990 resultados para bone quality


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bone marrow is a target organ site involved in multiple diseases including myeloproliferative disorders and hematologic malignancies and metastases from breast and prostate. Most of these diseases are characterized with poor quality of life, and the treatment options are only palliative due to lack of delivery mechanisms for systemically injected drugs which results in dose limitation to protect the healthy hematopoietic cells. Therefore, there is a critical need to develop effective therapeutic strategies that allow for selective delivery of therapeutic payload to the bone marrow. Nanotechnology-based drug delivery systems provide the opportunity to deliver drugs to the target tissue while decreasing exposure to normal tissues. E-selectin is constitutively expressed on the bone marrow vasculature, but almost absent in normal vessels, and therefore, E-selectin targeted drug delivery presents an ideal strategy for the delivery of therapeutic nanoparticles to the bone marrow. The objective of this study was to develop a novel bone marrow targeted multistage vector (MSV) via E-selectin for delivery of therapeutics and imaging agents. To achieve this goal, Firstly, an E-selectin thioaptamer (ESTA) ligand was identified through a two-step screening from a combinatorial thioaptamer library. Next, ESTA-conjugated MSV (ESTA-MSV) were developed and evaluated for their stability and binding to E-selectin expressing endothelial cells. Different types of nanoparticles including liposomes, quantum dots, and iron oxide nanoparticles were loaded into the porous structure of ESTA-MSV. In vivo targeting experiments demonstrated 8-fold higher accumulation of ESTA-MSV in the mouse bone marrow as compared to non-targeted MSV Furthermore, intravenous injection of liposomes loaded ESTA-MSV resulted in a significantly higher accumulation of liposome in the bone marrow space as compared to injection of non-targeted MSV or liposomes alone. Overall this study provides first evidence that E-selectin targeted multistage vector preferentially targets to bone marrow vasculature and delivers larger amounts of nanoparticles. This delivery strategy holds potential for the selective delivery of large amounts of therapeutic payload to the vascular niches in the bone marrow for the treatment of bone marrow associated diseases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction The purpose of this paper is to present the technical specifications of the Forensic Reference Phantom (FRP), to test its behavior relative to organic test materials, and discuss potential applications of the phantom in forensic radiology. Materials and method The FRP prototype is made of synthetic materials designed to simulate the computed tomography (CT) attenuation of water. It has six bore holes that accommodate multiuse containers. These containers were filled with test materials and scanned at 80 kVp, 120 kVp, and 140 kVp. X-ray attenuation was measured by two readers. Intra- and inter-reader reliability was assessed using the intra-class correlation coefficient (ICC). Significance levels between mean CT numbers at 80 kVp, 120 kVp, and 140 kVp were assessed with the Friedman-test. The T-test was used to assess significance levels between the FRP and water. Results Overall mean CT numbers ranged from −3.0–3.7HU for the FRP; −1000.3–−993.5HU for air; −157.7– −108.1HU for oil; 35.5–42.0HU for musle tissue; and 1301.5–2354.8HU for cortical bone. Inter-reader and intra-reader reliability were excellent (ICC>0.994; and ICC=0.999 respectively). CT numbers were significantly different at different energy levels. There was no significant difference between the attenuation of the FRP and water. Conclusions The FRP is a new tool for quality assurance and research in forensic radiology. The mean CT attenuation of the FRP is equivalent to water. The phantom can be scanned during routine post-mortem CT to assess the composition of unidentified objects. In addition, the FRP may be used to investigate new imaging algorithms and scan protocols in forensic radiology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE The aim of the present study was to evaluate a dose reduction in contrast-enhanced chest computed tomography (CT) by comparing the three latest generations of Siemens CT scanners used in clinical practice. We analyzed the amount of radiation used with filtered back projection (FBP) and an iterative reconstruction (IR) algorithm to yield the same image quality. Furthermore, the influence on the radiation dose of the most recent integrated circuit detector (ICD; Stellar detector, Siemens Healthcare, Erlangen, Germany) was investigated. MATERIALS AND METHODS 136 Patients were included. Scan parameters were set to a thorax routine: SOMATOM Sensation 64 (FBP), SOMATOM Definition Flash (IR), and SOMATOM Definition Edge (ICD and IR). Tube current was set constantly to the reference level of 100 mA automated tube current modulation using reference milliamperes. Care kV was used on the Flash and Edge scanner, while tube potential was individually selected between 100 and 140 kVp by the medical technologists at the SOMATOM Sensation. Quality assessment was performed on soft-tissue kernel reconstruction. Dose was represented by the dose length product. RESULTS Dose-length product (DLP) with FBP for the average chest CT was 308 mGy*cm ± 99.6. In contrast, the DLP for the chest CT with IR algorithm was 196.8 mGy*cm ± 68.8 (P = 0.0001). Further decline in dose can be noted with IR and the ICD: DLP: 166.4 mGy*cm ± 54.5 (P = 0.033). The dose reduction compared to FBP was 36.1% with IR and 45.6% with IR/ICD. Signal-to-noise ratio (SNR) was favorable in the aorta, bone, and soft tissue for IR/ICD in combination compared to FBP (the P values ranged from 0.003 to 0.048). Overall contrast-to-noise ratio (CNR) improved with declining DLP. CONCLUSION The most recent technical developments, namely IR in combination with integrated circuit detectors, can significantly lower radiation dose in chest CT examinations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Keel bone damage (KBD) is a critical issue facing the laying hen industry today as a result of the likely pain leading to compromised welfare and the potential for reduced productivity. Recent reports suggest that damage, while highly variable and likely dependent on a host of factors, extends to all systems (including battery cages, furnished cages, and non-cage systems), genetic lines, and management styles. Despite the extent of the problem, the research community remains uncertain as to the causes and influencing factors of KBD. Although progress has been made investigating these factors, the overall effort is hindered by several issues related to the assessment of KBD, including quality and variation in the methods used between research groups. These issues prevent effective comparison of studies, as well as difficulties in identifying the presence of damage leading to poor accuracy and reliability. The current manuscript seeks to resolve these issues by offering precise definitions for types of KBD, reviewing methods for assessment, and providing recommendations that can improve the accuracy and reliability of those assessments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bisphosphonates have proven effectiveness in preventing skeletal-related events (SREs) in advanced breast cancer, prostate cancer and multiple myeloma. The purpose of this study was to assess efficacy of bisphosphonates in preventing SREs, in controlling pain, and in increasing life expectancy in lung cancer patients with bone metastases.^ We performed an electronic search in MEDLINE, EMBASE, Web of Science, and Cochrane library databases up to April 4, 2010. Hand searching and searching in clinicaltrials.gov were also performed. Two independent reviewers selected all clinical trials that included lung cancer patients with bone metastases treated with bisphosphonates. We excluded articles that involved cancers other than lung, patients without bone metastasis and treatment other than bisphosphonates. Outcome questions answered were efficacy measured as overall pain control, overall improvement in survival and reduction in skeletal-related events or SREs (fracture, cord compression, radiation or surgery to the bone, hypercalcemia of malignancy). The quality of each study was evaluated using the Cochrane Back Review group questionnaire to assess risk of bias (0-worst to 11-best). Data extraction and quality assessments were independently performed by two assessors. Meta-analyses were performed where more than one study with similar outcomes were found.^ We identified eight trials that met our inclusion criteria. Three studies evaluated zoledronic acid, three pamidronate, three clodronate and two ibandronate. Two were placebocontrol trials while two had multi-group comparisons (radiotherapy, radionucleotides, and chemotherapy) and two had different bisphosphonate as active controls. Quality scores ranged from 1-4 out of 11 suggesting high risk of bias. Studies failed to report adequate explanation of randomization procedures, concealment of randomization and blinding. Metaanalysis showed that patients treated with zoledronic acid alone had lower rates of developing SREs compared to placebo at 21 months (RR=0.80, 95% CI=0.66-0.97, p=0.02). Meta-analyses also showed increased pain control when a bisphosphonate was added to the existing treatment modality like chemotherapy or radiation (RR=1.17, 95% CI=1.03-1.34, p=0.02). However, pain control was not statistically significantly different among various bisphosphonates when other treatment modalities were not present. Despite improvement in SRE and pain control, bisphosphonates failed to show improvement in overall survival (Difference in means=109.1 days, 95% CI= -51.52 – 269.71, p=0.183).^ Adding biphosphonates to standard care improved pain control and reduced SREs. Biphosphonates did not improve overall survival. Further larger studies with higher quality are required to stengthen the evidence.^ Keywords/MeSH terms Bisphosphonates/diphosphonates: generic, chemical and trade names.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The prevalence of keel bone damage as well as external egg parameters of 2 pure lines divergently selected for high (H) and low (L) bone strength were investigated in 2 aviary systems under commercial conditions. A standard LSL hybrid was used as a reference group. Birds were kept mixed per genetic line (77 hens of the H and L line and 201 or 206 hens of the LSL line, respectively, per pen) in 8 pens of 2 aviary systems differing in design. Keel bone status and body mass of 20 focal hens per line and pen were assessed at 17, 18, 23, 30, 36, 43, 52, and 63 wk of age. External egg parameters (i.e., egg mass, eggshell breaking strength, thickness, and mass) were measured using 10 eggs per line at both 38 and 57 wk of age. Body parameters (i.e. tarsus and third primary wing feather length to calculate index of wing loading) were recorded at 38 wk of age and mortality per genetic line throughout the laying cycle. Bone mineral density (BMD) of 15 keel bones per genetic line was measured after slaughter to confirm assignment of the experimental lines. We found a greater BMD in the H compared with the L and LSL lines. Fewer keel bone fractures and deviations, a poorer external egg quality, as well as a lower index of wing loading were found in the H compared with the L line. Mortality was lower and production parameters (e.g., laying performance) were higher in the LSL line compared with the 2 experimental lines. Aviary design affected prevalence of keel bone damage, body mass, and mortality. We conclude that selection of specific bone traits associated with bone strength as well as the related differences in body morphology (i.e., lower index of wing loading) have potential to reduce keel bone damage in commercial settings. Also, the housing environment (i.e., aviary design) may have additive effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this investigation was to evaluate the impact of undertaking peripheral blood stem cell transplantation (PBST) on quality of life (QoL), and to determine the effect of participating in a mixed-type, moderate-intensity exercise program on QoL. It was also an objective to determine the relationship between peak aerobic capacity and QoL in PBST patients. QoL was assessed via the CARES questionnaire and peak aerobic capacity by a maximal graded treadmill test, pretransplant (PI), post transplant (PII) and following a 12-week intervention period (PIII). At PII, 12 patients were divided equally into a control or exercise intervention group. Undergoing a PBST was associated with a statistically but not clinically significant decline in QoL (P < 0.05). Following the intervention, exercising patients demonstrated an improved QoL when compared with pretransplant ratings (P < 0.01) and nonexercising transplant patients (P < 0.05). Moreover, peak aerobic capacity and QoL were correlated (P < 0.05). The findings demonstrated that exercise participation following oncology treatment is associated with a reduction in the number and severity of endorsed problems, which in turn leads to improvements in global, physical and psychosocial QoL. Furthermore, a relationship between fitness and QoL exists, with those experiencing higher levels of fitness also demonstrating higher QoL.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For several decades, a dose of 25 kGy of gamma irradiation has been recommended for terminal sterilization of medical products, including bone allografts. Practically, the application of a given gamma dose varies from tissue bank to tissue bank. While many banks use 25 kGy, some have adopted a higher dose, while some choose lower doses, and others do not use irradiation for terminal sterilization. A revolution in quality control in the tissue banking industry has occurred in line with development of quality assurance standards. These have resulted in significant reductions in the risk of contamination by microorganisms of final graft products. In light of these developments, there is sufficient rationale to re-establish a new standard dose, sufficient enough to sterilize allograft bone, while minimizing the adverse effects of gamma radiation on tissue properties. Using valid modifications, several authors have applied ISO standards to establish a radiation dose for bone allografts that is specific to systems employed in bone banking. These standards, and their verification, suggest that the actual dose could be significantly reduced from 25 kGy, while maintaining a valid sterility assurance level (SAL) of 10−6. The current paper reviews the methods that have been used to develop radiation doses for terminal sterilization of medical products, and the current trend for selection of a specific dose for tissue banks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

FUNDING & ACKNOWLEDGEMENTS This project was funded by the NIHR Health Technology Assessment programme (project number 05/47/02) and is published in full in Health Technology Assessment; Vol. 19, No. 80. Further information available at: http://www.nets.nihr.ac.uk/projects/hta/054702 This paper presents independent research commissioned by the National Institute for Health Research (NIHR). The views and opinions expressed by authors in this publication are those of the authors and do not necessarily reflect those of the NHS, the NIHR, MRC, CCF, NETSCC, the HTA programme or the Department of Health. Due to the confidential nature of the trial data supporting this publication not all of the data can be made accessible to other researchers. Please contact the UKUFF study principal investigator Andrew Carr (andrew.carr@ndorms.ox.ac.uk) for more information. The authors wish to thank the UKUFF trial collaborators for their contribution in managing the conduct of the trial, and for their comments on the interim economic results: Marion Campbell and Hannah Bruhn (Centre for Healthcare Randomised Trials, HSRU, University of Aberdeen), Jonathan Rees MD and David Beard (NDORMS, University of Oxford; NIHR Oxford Biomedical Research Centre), Jane Moser (NDORMS, University of Oxford), Raymond Fitzpatrick and Jill Dawson (NDPH, University of Oxford).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the cell therapy industry continuing to grow, the ability to preserve clinical grade cells, including mesenchymal stem cells (MSCs), whilst retaining cell viability and function remains critical for the generation of off-the-shelf therapies. Cryopreservation of MSCs, using slow freezing, is an established process at lab scale. However, the cytotoxicity of cryoprotectants, like Me2SO, raises questions about the impact of prolonged cell exposure to cryoprotectant at temperatures >0 °C during processing of large cell batches for allogenic therapies prior to rapid cooling in a controlled rate freezer or in the clinic prior to administration. Here we show that exposure of human bone marrow derived MSCs to Me2SO for ≥1 h before freezing, or after thawing, degrades membrane integrity, short-term cell attachment efficiency and alters cell immunophenotype. After 2 h's exposure to Me2SO at 37 °C post-thaw, membrane integrity dropped to ∼70% and only ∼50% of cells retained the ability to adhere to tissue culture plastic. Furthermore, only 70% of the recovered MSCs retained an immunophenotype consistent with the ISCT minimal criteria after exposure. We also saw a similar loss of membrane integrity and attachment efficiency after exposing osteoblast (HOS TE85) cells to Me2SO before, and after, cryopreservation. Overall, these results show that freezing medium exposure is a critical determinant of product quality as process scale increases. Defining and reporting cell sensitivity to freezing medium exposure, both before and after cryopreservation, enables a fair judgement of how scalable a particular cryopreservation process can be, and consequently whether the therapy has commercial feasibility.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the cost-effectiveness of adding zoledronic acid or strontium-89 to standard docetaxel chemotherapy for patients with castrate-refractory prostate cancer (CRPC).

PATIENTS AND METHODS: Data on resource use and quality of life for 707 patients collected prospectively in the TRAPEZE 2 × 2 factorial randomised trial (ISRCTN 12808747) were used to assess the cost-effectiveness of i) zoledronic acid versus no zoledronic acid (ZA vs. no ZA), and ii) strontium-89 versus no strontium-89 (Sr89 vs. no Sr89). Costs were estimated from the perspective of the National Health Service in the UK and included expenditures for trial treatments, concomitant medications, and use of related hospital and primary care services. Quality-adjusted life-years (QALYs) were calculated according to patients' responses to the generic EuroQol EQ-5D-3L instrument, which evaluates health status. Results are expressed as incremental cost-effectiveness ratios (ICERs) and cost-effectiveness acceptability curves.

RESULTS: The per-patient cost for ZA was £12 667, £251 higher than the equivalent cost in the no ZA group. Patients in the ZA group had on average 0.03 QALYs more than their counterparts in no ZA group. The ICER for this comparison was £8 005. Sr89 was associated with a cost of £13 230, £1365 higher than no Sr89, and a gain of 0.08 QALYs compared to no Sr89. The ICER for Sr89 was £16 884. The probabilities of ZA and Sr89 being cost-effective were 0.64 and 0.60, respectively.

CONCLUSIONS: The addition of bone-targeting treatments to standard chemotherapy led to a small improvement in QALYs for a modest increase in cost (or cost-savings). ZA and Sr89 resulted in ICERs below conventional willingness-to-pay per QALY thresholds, suggesting that their addition to chemotherapy may represent a cost-effective use of resources.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Radium-223 dichloride (radium-223), a first-in-class α-emitting radiopharmaceutical, is recommended in both pre- and post-docetaxel settings in patients with castration-resistant prostate cancer (CRPC) and symptomatic bone metastases based on overall survival benefit demonstrated in the phase III ALSYMPCA study. ALSYMPCA included prospective measurements of health-related quality of life (QOL) using two validated instruments: the general EuroQoL 5D (EQ-5D) and the disease-specific Functional Assessment of Cancer Therapy-Prostate (FACT-P).

PATIENTS AND METHODS: Analyses were conducted to determine treatment effects of radium-223 plus standard of care (SOC) versus placebo plus SOC on QOL using FACT-P and EQ-5D. Outcomes assessed were percentage of patients experiencing improvement, percentage of patients experiencing worsening, and mean QOL scores during the study.

RESULTS: Analyses were carried out on the intent-to-treat population of patients randomized to receive radium-223 (n = 614) or placebo (n = 307). The mean baseline EQ-5D utility and FACT-P total scores were similar between treatment groups. A significantly higher percentage of patients receiving radium-223 experienced meaningful improvement in EQ-5D utility score on treatment versus placebo {29.2% versus 18.5%, respectively; P = 0.004; odds ratio (OR) = 1.82 [95% confidence interval (CI) 1.21-2.74]}. Findings were similar for FACT-P total score [24.6% versus 16.1%, respectively; P = 0.020; OR = 1.70 (95% CI 1.08-2.65)]. A lower percentage of patients receiving radium-223 experienced meaningful worsening versus placebo measured by EQ-5D utility score and FACT-P total score. Prior docetaxel use and current bisphosphonate use did not affect these findings. Treatment was a significant predictor of EQ-5D utility score, with radium-223 associated with higher scores versus placebo (0.56 versus 0.50, respectively; P = 0.002). Findings were similar for FACT-P total score (99.08 versus 95.22, respectively; P = 0.004).

CONCLUSIONS: QOL data from ALSYMPCA demonstrated that improved survival with radium-223 is accompanied by significant QOL benefits, including a higher percentage of patients with meaningful QOL improvement and a slower decline in QOL over time in patients with CRPC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For in vitro differentiation of bone marrow-derived mesenchymal stem cells/mesenchymal stromal cells into osteoblasts by 2-dimensional cell culture a variety of protocols have been used and evaluated in the past. Especially the external phosphate source used to induce mineralization varies considerably both in respect to chemical composition and concentration. In light of the recent findings that inorganic phosphate directs gene expression of genes crucial for bone development, the need for a standardized phosphate source in in vitro differentiation becomes apparent. We show that chemical composition (inorganic versus organic phosphate origin) and concentration of phosphate supplementation exert a severe impact on the results of gene expression for the genes commonly used as markers for osteoblast formation as well as on the composition of the mineral formed. Specifically, the intensity of gene expression does not necessarily correlate with a high quality mineralized matrix. Our study demonstrates advantages of using inorganic phosphate instead of beta-glycerophosphate and propose colorimetric quantification methods for calcium and phosphate ions as cost-and time-effective alternatives to X-ray diffraction and Fourier-transform infrared spectroscopy for determination of the calcium phosphate ratio and concentration of mineral matrix formed under in vitro-conditions. We critically discuss the different assays used to assess in vitro bone formation in respect to specificity and provide a detailed in vitro protocol that could help to avoid contradictory results due to variances in experimental design.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

International audience

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The behaviour of bone tissue during drilling has been subject of recent studies due to its great importance. Because of thermal nature of the bone drilling, high temperatures and thermal mechanical stresses are developed during drilling that affect the process quality. However, there is still a lack information with regard to the distribution of mechanical and thermal stresses during bone drilling. The present paper describes a sequentially coupled thermal-stress analysis to assess the mechanical and thermal stress distribution during bone drilling. A three-dimensional thermo-mechanical model was developed using the ANSYS/LSDYNA finite element code under different drilling conditions. The model incorporates the dynamic characteristics of drilling process, as well as the thermo-mechanical properties of the involved materials. Experimental tests with polyurethane foam materials were also carried out. It was concluded that the use of higher feed-rates lead to a decrease of normal stresses and strains in the foam materials. The experimental and numerical results were compared and showed good agreement. The proposed numerical model could be used to predict the better drilling parameters and minimize the bone injuries.