945 resultados para Welding Procedure Specification


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract OBJECTIVE To search for the scientific evidence available on nursing professional actions during the anesthetic procedure. METHOD An integrative review of articles in Portuguese, English and Spanish, indexed in MEDLINE/PubMed, CINAHL, LILACS, National Cochrane, SciELO databases and the VHL portal. RESULTS Seven studies were analyzed, showing nurse anesthetists' work in countries such as the United States and parts of Europe, with the formulation of a plan for anesthesia and patient care regarding the verification of materials and intraoperative controls. The barriers to their performance involved working in conjunction with or supervised by anesthesiologists, the lack of government guidelines and policies for the legal exercise of the profession, and the conflict between nursing and the health system for maintenance of the performance in places with legislation and defined protocols for the specialty. Conclusion Despite the methodological weaknesses found, the studies indicated a wide diversity of nursing work. Furthermore, in countries absent of the specialty, like Brazil, the need to develop guidelines for care during the anesthetic procedure was observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Asphalt pavement recycling has grown dramatically over the last few years as a viable technology to rehabilitate existing asphalt pavements. Iowa's current Cold In-place Recycling (CIR) practice utilizes a generic recipe specification to define the characteristics of the CIR mixture. As CIR continues to evolve, the desire to place CIR mixture with specific engineering properties requires the use of a mix design process. A new mix design procedure was developed for Cold In-place Recycling using foamed asphalt (CIR-foam) in consideration of its predicted field performance. The new laboratory mix design process was validated against various Reclaimed Asphalt Pavement (RAP) materials to determine its consistency over a wide range of RAP materials available throughout Iowa. The performance tests, which include dynamic modulus test, dynamic creep test and raveling test, were conducted to evaluate the consistency of a new CIR-foam mix design process to ensure reliable mixture performance over a wide range of traffic and climatic conditions. The “lab designed” CIR will allow the pavement designer to take the properties of the CIR into account when determining the overlay thickness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A previously developed high performance liquid chromatography mass spectrometry (HPLC-MS) procedure for the simultaneous determination of antidementia drugs, including donepezil, galantamine, memantine, rivastigmine and its metabolite NAP 226-90, was transferred to an ultra performance liquid chromatography system coupled to a tandem mass spectrometer (UPLC-MS/MS). The drugs and their internal standards ([(2)H(7)]-donepezil, [(13)C,(2)H(3)]-galantamine, [(13)C(2),(2)H(6)]-memantine, [(2)H(6)]-rivastigmine) were extracted from 250μL human plasma by protein precipitation with acetonitrile. Chromatographic separation was achieved on a reverse phase column (BEH C18 2.1mm×50mm; 1.7μm) with a gradient elution of an ammonium acetate buffer at pH 9.3 and acetonitrile at a flow rate of 0.4mL/min and an overall run time of 4.5min. The analytes were detected on a tandem quadrupole mass spectrometer operated in positive electrospray ionization mode, and quantification was performed using multiple reaction monitoring. The method was validated according to the recommendations of international guidelines over a calibration range of 1-300ng/mL for donepezil, galantamine and memantine, and 0.2-50ng/mL for rivastimgine and NAP 226-90. The trueness (86-108%), repeatability (0.8-8.3%), intermediate precision (2.3-10.9%) and selectivity of the method were found to be satisfactory. Matrix effects variability was inferior to 15% for the analytes and inferior to 5% after correction by internal standards. A method comparison was performed with patients' samples showing similar results between the HPLC-MS and UPLC-MS/MS procedures. Thus, this validated UPLC-MS/MS method allows to reduce the required amount of plasma, to use a simplified sample preparation, and to obtain a higher sensitivity and specificity with a much shortened run-time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many routes have been described for percutaneous adrenal gland biopsy. They require either a complex non-axial path or a long hydrodissection or even pass through an organ thereby increasing complications. We describe here an approach using an artificially-induced carbon dioxide (CO2) pneumothorax, performed as an outpatient procedure in a 57-year-old woman. Under local anaesthesia, 200 ml of CO2 was injected in the pleural space through a Veress needle under computed tomography fluoroscopy, to clear the lung parenchyma from the biopsy route. Using this technique, transthoracic adrenal biopsy can be performed under simple local anaesthesia as an safely outpatient procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a simple adaptive procedure for playing a game. In thisprocedure, players depart from their current play with probabilities thatare proportional to measures of regret for not having used other strategies(these measures are updated every period). It is shown that our adaptiveprocedure guaranties that with probability one, the sample distributionsof play converge to the set of correlated equilibria of the game. Tocompute these regret measures, a player needs to know his payoff functionand the history of play. We also offer a variation where every playerknows only his own realized payoff history (but not his payoff function).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Standard surgical aortic valve replacement with a biological prosthesis remains the treatment of choice for low- and mid-risk elderly patients (traditionally >65 years of age) suffering from severe symptomatic aortic valve stenosis or insufficiency, and for young patients with formal contraindications to long-lasting anticoagulation. Unfortunately, despite the fact that several technical improvements have noticeably improved the resistance of pericardial and bovine bioprostheses to leaflet calcifications and ruptures, the risk of early valve failure with rapid degeneration still exists, especially for patients under haemodialysis and for patients <60 years of age at the time of surgery. Until now, redo open heart surgery under cardiopulmonary bypass and on cardioplegic arrest was the only available therapeutic option in case of bioprosthesis degeneration, but it carried a higher surgical risk when elderly patients with severe concomitant comorbidities were concerned. Since a few years, the advent of new transcatheter aortic valve procedures has opened new horizons in cardiac surgery and, in particular, the possibility of implanting stented valves within the degenerated stented bioprosthesis, the so-called 'valve-in-valve' (VinV) concept, has become a clinical practice in experienced cardiac centres. The VinV procedure represents a minimally invasive approach dedicated to high-risk redo patients, and published preliminary reports have shown a success rate of 100% with absence of significant valvular leaks, acceptable transvalvular gradients and low complication rate. However, this procedure is not riskless and the most important concerns are about the size mismatch and the right positioning within the degenerated bioprosthesis. In this article, we review the limited available literature about VinV procedures, underline important technical details for the positioning and provide guidelines to prevent valve-prosthesis mismatch comparing the three sizes of the only commercially available transapical device, the Edwards Sapien, with the inner diameter of three of the most commonly used stented bioprostheses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We estimate four models of female labour supply using a Spanish sampleof married women from 1994, taking into account the complete form of theindividual s budget set. The models differ in the hypotheses relating tothe presence of optimisation errors and/or the way non-workers contributeto the likelihood function. According to the results, the effects of wagesand non-labour income on the labour supply of Spanish married women dependon the specification used. The model which has both preference andoptimisation errors and allows for both voluntarily and involuntarilyunemployed females desiring to participate seems to better fit the evidencefor Spanish married women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A significant postoperative problem in patients undergoing excision of intramedullary tumors is painful dysesthesiae, attributed to various causes, including edema, arachnoid scarring and cord tethering. The authors describe a technique of welding the pia and arachnoid after the excision of intramedullary spinal cord tumors used in seven cases. Using a fine bipolar forcep and a low current, the pial edges of the myelotomy were brought together and welded under saline irrigation. A similar method was used for closing the arachnoid while the dura was closed with a running 5-0 vicryl suture. Closing the pia and arachnoid restores normal cord anatomy after tumor excision and may reduce the incidence of postoperative painful dysesthesiae.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

My research in live drawing and new technologies uses a combination of a human figure in live in composition, overlaid with a digital projection of a second human figure. The aim is to explore, to amplify and thoroughly analyse the search for distinctive identities and graphic languages of representation for live and projected models.