944 resultados para end-to-end testing, javascript, application web, single-page application


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Deterioration phenomena occurring on outdoor cultural heritage have been the subject of several studies, but relatively few works investigated the specific role of Particulate Matter (PM) in the corrosion of metals. This topic is really complex and, besides field exposures, accelerated ageing tests are also necessary to isolate and understand deterioration mechanisms due to PM. For this reason, the development of a methodology that allows to reproduce and analyze the effect of PM on alloys through accelerated ageing in climatic chamber has been started. On quaternary bronze specimens, single salts and a mix of them were deposited via two deposition methods: dry (directly depositing the salt on the surface) and wet (dropping a salt solution and drying it), simulating the initial chemical activation of the salts by RH% variations or by raindrops, respectively. Then, to better mimic the composition of real PM, a mixture containing a soluble salts, a mineral, a black carbon and an organic fraction was formulated and spread on the samples. The samples were placed in a climatic chamber and exposed to cyclic variations of T and RH for three weeks. The ageing cycles were set according to predictions on salt deliquescence/recrystallization through E-AIM model and to the evaluation of regional climatic data. The surface evolution was followed by SEM-EDX, Raman, AT-IR and UV-Vis Spectrophotometry. At the end of the test, mass losses were determined and corroded metals removed by pickling were analyzed by AAS. On the basis of the obtained results, the tested procedures seem to be promising in accelerating and mimicking realistic corrosion phenomena, as under the selected conditions, corrosion products typically found at different exposure time (from days to years) on outdoor bronzes were able to progressively form and evolve. Moreover, the two deposition modes simulating different condition of chemical activation of PM deposits allow to obtain complementary information.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nowadays the leukodepletion is one of the most important processes done on the blood in order to reduce the risk of transfusion diseases. It can be performed through different techniques but the most popular one is the filtration due to its simplicity and efficiency. This work aims at improving a current commercial product, by developing a new filter based on Fenton-type reaction to cross-link a hydrogel on to the base material. The filters for leukodepletion are preferably made through the melt flow technique resulting in a non-woven tissue; the functionalization should increase the stability of the filter restricting the extraction of substances to minimum amount when in contact with blood. Through the modification the filters can acquire new properties including wettability, surface charge and good resistance to the extractions. The most important for leukodepletion is the surface charge due to the nature of the filtration process. All the modified samples results have been compared to the commercial product. Three different polymers (A, B and C) have been studied for the filter modifications and every modified filter has been tested in order to determine its properties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Il trapianto polmonare rappresenta l'unica soluzione percorribile per l'insufficienza respiratoria end-stage. La principale limitante ad un suo impiego è rappresentata dalla scarsità di polmoni idonei. In questo contesto si colloca il progetto di ricondizionamento ex-vivo. L'implementazione risulta possibile attraverso il ricondizionamento di organi cosiddetti “marginali” o giudicati inizialmente non idonei al trapianto e da donatori a cuore fermo (Donor after Cardiac Death – DCD). Scopo Lo scopo principale del progetto è quello di analizzare i risultati a breve e medio termine del trapianto polmonare effettuato impiegando polmoni sottoposti a procedura di ricondizionamento ex-vivo in due centri trapianti di polmone a basso volume. Materiali e Metodi I dati sono stati raccolti retrospettivamente (da Giugno 2013 per quanto riguarda l’ISMETT e dal 2014 quelli dell’ Ospedale S. Orsola-Malpighi) e in maniera prospettica dal 2019. Risultati Sommando i dati relativi ad entrambi i centri, dal 2013 sono stati eseguiti un totale di 26 procedure di riperfusione. Sei volte i polmoni sono stati giudicati idonei al trapianto al termine con 5 trapianti doppi e un trapianto singolo sinistro. I risultati in termine di sopravvivenza a medio termine sono risultati sovrapponibili a quelli disponibili in letteratura, tuttavia è stato registrato un alto tasso di PGD (Primary Graft Disfunction) di grado 3, da imputare alla patologia di base del ricevente (ipertensione polmonare), che per protocollo di istituto rimane con supporto cardio-respiratorio (ECMO) dopo il trapianto. Conclusioni L’EVLP si conferma in centri di piccolo e medio volume un metodo sicuro ed efficace per implementare in numero di polmoni idonei al trapianto.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Continuum parallel robots (CPRs) are manipulators employing multiple flexible beams arranged in parallel and connected to a rigid end-effector. CPRs promise higher payload and accuracy than serial CRs while keeping great flexibility. As the risk of injury during accidental contacts between a human and a CPR should be reduced, CPRs may be used in large-scale collaborative tasks or assisted robotic surgery. There exist various CPR designs, but the prototype conception is rarely based on performance considerations, and the CPRs realization in mainly based on intuitions or rigid-link parallel manipulators architectures. This thesis focuses on the performance analysis of CPRs, and the tools needed for such evaluation, such as workspace computation algorithms. In particular, workspace computation strategies for CPRs are essential for the performance assessment, since the CPRs workspace may be used as a performance index or it can serve for optimal-design tools. Two new workspace computation algorithms are proposed in this manuscript, the former focusing on the workspace volume computation and the certification of its numerical results, while the latter aims at computing the workspace boundary only. Due to the elastic nature of CPRs, a key performance indicator for these robots is the stability of their equilibrium configurations. This thesis proposes the experimental validation of the equilibrium stability assessment on a real prototype, demonstrating limitations of some commonly used assumptions. Additionally, a performance index measuring the distance to instability is originally proposed in this manuscript. Differently from the majority of the existing approaches, the clear advantage of the proposed index is a sound physical meaning; accordingly, the index can be used for a more straightforward performance quantification, and to derive robot specifications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: It is recognized that the growing epidemic of metabolic syndrome is related to dietary and lifestyle changes. Objective: The purpose of this study was to evaluate short-term application of nutritional counseling in women with metabolic syndrome. Methods: This follow-up study was conducted from September to November 2008 with thirty three women >= 35 years old screened clinically for nutritional counseling. Dietary intake was reported, and biochemical and body composition measures were taken at baseline and after three months of follow-up. Results: Of the 33 women evaluated, 29 patients completed the study. The prevalence of type 2 diabetes mellitus, hypertension, dyslipidemia, and obesity was high at 38%, 72.4%, 55.2%, and 75.8%, respectively. At the end of three-months of follow-up, a significant decline in body mass index, waist circumference, triceps skinfold, and triglycerides was observed, as was an increase in calcium and vitamin D intake. The multiple regression analysis showed that changes in body mass index, triceps skinfold, waist circumference and triglyceride levels after nutritional intervention were positively associated with changes in anthropometric (loss of body weight) and biochemical (decrease of TG/HDL-c ratio) parameters. Moreover, waist circumference changes were negatively associated with changes in calcium and vitamin D intake. Conclusion: Short-term nutritional counseling improved some factors of metabolic syndrome. Moreover, the increases in calcium and vitamin D consumption can be associated with the improvement in markers of metabolic syndrome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Test templates and a test template framework are introduced as useful concepts in specification-based testing. The framework can be defined using any model-based specification notation and used to derive tests from model-based specifications-in this paper, it is demonstrated using the Z notation. The framework formally defines test data sets and their relation to the operations in a specification and to other test data sets, providing structure to the testing process. Flexibility is preserved, so that many testing strategies can be used. Important application areas of the framework are discussed, including refinement of test data, regression testing, and test oracles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The optimal dosing schedule for melphalan therapy of recurrent malignant melanoma in isolated limb perfusions has been examined using a physiological pharmacokinetic model with data from isolated rat hindlimb perfusions (IRHP), The study included a comparison of melphalan distribution in IRHP under hyperthermia and normothermia conditions. Rat hindlimbs were perfused with Krebs-Henseleit buffer containing 4.7% bovine serum albumin at 37 or 41.5 degrees C at a flow rate of 4 ml/min. Concentrations of melphalan in perfusate and tissues were determined by high performance liquid chromatography with fluorescence detection, The concentration of melphalan in perfusate and tissues was linearly related to the input concentration. The rate and amount of melphalan uptake into the different tissues was higher at 41.5 degrees C than at 37 degrees C. A physiological pharmacokinetic model was validated from the tissue and perfusate time course of melphalan after melphalan perfusion. Application of the model involved the amount of melphalan exposure in the muscle, skin and fat in a recirculation system was related to the method of melphalan administration: single bolus > divided bolus > infusion, The peak concentration of melphalan in the perfusate was also related to the method of administration in the same order, Infusing the total dose of melphalan over 20 min during a 60 min perfusion optimized the exposure of tissues to melphalan whilst minimizing the peak perfusate concentration of melphalan. It is suggested that this method of melphalan administration may be preferable to other methods in terms of optimizing the efficacy of melphalan whilst minimizing the limb toxicity associated with its use in isolated limb perfusion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The aim of this in vitro study was to analyze the effect of glass-ionomer cement as a liner on the dentin/resin adhesive interface of lateral walls of occlusal restorations after thermocycling. Materials and Methods: Occlusal cavities were prepared in 60 human molars, divided into six groups: no liner (1 and 4); glass-ionomer cement (GIC, Ketac Molar Easymix, 3M ESPE) (2 and 5); and resin-modified glass-ionomer cement (RMGIC, Vitrebond, 3M ESPE) (3 and 6). Resin composite (Filtek Z250, 3M ESPE) was placed after application of an adhesive system (Adper Single Bond 2, 3M ESPE) that was mixed with a fluorescent reagent (Rhodamine B) to allow confocal microscopy analysis. Specimens of groups 4, 5 and 6 were thermocycled (5 degrees C-55 degrees C) with a dwell time of 30 seconds for 5000 cycles. After this period, teeth were sectioned in approximately 0.8-mm slices. One slice of each tooth was randomly selected for confocal microscopy analysis. The other slices were sectioned into 0.8 nun x 0.8 mm beams, which were submitted to microtensile testing (MPa). Data were analyzed using two-way ANOVA and Tukey test (p < 0.05). Results: There was no detectedstatistical difference on bond strength among groups (alpha < 0.05). Confocal microscopy analysis showed a higher mean gap size in group 4(12.5 mu m) and a higher percentage of marginal gaps in the thermocycled groups. The RNIGIC liner groups showed the lowest percentage of marginal gaps. Conclusions: Lining with RMGIC resulted in less gap formation at the dentin/resin adhesive interface after artificial aging. RMGIC or GIC liners did not alter the microtensile bond strength of adhesive system/resin composite to dentin on the lateral walls of Class I restorations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Australian funnel-web spiders are recognized as one of the most venomous spiders to humans world-wide. Funnel-web spider antivenom (FWS AV) reverses clinical effects of envenomation from the bite of Atrax robustus and a small number of related Hadronyche species. This study assessed the in vitro efficacy of FWS AV in neutralization of the effects of funnel-web spider venoms, collected from various locations along the eastern seaboard of Australia, in an isolated chick biventer cervicis nerve-muscle preparation. Venoms were separated by SDS-PAGE electrophoresis to compare protein composition and transblotted for Western blotting and incubation with FWS AV. SDS-PAGE of venoms revealed similar low and high molecular weight protein bands. Western blotting with FWS AV showed similar antivenom binding with protein bands in all the venoms tested. Male funnel-web spider venoms (7/7) and female venoms (5110) produced muscle contracture and fasciculation when applied to the nerve-muscle preparation. Venom effects were reversed by subsequent application of FWS AV or prevented by pretreatment of the preparation with antivenom. FWS AV appears to reverse the in vitro toxicity of a number of funnel-web spider venoms from the eastern seaboard of Australia. FWS AV should be effective in the treatment of envenomation from most, if not all, species of Australian funnel-web spiders. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Part 1 of this paper a methodology for back-to-back testing of simulation software was described. Residuals with error-dependent geometric properties were generated. A set of potential coding errors was enumerated, along with a corresponding set of feature matrices, which describe the geometric properties imposed on the residuals by each of the errors. In this part of the paper, an algorithm is developed to isolate the coding errors present by analysing the residuals. A set of errors is isolated when the subspace spanned by their combined feature matrices corresponds to that of the residuals. Individual feature matrices are compared to the residuals and classified as 'definite', 'possible' or 'impossible'. The status of 'possible' errors is resolved using a dynamic subset testing algorithm. To demonstrate and validate the testing methodology presented in Part 1 and the isolation algorithm presented in Part 2, a case study is presented using a model for biological wastewater treatment. Both single and simultaneous errors that are deliberately introduced into the simulation code are correctly detected and isolated. Copyright (C) 2003 John Wiley Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Relatório Final de Estágio apresentado à Escola Superior de Dança, com vista à obtenção do grau de Mestre em Ensino de Dança.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do Grau de Mestre em Engenharia Química e Biológica

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trabalho apresentado no âmbito do Mestrado em Engenharia Informática, como requisito parcial para obtenção do grau de Mestre em Engenharia Informática

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mestrado em Engenharia Informática - Área de Especialização em Tecnologias do Conhecimento e Decisão

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nos últimos anos, o processo de ensino e aprendizagem tem sofrido significativas alterações graças ao aparecimento da Internet. Novas ferramentas para apoio ao ensino têm surgido, nas quais se destacam os laboratórios remotos. Atualmente, muitas instituições de ensino disponibilizam laboratórios remotos nos seus cursos, que permitem, a professores e alunos, a realização de experiências reais através da Internet. Estes são implementados por diferentes arquiteturas e infraestruturas, suportados por vários módulos de laboratório acessíveis remotamente (e.g. instrumentos de medição). No entanto, a sua inclusão no ensino é ainda deficitária, devido: i) à falta de meios e competências técnicas das instituições de ensino para os desenvolverem, ii) à dificuldade na partilha dos módulos de laboratório por diferentes infraestruturas e, iii) à reduzida capacidade de os reconfigurar com esses módulos. Para ultrapassar estas limitações, foi idealizado e desenvolvido no âmbito de um trabalho de doutoramento [1] um protótipo, cuja arquitetura é baseada na norma IEEE 1451.0 e na tecnologia de FPGAs. Para além de garantir o desenvolvimento e o acesso de forma normalizada a um laboratório remoto, este protótipo promove ainda a partilha de módulos de laboratório por diferentes infraestruturas. Nesse trabalho explorou-se a capacidade de reconfiguração de FPGAs para embutir na infraestrutura do laboratório vários módulos, todos descritos em ficheiros, utilizando linguagens de descrição de hardware estruturados de acordo com a norma IEEE 1451.0. A definição desses módulos obriga à criação de estruturas de dados binárias (Transducer Electronic Data Sheets, TEDSs), bem como de outros ficheiros que possibilitam a sua interligação com a infraestrutura do laboratório. No entanto, a criação destes ficheiros é bastante complexa, uma vez que exige a realização de vários cálculos e conversões. Tendo em consideração essa mesma complexidade, esta dissertação descreve o desenvolvimento de uma aplicação Web para leitura e escrita dos TEDSs. Para além de um estudo sobre os laboratórios remotos, é efetuada uma descrição da norma IEEE 1451.0, com particular atenção para a sua arquitetura e para a estrutura dos diferentes TEDSs. Com o objetivo de enquadrar a aplicação desenvolvida, efetua-se ainda uma breve apresentação de um protótipo de um laboratório remoto reconfigurável, cuja reconfiguração é apoiada por esta aplicação. Por fim, é descrita a verificação da aplicação Web, de forma a tirar conclusões sobre o seu contributo para a simplificação dessa reconfiguração.