 Gy (range, 0-23.4 Gy). Mean irradiated cerebral hemisphere volumes were lower for WVI with IMRT than for 3D-CRT and were lower for WVI with 3D-CRT than for WBI. Intensity-modulated radiotherapy was associated with the lowest irradiated volumes, with reductions of 7.5%, 12.2%, and 9.0% at dose levels., compared with 3D-CRT. Intensity-modulated radiotherapy provided of 20, 30, and 40 Gy, respectively statistically significant reductions of median irradiated volumes at all dose levels (p = 0.002 or less). However, estimated radiation doses to peripheral areas of the body were 1.9 times higher with IMRT than with 3D-CRT. Conclusions: Although IMRT is associated with increased radiation doses to peripheral areas of the body, its use can spare a significant amount of normal central nervous system tissue compared with 3D-CRT or WBI in the setting of CNSGCT treatment. (C) 2010 Elsevier Inc.
Resumo:
The present work is a report of the characterization of superparamagnetic iron oxide nanoparticles coated with silicone used as a contrast agent in magnetic resonance imaging of the gastrointestinal tract. The hydrodynamic size of the contrast agent is 281.2 rim, where it was determined by transmission electron microscopy and a Fe(3)O(4) crystalline structure was identified by X-ray diffraction, also confirmed by Mossbauer Spectroscopy. The blocking temperature of 190 K was determined from magnetic measurements based on the Zero Field Cooled and Field Cooled methods. The hysteresis loops were measured at different temperatures below and above the blocking temperature. Ferromagnetic resonance analysis indicated the superparamagnetic nature of the nanoparticles and a strong temperature dependence of the peak-to-peak linewidth Delta H(pp), giromagnetic factor g, number of spins N(S) and relaxation time T(2) were observed. This behavior can be attributed to an increase in the superexchange interaction.