922 resultados para Voltage instability
Resumo:
Permanent magnet generators (PMG) represent the cutting edge technology in modern wind mills. The efficiency remains high (over 90%) at partial loads. To improve the machine efficiency even further, every aspect of machine losses has to be analyzed. Additional losses are often given as a certain percentage without providing any detailed information about the actual calculation process; meanwhile, there are many design-dependent losses that have an effect on the total amount of additional losses and that have to be taken into consideration. Additional losses are most often eddy current losses in different parts of the machine. These losses are usually difficult to calculate in the design process. In this doctoral thesis, some additional losses are identified and modeled. Further, suggestions on how to minimize the losses are given. Iron losses can differ significantly between the measured no-load values and the loss values under load. In addition, with embedded magnet rotors, the quadrature-axis armature reaction adds losses to the stator iron by manipulating the harmonic content of the flux. It was, therefore, re-evaluated that in salient pole machines, to minimize the losses and the loss difference between the no-load and load operation, the flux density has to be kept below 1.5 T in the stator yoke, which is the traditional guideline for machine designers. Eddy current losses may occur in the end-winding area and in the support structure of the machine, that is, in the finger plate and the clamping ring. With construction steel, these losses account for 0.08% of the input power of the machine. These losses can be reduced almost to zero by using nonmagnetic stainless steel. In addition, the machine housing may be subjected to eddy current losses if the flux density exceeds 1.5 T in the stator yoke. Winding losses can rise rapidly when high frequencies and 10–15 mm high conductors are used. In general, minimizing the winding losses is simple. For example, it can be done by dividing the conductor into transposed subconductors. However, this comes with the expense of an increase in the DC resistance. In the doctoral thesis, a new method is presented to minimize the winding losses by applying a litz wire with noninsulated strands. The construction is the same as in a normal litz wire but the insulation between the subconductors has been left out. The idea is that the connection is kept weak to prevent harmful eddy currents from flowing. Moreover, the analytical solution for calculating the AC resistance factor of the litz-wire is supplemented by including an end-winding resistance in the analytical solution. A simple measurement device is developed to measure the AC resistance in the windings. In the case of a litz-wire with originally noninsulated strands, vacuum pressure impregnation (VPI) is used to insulate the subconductors. In one of the two cases studied, the VPI affected the AC resistance factor, but in the other case, it did not have any effect. However, more research is needed to determine the effect of the VPI on litz-wire with noninsulated strands. An empirical model is developed to calculate the AC resistance factor of a single-layer formwound winding. The model includes the end-winding length and the number of strands and turns. The end winding includes the circulating current (eddy currents that are traveling through the whole winding between parallel strands) and the main current. The end-winding length also affects the total AC resistance factor.
Resumo:
An early experiment found that a square rubber sheet under symmetric biaxial loading may not remain square. This curious result has been one of the most instructive examples in finite elasticity. Here thermodynamic considerations are used to analyze this instability.
Resumo:
Polarization curves experimentally obtained in the electro-dissolution of iron in a 1 M H2SO4 solution using a rotating disc as the working electrode present a current instability region within the range of applied voltage in which the current is controlled by mass transport in the electrolyte. According to the literature (Barcia et. al., 1992) the electro-dissolution process leads to the existence of a viscosity gradient in the interface metal-solution, which leads to a velocity field quantitatively different form the one developed in uniform viscosity conditions and may affect the stability of the hydrodynamic field. The purpose of this work is to investigate whether a steady viscosity profile, depending on the distance to the electrode surface, affects the stability properties of the classic velocity field near a rotating disc. Two classes of perturbations are considered: perturbations monotonically varying along the radial direction, and perturbations periodically modulated along the radial direction. The results show that the hydrodynamic field is always stable with respect to the first class of perturbations and that the neutral stability curves are modified by the presence of a viscosity gradient in the second case, in the sense of reducing the critical Reynolds number beyond which perturbations are amplified. This result supports the hypothesis that the current oscillations observed in the polarization curve may originate from a hydrodynamic instability.
Resumo:
Permanent magnet drives with nominal power over 10 kW were not a cost-sufficient system 25 years ago due to high material expenses. The improvements in motor drives, the rise in competition and the tightening of standards and regulations have caused that the PM-drives are more and more common in the over 10 kW nominal power range. The goal of this thesis is to research the performance in relation to nominal power of a PM-drive technique that is vastly increasing its popularity in fan related devices. The studied motor technique brushless direct current drive (BLDC) consists of a voltage source inverter, permanent motor and six-step-control. The reference drive is a brushless alternating current drive (BLAC) which consists of a VSI, PM and a hysteresis control. As a conclusion there are no major obstacles that would impede the BLDC-drive technique from expanding to larger power stages. The following factors must be taken into consideration when designing a BLDC-drive: motor’s current change rate, inverter switching frequency, motor’s nominal electric frequency, phase inductance and the current handling capability of the inverter. The fluctuating material costs create instability to the end prices of PM-motors that can in the worst case lead to diminished interest towards BLDC- and PM-drives in general.
Resumo:
Several human genetic syndromes have long been recognized to be defective in DNA repair mechanisms. This was first discovered by Cleaver (1968), who showed that cells from patients with xeroderma pigmentosum (XP) were defective for the ability to remove ultraviolet (UV)-induced lesions from their genome. Since then, new discoveries have promoted DNA repair studies to one of the most exciting areas of molecular biology. The present work intends to give a brief summary of the main known human genetic diseases related to DNA repair and how they may be linked to acquired diseases such as cancer
Resumo:
The influence of voltage on the conductance of toad skin was studied to identify the time course of the activation/deactivation dynamics of voltage-dependent Cl- channels located in the apical membrane of mitochondrion-rich cells in this tissue. Positive apical voltage induced an important conductance inhibition which took a few seconds to fully develop and was instantaneously released by pulse inversion to negative voltage, indicating a short-duration memory of the inhibiting factors. Sinusoidal stimulation at 23.4 mM [Cl-] showed hysteresis in the current versus voltage curves, even at very low frequency, suggesting that the rate of voltage application was also relevant for the inhibition/releasing effect to develop. We conclude that the voltage modulation of apical Cl- permeability is essentially a fast process and the apparent slow components of activation/deactivation obtained in the whole skin are a consequence of a gradual voltage build-up across the apical membrane due to voltage sharing between apical and basolateral membranes
Resumo:
Recent technological developments have created new devices that could improve and simplify the construction of stimulus isolators. HEXFET transistors can switch large currents and hundreds of volts in nanoseconds. The newer opto-isolators can give a pulse rise time of a few nanoseconds, with output compatible with MOSFET devices, in which delays are reduced to nanoseconds. Integrated DC/DC converters are now available. Using these new resources we developed a new electrical stimulus isolator circuit with selectable constant-current and constant-voltage modes, which are precise and easy to construct. The circuit works like a regulated power supply in both modes with output switched to zero or to free mode through an opto-isolator device. The isolator analyses showed good practical performance. The output to ground resistance was 1011 ohms and capacitance 35 picofarads. The rise time and fall time were identical (5 µs) and constant. The selectable voltage or current output mode made it very convenient to use. The current mode, with higher output resistance values in low current ranges, permits intracellular stimulation even with tip resistances close to 100 megaohms. The high compliance of 200 V guarantees the value of the current stimulus. The very low output resistance in the voltage mode made the device highly suitable for extracellular stimulation with low impedance electrodes. Most importantly, these characteristics were achieved with a circuit that was easy to build and modify and assembled with components available in Brazil.
Resumo:
Microsatellites are short tandem repeat sequences dispersed throughout the genome. Their instability at multiple genetic loci may result from mismatch repair errors and it occurs in hereditary nonpolyposis colorectal cancer. This instability is also found in many sporadic cancers. In order to evaluate the importance of this process in myeloid leukemias, we studied five loci in different chromosomes of 43 patients, 22 with chronic myelocytic leukemia (CML) in the chronic phase, 7 with CML in blast crisis, and 14 with acute myeloid leukemia (AML), by comparing leukemic DNA extracted from bone marrow and constitutional DNA obtained from buccal epithelial cells. Only one of the 43 patients (2.1%), with relapsed AML, showed an alteration in the allele length at a single locus. Cytogenetic analysis was performed in order to improve the characterization of leukemic subtypes and to determine if specific chromosome aberrations were associated with the presence of microsatellite instability. Several chromosome aberrations were observed, most of them detected at diagnosis and during follow-up of the patients, according to current literature. These findings suggest that microsatellite instability is an infrequent genetic event in myeloid leukemias, adding support to the current view that the mechanisms of genomic instability in solid tumors differ from those observed in leukemias, where specific chromosome aberrations seem to play a major role.
Resumo:
Hereditary spherocytosis (HS) is a common inherited anemia characterized by the presence of spherocytic red cells. Defects in several membrane protein genes have been involved in the pathogenesis of HS. ß-Spectrin-related HS seems to be common. We report here a new mutation in the ß-spectrin gene coding region in a patient with hereditary spherocytosis. The patient presented acanthocytosis and spectrin deficiency and, at the DNA level, a novel frameshift mutation leading to HS, i.e., a C deletion at codon 1392 (ß-spectrin São PauloII), exon 20. The mRNA encoding ß-spectrin São PauloII was very unstable and the mutant protein was not detected in the membrane or in other cellular compartments. It is interesting to note that frameshift mutations of the ß-spectrin gene at the 3' end allow the insertion of the mutant protein in the red cell membrane, leading to a defect in the auto-association of the spectrin dimers and consequent elliptocytosis. On the other hand, ß-spectrin São PauloII protein was absent in the red cell membrane, leading to spectrin deficiency, HS and the presence of acanthocytes.
Resumo:
The effect of the skin secretion of the amphibian Siphonops paulensis was investigated by monitoring the changes in conductance of an artificial planar lipid bilayer. Skin secretion was obtained by exposure of the animals to ether-saturated air, and then rinsing the animals with distilled water. Artificial lipid bilayers were obtained by spreading a solution of azolectin over an aperture of a Delrin cup inserted into a cut-away polyvinyl chloride block. In 9 of 12 experiments, the addition of the skin secretion to lipid bilayers displayed voltage-dependent channels with average unitary conductance of 258 ± 41.67 pS, rather than nonspecific changes in bilayer conductance. These channels were not sensitive to 4-acetamido-4'-isothiocyanatostilbene-2,2'-disulfonic acid or tetraethylammonium ion, but the experimental protocol used does not permit us to specify their characteristics.
Resumo:
The objective of the present study was to evaluate the expression of a cyclic alternating pattern (CAP) in slow wave sleep (SWS) in children with the well-defined chronic syndrome juvenile idiopathic arthritis (JIA). Twelve patients (9-17 years of age), 7 girls, with JIA were compared to matched controls by age, pubertal stage and gender. After one night of habituation in the sleep laboratory, sleep measurements were obtained by standard polysomnography with conventional sleep scoring and additional CAP analyses. The sleep parameters of the JIA and control groups were similar for sleep efficiency (91.1 ± 6.7 vs 95.8 ± 4.0), sleep stage in minutes: stage 1 (16.8 ± 8.5 vs 17.8 ± 4.0), stage 2 (251.9 ± 41 vs 262.8 ± 38.1), stage 3 (17.0 ± 6.0 vs 15.1 ± 5.7), stage 4 (61.0 ± 21.7 vs 77.1 ± 20.4), and rapid eye movement sleep (82.0 ± 27.6 vs 99.0 ± 23.9), respectively. JIA patients presented nocturnal disrupted sleep, with an increase in short awakenings, but CAP analyses showed that sleep disruption was present even during SWS, showing an increase in the overall CAP rate (P < 0.01). Overall CAP rate during non-rapid eye movement sleep was significantly higher in pediatric patients who were in chronic pain. This is the first study of CAP in pediatric patients with chronic arthritis showing that CAP analyses can be a powerful tool for the investigation of disturbance of SWS in children, based on sleep EEG visual analysis.
Resumo:
Our aim was to investigate the role of chemokines in promoting instability of coronary atherosclerotic plaques and the underlying molecular mechanism. Coronary angiography and intravascular ultrasound (IVUS) were performed in 60 stable angina pectoris (SAP) patients and 60 unstable angina pectoris (UAP) patients. The chemotactic activity of monocytes in the 2 groups of patients was examined in Transwell chambers. High-sensitivity C-reactive protein (hs-CRP), monocyte chemoattractant protein-1 (MCP-1), regulated on activation in normal T-cell expressed and secreted (RANTES), and fractalkine in serum were examined with ELISA kits, and expression of MCP-1, RANTES, and fractalkine mRNA was examined with real-time PCR. In the SAP group, 92 plaques were detected with IVUS. In the UAP group, 96 plaques were detected with IVUS. The plaques in the UAP group were mainly lipid 51.04% (49/96) and the plaques in the SAP group were mainly fibrous 52.17% (48/92). Compared with the SAP group, the plaque burden and vascular remodeling index in the UAP group were significantly greater than in the SAP group (P<0.01). Chemotactic activity and the number of mobile monocytes in the UAP group were significantly greater than in the SAP group (P<0.01). Concentrations of hs-CRP, MCP-1, RANTES, and fractalkine in the serum of the UAP group were significantly higher than in the serum of the SAP group (P<0.05 or P<0.01), and expression of MCP-1, RANTES, and fractalkine mRNA was significantly higher than in the SAP group (P<0.05). MCP-1, RANTES, and fractalkine probably promote instability of coronary atherosclerotic plaque.
Resumo:
Today, renewable energy technologies and modern power electronics have made it feasible to implement low voltage direct current (LVDC) microgrids (MGs) ca-pable to island operation. Such LVDC networks are particularly useful in remote areas. However, there are still pending issues in island operated LVDC MGs like electrical safety and controlled operation, which should be addressed before wide-scale implementation. This thesis is focused on the overall protection of an island operated LVDC network concept, including protection against electrical shocks, mains equipment protection and protection of photovoltaic (PV) power sources and battery energy storage systems (BESSs). The topic is approached through ex-amination of the safety hazards and the appropriate methods to protect against them, comprising considerations for earthing system selection and realisation of the protection system.
Power Electronic Converters in Low-Voltage Direct Current Distribution – Analysis and Implementation
Resumo:
Over the recent years, smart grids have received great public attention. Many proposed functionalities rely on power electronics, which play a key role in the smart grid, together with the communication network. However, “smartness” is not the driver that alone motivates the research towards distribution networks based on power electronics; the network vulnerability to natural hazards has resulted in tightening requirements for the supply security, set both by electricity end-users and authorities. Because of the favorable price development and advancements in the field, direct current (DC) distribution has become an attractive alternative for distribution networks. In this doctoral dissertation, power electronic converters for a low-voltage DC (LVDC) distribution system are investigated. These include the rectifier located at the beginning of the LVDC network and the customer-end inverter (CEI) on the customer premises. Rectifier topologies are introduced, and according to the LVDC system requirements, topologies are chosen for the analysis. Similarly, suitable CEI topologies are addressed and selected for study. Application of power electronics into electricity distribution poses some new challenges. Because the electricity end-user is supplied with the CEI, it is responsible for the end-user voltage quality, but it also has to be able to supply adequate current in all operating conditions, including a short-circuit, to ensure the electrical safety. Supplying short-circuit current with power electronics requires additional measures, and therefore, the short-circuit behavior is described and methods to overcome the high-current supply to the fault are proposed. Power electronic converters also produce common-mode (CM) and radio-frequency (RF) electromagnetic interferences (EMI), which are not present in AC distribution. Hence, their magnitudes are investigated. To enable comprehensive research on the LVDC distribution field, a research site was built into a public low-voltage distribution network. The implementation was a joint task by the LVDC research team of Lappeenranta University of Technology and a power company Suur-Savon S¨ahk¨o Oy. Now, the measurements could be conducted in an actual environment. This is important especially for the EMI studies. The main results of the work concern the short-circuit operation of the CEI and the EMI issues. The applicability of the power electronic converters to electricity distribution is demonstrated, and suggestions for future research are proposed.