927 resultados para Voice detectors


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis is mainly about the search for exotic heavy particles -Intermediate Mass Magnetic Monopoles, Nuclearites and Q-balls with the SLIM experiment at the Chacaltaya High Altitude Laboratory (5230 m, Bolivia), establishing upper limits (90% CL) in the absence of candidates, which are among the best if not the only one for all three kind of particles. A preliminary study of the background induced by cosmic neutron in CR39 at the SLIM site, using Monte Carlo simulations. The measurement of the elemental abundance of the primary cosmic ray with the CAKE experiment on board of a stratospherical balloon; the charge distribution obtained spans in the range 5≤Z≤31. Both experiments were based on the use of plastic Nuclear Track Detectors, which records the passage of ionizing particles; by using some chemical reagents such passage can be make visible at optical microscopes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monte Carlo (MC) simulation techniques are becoming very common in the Medical Physicists community. MC can be used for modeling Single Photon Emission Computed Tomography (SPECT) and for dosimetry calculations. 188Re, is a promising candidate for radiotherapeutic production and understanding the mechanisms of the radioresponse of tumor cells "in vitro" is of crucial importance as a first step before "in vivo" studies. The dosimetry of 188Re, used to target different lines of cancer cells, has been evaluated by the MC code GEANT4. The simulations estimate the average energy deposition/per event in the biological samples. The development of prototypes for medical imaging, based on LaBr3:Ce scintillation crystals coupled with a position sensitive photomultiplier, have been studied using GEANT4 simulations. Having tested, in the simulation, surface treatments different from the one applied to the crystal used in our experimental measurements, we found out that the Energy Resolution (ER) and the Spatial Resolution (SR) could be improved, in principle, by machining in a different way the lateral surfaces of the crystal. We have then studied a system able to acquire both echographic and scintigraphic images to let the medical operator obtain the complete anatomic and functional information for tumor diagnosis. The scintigraphic part of the detector is simulated by GEANT4 and first attempts to reconstruct tomographic images have been made using as method of reconstruction a back-projection standard algorithm. The proposed camera is based on slant collimators and LaBr3:Ce crystals. Within the Field of View (FOV) of the camera, it possible to distinguish point sources located in air at a distance of about 2 cm from each other. In particular conditions of uptake, tumor depth and dimension, the preliminary results show that the Signal to Noise Ratio (SNR) values obtained are higher than the standard detection limit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To date the hospital radiological workflow is completing a transition from analog to digital technology. Since the X-rays digital detection technologies have become mature, hospitals are trading on the natural devices turnover to replace the conventional screen film devices with digital ones. The transition process is complex and involves not just the equipment replacement but also new arrangements for image transmission, display (and reporting) and storage. This work is focused on 2D digital detector’s characterization with a concern to specific clinical application; the systems features linked to the image quality are analyzed to assess the clinical performances, the conversion efficiency, and the minimum dose necessary to get an acceptable image. The first section overviews the digital detector technologies focusing on the recent and promising technological developments. The second section contains a description of the characterization methods considered in this thesis categorized in physical, psychophysical and clinical; theory, models and procedures are described as well. The third section contains a set of characterizations performed on new equipments that appears to be some of the most advanced technologies available to date. The fourth section deals with some procedures and schemes employed for quality assurance programs.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nell'era di Internet e della digitalizzazione, anche la telefonia ha avuto la possibilità di evolversi, e grazie alle tecnologie Voice-over-IP è stato possibile realizzare servizi di comunicazione avanzata su reti di dati. Anche se la comunicazione vocale è l'aspetto chiave di questi sistemi, le reti VoIP supportano altri tipi di servizi, tra cui video, messaggistica istantanea, condivisione di file, ecc. Il successo di questa nuova tipologia di rete è dovuto ad una migliore flessibilità rispetto ai vecchi sistemi analogici, grazie ad architetture aperte e implementazioni a livello software, e soprattutto ad un minor costo legato alle apparecchiature ed ai collegamenti utilizzati, ed ai nuovi modelli di business e di consumo sempre più orientati allo sfruttamento della connettività a banda larga. Tuttavia, l'implementazione dei sistemi VoIP rappresenta anche un grado di complessità maggiore in termini di architetture di rete, di protocolli, e di implementazione, e con questo ne segue un incremento delle possibili vulnerabilità. Una falla nella sicurezza in questi sistemi può portare a disservizi e violazione della privacy per gli utenti con conseguenti ripercussioni economiche per i relativi gestori. La tesi analizza la sicurezza delle reti VoIP concentrandosi sul protocollo che sta alla base dei servizi multimediali, il protocollo SIP. SIP è un protocollo di livello applicativo realizzato per creare, modificare e terminare delle sessioni multimediali tra due o più utenti. Dopo un'introduzione alle generalità del protocollo, vengono esaminate le classi di vulnerabilità delle reti VoIP e gli attacchi a SIP, e vengono presentate alcune contromisure attuabili. Viene mostrato un esempio di come vengano attuati alcuni dei principali attacchi a SIP tramite l'utilizzo di appositi strumenti. L'eborato conclude con alcune considerazioni sulle minacce al protocollo e sugli obiettivi futuri che la comunità scientifica dovrebbe perseguire.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Investigating parents’ formal engagement opportunities in public schools serves well to characterize the relationship between states and societies. While the relationship between parental involvement and students’ academic success has been thoroughly investigated, rarely has it been seen to indicate countries’ governing regimes. The researcher was curious to see whether and how does parents’ voice differ in different democracies. The hypothesis was that in mature regimes, institutional opportunities for formal parental engagement are plenty and parents are actively involved; while in young democracies there are less opportunities and the engagement is lower. The assumption was also that parental deliberation in expressing their dissatisfaction with schools differs across democracies: where it is more intense, there it translates to higher engagement. Parents’ informedness on relevant regulations and agendas was assumed to be equally average, and their demographic background to have similar effects on engagement. The comparative, most different systems design was employed where public middle schools last graders’ parents in Tartu, Estonia and in Huntsville, Alabama the United States served as a sample. The multidimensional study includes the theoretical review, country and community analyses, institutional analysis in terms of formal parental involvement, and parents’ survey. The findings revealed sizeable differences between parents’ engagement levels in Huntsville and Tartu. The results indicate passivity in both communities, while in Tartu the engagement seems to be alarmingly low. Furthermore, Tartu parents have much less institutional opportunities to engage. In the United States, multilevel efforts to engage parents are visible from local to federal level, in Estonia similar intentions seem to be missing and meaningful parental organizations do not exist. In terms of civic education there is much room for development in both countries. The road will be longer for a young democracy Estonia in transforming its institutional systems from formally democratic to inherently inclusive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Future experiments in nuclear and particle physics are moving towards the high luminosity regime in order to access rare processes. In this framework, particle detectors require high rate capability together with excellent timing resolution for precise event reconstruction. In order to achieve this, the development of dedicated FrontEnd Electronics (FEE) for detectors has become increasingly challenging and expensive. Thus, a current trend in R&D is towards flexible FEE that can be easily adapted to a great variety of detectors, without impairing the required high performance. This thesis reports on a novel FEE for two different detector types: imaging Cherenkov counters and plastic scintillator arrays. The former requires high sensitivity and precision for detection of single photon signals, while the latter is characterized by slower and larger signals typical of scintillation processes. The FEE design was developed using high-bandwidth preamplifiers and fast discriminators which provide Time-over-Threshold (ToT). The use of discriminators allowed for low power consumption, minimal dead-times and self-triggering capabilities, all fundamental aspects for high rate applications. The output signals of the FEE are readout by a high precision TDC system based on FPGA. The performed full characterization of the analogue signals under realistic conditions proved that the ToT information can be used in a novel way for charge measurements or walk corrections, thus improving the obtainable timing resolution. Detailed laboratory investigations proved the feasibility of the ToT method. The full readout chain was investigated in test experiments at the Mainz Microtron: high counting rates per channel of several MHz were achieved, and a timing resolution of better than 100 ps after walk correction based on ToT was obtained. Ongoing applications to fast Time-of-Flight counters and future developments of FEE have been also recently investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Negli anni recenti, lo sviluppo dell’elettronica organica ha condotto all’impiego di materiali organici alla base di numerosi dispositivi elettronici, quali i diodi ad emissione di luce, i transistor ad effetto di campo, le celle solari e i rivelatori di radiazione. Riguardo quest’ultimi, gli studi riportati in letteratura si riferiscono per la maggiore a dispositivi basati su materiali organici a film sottile, che tuttavia presentano problemi relativi ad instabilità e degradazione. Come verrà illustrato, l’impiego di singoli cristalli organici come materiali alla base di questi dispositivi permette il superamento delle principali limitazioni che caratterizzano i rivelatori basati su film sottili. In questa attività sperimentale, dispositivi basati su cristalli organici semiconduttori verranno caratterizzati in base alle principali figure di merito dei rivelatori. Tra i campioni testati, alcuni dispositivi basati su singoli cristalli di 6,13-bis (triisopropylsilylethynyl)-pentacene (TIPS-Pentacene) e 5,6,11,12-tetraphenyltetracene (Rubrene) hanno mostrato interessanti proprietà e sono stati quindi maggiormente studiati.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional inorganic materials for x-ray radiation sensors suffer from several drawbacks, including their inability to cover large curved areas, me- chanical sti ffness, lack of tissue-equivalence and toxicity. Semiconducting organic polymers represent an alternative and have been employed as di- rect photoconversion material in organic diodes. In contrast to inorganic detector materials, polymers allow low-cost and large area fabrication by sol- vent based methods. In addition their processing is compliant with fexible low-temperature substrates. Flexible and large-area detectors are needed for dosimetry in medical radiotherapy and security applications. The objective of my thesis is to achieve optimized organic polymer diodes for fexible, di- rect x-ray detectors. To this end polymer diodes based on two different semi- conducting polymers, polyvinylcarbazole (PVK) and poly(9,9-dioctyluorene) (PFO) have been fabricated. The diodes show state-of-the-art rectifying be- haviour and hole transport mobilities comparable to reference materials. In order to improve the X-ray stopping power, high-Z nanoparticle Bi2O3 or WO3 where added to realize a polymer-nanoparticle composite with opti- mized properities. X-ray detector characterization resulted in sensitivties of up to 14 uC/Gy/cm2 for PVK when diodes were operated in reverse. Addition of nanoparticles could further improve the performance and a maximum sensitivy of 19 uC/Gy/cm2 was obtained for the PFO diodes. Compared to the pure PFO diode this corresponds to a five-fold increase and thus highlights the potentiality of nanoparticles for polymer detector design. In- terestingly the pure polymer diodes showed an order of magnitude increase in sensitivity when operated in forward regime. The increase was attributed to a different detection mechanism based on the modulation of the diodes conductivity.