940 resultados para aerobic wastewater treatment


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Dissertation to obtain the degree of Master in Chemical and Biochemical Engineering

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In order to address and resolve the wastewater contamination problem of the Sines refinery with the main objective of optimizing the quality of this stream and reducing the costs charged to the refinery, a dynamic mass balance was developed nd implemented for ammonia and polar oil and grease (O&G) contamination in the wastewater circuit. The inadequate routing of sour gas from the sour water stripping unit and the kerosene caustic washing unit, were identified respectively as the major source of ammonia and polar substances present in the industrial wastewater effluent. For the O&G content, a predictive model was developed for the kerosene caustic washing unit, following the Projection to Latent Structures (PLS) approach. Comparison between analytical data for ammonia and polar O&G concentrations in refinery wastewater originating from the Dissolved Air Flotation (DAF) effluent and the model predictions of the dynamic mass balance calculations are in a very good agreement and highlights the dominant impact of the identified streams for the wastewater contamination levels. The ammonia contamination problem was solved by rerouting the sour gas through an existing clogged line with ammonia salts due to a non-insulated line section, while for the O&G a dynamic mass balance was implemented as an online tool, which allows for prevision of possible contamination situations and taking the required preventive actions, and can also serve as a basis for establishing relationships between the O&G contamination in the refinery wastewater with the properties of the refined crude oils and the process operating conditions. The PLS model developed could be of great asset in both optimizing the existing and designing new refinery wastewater treatment units or reuse schemes. In order to find a possible treatment solution for the spent caustic problem, an on-site pilot plant experiments for NaOH recovery from the refinery kerosene caustic washing unit effluent using an alkaline-resistant nanofiltration (NF) polymeric membrane were performed in order to evaluate its applicability for treating these highly alkaline and contaminated streams. For a constant operating pressure and temperature and adequate operating conditions, 99.9% of oil and grease rejection and 97.7% of chemical oxygen demand (COD) rejection were observed. No noticeable membrane fouling or flux decrease were registered until a volume concentration factor of 3. These results allow for NF permeate reuse instead of fresh caustic and for significant reduction of the wastewater contamination, which can result in savings of 1.5 M€ per year at the current prices for the largest Portuguese oil refinery. The capital investments needed for implementation of the required NF membrane system are less than 10% of those associated with the traditional wet air oxidation solution of the spent caustic problem. The operating costs are very similar, but can be less than half if reusing the NF concentrate in refinery pH control applications. The payback period was estimated to be 1.1 years. Overall, the pilot plant experimental results obtained and the process economic evaluation data indicate a very competitive solution through the proposed NF treatment process, which represents a highly promising alternative to conventional and existing spent caustic treatment units.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pharmaceuticals and personal care products (PPCPs) are widely used on a daily basis. After their usage they reach the wastewater treatment plants (WWTPs). These compounds have different physico-chemical characteristics, which makes them difficult to completely remove in the WWTPs, througth conventional treatments. Currently, there is no legislation regarding PPCPs thresholds in effluent discharge. But, even at vestigial concentrations, these compounds enclose environmental risks due to, e.g., endocrine disruption potential. There is a need of alternative techniques for their removal in WWTPs. The main goal of this work was to assess the use of electrodialytic (ED) process to remove PPCPs from the effluent to be discharged. A two-compartment ED cell was used testing (i) the effluent position in the cell (anode and cathode compartment); (ii) the use of anion (AEM) and cation exchange membrane (CEM); (iii) the treatment period (6, 12 and 24 hours); (iv) effluent recirculation and current steps; (v) the feasibility of sequential treatments. Phosphorus (P) removal from effluent and energetic costs associated to the process were also evaluated. Five PPCPs were studied – caffeine (CAF), bisphenol A (BPA), 17 β-estradiol (E2), ethinyl estradiol (EE2) and oxybenzone (MBPh). The ED process showed to be effective in the removal when effluent is in the anode compartment. Oxidation is suggested to be the main removal process, which was between 88 and 96%, for all the compounds, in 6 hours. Nevertheless, the presence of intermediates and/or by-products was also observed in some cases. Effluent recirculation should have a retention time in the ED cell big enough to promote removal whereas the current steps (effluent in anode compartment) slightly increased removal efficiencies (higher than 80% for all PPCPs). The sequential set of ED treatment (effluent in anode compartment) showed to be effective during both periods with a removal percentage between 80 and 95% and 73 to 88% in the case of AEM and CEM, respectively. Again, the main removal process is strongly suggested to be oxidation in the anode compartment. However, there was an increase of BOD5 and COD, which might be explained by effluent spiking, these parameters limiting the effluent discharge. From these treatments, the use of AEM, enhanced the P removal from effluent to minimize risk of eutrophication. Energetic costs of the best set-up (6 hours) are approximately 0,8€/m3 of wastewater, a value considered low, attending to the prices of other treatment processes.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

L’aigua i l’energia formen un binomi indissociable. En relació al cicle de l’aigua, des de fa varies dècades s’han desenvolupat diferents formes per recuperar part de l’energia relacionada amb l’aigua, per exemple a partir de centrals hidroelèctriques. No obstant, l’ús d’aquesta aigua també porta associat un gran consum energètic, relacionat sobretot amb el transport, la distribució, la depuració, etc... La depuració d’aigües residuals porta associada una elevada demanda energètica (Obis et al.,2009). En termes energètics, tot i que la despesa elèctrica d’una EDAR varia en funció de diferents paràmetres com la configuració i la capacitat de la planta, la càrrega a tractar, etc... es podria considerar que el rati mig seria d’ aproximadament 0.5 KWh•m-3.Els principals costos d’explotació estan relacionats tant amb la gestió de fangs (28%) com amb el consum elèctric (25%) (50% tractament biològic). Tot i que moltes investigacions relacionades amb el tractament d’aigua residual estan encaminades en disminuir els costos d’operació, des de fa poques dècades s’està investigant la viabilitat de que l’aigua residual fins i tot sigui una font d’energia, canviant la perspectiva, i començant a veure l’aigua residual no com a una problemàtica sinó com a un recurs. Concretament s’estima que l’aigua domèstica conté 9.3 vegades més energia que la necessària per el seu tractament mitjançant processos aerobis (Shizas et al., 2004). Un dels processos més desenvolupats relacionats amb el tractament d’aigües residuals i la producció energètica és la digestió anaeròbia. No obstant, aquesta tecnologia permet el tractament d’altes càrregues de matèria orgànica generant un efluent ric en nitrogen que s’haurà de tractar amb altres tecnologies. Per altre banda, recentment s’està investigant una nova tecnologia relacionada amb el tractament d’aigües residuals i la producció energètica: les piles biològiques (microbial fuel cells, MFC). Aquesta tecnologia permet obtenir directament energia elèctrica a partir de la degradació de substrats biodegradables (Rabaey et al., 2005). Les piles biològiques, més conegudes com a Microbial Fuel Cells (acrònim en anglès, MFC), són una emergent tecnologia que està centrant moltes mirades en el camp de l’ investigació, i que es basa en la producció d’energia elèctrica a partir de substrats biodegradables presents en l’aigua residual (Logan., 2008). Els fonaments de les piles biològiques és molt semblant al funcionament d’una pila Daniell, en la qual es separa en dos compartiments la reacció d’oxidació (compartiment anòdic) i la de reducció (compartiment catòdic) amb l’objectiu de generar un determinat corrent elèctric. En aquest estudi, bàsicament es mostra la posada en marxa d'una pila biològica per a l'eliminació de matèria orgànica i nitrogen de les aigües residuals.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Significant quantities of antibiotics are used in all parts of the globe to treat diseases with bacterial origins. After ingestion, antibiotics are excreted by the patient and transmitted in due course to the aquatic environment. This study examined temporal fluctuations (monthly time scale) in antibiotic sources (ambulatory sales and data from a hospital dispensary) for Lausanne, Switzerland. Source variability (i.e., antibiotic consumption, monthly data for 2006-2010) were examined in detail for nine antibiotics--azithromycin, ciprofloxacin, clarithromycin, clindamycin, metronidazole, norfloxacin, ofloxacin, sulfamethoxazole and trimethoprim, from which two main conclusions were reached. First, some substances--azithromycin, clarithromycin, ciprofloxacin--displayed high seasonality in their consumption, with the winter peak being up to three times higher than the summer minimum. This seasonality in consumption resulted in seasonality in Predicted Environmental Concentrations (PECs). In addition, the seasonality in PECs was also influenced by that in the base wastewater flow. Second, the contribution of hospitals to the total load of antibiotics reaching the Lausanne Wastewater Treatment Plant (WTP) fluctuated markedly on a monthly time scale, but with no seasonal pattern detected. That is, there was no connection between fluctuations in ambulatory and hospital consumption for the substances investigated.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The objective of this study was to evaluate the prevalence and dissemination of human astroviruses (HAstV) in the environment by analyzing urban sewage samples from a wastewater treatment plant in the city of Rio de Janeiro, Brazil. A one-year study was performed with a total of 48 raw and treated sewage composite samples, which were collected biweekly from an activated sludge plant. Virus particles were concentrated by the adsorption-elution method using negatively charged membranes associated to a Centriprep Concentrator® 50 (Nihon Millipore). HAstV were detected in 16.7% of the samples in raw and treated sewage by using both qualitative and quantitative reverse transcriptase-polymerase chain reactions (RT-PCR and qPCR, respectively). Positive untreated sewage sample exhibited mean values of 1.1 x 10(4) gEq/mL. The qPCR sensitivity was 18 gEq/reaction. Through utilization of qPCR, a HAstV recovery efficiency of 4.2% and 4.3% was demonstrated for raw and treated sewage samples, respectively. The presence of HAstV in both the raw and treated sewage samples demonstrated the dissemination of these viruses in the environment as well as viral permanence after sewage treatment. There was a reduction in the total and faecal coliform levels, indicating efficiency of the wastewater treatment plant.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A total of 49 wastewater samples from 23 different wastewater treatment plants (WWTPs) were analyzed using real-time quantitative polymerase chain reaction for the presence and quantity of thermotolerant campylobacters. Thermotolerant campylobacters were detected in 87.5% (21/24) and 64% (16/25) of untreated and treated wastewater samples, respectively. Their concentration was sufficiently high to be quantified in 20.4% (10/49) of the samples. In these samples, the concentration ranged from 68 000 to 2292 000 cells/L in untreated wastewater and from 10 800 to 28 000 cells/L in treated water. We conclude that thermotolerant campylobacters present a health hazard for workers at WWTPs in Switzerland. [Authors]

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Yhä suurempi osa suurkeittiöistä ja ravintoloista käyttää ruuan valmistuksessa valmiiksi prosessoituja kasviksia, jotka hankitaan pääasiassa lähellä sijaitsevista tilakuorimoista. Kuorimoilla syntyy suuria määriä jätettä, enimmäkseen kuorijätteitä, multaa ja jätevettä. Tässä työssä tarkastellaan perunankuorimoiden kuorintamenetelmiä ja kuorintaprosessia, prosessissa syntyviä jätteitä ja niiden käsittelyä sekä ympäristöasioiden hallintamenetel-miä kuorimoilla Suomessa ja muissa EU-maissa. Työn tavoitteena oli selvittää, minkälainen on lainsäädäntö ja minkälaiset ovat kuorimotoimintaa koskevat lupakäytännöt Ruotsissa, Saksassa, Belgiassa ja Iso-Britanniassa. Lisäksi tavoitteena oli selvittää, onko näissä maissa määritelty, millainen on perunankuorimoille soveltuva paras käyttökelpoinen tekniikka (BAT) erityisesti jätteiden käsittelyssä. Euroopan yhteisön neuvoston direktiivi (96/61/EY) ympäristön pilaantumisen ehkäisemisen ja vähentämisen yhtenäistämiseksi edellyttää perunankuorimoilta toimintaansa ympäristöluvan. Laitosten koko, joilta ympäristölupa vaaditaan, vaihtelee suuresti eri maissa. Myös kuorimoiden jäteveden puhdistusvaatimukset vaihtelevat maittain. Belgi-assa ja Saksassa perunankuorimoilla syntyville jätevesille on asetettu päästöraja-arvot laissa. Kansallinen BAT-ohjeistus vihanneksia ja hedelmiä jatkojalostavalle teollisuudelleon tehty Belgiassa ja Iso-Britanniassa. Sen sijaan Saksassa ja Ruotsissa kansallista ohjeistusta ei ole tehty. Kansallisten BAT-ohjeistusten pohjalta Euroopan yhteisöjen komissio on julkaissut tammikuussa 2006 elintarviketeollisuudelle BAT-vertailuasiakirjan eli BREFin (BAT Referense Document), joissa kuvataan yleisellä tasolla BAT-tekniikoiksi sovitut tekniikat mm. perunan prosessoinnissa. Tässä työssä tuli ilmi, että kokoerot Suomen ja tässä työssä tarkasteltavien maiden kuo-rimoiden välillä ovat suuret. Voidaankin todeta, että tässä työssä tarkastelluissa BAT - ohjeistuksissa ja Euroopan komission BREF-dokumentissa esitetyt BAT-tekniikat etenkin jätevedenpuhdistuksessa eivät suoraan ole sovellettavissa Suomen olosuhteisiin kuorimoidemme pienestä koosta johtuen. Kiinteiden kuorintajätteiden käsittelyssä BAT-tekniikoiksi ulkomailla on määritelty lä-hinnä rehukäyttö, kompostointi ja peltoon levitys. Perunankuorimoiden jäteveden puhdistuksessa BAT-tekniikaksi Belgiassa on määritelty primääripuhdistus ja sekundääripuhdistus aerobisella menetelmällä. Iso-Britanniassapuolestaan BAT-tekniikkaa on primää-ripuhdistus, sekundääripuhdistus aerobisesti tai anaerobisesti ja tertiääripuhdistus, mikäli se on taloudellisesti mahdollista toteuttaa. Kuorijätteiden kompostointi on tällä hetkelläSuomessa melko harvinaista, sillä jätteiden suuri vesipitoisuus ja kylmä ilmastomme vaikeuttavat kompostointia. Kompostointimah-dollisuuksia ja kompostointiprosessin optimointia kuorintajätteille sopivaksi tulisikin tutkia tulevaisuudessa yhtenä jätteiden käsittelyvaihtoehtona. Kuorimoiden jätevesien puhdistuksessa tulevat Suomessa kysymykseen lähinnä yksinkertaiset kiinteistökohtaiset pienpuhdistamot, kuten panospuhdistamot. Pienpuhdistamolaitteistoihin liittyvää tutki-mus-ja kehitystyötä on viime vuosina tehty paljon ja sitä olisi tärkeää jatkaa edelleen, jotta löydettäisiin entistä kustannustehokkaampia ratkaisuja.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pumppauksessa arvioidaan olevan niin teknisesti kuin taloudellisestikin huomattavia mahdollisuuksia säästää energiaa. Maailmanlaajuisesti pumppaus kuluttaa lähes 22 % sähkö-moottorien energiantarpeesta. Tietyillä teollisuudenaloilla jopa yli 50 % moottorien käyttämästä sähköenergiasta voi kulua pumppaukseen. Jäteveden pumppauksessa pumppujen toiminta perustuu tyypillisesti on-off käyntiin, jolloin pumpun ollessa päällä se käy täydellä teholla. Monissa tapauksissa pumput ovat myös ylimitoitettuja. Yhdessä nämä seikat johtavat kasvaneeseen energian kulutukseen. Työn teoriaosassa esitellään perusteet jätevesihuollosta ja jäteveden käsittelystä sekä pumppaussysteemin pääkomponentit: pumppu, putkisto, moottori ja taajuusmuuttaja. Työn empiirisessä osassa esitellään työn aikana kehitetty laskuri, jonka avulla voidaan arvioida energiansäästöpotentiaalia jäteveden pumppaussysteemeissä. Laskurilla on mandollista laskea energiansäästöpotentiaali käytettäessä pumpun tuoton ohjaustapana pyörimisnopeuden säätöä taajuusmuuttajalla on-off säädön sijasta. Laskuri ilmoittaa optimaalisimmanpumpun pyörimisnopeuden sekä ominaisenergiankulutuksen. Perustuen laskuriin, kolme kunnallista jätevedenpumppaamoa tutkittiin. Myös laboratorio-testitsuoritettiin laskurin simuloimiseksi sekä energiansäästöpotentiaalin arvioimiseksi. Tutkimukset osoittavat, että jätevedenpumppauksessa on huomattavia mandollisuuksia säästää energiaa pumpun pyörimisnopeutta pienentämällä. Geodeettisen nostokorkeuden ollessa pieni, voidaan energiaa säästää jopa 50 % ja pitkällä aikavälillä säästö voi olla merkittävä. Tulokset vahvistavat myös tarpeen jätevedenpumppaussysteemien toiminnan optimoimiseksi.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Työ on tehty osana ympäristöklusterin tutkimusohjelmaa "Materiaalivirrat ja energiankäyttö metsäteollisuusintegraatissa ja niihin liittyvät toimintastrategiat ympäristövaikutuslähtöisesti". Juha Räsänen on tehnyt metsäteollisuuden sivuainevirroista projektissa perusselvityksen, joka on tämän työn pohjana. Työn tavoitteena on ollut selvittää neljän itäsuomalaisen metsäteollisuusintegraatin tapauksissa vaihtoehtoisten lietteenkäsittelymenetelmien tekninen ja taloudellinen soveltuvuus nykyiseen käsittelyyn verrattuna. Tutkimuksessa hyödynnettiin aikaisempia tutkimustuloksia ja eri laitevalmistajien ja metsäteollisuusintegraattien kokemuksia. Työssä esitettäviä arvioita voidaan hyödyntää myös sektoritasolla. Metsäteollisuuden jätevedenpuhdistamon lietteistä käsiteltävyyden kannalta vaativin on bioliete, jonka osuuden kasvaessa perinteinen mekaaninen puristaminen ja poltto vaikeutuvat useilla tehtailla merkittävästikin nykyään ja lähivuosina. Polton ongelmat ja niistä aiheutuva ajoittainen aumakompostointitarve voivat puoltaa joko sekalietteen termistä tai biotermistä kuivausta ennen polttamista. Toinen tapa ratkaista lieteongelma on käsitellä bio- ja primäärilietteet erikseen. Biolietteen lipeälinjakäsittelyssä liete lingotaan, käsitellään mustalipeällä, haihdutetaan ja poltetaan soodakattilassa. Bioliete voidaan myös mädättää ja käsitellä sen jälkeen perinteisessä mekaanisessa puristuksessa. Kaikki käsitellyt menetelmät ovat teknisesti toteutettavissa, kunhan tietyt prosessireunaehdot täyttyvät. Vaihtoehtoiset käsittelymenetelmät vähentävät lietteen jäteluonnetta, mutta vastaavasti kustannukset lisääntyvät usein merkittävästi. Menetelmien käytöstä aiheutuvat integraatin puhdistamolietteen käsittelyn kokonaiskustannukset laskettiin työn osana olevalla taulukkolaskentasovelluksella laitetoimittajien budjettitarjouksia hyödyntäen. Biolietteen poltto soodakattilassa tarjoaa kustannusten kannalta houkuttelevimman ratkaisun. Työhön sisältyvää laskentamenettelyä voidaan soveltaa periaatteessa minkä tahansa metsäteollisuusintegraatin tapaukseen.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Wastewater-based epidemiology consists in acquiring relevant information about the lifestyle and health status of the population through the analysis of wastewater samples collected at the influent of a wastewater treatment plant. Whilst being a very young discipline, it has experienced an astonishing development since its firs application in 2005. The possibility to gather community-wide information about drug use has been among the major field of application. The wide resonance of the first results sparked the interest of scientists from various disciplines. Since then, research has broadened in innumerable directions. Although being praised as a revolutionary approach, there was a need to critically assess its added value, with regard to the existing indicators used to monitor illicit drug use. The main, and explicit, objective of this research was to evaluate the added value of wastewater-based epidemiology with regards to two particular, although interconnected, dimensions of illicit drug use. The first is related to trying to understand the added value of the discipline from an epidemiological, or societal, perspective. In other terms, to evaluate if and how it completes our current vision about the extent of illicit drug use at the population level, and if it can guide the planning of future prevention measures and drug policies. The second dimension is the criminal one, with a particular focus on the networks which develop around the large demand in illicit drugs. The goal here was to assess if wastewater-based epidemiology, combined to indicators stemming from the epidemiological dimension, could provide additional clues about the structure of drug distribution networks and the size of their market. This research had also an implicit objective, which focused on initiating the path of wastewater- based epidemiology at the Ecole des Sciences Criminelles of the University of Lausanne. This consisted in gathering the necessary knowledge about the collection, preparation, and analysis of wastewater samples and, most importantly, to understand how to interpret the acquired data and produce useful information. In the first phase of this research, it was possible to determine that ammonium loads, measured directly in the wastewater stream, could be used to monitor the dynamics of the population served by the wastewater treatment plant. Furthermore, it was shown that on the long term, the population did not have a substantial impact on consumption patterns measured through wastewater analysis. Focussing on methadone, for which precise prescription data was available, it was possible to show that reliable consumption estimates could be obtained via wastewater analysis. This allowed to validate the selected sampling strategy, which was then used to monitor the consumption of heroin, through the measurement of morphine. The latter, in combination to prescription and sales data, provided estimates of heroin consumption in line with other indicators. These results, combined to epidemiological data, highlighted the good correspondence between measurements and expectations and, furthermore, suggested that the dark figure of heroin users evading harm-reduction programs, which would thus not be measured by conventional indicators, is likely limited. In the third part, which consisted in a collaborative study aiming at extensively investigating geographical differences in drug use, wastewater analysis was shown to be a useful complement to existing indicators. In particular for stigmatised drugs, such as cocaine and heroin, it allowed to decipher the complex picture derived from surveys and crime statistics. Globally, it provided relevant information to better understand the drug market, both from an epidemiological and repressive perspective. The fourth part focused on cannabis and on the potential of combining wastewater and survey data to overcome some of their respective limitations. Using a hierarchical inference model, it was possible to refine current estimates of cannabis prevalence in the metropolitan area of Lausanne. Wastewater results suggested that the actual prevalence is substantially higher compared to existing figures, thus supporting the common belief that surveys tend to underestimate cannabis use. Whilst being affected by several biases, the information collected through surveys allowed to overcome some of the limitations linked to the analysis of cannabis markers in wastewater (i.e., stability and limited excretion data). These findings highlighted the importance and utility of combining wastewater-based epidemiology to existing indicators about drug use. Similarly, the fifth part of the research was centred on assessing the potential uses of wastewater-based epidemiology from a law enforcement perspective. Through three concrete examples, it was shown that results from wastewater analysis can be used to produce highly relevant intelligence, allowing drug enforcement to assess the structure and operations of drug distribution networks and, ultimately, guide their decisions at the tactical and/or operational level. Finally, the potential to implement wastewater-based epidemiology to monitor the use of harmful, prohibited and counterfeit pharmaceuticals was illustrated through the analysis of sibutramine, and its urinary metabolite, in wastewater samples. The results of this research have highlighted that wastewater-based epidemiology is a useful and powerful approach with numerous scopes. Faced with the complexity of measuring a hidden phenomenon like illicit drug use, it is a major addition to the panoply of existing indicators. -- L'épidémiologie basée sur l'analyse des eaux usées (ou, selon sa définition anglaise, « wastewater-based epidemiology ») consiste en l'acquisition d'informations portant sur le mode de vie et l'état de santé d'une population via l'analyse d'échantillons d'eaux usées récoltés à l'entrée des stations d'épuration. Bien qu'il s'agisse d'une discipline récente, elle a vécu des développements importants depuis sa première mise en oeuvre en 2005, notamment dans le domaine de l'analyse des résidus de stupéfiants. Suite aux retombées médiatiques des premiers résultats de ces analyses de métabolites dans les eaux usées, de nombreux scientifiques provenant de différentes disciplines ont rejoint les rangs de cette nouvelle discipline en développant plusieurs axes de recherche distincts. Bien que reconnu pour son coté objectif et révolutionnaire, il était nécessaire d'évaluer sa valeur ajoutée en regard des indicateurs couramment utilisés pour mesurer la consommation de stupéfiants. En se focalisant sur deux dimensions spécifiques de la consommation de stupéfiants, l'objectif principal de cette recherche était focalisé sur l'évaluation de la valeur ajoutée de l'épidémiologie basée sur l'analyse des eaux usées. La première dimension abordée était celle épidémiologique ou sociétale. En d'autres termes, il s'agissait de comprendre si et comment l'analyse des eaux usées permettait de compléter la vision actuelle sur la problématique, ainsi que déterminer son utilité dans la planification des mesures préventives et des politiques en matière de stupéfiants actuelles et futures. La seconde dimension abordée était celle criminelle, en particulier, l'étude des réseaux qui se développent autour du trafic de produits stupéfiants. L'objectif était de déterminer si cette nouvelle approche combinée aux indicateurs conventionnels, fournissait de nouveaux indices quant à la structure et l'organisation des réseaux de distribution ainsi que sur les dimensions du marché. Cette recherche avait aussi un objectif implicite, développer et d'évaluer la mise en place de l'épidémiologie basée sur l'analyse des eaux usées. En particulier, il s'agissait d'acquérir les connaissances nécessaires quant à la manière de collecter, traiter et analyser des échantillons d'eaux usées, mais surtout, de comprendre comment interpréter les données afin d'en extraire les informations les plus pertinentes. Dans la première phase de cette recherche, il y pu être mis en évidence que les charges en ammonium, mesurées directement dans les eaux usées permettait de suivre la dynamique des mouvements de la population contributrice aux eaux usées de la station d'épuration de la zone étudiée. De plus, il a pu être démontré que, sur le long terme, les mouvements de la population n'avaient pas d'influence substantielle sur le pattern de consommation mesuré dans les eaux usées. En se focalisant sur la méthadone, une substance pour laquelle des données précises sur le nombre de prescriptions étaient disponibles, il a pu être démontré que des estimations exactes sur la consommation pouvaient être tirées de l'analyse des eaux usées. Ceci a permis de valider la stratégie d'échantillonnage adoptée, qui, par le bais de la morphine, a ensuite été utilisée pour suivre la consommation d'héroïne. Combinée aux données de vente et de prescription, l'analyse de la morphine a permis d'obtenir des estimations sur la consommation d'héroïne en accord avec des indicateurs conventionnels. Ces résultats, combinés aux données épidémiologiques ont permis de montrer une bonne adéquation entre les projections des deux approches et ainsi démontrer que le chiffre noir des consommateurs qui échappent aux mesures de réduction de risque, et qui ne seraient donc pas mesurés par ces indicateurs, est vraisemblablement limité. La troisième partie du travail a été réalisée dans le cadre d'une étude collaborative qui avait pour but d'investiguer la valeur ajoutée de l'analyse des eaux usées à mettre en évidence des différences géographiques dans la consommation de stupéfiants. En particulier pour des substances stigmatisées, telles la cocaïne et l'héroïne, l'approche a permis d'objectiver et de préciser la vision obtenue avec les indicateurs traditionnels du type sondages ou les statistiques policières. Globalement, l'analyse des eaux usées s'est montrée être un outil très utile pour mieux comprendre le marché des stupéfiants, à la fois sous l'angle épidémiologique et répressif. La quatrième partie du travail était focalisée sur la problématique du cannabis ainsi que sur le potentiel de combiner l'analyse des eaux usées aux données de sondage afin de surmonter, en partie, leurs limitations. En utilisant un modèle d'inférence hiérarchique, il a été possible d'affiner les actuelles estimations sur la prévalence de l'utilisation de cannabis dans la zone métropolitaine de la ville de Lausanne. Les résultats ont démontré que celle-ci est plus haute que ce que l'on s'attendait, confirmant ainsi l'hypothèse que les sondages ont tendance à sous-estimer la consommation de cannabis. Bien que biaisés, les données récoltées par les sondages ont permis de surmonter certaines des limitations liées à l'analyse des marqueurs du cannabis dans les eaux usées (i.e., stabilité et manque de données sur l'excrétion). Ces résultats mettent en évidence l'importance et l'utilité de combiner les résultats de l'analyse des eaux usées aux indicateurs existants. De la même façon, la cinquième partie du travail était centrée sur l'apport de l'analyse des eaux usées du point de vue de la police. Au travers de trois exemples, l'utilisation de l'indicateur pour produire du renseignement concernant la structure et les activités des réseaux de distribution de stupéfiants, ainsi que pour guider les choix stratégiques et opérationnels de la police, a été mise en évidence. Dans la dernière partie, la possibilité d'utiliser cette approche pour suivre la consommation de produits pharmaceutiques dangereux, interdits ou contrefaits, a été démontrée par l'analyse dans les eaux usées de la sibutramine et ses métabolites. Les résultats de cette recherche ont mis en évidence que l'épidémiologie par l'analyse des eaux usées est une approche pertinente et puissante, ayant de nombreux domaines d'application. Face à la complexité de mesurer un phénomène caché comme la consommation de stupéfiants, la valeur ajoutée de cette approche a ainsi pu être démontrée.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Nitrous oxide emissions from an activated sludge plant which serves a research institute in Rio de Janeiro city were estimated from six unit processes (grit tank, sand trap, aeration tank, secondary settling tank, sludge recirculation line and aerobic digester sludge tank) and also from the plant effluent. Total estimated annual flux was 3.2 x 10(4) g N2O yr-1 of which about 90% was from the aeration tank. Emission factors estimated from population served, wastewater flow and nitrogen load (conversion ratio) were 13 g N2O person-1 yr-1, 9.0 x 10-5 g N2O Lwastewater-1 and 0.14%.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The nutrient load to the Gulf of Finland has started to increase as a result of the strong economic recovery in agriculture and livestock farming in the Leningrad region. Also sludge produced from municipal wastewater treatment plant of the Leningrad region causes the great impact on the environment, but still the main options for its treatment is disposal on the sludge beds or Landfills. The aim of this study was to evaluate the implementation of possible joint treatment methods of manure form livestock and poultry enterprises and sewage sludge produced from municipal wastewater treatment plants in the Leningrad region. The study is based on published data. The most attention was put on the anaerobic digestion and incineration methods. The manure and sewage sludge generation for the whole Leningrad region and energy potential produced from their treatment were estimated. The calculations showed that total amount of sewage sludge generation is 1 348 000 t/a calculated on wet matter and manure generation is 3 445 000 t/a calculated on wet matter. The potential heat release from anaerobic digestion process and incineration process is 4 880 000 GJ/a and 5 950 000 GJ/a, respectively. Furthermore, the work gives the overview of the general Russian and Finnish legislation concerning manure and sewage sludge treatment. In the Gatchina district it was chosen the WWTP and livestock and poultry enterprises for evaluation of the centralized treatment plant implementation based on anaerobic digestion and incineration methods. The electricity and heat power of plant based on biogas combustion process is 4.3 MW and 7.8 MW, respectively. The electricity and heat power of plant based on manure and sewage sludge incineration process is 3.0 MW and 6.1 MW, respectively.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Laboratories consume great amounts of hazardous chemicals substances and consequently generate wastewater containing them, for example formaldehyde. This substance is widely utilized to preserve biological samples generating many liters of this residue every year. The present work proposes the use of the photo-Fenton process to treat formaldehyde wastewater using sunlight irradiation. Some aspects were investigated such as the iron source, sample and hydrogen peroxide concentration and also the use of stirred systems. The use of ferrioxalate (0.5 mmol L-1) improved the efficiency of the process in relation to the use of iron nitrate, while at least 1.0 mol L-1 H2O2 is necessary to treat the sample of the 500 mg C L-1. Under these conditions, every formaldehyde detectable was degradeted and 89% of the dissolved organic carbon was removed in two hours of exposure to sunlight. These results are satisfaction considerate for São Paulo State Environmental Agency.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Chemical coagulation is commonly used in raw water and wastewater treatment plants for the destabilisation of pollutants so that they can be removed in the subsequent separation processes. The most commonly used coagulation chemicals are aluminium and iron metal salts. Electrocoagulation technology has also been proposed for the treatment of raw waters and wastewaters. With this technology, metal cations are produced on the electrodes via electrolysis and these cations form various hydroxides in the water depending on the water pH. In addition to this main reaction, several side reactions, such as hydrogen bubble formation and the reduction of metals on cathodes, also take place in the cell. In this research, the applications of electrocoagulation were investigated in raw water treatment and wastewater applications. The surface water used in this research contained high concentrations of natural organic matter (NOM). The effect of the main parameters – current density, initial pH, electric charge per volume, temperature and electrolysis cell construction – on NOM removal were investigated. In the wastewater treatment studies, the removal of malodorous sulphides and toxic compounds from the wastewaters and debarking effluents were studied. Also, the main parameters of the treatment, such as initial pH and current density, were investigated. Aluminium electrodes were selected for the raw water treatment, whereas wastewaters and debarking effluent were treated with iron electrodes. According to results of this study, aluminium is more suitable electrode material for electrocoagulation applications because it produces Al(III) species. Metal ions and hydroxides produced by iron electrodes are less effective in the destabilisation of pollutants because iron electrodes produce more soluble and less charged Fe(II) species. However, Fe(II) can be effective in some special applications, such as sulphide removal. The resulting metal concentration is the main parameter affecting destabilisation of pollutants. Current density, treatment time, temperature and electrolysis cell construction affect the dissolution of electrodes and hence also the removal of pollutants. However, it seems that these parameters have minimal significance in the destabilization of the pollutants besides this effect (in the studied range of parameters). Initial pH and final pH have an effect on the dissolution of electrodes, but they also define what aluminium or iron species are formed in the solution and have an effect on the ζ-potential of all charged species in the solution. According to the results of this study, destabilisation mechanisms of pollutants by electrocoagulation and chemical coagulation are similar. Optimum DOC removal and low residual aluminium can be obtained simultaneously with electrocoagulation, which may be a significant benefit of electrocoagulation in surface water treatment compared to chemical coagulation. Surface water treatment with electrocoagulation can produce high quality water, which could be used as potable water or fresh water for industrial applications. In wastewater treatment applications, electrocoagulation can be used to precipitate malodorous sulphides to prevent their release into air. Technology seems to be able to remove some toxic pollutants from wastewater and could be used as pretreatment prior to treatment at a biological wastewater treatment plant. However, a thorough economic and ecological comparison of chemical coagulation and electrocoagulation is recommended, because these methods seem to be similar in pollutant destabilisation mechanisms, metal consumption and removal efficiency in most applications.