966 resultados para Zakonopravilo svetoga Save (64 titles)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: This retrospective study was conducted to determine whether a low-volume contrast medium protocol provides sufficient enhancement for 64-detector computed tomography angiography (CTA) in patients with aortoiliac aneurysms. METHODS: Evaluated were 45 consecutive patients (6 women; mean age, 72 +/- 6 years) who were referred for aortoiliac computed tomography angiography between October 2005 and January 2007. Group A (22 patients; creatinine clearance, 64.2 +/- 8.1 mL/min) received 50 mL of the contrast agent. Group B (23 patients; creatinine clearance, 89.4 +/- 7.3 mL/min) received 100 mL of the contrast agent. The injection rate was 3.5 mL/s, followed by 30 mL of saline at 3.5 mL/s. Studies were performed on the same 64-detector computed tomography scanner using a real-time bolus-tracking technique. Quantitative analysis was performed by determination of mean vascular attenuation at 10 regions of interest from the suprarenal aorta to the common femoral artery by one reader blinded to type and amount of contrast agent and compared using the Student t test. Image quality according to a 4-point scale was assessed in consensus by two readers blinded to type and amount of contrast medium and compared using the Mann-Whitney test. Multivariable adjustments were performed using ordinal regression analysis. RESULTS: Mean total attenuation did not differ significantly between both groups (196.5 +/- 33.0 Hounsfield unit [HU] in group A and 203.1 +/- 44.2 HU in group B; P = .57 by univariate and P > .05 by multivariable analysis). Accordingly, attenuation at each region of interest was not significantly different (P > .35). Image quality was excellent or good in all patients. No significant differences in visual assessment were found comparing both contrast medium protocols (P > .05 by univariate and by multivariable analysis). CONCLUSIONS: Aortoiliac aneurysm imaging can be performed with substantially reduced amounts of contrast medium using 64-detector computed tomography angiography technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To prospectively determine the accuracy of 64-section computed tomographic (CT) angiography for the depiction of coronary artery disease (CAD) that induces perfusion defects at myocardial perfusion imaging with single photon emission computed tomography (SPECT), by using myocardial perfusion imaging as the reference standard. MATERIALS AND METHODS: All patients gave written informed consent after the study details, including radiation exposure, were explained. The study protocol was approved by the local institutional review board. In patients referred for elective conventional coronary angiography, an additional 64-section CT angiography study and a myocardial perfusion imaging study (1-day adenosine stress-rest protocol) with technetium 99m-tetrofosmin SPECT were performed before conventional angiography. Coronary artery diameter narrowing of 50% or greater at CT angiography was defined as stenosis and was compared with the myocardial perfusion imaging findings. Quantitative coronary angiography served as a reference standard for CT angiography. RESULTS: A total of 1093 coronary segments in 310 coronary arteries in 78 patients (mean age, 65 years +/- 9 [standard deviation]; 35 women) were analyzed. CT angiography revealed stenoses in 137 segments (13%) corresponding to 91 arteries (29%) in 46 patients (59%). SPECT revealed 14 reversible, 13 fixed, and six partially reversible defects in 31 patients (40%). Sensitivity, specificity, and negative and positive predictive values, respectively, of CT angiography in the detection of reversible myocardial perfusion imaging defects were 95%, 53%, 94%, and 58% on a per-patient basis and 95%, 75%, 96%, and 72% on a per-artery basis. Agreement between CT and conventional angiography was very good (96% and kappa = 0.92 for patient-based analysis, 93% and kappa = 0.84 for vessel-based analysis). CONCLUSION: Sixty-four-section CT angiography can help rule out hemodynamically relevant CAD in patients with intermediate to high pretest likelihood, although an abnormal CT angiography study is a poor predictor of ischemia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Das Entschädigungsabkommen zwischen der Bundesrepublik Deutschland und Großbritannien von 1964 war eins von insgesamt elf Globalabkommen, die um 1960 zwischen der Bundesrepublik und verschiedenen westeuropäischen Staaten zur Wiedergutmachung nationalsozialistischen Unrechts geschlossen wurden. In der britischen Erinnerungskultur spielten die NS-Verbrechen damals nach wie vor eine große Rolle. Breite Teile der Öffentlichkeit – mobilisiert durch Presse und Wohlfahrtsorganisationen – verfolgten die Verhandlungen und kritisierten die Haltung vor allem der deutschen, aber auch der britischen Regierung. Strittig war besonders die Frage, welche Opferkategorien in das Abkommen miteinbezogen werden sollten. Dies betraf vor allem staatenlose Verfolgte, die erst nach Kriegsende die britische Staatsbürgerschaft erhalten hatten. Während Großbritannien die Berücksichtigung dieser Gruppe forderte, verwies die Bundesregierung auf den UN-Fonds für staatenlose Opfer. 1964 zahlte die Bundesrepublik schließlich eine Pauschalsumme an Großbritannien, über deren Verteilung die britische Regierung selbst bestimmen konnte.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The range of novel psychoactive substances (NPS) including phenethylamines, cathinones, piperazines, tryptamines, etc. is continuously growing. Therefore, fast and reliable screening methods for these compounds are essential and needed. The use of dried blood spots (DBS) for a fast straightforward approach helps to simplify and shorten sample preparation significantly. DBS were produced from 10 µl of whole blood and extracted offline with 500 µl methanol followed by evaporation and reconstitution in mobile phase. Reversed-phase chromatographic separation and mass spectrometric detection (RP-LC-MS/MS) was achieved within a run time of 10 min. The screening method was validated by evaluating the following parameters: limit of detection (LOD), matrix effect, selectivity and specificity, extraction efficiency, and short-term and long-term stability. Furthermore, the method was applied to authentic samples and results were compared with those obtained with a validated whole blood method used for Routine analysis of NPS. LOD was between 1 and 10 ng/ml. No interference from Matrix compounds was observed. The method was proven to be specific and selective for the analytes, although with limitations for 3-FMC/flephedrone and MDDMA/MDEA. Mean extraction efficiency was 84.6 %. All substances were stable in DBS for at least a week when cooled. Cooling was essential for the stability of cathinones. Prepared samples were stable for at least 3 days. Comparison to the validated whole blood method yielded similar results. DBS were shown to be useful in developing a rapid screening method for NPS with simplified sample preparation. Copyright © 2013 John Wiley & Sons, Ltd

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In many languages, feminization has been used as a strategy to make language more gender-fair, because masculine terms, even in a generic function, exhibit a male bias. Up to date, little is known about possible side effects of this language use, for example, in personnel selection. In three studies, conducted in Polish, we analyzed how a female applicant was evaluated in a recruitment process, depending on whether she was introduced with a feminine or masculine job title. To avoid influences from existing occupations and terms, we used fictitious job titles in Studies 1 and 2: diarolożka (feminine) and diarolog (masculine). In Study 3, we referred to existing occupations that varied in gender stereotypicality. In all studies, female applicants with a feminine job title were evaluated less favorably than both a male applicant (Study 1) and a female applicant with a masculine job title (Studies 1, 2, and 3). This effect was independent of the gender stereotypicality of the occupation (Study 3). Participants' political attitudes, however, moderated the effect: Conservatives devaluated female applicants with a feminine title more than liberals (Studies 2 and 3).

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The assessment of coronary stents with present-generation 64-detector row computed tomography (HDCT) scanners is limited by image noise and blooming artefacts. We evaluated the performance of adaptive statistical iterative reconstruction (ASIR) for noise reduction in coronary stent imaging with HDCT. METHODS AND RESULTS: In 50 stents of 28 patients (mean age 64 ± 10 years) undergoing coronary CT angiography (CCTA) on an HDCT scanner the mean in-stent luminal diameter, stent length, image quality, in-stent contrast attenuation, and image noise were assessed. Studies were reconstructed using filtered back projection (FBP) and ASIR-FBP composites. ASIR resulted in reduced image noise vs. FBP (P < 0.0001). Two readers graded the CCTA stent image quality on a 4-point Likert scale and determined the proportion of interpretable stent segments. The best image quality for all clinical images was obtained with 40 and 60% ASIR with significantly larger luminal area visualization compared with FBP (+42.1 ± 5.4% with 100% ASIR vs. FBP alone; P < 0.0001) while the stent length was decreased (-4.7 ± 0.9%,