967 resultados para high refractive index glass


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Refractive indices, n(D), and densities, rho, at 298.15 K were measured for the ternary mixture methanol (MeOH)/propan-1-ol (1-PrOH)/acetonitrile (MeCN) for a total of 22 mole fractions, along with 18 mole fractions of each of the corresponding binary mixtures, methanol/propan-1-ol, propan-1-ol/acetonitrile and methanol/acetonitrile. The variation of excess refractive indices and excess molar volumes with composition was modeled by the Redlich-Kister polynomial function in the case of binary mixtures and by the Cibulka equation for the ternary mixture. A thermodynamic approach to excess refractive indices, recently proposed by other authors, was applied for the first time to ternary liquid mixtures. Structural effects were identified and interpreted both in the binary and ternary systems. A complex relationship between excess refractive indices and excess molar volumes was identified, revealing all four possible sign combinations between these two properties. Structuring of the mixtures was also discussed on the basis of partial molar volumes of the binary and ternary mixtures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report an optical sensor based on localized surface plasmon resonance (LSPR) to study small-molecule protein interaction combining high sensitivity refractive index sensing for quantitative binding information and subsequent conformation-sensitive plasmon-activated circular dichroism spectroscopy. The interaction of α-amylase and a small-size molecule (PGG, pentagalloyl glucose) was log concentration-dependent from 0.5 to 154 μM. In situ tests were additionally successfully applied to the analysis of real wine samples. These studies demonstrate that LSPR sensors to monitor small molecule–protein interactions in real time and in situ, which is a great advance within technological platforms for drug discovery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study of chemical diffusion in biological tissues is a research field of high importance and with application in many clinical, research and industrial areas. The evaluation of diffusion and viscosity properties of chemicals in tissues is necessary to characterize treatments or inclusion of preservatives in tissues or organs for low temperature conservation. Recently, we have demonstrated experimentally that the diffusion properties and dynamic viscosity of sugars and alcohols can be evaluated from optical measurements. Our studies were performed in skeletal muscle, but our results have revealed that the same methodology can be used with other tissues and different chemicals. Considering the significant number of studies that can be made with this method, it becomes necessary to turn data processing and calculation easier. With this objective, we have developed a software application that integrates all processing and calculations, turning the researcher work easier and faster. Using the same experimental data that previously was used to estimate the diffusion and viscosity of glucose in skeletal muscle, we have repeated the calculations with the new application. Comparing between the results obtained with the new application and with previous independent routines we have demonstrated great similarity and consequently validated the application. This new tool is now available to be used in similar research to obtain the diffusion properties of other chemicals in different tissues or organs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de mestrado em Optometria Avançada

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Red blood cell (RBC) parameters such as morphology, volume, refractive index, and hemoglobin content are of great importance for diagnostic purposes. Existing approaches require complicated calibration procedures and robust cell perturbation. As a result, reference values for normal RBC differ depending on the method used. We present a way for measuring parameters of intact individual RBCs by using digital holographic microscopy (DHM), a new interferometric and label-free technique with nanometric axial sensitivity. The results are compared with values achieved by conventional techniques for RBC of the same donor and previously published figures. A DHM equipped with a laser diode (lambda = 663 nm) was used to record holograms in an off-axis geometry. Measurements of both RBC refractive indices and volumes were achieved via monitoring the quantitative phase map of RBC by means of a sequential perfusion of two isotonic solutions with different refractive indices obtained by the use of Nycodenz (decoupling procedure). Volume of RBCs labeled by membrane dye Dil was analyzed by confocal microscopy. The mean cell volume (MCV), red blood cell distribution width (RDW), and mean cell hemoglobin concentration (MCHC) were also measured with an impedance volume analyzer. DHM yielded RBC refractive index n = 1.418 +/- 0.012, volume 83 +/- 14 fl, MCH = 29.9 pg, and MCHC 362 +/- 40 g/l. Erythrocyte MCV, MCH, and MCHC achieved by an impedance volume analyzer were 82 fl, 28.6 pg, and 349 g/l, respectively. Confocal microscopy yielded 91 +/- 17 fl for RBC volume. In conclusion, DHM in combination with a decoupling procedure allows measuring noninvasively volume, refractive index, and hemoglobin content of single-living RBCs with a high accuracy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The application of two approaches for high-throughput, high-resolution X-ray phase contrast tomographic imaging being used at the tomographic microscopy and coherent radiology experiments (TOMCAT) beamline of the SLS is discussed and illustrated. Differential phase contrast (DPC) imaging, using a grating interferometer and a phase-stepping technique, is integrated into the beamline environment at TOMCAT in terms of the fast acquisition and reconstruction of data and the availability to scan samples within an aqueous environment. A second phase contrast method is a modified transfer of intensity approach that can yield the 3D distribution of the decrement of the refractive index of a weakly absorbing object from a single tomographic dataset. The two methods are complementary to one another: the DPC method is characterised by a higher sensitivity and by moderate resolution with larger samples; the modified transfer of intensity approach is particularly suited for small specimens when high resolution (around 1 mu m) is required. Both are being applied to investigations in the biological and materials science fields.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ground clutter caused by anomalous propagation (anaprop) can affect seriously radar rain rate estimates, particularly in fully automatic radar processing systems, and, if not filtered, can produce frequent false alarms. A statistical study of anomalous propagation detected from two operational C-band radars in the northern Italian region of Emilia Romagna is discussed, paying particular attention to its diurnal and seasonal variability. The analysis shows a high incidence of anaprop in summer, mainly in the morning and evening, due to the humid and hot summer climate of the Po Valley, particularly in the coastal zone. Thereafter, a comparison between different techniques and datasets to retrieve the vertical profile of the refractive index gradient in the boundary layer is also presented. In particular, their capability to detect anomalous propagation conditions is compared. Furthermore, beam path trajectories are simulated using a multilayer ray-tracing model and the influence of the propagation conditions on the beam trajectory and shape is examined. High resolution radiosounding data are identified as the best available dataset to reproduce accurately the local propagation conditions, while lower resolution standard TEMP data suffers from interpolation degradation and Numerical Weather Prediction model data (Lokal Model) are able to retrieve a tendency to superrefraction but not to detect ducting conditions. Observing the ray tracing of the centre, lower and upper limits of the radar antenna 3-dB half-power main beam lobe it is concluded that ducting layers produce a change in the measured volume and in the power distribution that can lead to an additional error in the reflectivity estimate and, subsequently, in the estimated rainfall rate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Contamination of weather radar echoes by anomalous propagation (anaprop) mechanisms remains a serious issue in quality control of radar precipitation estimates. Although significant progress has been made identifying clutter due to anaprop there is no unique method that solves the question of data reliability without removing genuine data. The work described here relates to the development of a software application that uses a numerical weather prediction (NWP) model to obtain the temperature, humidity and pressure fields to calculate the three dimensional structure of the atmospheric refractive index structure, from which a physically based prediction of the incidence of clutter can be made. This technique can be used in conjunction with existing methods for clutter removal by modifying parameters of detectors or filters according to the physical evidence for anomalous propagation conditions. The parabolic equation method (PEM) is a well established technique for solving the equations for beam propagation in a non-uniformly stratified atmosphere, but although intrinsically very efficient, is not sufficiently fast to be practicable for near real-time modelling of clutter over the entire area observed by a typical weather radar. We demonstrate a fast hybrid PEM technique that is capable of providing acceptable results in conjunction with a high-resolution terrain elevation model, using a standard desktop personal computer. We discuss the performance of the method and approaches for the improvement of the model profiles in the lowest levels of the troposphere.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nitrogen doped silicon (NIDOS) films have been deposited by low-pressure chemical vapor deposition from silane SiH4 and ammonia NH3 at high temperature (750°C) and the influences of the NH3/SiH4 gas ratio on the films deposition rate, refractive index, stoichiometry, microstructure, electrical conductivity, and thermomechanical stress are studied. The chemical species derived from silylene SiH2 into the gaseous phase are shown to be responsible for the deposition of NIDOS and/or (silicon rich) silicon nitride. The competition between these two deposition phenomena leads finally to very high deposition rates (100 nm/min) for low NH3/SiH4 gas ratio (R¿0.1). Moreover, complex variations of NIDOS film properties are evidenced and related to the dual behavior of the nitrogen atom into silicon, either n-type substitutional impurity or insulative intersticial impurity, according to the Si¿N atomic bound. Finally, the use of NIDOS deposition for the realization of microelectromechanical systems is investigated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rib-loaded waveguides containing Er3+-coupled Si nanoclusters (Si-nc) have been produced to observe optical gain at 1535 nm. The presence ofSi-nc strongly improves the efficiency ofEr 3+ excitation but may introduce optical loss mechanisms, such as Mie scattering and confined carrier absorption. Losses strongly affect the possibility of obtaining positive optical gain. Si-nc-related losses have been minimized to 1 dB/cm by lowering the annealing time ofthe Er3+-doped silicon-rich oxide deposited by reactive magnetron cosputtering. Photoluminescence (PL) and lifetime measurements show that all Er3+ ions are optically active while those that can be excited at high pump rates via Si-nc are only a small percentage. Er3+ absorption cross section is found comparable to that ofEr 3+ in SiO 2.However, dependence on the effective refractive index has been found. In pump-probe measurements, it is shown how the detrimental role ofconfined carrier absorption can be attenuated by reducing the annealing time. A maximum signal enhancement ofabout 1.34 at 1535 nm was measured.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tämän työn tarkoituksena oli tutkia pihkanhallintaa sulfaattisellutehtaalla ja uuteaineiden analysointimenetelmiä massasta ja suodoksesta. Tavoitteena oli kehittää uuteaineiden on-line mittausmenetelmä sulfaattisellutehtaalle. Kirjallisuusosassa esitettiin sulfaattisellun valmistusprosessi ja uuteaineiden käyttäytyminen prosessissa. Lisäksi työssä käsiteltiin tärkeimpiä pihkanhallintamenetelmiä ja uuteaineiden analysointia. Kokeellisessa osassa määritettiin uuteainepitoisuudet 29:stä massa- ja pesusuodosnäytteestä. Lisäksi suodosnäytteiden sameus ja kemiallinen hapenkulutus määritettiin laboratoriossa. On-line mittaukset tehtiin DD-pesurin paluusuodoksesta, josta mitattiin johtokyky, lämpötila, taitekerroin ja pH. Sameutta yritettiin mitata on-line nefelometrillä, mutta käytössä ollut laite ei soveltunut tumman suodoksen mittaamiseen. Työssä saatujen tulosten perusteella voidaan todeta, että pesusuodoksen ominaisuuksia mittaamalla ei voida arvioida massan uutepitoisuutta luotettavasti. Suodoksen ja massan uutepitoisuuksien välinen selitysaste oli 54%. Saippuoitumattomien uuteaineiden pitoisuuden ollessa erityisen suuri, suodoksen uutepitoisuus ei korreloi massassa olevan uutteen määrän kanssa. Täten kyseinen mittausmenetelmä ei ole sopiva, sillä se ei toimi silloin, kun olisi tärkeintä tietää oikea uuteainepitoisuus pihkanhallintakemikaalien annosten määrittämiseksi. Suodoksen sameus riippui sen uutepitoisuudesta 80% selitysasteella. Sameusmittaus on nopea ja suhteellisen luotettava menetelmä suodosten uutepitoisuuksien arviointiin, mutta se vaatii mittalaitteen joka käyttää usean ilmaisimen tekniikkaa. On-line-mittauksissa laitteisto tulisi varustaa automaattisella pesulaitteella, sillä mittarin linssit likaantuvat helposti prosessivirrassa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work we describe the synthesis and characterization of chalcogenide glass (0.3La2S3-0.7Ga2S 3) with low phonons frequencies. Several properties were measured like Sellmeier parameters, linear refractive index dispersion and material dispersion. Samples with the composition above were doped with Dy2S3. The absorption and emission characteristics were measured by electronic spectroscopy and fluorescence spectrum respectively. Raman and infrared spectroscopy shows that these glasses present low phonons frequencies and strucuture composed by GaS4 tetrahedrals. The Lines model was used for calculate the coefficients values of the non linear refractive index.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the nutritional value of sesame and flaxseed oils and their effects on the lipid and glucose profile of rats fed diets containing different fat combinations. Fatty acid composition, refractive index, and iodine and saponification values were analyzed to characterize the oils. In the biological assay, Wistar rats were fed different diets, whose fat composition consisted of varying combinations of flaxseed oil, sesame oil, and animal fat. The primary constituents of the sesame oil were oleic (28.6%), linoleic (28.4%), and lauric acid (14.6%); for the flaxseed oil they were alpha-linolenic (39.90%), oleic (17.97%) and linoleic acid (12.25%). The iodine and saponification values of the oils were within the reference range. Rats fed flaxseed oil-based diets had the lowest serum cholesterol values, whereas rats fed diets with flaxseed oil + sesame oil + animal fat had the highest glucose levels. HDL levels decreased significantly with flaxseed oil. Sesame and flaxseed oils are sources of polyunsaturated fatty acids (PUFA), and the flaxseed oil-based diet had a hypocholesterolemic effect, whereas sesame oil showed oxidative stability since it contains high levels of monounsaturated and saturated fatty acids.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The physical and chemical alterations in palm oil during continuous industrial par frying of breaded chicken snacks were evaluated using a pseudo first-order kinetic model. The acidity index, refractive index, concentration of polar compounds, viscosity, color, and absorbance (232 and 268 nm) of 238 samples of the frying oil collected during 26 days of production were analyzed. For all of the analyses, the results of the oil were below the limits recommended for oil disposal, indicating that the processing conditions were safe and that under these experimental conditions the oil remained suitable for frying. The linear regressions were significant for refractive index, content of polar compounds, and lightness (L*). The content of polar compounds was determined using a cooking oil tester, and it had the best fit to the proposed model and can be used as an effective index for monitoring palm oil during the continuous par frying of breaded chicken snacks. The high turnover rate of the oil was important for maintaining the oil in good running conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The sugars in apple juice prove its authenticity and its sensory and nutritional properties. The aim of this study was to develop and validate a simple analytical method using high performance liquid chromatography with refractive index detection (HPLC-RI) to determinate and quantify the sugars sucrose, D-glucose, D-fructose, and D-sorbitol polyol in apple juices, as well as to analyze the juices from the Fuji suprema and Lis Gala cultivars at three ripening stages. The analytical performance parameters evaluated indicated that the method was specific for the compounds analyzed, and the linearity of the calibration curves of sugars showed high correlation coefficients (close to 1.0). The limits of detection and quantification are consistent with recommendations available in the literature for this type of matrix. Sample preparation is simple and generates small amount of residues. Over 70% of the sugars were determined in the juices of apples at the pre-ripe stage, with an increase during senescence. This method is applicable for the determination of sugars in juices and evaluation of apple ripening.