957 resultados para assessment instrument
Resumo:
OBJECTIVE: To develop and validate a short health literacy assessment tool for Portuguese-speaking adults. METHODS: The Short Assessment of Health Literacy for Portuguese-speaking Adults is an assessment tool which consists of 50 items that assess an individual's ability to correctly pronounce and understand common medical terms. We evaluated the instrument's psychometric properties in a convenience sample of 226 Brazilian older adults. Construct validity was assessed by correlating the tool scores with years of schooling, self-reported literacy, and global cognitive functioning. Discrimination validity was assessed by testing the tool's accuracy in detecting inadequate health literacy, defined as failure to fully understand standard medical prescriptions. RESULTS: Moderate to high correlations were found in the assessment of construct validity (Spearman's coefficients ranging from 0.63 to 0.76). The instrument showed adequate internal consistency (Cronbach's alpha=0.93) and adequate test-retest reliability (intraclass correlation coefficient=0.95). The area under the receiver operating characteristic curve for detection of inadequate health literacy was 0.82. A version consisting of 18 items was tested and showed similar psychometric properties. CONCLUSIONS: The instrument developed showed good validity and reliability in a sample of Brazilian older adults. It can be used in research and clinical settings for screening inadequate health literacy.
Resumo:
To perform a systematic review of the utility of the Beck Depression Inventory for detecting depression in medical settings, this article focuses on the revised version of the scale (Beck Depression Inventory-II), which was reformulated according to the DSM-IV criteria for major depression. We examined relevant investigations with the Beck Depression Inventory-II for measuring depression in medical settings to provide guidelines for practicing clinicians. Considering the inclusion and exclusion criteria seventy articles were retained. Validation studies of the Beck Depression Inventory-II, in both primary care and hospital settings, were found for clinics of cardiology, neurology, obstetrics, brain injury, nephrology, chronic pain, chronic fatigue, oncology, and infectious disease. The Beck Depression Inventory-II showed high reliability and good correlation with measures of depression and anxiety. Its threshold for detecting depression varied according to the type of patients, suggesting the need for adjusted cut-off points. The somatic and cognitive-affective dimension described the latent structure of the instrument. The Beck Depression Inventory-II can be easily adapted in most clinical conditions for detecting major depression and recommending an appropriate intervention. Although this scale represents a sound path for detecting depression in patients with medical conditions, the clinician should seek evidence for how to interpret the score before using the Beck Depression Inventory-II to make clinical decisions
Resumo:
Spine Tango is the first and only International Spine Registry in operation to date. So far, only surgical spinal interventions have been recorded and no comparable structured and comprehensive documentation instrument for conservative treatments of spinal disorders is available. This study reports on the development of a documentation instrument for the conservative treatment of spinal disorders by using the Delphi consensus method. It was conducted with a group of international experts in the field. We also assessed the usability of this new assessment tool with a prospective feasibility study on 97 outpatients and inpatients with low back or neck pain undergoing conservative treatment. The new 'Spine Tango conservative' questionnaire proved useful and suitable for the documentation of pathologies, conservative treatments and outcomes of patients with low back or neck problems. A follow-up questionnaire seemed less important in the predominantly outpatient setting. In the feasibility study, between 43 and 63% of patients reached the minimal clinically important difference in pain relief and Core Outcome Measures Index at 3 months after therapy; 87% of patients with back pain and 85% with neck pain were satisfied with the received treatment. With 'Spine Tango conservative' a first step has been taken to develop and implement a complementary system for documentation and evaluation of non-surgical spinal interventions and outcomes within the framework of the International Spine Registry. It proved useful and feasible in a first pilot study, but it will take the experience of many more cases and therapists to develop a version similarly mature as the surgical instruments of Spine Tango.
Resumo:
The translation from psychiatric core symptoms to brain functions and vice versa is a largely unresolved issue. In particular, the search for disorders of single brain regions explaining classical symptoms has not yielded the expected results. Based on the assumption that the psychopathology of psychosis is related to a functional imbalance of higher-order brain systems, the authors focused on three specific candidate brain circuitries, namely the language, and limbic and motor systems. These domains are of particular interest for understanding the disastrous communication breakdown during psychotic disorders. Core symptoms of psychosis were mapped on these domains by shaping their definitions in order to match the related brain functions. The resulting psychopathological assessment scale was tested for interrater reliability and internal consistency in a group of 168 psychotic patients. The items of the scale were reliable and a principal component analysis (PCA) was best explained by a solution resembling the three candidate systems. Based on the results, the scale was optimized as an instrument to identify patient subgroups characterized by a prevailing dysfunction of one or more of these systems. In conclusion, the scale is apt to distinguish symptom domains related to the activity of defined brain systems. PCA showed a certain degree of independence of the system-specific symptom clusters within the patient group, indicating relative subgroups of psychosis. The scale is understood as a research instrument to investigate psychoses based on a system-oriented approach. Possible immediate advantages in the clinical application of the understanding of psychoses related to system-specific symptom domains are also discussed.
Resumo:
Data from 50 residents of a long-term care facility were used to examine the extent to which performance on a brief, objective inventory could predict a clinical psychologist's evaluation of competence to participate in decisions about medical care. Results indicate that the competence to participate in medical decisions of two-thirds of the residents could be accurately assessed using scores on a mental status instrument and two vignette-based measures of medical decision-making. These procedures could enable nursing home staff to objectively assess the competence of residents to participate in important decisions about their medical care.
Resumo:
The TROPOspheric Monitoring Instrument (TROPOMI) will be part of ESA's Sentinel-5 Precursor (S5P) satellite platform scheduled for launch in 2015. TROPOMI will monitor methane and carbon monoxide concentrations in the Earth's atmosphere by measuring spectra of back-scattered sunlight in the short-wave infrared (SWIR). S5P will be the first satellite mission to rely uniquely on the spectral window at 4190–4340 cm−1 (2.3 μm) to retrieve CH4 and CO. In this study, we investigated if the absorption features of the three relevant molecules CH4, CO, and H2O are adequately known. To this end, we retrieved total columns of CH4, CO, and H2O from absorption spectra measured by two ground-based Fourier transform spectrometers that are part of the Total Carbon Column Observing Network (TCCON). The retrieval results from the 4190–4340 cm−1 range at the TROPOMI resolution (0.45 cm−1) were then compared to the CH4 results obtained from the 6000 cm−1 region, and the CO results obtained from the 4190–4340 cm−1 region at the higher TCCON resolution (0.02 cm−1). For TROPOMI-like settings, we were able to reproduce the CH4 columns to an accuracy of 0.3% apart from a constant bias of 1%. The CO retrieval accuracy was, through interference, systematically influenced by the shortcomings of the CH4 and H2O spectroscopy. In contrast to CH4, the CO column error also varied significantly with atmospheric H2O content. Unaddressed, this would introduce seasonal and latitudinal biases to the CO columns retrieved from TROPOMI measurements. We therefore recommend further effort from the spectroscopic community to be directed at the H2O and CH4 spectroscopy in the 4190–4340 cm−1 region.
Resumo:
BACKGROUND: High intercoder reliability (ICR) is required in qualitative content analysis for assuring quality when more than one coder is involved in data analysis. The literature is short of standardized procedures for ICR procedures in qualitative content analysis. OBJECTIVE: To illustrate how ICR assessment can be used to improve codings in qualitative content analysis. METHODS: Key steps of the procedure are presented, drawing on data from a qualitative study on patients' perspectives on low back pain. RESULTS: First, a coding scheme was developed using a comprehensive inductive and deductive approach. Second, 10 transcripts were coded independently by two researchers, and ICR was calculated. A resulting kappa value of .67 can be regarded as satisfactory to solid. Moreover, varying agreement rates helped to identify problems in the coding scheme. Low agreement rates, for instance, indicated that respective codes were defined too broadly and would need clarification. In a third step, the results of the analysis were used to improve the coding scheme, leading to consistent and high-quality results. DISCUSSION: The quantitative approach of ICR assessment is a viable instrument for quality assurance in qualitative content analysis. Kappa values and close inspection of agreement rates help to estimate and increase quality of codings. This approach facilitates good practice in coding and enhances credibility of analysis, especially when large samples are interviewed, different coders are involved, and quantitative results are presented.
Resumo:
There is a shortage of empirical applications of the capability approach that employ closed survey instruments to assess self-reported capabilities. However, for those few instruments that have been designed and administered through surveys until now, no psychometric properties (reliability, validity, and factor structure) were reported. The purpose of this study is the assessment of the psychometric properties of three new language versions (German, French, and Italian) of an established (English) set of eight self-reported capability items. The set of items is taken from a previously published British study by Anand and van Hees (J Soc Econ 35(2):268–284, 2006). Our sample consists of 17,152 young male adults aged 18–25 years from the three major language regions in Switzerland. The results indicate good reliability of the three language versions. The results from the exploratory factor analyses suggest a one-dimensional factor structure for seven domain specific items. Furthermore, the results from multiple regression analyses suggest that a global summary item on overall capabilities represents a measurement alternative to the set of seven domain specific capability items. Finally, the results confirm the applicability of the closed capability instrument in a large scale survey questionnaire and represent the first attempt to measure self-reported capabilities in Switzerland.
Resumo:
Context. The abundance of deuterium in the interstellar gas in front of the Sun gives insight into the processes of filtration of neutral interstellar species through the heliospheric interface and potentially into the chemical evolution of the Galactic gas. Aims: We investigate the possibility of detection of neutral interstellar deuterium at 1 AU from the Sun by direct sampling by the Interstellar Boundary Explorer (IBEX). Methods: Using both previous and the most recent determinations of the flow parameters of neutral gas in the local interstellar cloud (LIC) and an observation-based model of solar radiation pressure and ionization in the heliosphere, we simulated the flux of neutral interstellar D at IBEX for the actual measurement conditions. We assessed the number of interstellar D atom counts expected during the first three years of IBEX operation. We also simulated the observations expected during an epoch of high solar activity. In addition, we calculated the expected counts of D atoms from the thin terrestrial water layer covering the IBEX-Lo conversion surface, sputtered by neutral interstellar He atoms. Results: Most D counts registered by IBEX-Lo are expected to come from the water layer, exceeding the interstellar signal by 2 orders of magnitude. However, the sputtering should stop once the Earth leaves the portion of orbit traversed by interstellar He atoms. We identify seasons during the year when mostly the genuine interstellar D atoms are expected in the signal. During the first 3 years of IBEX operations about 2 detectable interstellar D atoms are expected. This number is comparable to the expected number of sputtered D atoms registered during the same time intervals. Conclusions: The most favorable conditions for the detection occur during low solar activity, in an interval including March and April each year. The detection chances could be improved by extending the instrument duty cycle, say, by making observations in the special deuterium mode of IBEX-Lo.
Resumo:
BACKGROUND: We investigated the psychometric properties of a short questionnaire for combined assessment of different perceived stress management skills in the general population and tested whether scores relate to physiological stress reactivity. METHODS: For psychometric evaluation, we determined the factor structure of the questionnaire and investigated its measurement invariance in the participant groups and over time in three different independent samples representing the general population (total N=332). Reliability was tested by estimating test-retest reliability, internal consistency, and item reliabilities. We examined convergent and criterion validity using selected criterion variables. For endocrine validation, 35 healthy non-smoking and medication-free men in a laboratory study and 35 male and female employees in a workplace study underwent an acute standardized psychosocial stress task. We assessed stress management skills and measured salivary cortisol before and several times up to 60 min (workplace study) and 120 min (laboratory study) after stress. Potential confounders were controlled. RESULTS: The factor structure of the questionnaire consists of five scales reflecting acceptably distinct stress management skills such as cognitive strategies, use of social support, relaxation strategies, anger regulation, and perception of bodily tension. This factor structure was stable across participant groups and over time. Internal consistencies, item reliabilities, and test-retest reliabilities met established statistical requirements. Convergent and criterion validity were also established. In both endocrine validation studies, higher stress management skills were independently associated with lower cortisol stress reactivity (p's<.029). CONCLUSIONS: Our findings suggest that the questionnaire has good psychometric properties and that it relates to subjective psychological and objective physiological stress indicators. Therefore, the instrument seems a suitable measure for differential assessment of stress management skills in the general population.
Resumo:
BACKGROUND: : Women at increased risk of breast cancer (BC) are not widely accepting of chemopreventive interventions, and ethnic minorities are underrepresented in related trials. Furthermore, there is no validated instrument to assess the health-seeking behavior of these women with respect to these interventions. METHODS: : By using constructs from the Health Belief Model, the authors developed and refined, based on pilot data, the Breast Cancer Risk Reduction Health Belief (BCRRHB) scale using a population of 265 women at increased risk of BC who were largely medically underserved, of low socioeconomic status (SES), and ethnic minorities. Construct validity was assessed using principal components analysis with oblique rotation to extract factors, and generate and interpret summary scales. Internal consistency was determined using Cronbach alpha coefficients. RESULTS: : Test-retest reliability for the pilot and final data was calculated to be r = 0.85. Principal components analysis yielded 16 components that explained 64% of the total variance, with communalities ranging from 0.50-0.75. Cronbach alpha coefficients for the extracted factors ranged from 0.45-0.77. CONCLUSIONS: : Evidence suggests that the BCRRHB yields reliable and valid data that allows for the identification of barriers and enhancing factors associated with use of breast cancer chemoprevention in the study population. These findings allow for tailoring treatment plans and intervention strategies to the individual. Future research is needed to validate the scale for use in other female populations. Cancer 2009. (c) 2009 American Cancer Society.
Resumo:
The previously described Nc5-specific PCR test for the diagnosis of Neospora caninum infections was used to develop a quantitative PCR assay which allows the determination of infection intensities within different experimental and diagnostic sample groups. The quantitative PCR was performed by using a dual fluorescent hybridization probe system and the LightCycler Instrument for online detection of amplified DNA. This assay was successfully applied for demonstrating the parasite proliferation kinetics in organotypic slice cultures of rat brain which were infected in vitro with N. caninum tachyzoites. This PCR-based method of parasite quantitation with organotypic brain tissue samples can be regarded as a novel ex vivo approach for exploring different aspects of cerebral N. caninum infection.
Resumo:
Introduction Since the quality of patient portrayal of standardized patients (SPs) during an Objective Structured Clinical Exam (OSCE) has a major impact on the reliability and validity of the exam, quality control should be initiated. Literature about quality control of SPs’ performance focuses on feedback [1, 2] or completion of checklists [3, 4]. Since we did not find a published instrument meeting our needs for the assessment of patient portrayal, we developed such an instrument after being inspired by others [5] and used it in our high-stakes exam. Project description SP trainers from five medical faculties collected and prioritized quality criteria for patient portrayal. Items were revised twice, based on experiences during OSCEs. The final instrument contains 14 criteria for acting (i.e. adequate verbal and non-verbal expression) and standardization (i.e. verbatim delivery of the first sentence). All partners used the instrument during a high-stakes OSCE. SPs and trainers were introduced to the instrument. The tool was used in training (more than 100 observations) and during the exam (more than 250 observations). Outcome High quality of SPs’ patient portrayal during the exam was documented. More than 90% of SP performances were rated to be completely correct or sufficient. An increase in quality of performance between training and exam was noted. For example, the rate of completely correct reaction in medical tests increased from 88% to 95%. Together with 4% of sufficient performances these 95% add up to 99% of the reactions in medical tests meeting the standards of the exam. SP educators using the instrument reported an augmentation of SPs’ performance induced by the use of the instrument. Disadvantages mentioned were the high concentration needed to observe all criteria and the cumbersome handling of the paper-based forms. Discussion We were able to document a very high quality of SP performance in our exam. The data also indicates that our training is effective. We believe that the high concentration needed using the instrument is well invested, considering the observed enhancement of performance. The development of an iPad-based application for the form is planned to address the cumbersome handling of the paper.
Resumo:
These guidelines are a working instrument for the assessment and documentation of existing and potential strategies for land and water conservation (prevention and mitigation strategies) in DESIRE study sites. DESIRE (Desertification Mitigation and Remediation of Land) is a European Integrated Project. The DESIRE WB 3 methodology was developed by CDE and is based on experiences from Learning for Sustainability (LforS) and WOCAT.
Resumo:
Aim: Occupational capacity evaluations have previously been subject to criticism for lacking in quality and consistency. To the authors' knowledge, there is no clear consensus on the best way to formally assess functioning within capacity evaluations. In this review we investigated different instruments that are used to assess functioning in occupational capacity evaluations. Methods: Systematic review of the literature. Results: Though several instruments that assess functional capacity were found in our search, a specific validated instrument assessing occupational capacity as part of a larger psychiatric evaluation was not found. The limitations of the existing instruments on assessing functional capacity are discussed. Conclusion: Medical experts relying on instruments to conduct functional capacity evaluations should be cognizant of their limitations. The findings call for the development and use of an instrument specifically designed to assess the functional and occupational capacity of psychiatric patients, which is also likely to improve the quality of these reports.