872 resultados para etching


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reports on an innovative approach to measuring intraluminal pressure in the upper gastrointestinal (GI) tract, especially monitoring GI motility and peristaltic movements. The proposed approach relies on thin-film aluminum strain gauges deposited on top of a Kapton membrane, which in turn lies on top of an SU-8 diaphragm-like structure. This structure enables the Kapton membrane to bend when pressure is applied, thereby affecting the strain gauges and effectively changing their electrical resistance. The sensor, with an area of 3.4 mm2, is fabricated using photolithography and standard microfabrication techniques (wet etching). It features a linear response (R2 = 0.9987) and an overall sensitivity of 2.6 mV mmHg−1. Additionally, its topology allows a high integration capability. The strain gauges’ responses to pressure were studied and the fabrication process optimized to achieve high sensitivity, linearity, and reproducibility. The sequential acquisition of the different signals is carried out by a microcontroller, with a 10-bit ADC and a sample rate of 250 Hz. The pressure signals are then presented in a user-friendly interface, developed using the Integrated Development Environment software, QtCreator IDE, for better visualization by physicians.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Estudi elaborat a partir d’una estada al Paul Scherrer Institut del Maig a l’Octubre del 2006 amb l’ajuda i supervisió dels Dr. Konstantins Jefimovs i Dr. Christian David. Focalitzar raigs X tous és una necessitat essencial per al microanàlisis, la microscopia, i fer imatges en moltes Instal·lacions de Radiació Sincrotró. Les Lents Zonals de Fresnel (FZP, de la denominació anglesa “Fresnel Zone Plates”) han demostrat donar uns punts focals amb una resolució espacial destacada i una baixa il·luminació de fons. Tanmateix, la fabricació de FZP és complexa i no totalment reproduïble. A més a més, el temps de vida de les FZP és força curt, ja que estant situades sobre membranes de nitrur de silici molt fines i altament absorbents. Per tant, hem fet esforços per implementar FZP de silici, que s’espera que siguin més resistents. L’element està fet d’una oblia de cristall de silici poc absorbent, i no presenta cap interfase entre materials. Així doncs, aquestes lents són especialment adequades per a aguantar les extremes càrregues de radiació de les fonts de raigs X més brillants. Particularment, això és molt important per a les aplicacions a les pròximes generacions de fonts de raigs X, com els Làsers d’Electrons Lliures (FEL, de la denominació anglesa “Free Electron Laser”). El silici també garanteix que no hi hagi cap banda d’absorció en el rang d’energies de la finestra de l’aigua (200-520 eV), fent aquestes lents ideals per a fer imatges de mostres biològiques. En aquest informe, hi ha una descripció detallada de tots els passos involucrats en la fabricació de les Lents Zonals de Fresnel de silici. En resum, les estructures de FZP es modelen sobre una resina utilitzant litografia per feix d’electrons i llavors el patró es transmet al silici mitjançant un gravat d’ions reactius (RIE, de la denominació anglesa ‘Reactive Ion Etching’) utilitzant una fina (20 nm) màscara de Crintermitja. Les membranes de silici es poden aprimar després de la fabricació de les estructures per a garantir una transmissió suficient fins i tot a baixes energies. Aquest informe també inclou l’anàlisi i la discussió d’alguns experiments preliminars per avaluar el rendiment de les Si FZPs fets a la línia de llum PolLux del Swiss Ligth Source amb l’ajuda dels Dr. Jörg Raabe i Dr. George Tzvetkov.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Es presenten els resultats experimentals obtinguts durant l’estudi sistemàtic realitzat de la preparació electroquímica de puntes de tungstè per al Microscopi d’Efecte Túnel (STM), fent servir dos electròlits: KOH i NaOH. L’estudi sobre la morfologia, longitud de la punta i radi de curvatura de la punta en funció del voltatge aplicat i les concentracions de l’electròlit es descriu al capítol 3. La caracterització de les puntes es va dur a terme, per una part, mitjançant un microscòpic electrònic de rastreig (SEM) i per l’altre banda, amb el ús de les puntes obtingudes al STM. En resumen, els resultats mostren que ambdós electròlits permeten obtenir puntes que es poden fer servir amb èxit per l’obtenció d’imatges amb l’STM. Les millors puntes són aquelles que s’obtenen dins de rangs de concentracions d’electròlit baixes, entre valor de 10 a 15% en pes pel NaOH i entre 10 i 20% pel KOH i rangs de voltatge entre 3 a 7 V pel NaOH i 4 a 8 V pel KOH. S’observa que es requereixen temps d’atac electroquímic menors fent servir com a electròlit NaOH. S’estudia, en el capítol 4, el tractament que requereix la punta per tal d’eliminar les impureses de la seva superfície. Es realitzen diferents proves amb tres mètodes de neteja: (1) tractament químic, (2) bombardeig iònic i (3) tractament tèrmic de recuit. En el capítol 5 del projecte s’analitzen les imatges d’una mostra d’or, Au(110), d’estructura coneguda, amb el microscopi d’efecte túnel STM) del laboratori fent servir les puntes obtingudes sota les condicions considerades òptimes. El resultat confirma el bon comportament de les puntes obtingudes sota les condicions descrites en els capítols anteriors i establert una pauta a seguir per obtenir puntes d’una manera senzilla i reproduïble.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To carry out a meta-analysis in order to assess the influencing factors on retention loss and marginal discoloration of cervical restorations made of composites and glass ionomer (derivates). METHODS: The literature was searched for prospective clinical studies on cervical restorations with an observation period of at least 18 months. RESULTS: Fifty clinical studies involving 40 adhesive systems matched the inclusion criteria. On average, 10% of the cervical fillings were lost and 24% exhibited marginal discoloration after 3 years. The variability ranged from 0% to 50% for retention loss and from 0% to 74% for marginal discoloration. Hardly any secondary caries was detected. When linear mixed models with a study and experiment effect were used, the analysis revealed that the adhesive/restorative class had the most significant influence, with 2-step self-etching adhesive systems performing best and 1-step self-etching adhesive systems performing worst; 3-step etch-and-rinse systems, glass ionomers/resin-modified glass ionomers, 2-step etch-and-rinse systems and polyacid-modified resin composites were ranked in between. Restorations placed in teeth whose dentin/enamel had been prepared/roughened showed a statistically significant higher retention rate than those placed in teeth with unprepared dentin (p<0.05). Beveling of the enamel and the type of isolation used (rubberdam/cotton rolls) had no significant influence. SIGNIFICANCE: The clinical performance of cervical restorations is significantly influenced by the type of adhesive system used and/or the adhesive class to which the system belonged and whether the dentin/enamel is prepared or not. 2-Step self-etching- and 3-step etch&rinse systems shall be chosen over 1-step self-etching systems and glass ionomer derivates. The dentin (and enamel) surface shall be roughened before placement of the restoration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study we evaluate the dynamics of the biophile element phosphorus (P) in the catchment and proglacial areas of the Rhone and Oberaar glaciers (central Switzerland). We analysed erosion and dissolution rates of P-containing minerals in the subglacial environment by sampling water and suspended sediment in glacier outlets during three ablation and two accumulation seasons. We also quantified biogeochemical weathering rates of detrital P in proglacial sedimentary deposits using two chronosequences of samples of fresh, suspended, material obtained from the Oberaar and Rhone water outlets, Little-Ice-Age (LIA) moraines and Younger Dryas (YD) tills in each catchment. Subglacial P weathering is mainly a physical process and detrital P represents more than 99%, of the precipitation-corrected total P denudation flux (234 and 540 kg km(-2) yr(-1) for the Rhone and Oberaar catchments, respectively). The calculated detrital P flux rates are three to almost five times higher than the world average flux. The precipitation-corrected soluble reactive P (SRP) flux corresponds to 1.88-1.99 kg km(-2) yr(-1) (Rhone) and 2.12-2.44 kg km(-2) yr(-1) (Oberaar), respectively. These fluxes are comparable to those of tropical rivers draining transport-limited, tectonically inactive weathering areas. In order to evaluate the efficiency of detrital P weathering in the Rhone and Oberaar proglacial areas, we systematically graded apatite grains extracted from the chronosequence in each catchment relative to weathering-induced changes in their surface morphologies (grades 1-4). Fresh apatite grains are heavily indented and dissolution rounded (grade 1). LIA grains from two 0-10 cm deep moraine samples show extensive dissolution etching, similar to surface grains from the YD profile (mean grades 2.7, 3.5 and 3.5, respectively). In these proglacial deposits, the weathering front deepens progressively as a function of time due to biocorrosion in the evolving acidic pedosphere, with mechanical indentations on grains acting as sites of preferential dissolution. We also measured iron-bound, organic and detrital P concentrations in the chronosequence and show that organic and iron-bound P has almost completely replaced detrital P in the top layers of the YD profiles. Detrital P weathering rates are calculated as 3 10 and 280 kg km(-2) yr(-1) for LIA moraines and 10 kg km(-2) yr(-1) for YD tills. During the first 300 years of glacial sediment exposure P dissolution rates are shown to be approximately 70 times higher than the mean global dissolved P flux from ice-free continents. After 11.6 kyr the flux is 2.5 times the global mean. These data strengthen the argument for substantial changes in the global dissolved P flux on glacial-interglacial timescales. A crude extrapolation from the data described here suggests that the global dissolved P flux may increase by 40-45% during the first few hundred years of a deglaciation phase

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report on the study and modeling of the structural and optical properties of rib-loaded waveguides working in the 600-900-nm spectral range. A Si nanocrystal (Si-nc) rich SiO2 layer with nominal Si excess ranging from 10% to 20% was produced by quadrupole ion implantation of Si into thermal SiO2 formed on a silicon substrate. Si-ncs were precipitated by annealing at 1100°C, forming a 0.4-um-thick core layer in the waveguide. The Si content, the Si-nc density and size, the Si-nc emission, and the active layer effective refractive index were determined by dedicated experiments using x-ray photoelectron spectroscopy, Raman spectroscopy, energy-filtered transmission electron microscopy, photoluminescence and m-lines spectroscopy. Rib-loaded waveguides were fabricated by photolithographic and reactive ion etching processes, with patterned rib widths ranging from 1¿to¿8¿¿m. Light propagation in the waveguide was observed and losses of 11dB/cm at 633 and 780 nm were measured, modeled and interpreted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The influence of premetallization surface preparation on the structural, chemical, and electrical properties of Au-nGaN interfaces has been investigated by x-ray photoemission spectroscopy (XPS), current-voltage measurement (I-V) and cross-section transmission electron microscopy (TEM). XPS analysis showed that the three GaN substrate treatments investigated i.e., ex situ hydrofluoric acid etch, in situ anneal in ultrahigh-vacuum (UHV), and in situ Ga reflux cleaning in UHV result in surfaces increasingly free of oxygen contamination. XPS and TEM characterization of Au-nGaN formed after the three premetallization surface treatments show that HF etching and UHV annealing produce abrupt, well-defined interfaces. Conversely, GaN substrate cleaning in a Ga flux results in Au/GaN intermixing. I-V characterization of Au¿nGaN contacts yields a Schottky barrier height of 1.25 eV with a very low-ideality factor and very good contact uniformity for the premetallization UHV anneal, while the Ga reflux cleaning results in a much lower barrier (0.85 eV), with poor ideality and uniformity. I-V and XPS results suggest a high density of acceptor states at the surface, which is further enhanced by UHV annealing. These results are discussed in the context of current models of Schottky barrier formation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a high‐resolution electron microscopy study of the microstructure of boron nitride thin films grown on silicon (100) by radio‐frequency plasma‐assisted chemical vapor deposition using B2H6 (1% in H2) and NH3 gases. Well‐adhered boron nitride films grown on the grounded electrode show a highly oriented hexagonal structure with the c‐axis parallel to the substrate surface throughout the film, without any interfacial amorphous layer. We ascribed this textured growth to an etching effect of atomic hydrogen present in the gas discharge. In contrast, films grown on the powered electrode, with compressive stress induced by ion bombardment, show a multilayered structure as observed by other authors, composed of an amorphous layer, a hexagonal layer with the c‐axis parallel to the substrate surface and another layer oriented at random

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present an ellipsometric technique and ellipsometric analysis of repetitive phenomena, based on the experimental arrangement of conventional phase modulated ellipsometers (PME) c onceived to study fast surface phenomena in repetitive processes such as periodic and triggered experiments. Phase modulated ellipsometry is a highly sensitive surface characterization technique that is widely used in the real-time study of several processes such as thin film deposition and etching. However, fast transient phenomena cannot be analyzed with this technique because precision requirements limit the data acquisition rate to about 25 Hz. The presented new ellipsometric method allows the study of fast transient phenomena in repetitive processes with a time resolution that is mainly limited by the data acquisition system. As an example, we apply this new method to the study of surface changes during plasma enhanced chemical vapor deposition of amorphous silicon in a modulated radio frequency discharge of SiH4. This study has revealed the evolution of the optical parameters of the film on the millisecond scale during the plasma on and off periods. The presented ellipsometric method extends the capabilities of PME arrangements and permits the analysis of fast surface phenomena that conventional PME cannot achieve.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To determine if the results of resin-dentin microtensile bond strength (µTBS) is correlated with the outcome parameters of clinical studies on non-retentive Class V restorations. METHODS: Resin-dentin µTBS data were obtained from one test center; the in vitro tests were all performed by the same operator. The µTBS testing was performed 8h after bonding and after 6 months of storing the specimens in water. Pre-test failures (PTFs) of specimens were included in the analysis, attributing them a value of 1MPa. Prospective clinical studies on cervical restorations (Class V) with an observation period of at least 18 months were searched in the literature. The clinical outcome variables were retention loss, marginal discoloration and marginal integrity. Furthermore, an index was formulated to be better able to compare the laboratory and clinical results. Estimates of adhesive effects in a linear mixed model were used to summarize the clinical performance of each adhesive between 12 and 36 months. Spearman correlations between these clinical performances and the µTBS values were calculated subsequently. RESULTS: Thirty-six clinical studies with 15 adhesive/restorative systems for which µTBS data were also available were included in the statistical analysis. In general 3-step and 2-step etch-and-rinse systems showed higher bond strength values than the 2-step/3-step self-etching systems, which, however, produced higher values than the 1-step self-etching and the resin modified glass ionomer systems. Prolonged water storage of specimens resulted in a significant decrease of the mean bond strength values in 5 adhesive systems (Wilcoxon, p<0.05). There was a significant correlation between µTBS values both after 8h and 6 months of storage and marginal discoloration (r=0.54 and r=0.67, respectively). However, the same correlation was not found between µTBS values and the retention rate, clinical index or marginal integrity. SIGNIFICANCE: As µTBS data of adhesive systems, especially after water storage for 6 months, showed a good correlation with marginal discoloration in short-term clinical Class V restorations, longitudinal clinical trials should explore whether early marginal staining is predictive for future retention loss in non-carious cervical restorations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of the study was to evaluate the shear bond strength of stainless steel orthodontic brackets directly bonded to extracted human premolar teeth. Fifty teeth were randomly divided into ¿ve groups: (1) System One (chemically cured composite resin), (2) Light Bond (light-cured composite resin), (3) Vivaglass Cem (self-curing glass ionomer cement), (4) Fuji Ortho LC (light-cured glass ionomer cement) used after 37% orthophosphoric acid¿etching of enamel (5) Fuji Ortho LC without orthophosphoric acid¿etching. The brackets were placed on the buccal and lingual surfaces of each tooth, and the specimens were stored in distilled water (24 hours) at 378C and thermocycled. Teeth were mounted on acrylic block frames, and brackets were debonded using an Instron machine. Shear bond strength values at fracture (Nw)were recorded. ANOVA and Student-Newman-Keuls multiple comparison tests were performed (P , .05). Bonding failure site was recorded by stereomicroscope and analyzed by Chi-square test, selected specimens of each group were observed by scanning electron microscope. System One attained the highest bond strength. Light Bond and Fuji Ortho LC, when using an acid-etching technique, obtained bond strengths that were within the range of estimated bond strength values for successful clinical bonding. Fuji Ortho LC and Vivaglass Cem left an almost clean enamel surface after debracketing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The formation of silicon particles in rf glow discharges has attracted attention due to their effect as a contaminant during film deposition or etching. However, silicon and silicon alloy powders produced by plasma¿enhanced chemical vapor deposition (PECVD) are promising new materials for sintering ceramics, for making nanoscale filters, or for supporting catalytic surfaces. Common characteristics of these powders are their high purity and the easy control of their stoichiometry through the composition of the precursor gas mixture. Plasma parameters also influence their structure. Nanometric powders of silicon¿carbon alloys exhibiting microstructural properties such as large hydrogen content and high surface/volume ratio have been produced in a PECVD reactor using mixtures of silane and methane at low pressure (-1 Torr) and low frequency square¿wave modulated rf power (13.56 MHz). The a¿Si1¿xCx:H powders were obtained from different precursor gas mixtures, from R=0.05 to R=9, where R=[SiH4]/([SiH4]+[CH4]). The structure of the a¿Si1¿xCx:H powder was analyzed by several techniques. The particles appeared agglomerated, with a wide size distribution between 5 and 100 nm. The silane/methane gas mixture determined the vibrational features of these powders in the infrared. Silicon-hydrogen groups were present for every gas composition, whereas carbon¿hydrogen and silicon¿carbon bonds appeared in methane¿rich mixtures (R-0.6). The thermal desorption of hydrogen revealed two main evolutions at about 375 and 660¿°C that were ascribed to hydrogen bonded to silicon and carbon, respectively. The estimated hydrogen atom concentration in the sample was about 50%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: More than five hundred million direct dental restorations are placed each year worldwide. In about 55% of the cases, resin composites or compomers are used, and in 45% amalgam. The longevity of posterior resin restorations is well documented. However, data on resin composites that are placed without enamel/dentin conditioning and resin composites placed with self-etching adhesive systems are missing. Material and Methods: The database SCOPUS was searched for clinical trials on posterior resin composites without restricting the search to the year of publication. The inclusion criteria were: (1) prospective clinical trial with at least 2 years of observation; (2) minimum number of restorations at last recall = 20; (3) report on dropout rate; (4) report of operative technique and materials used; (5) utilization of Ryge or modified Ryge evaluation criteria. For amalgam, only those studies were included that directly compared composite resin restorations with amalgam. For the statistical analysis, a linear mixed model was used with random effects to account for the heterogeneity between the studies. P-values under 0.05 were considered significant. Results: Of the 373 clinical trials, 59 studies met the inclusion criteria. In 70% of the studies, Class II and Class I restorations had been placed. The overall success rate of composite resin restorations was about 90% after 10 years, which was not different from that of amalgam. Restorations with compomers had a significantly lower longevity. The main reason for replacement were bulk fractures and caries adjacent to restorations. Both of these incidents were infrequent in most studies and accounted only for about 6% of all replaced restorations after 10 years. Restorations with macrofilled composites and compomer suffered significantly more loss of anatomical form than restorations with other types of material. Restorations that were placed without enamel acid etching and a dentin bonding agent showed significantly more marginal staining and detectable margins compared to those restorations placed using the enamel-etch or etch-and-rinse technique; restorations with self-etching systems were between the other groups. Restorations with compomer suffered significantly more chippings (repairable fracture) than restorations with other materials, which did not statistically differ among each other. Restorations that were placed with a rubber-dam showed significantly fewer material fractures that needed replacement, and this also had a significant effect on the overall longevity. Conclusion: Restorations with hybrid and microfilled composites that were placed with the enamel-etching technique and rubber-dam showed the best overall performance; the longevity of these restorations was similar to amalgam restorations. Compomer restorations, restorations placed with macrofilled composites, and resin restorations with no-etching or self-etching adhesives demonstrated significant shortcomings and shorter longevity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

According to Ray Harryhausen, a special effects expert in the film industry, "Gustave Doré would have made a great director of photography . . . He saw things from the point of view of the camera." Doré's work has had a permanent impact on the imaginative realm of film since its very early days. In return, the silver screen has etched Doré into the 20th century imagination. Almost every film about the Bible since The Life and Passion of Jesus Christ produced by Pathé in 1902 refers to his illustrations, and every film adaptation of Dante or Don Quixote has used him as a model, from Georg Wilhelm Pabst and Orson Welles to Terry Gilliam. All films dealing with life in London in the Victorian era by directors ranging from David Lean, to Roman Polanski and Tim Burton draw on the visions in London: a pilgrimage for their sets. A large number of dream fantastical or phantasmagorical scenes take their inspiration from Doré's graphic world, beginning with Georges Méliès' A Trip to the Moon in 1902. In the realm of cartoons and animation, Walt Disney owes a huge debt to Doré. Doré primal forests, from Atala in particular, were also used in the various versions of King Kong from 1933 to the 2005 film by Peter Jackson, who had already drawn on Doré for The Lord of the Rings. Jean Cocteau was also indebted to the illustrations for Perrault's Fairy Tales for his Beauty and the Beast (1945), as was George Lucas for the character Chewbacca in Star Wars (1977) and even the Harry Potter film series. Through his influence on film history, Doré shaped the mass culture imagination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To evaluate the shear bond strength and site of failure of brackets bonded to dry and wet enamel. Study design: 50 teeth were divided into ten groups of 5 teeth each (10 surfaces). In half the groups enamel was kept dry before bonding, and in the other half distilled water was applied to wet the surface after etching. The following groups were established: 1)Acid/Transbond-XT (dry/wet) XT; 2) Transbond Plus Self Etching Primer (TSEP)/Transbond-XT paste (dry/wet); 3) Concise (dry), Transbond MIP/Concise (wet), 4) FujiOrtho-LC (dry/wet); 5) SmartBond (dry/wet). Brackets were bonded to both buccal and lingual surfaces. Specimens were stored in distilled water (24 hours at 37ºC) and thermocycled. Brackets were debonded using a Universal testing machine (cross-head speed 1 mm/min). Failure sites were classified using a stereomicroscope. Results: No significant differences in bond strength were detected between the adhesives under wet and dry conditions except for Smart- Bond, whose bond strength was significantly lower under dry conditions. For all the adhesives most bond failures were of mixed site location except for Smartbond, which failed at the adhesive-bracket interface. Conclusions: Under wet conditions the bonding capacity of the adhesives tested was similar than under dry conditions, with the exception of SmartBond which improved under wet conditions