989 resultados para direct determination
Resumo:
The present work develops and optimizes a method to determine copper in samples of feces and fish feed by graphite furnace atomic absorption spectrometry (GFAAS) through the direct introduction of slurries of the samples into the spectrometer's graphite tube coated internally with metallic rhodium and tungsten carbide that acts as chemical modifiers. The limits of detection (LOD) and quantification (LOQ) calculated for 20 readings of the blank of the standard slurries (0.50% m/v of feces or feed devoid of copper) were 0.24 and 0.79 μg L -1 for the standard feces slurries and 0.26 and 0.87 μg L -1 for the standard feed slurries. The proposed method was applied in studies of absorption of copper in different fish feeds and their results proved compatible with that obtained from samples mineralized by acid digestion using microwave oven. © Springer Science+Business Media, LLC 2008.
Resumo:
Purpose: This study aims to analyze the soursop and sugar apple seeds as to its composition, to evaluate the antioxidant potential of seeds extract and characterize the oil extracted from them, regarding the fatty acids profile and content of tocopherols. Design/methodology/approach: To obtain the extracts, dried and crushed seeds were extracted with ethanol for 30 minutes, at a ratio of 1:3 (m/m, seed: ethyl alcohol) under continuous stirring at room temperature. Then, the mixture was filtered and the supernatants subjected to rotoevaporator at 40°C aiming to determine, by direct weighing, the yields of dry extracts. Findings: According to the results, the soursop and sugar apple seeds constituted significant sources of lipids, proteins and carbohydrates and can therefore be used in food and feed, and offer relevant antioxidant activity of phenolic compounds. The oil seeds are a good source of unsaturated fatty acids, especially oleic and linoleic acids and they have significant amounts of total tocopherol. Research limitations/implications: Implications are the identification of bioactive compounds extracted from seeds of tropical and subtropical fruits, and to prevent certain types of diseases. Practical implications: The information presented might be directly used for developing of functional foods such as fruits. Originality/value: The article tries to identify new source of compounds extracted from fruits. © Emerald Group Publishing Limited.
Resumo:
The identities and quantities of the phenolic compounds and coumarins in twelve samples of sugar cane spirit aged in Quercus sp., Amburana cearensis, Cariniana legalis, Castanea sativa Mill, Ocotea sp., Cotyledon orbiculata L., and Hymenaea sp. casks were determined. These compounds have a direct influence on the sensory characteristics of aged beverages; some of them are considered to be markers for the aging process. The analysis of phenolic compounds was performed by HPLC. Solid phase extraction (SPE) was also used for the determination of coumarins. The concentrations of the principal compounds extracted varied according to the species of wood. The concentrations of total phenolic compounds ranged from 0.08 for a sample stored in a 4000-L jatobá barrel for a period of six months to 40.9 mg · L−1 for a sample aged in a 50000-L oak barrel for a period of 48 months. The use of the SPE technique removed interfering compounds from the samples, thereby improving the detection of coumarin.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background. Methods for determining the root canal length of the primary tooth should yield accurate and reproducible results. In vitro studies show some limitations, which do not allow their findings to be directly transferred to a clinical situation. Aim. To compare the accuracy of radiographic tooth length obtained from in vivo digital radiograph with that obtained from ex vivo digital radiograph. Method. Direct digital radiographs of 20 upper primary incisors were performed in teeth (2/3 radicular resorption) that were radiographed by an intraoral sensor, according to the long-cone technique. Teeth were extracted, measured, and mounted in a resin block, and then radiographic template was used to standardise the sensor-target distance (30 cm). The apparent tooth length (APTL) was obtained from the computer screen by means of an electronic ruler accompanying the digital radiography software (CDR 2.0), whereas the actual tooth length (ACTL) was obtained by means of a digital calliper following extraction. Data were compared to the ACTL by variance analysis and Pearson’s correlation test. Results. The values for APTL obtained from in vivo radiography were slightly underestimated, whereas those values obtained from ex vivo were slightly overestimated. No significance was observed between APTL and ACTL. Conclusion. The length of primary teeth estimated by in vivo and ex vivo comparisons using digital radiography was found to be similar to the actual tooth length.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Potassium fluorrichterite (KNaCaMg5Si8O22F2) glass-ceramics were modified by either increasing the concentration of calcium (GC5) or by the addition of P2O5 (GP2). Rods (2 x 4 mm) of stoichiometric fluorrichterite (GST), modified compositions (GC5 and GP2) and 45S5 bioglass, which was used as the reference material, were prepared using a conventional lost-wax technique. Osteoconductivity was investigated by implantation into healing defects in the midshaft of rabbit femora. Specimens were harvested at 4 and 12 weeks following implantation and tissue response was investigated using computed microtomography (mu CT) and histological analyses. The results showed greatest bone to implant contact in the 45S5 bioglass reference material at 4 and 12 weeks following implantation, however, GST, GC5 and GP2 all showed direct bone tissue contact with evidence of new bone formation and cell proliferation along the implant surface into the medullary space. There was no evidence of bone necrosis or fibrous tissue encapsulation around the test specimens. Of the modified potassium fluorrichterite compositions, GP2 showed the greatest promise as a bone substitute material due to its osteoconductive potential and superior mechanical properties.
Resumo:
The present study deals with the determination of the activation energy for the thermal decomposition of two renewable fuels crude glycerin and beef tallow. The activation energies were investigated by using a thermogravimetric analyzer (TGA) in the temperature range of 25-600 degrees C in atmosphere of synthetic air. The TG curves of the thermal decomposition process of both samples were divided into several phases and the second, called PH2, was chosen for the kinetic study because it is associated with the combustion ignition. Differential Thermal Analysis (DTA) showed an endothermic event at the PH2 region for the crude glycerin corresponding to devolatilization, while for beef tallow, this step presented an exothermic event, called LTO (low-temperature oxidation), which is correlated with devolatilization followed by combustion. For the entire PH2, activation energy values for crude glycerin were between 90 kJ mol(-1) and 42 kJ mol(-1), while for the beef tallow they ranged from 50 kJ mol(-1) to 113 kJ mol (1). The activation energy values obtained at the pre-ignition stage - conversion between 0 and 0.45 - showed that the crude glycerin with higher values requires an additional energetic support at the start of combustion processes and the beef tallow ignites more easily, presenting lower values. According to the Wolfer's equation, a direct relation between the activation energy and the ignition delay is established and the results of this study provides useful data for the development and design of new combustion chambers and engines when non-traditional fuels are used as feedstock. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
The reproductive performance of cattle may be influenced by several factors, but mineral imbalances are crucial in terms of direct effects on reproduction. Several studies have shown that elements such as calcium, copper, iron, magnesium, selenium, and zinc are essential for reproduction and can prevent oxidative stress. However, toxic elements such as lead, nickel, and arsenic can have adverse effects on reproduction. In this paper, we applied a simple and fast method of multi-element analysis to bovine semen samples from Zebu and European classes used in reproduction programs and artificial insemination. Samples were analyzed by inductively coupled plasma spectrometry (ICP-MS) using aqueous medium calibration and the samples were diluted in a proportion of 1:50 in a solution containing 0.01% (vol/vol) Triton X-100 and 0.5% (vol/vol) nitric acid. Rhodium, iridium, and yttrium were used as the internal standards for ICP-MS analysis. To develop a reliable method of tracing the class of bovine semen, we used data mining techniques that make it possible to classify unknown samples after checking the differentiation of known-class samples. Based on the determination of 15 elements in 41 samples of bovine semen, 3 machine-learning tools for classification were applied to determine cattle class. Our results demonstrate the potential of support vector machine (SVM), multilayer perceptron (MLP), and random forest (RF) chemometric tools to identify cattle class. Moreover, the selection tools made it possible to reduce the number of chemical elements needed from 15 to just 8.
Resumo:
In this work, a LED (light emitting diode) based photometer for solid phase photometry is described. The photometer was designed to permit direct coupling of a light source (LED) and a photodiode to a flow cell with an optical pathlength of 4 mm. The flow cell was filled with adsorbing solid phase material (C-18), which was used to immobilize the chromogenic reagent 1-(2-thiazolylazo)-2-naphthol (TAN). Aiming to allow accuracy assessment, samples were also analyzed employing ICP OES (inductively coupled plasma optical emission spectrometry) methodology. Applying the paired t-test at the 95% confidence level, no significant difference was observed. Other useful features were also achieved: linear response ranging from 0.05 to 0.85 mg L-1 Zn, limit of detection of 9 mu g L-1 Zn (3 sigma criterion), standard deviation of 1.4% (n = 10), sampling throughput of 36 determinations per h, and a waste generation and reagent consumption of 1.7 mL and of 0.03 mu g per determination, respectively.
Resumo:
[EN]Until recently, sample preparation was carried out using traditional techniques, such as liquid–liquid extraction (LLE), that use large volumes of organic solvents. Solid-phase extraction (SPE) uses much less solvent than LLE, although the volume can still be significant. These preparation methods are expensive, time-consuming and environmentally unfriendly. Recently, a great effort has been made to develop new analytical methodologies able to perform direct analyses using miniaturised equipment, thereby achieving high enrichment factors, minimising solvent consumption and reducing waste. These microextraction techniques improve the performance during sample preparation, particularly in complex water environmental samples, such as wastewaters, surface and ground waters, tap waters, sea and river waters. Liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS) and time-of-flight mass spectrometric (TOF/MS) techniques can be used when analysing a broad range of organic micropollutants. Before separating and detecting these compounds in environmental samples, the target analytes must be extracted and pre-concentrated to make them detectable. In this work, we review the most recent applications of microextraction preparation techniques in different water environmental matrices to determine organic micropollutants: solid-phase microextraction SPME, in-tube solid-phase microextraction (IT-SPME), stir bar sorptive extraction (SBSE) and liquid-phase microextraction (LPME). Several groups of compounds are considered organic micropollutants because these are being released continuously into the environment. Many of these compounds are considered emerging contaminants. These analytes are generally compounds that are not covered by the existing regulations and are now detected more frequently in different environmental compartments. Pharmaceuticals, surfactants, personal care products and other chemicals are considered micropollutants. These compounds must be monitored because, although they are detected in low concentrations, they might be harmful toward ecosystems.