876 resultados para Visual Analog Scale
Resumo:
Introduction: The Temporomandibular disorder (TMD) is greatly prevalent in the population and can be associated with bruxism. This disorder produces several signs and symptoms. Among them, pain is one of the most important because it reduces life quality and productivity of people who have such disorder. The aim of this research was to study if massage causes pain relief and/or electromyographic (EMG) changes. Materials and methods: The subjects were chosen by a questionnaire and divided into 2 different groups. Their ages varied from 19 to 22 years. The experimental group consisted of 6 TMD patients, who were submitted to the massage treatment and 4 EMG-sessions (the 1 st EMG-session occurred before the treatment and the others in the 1 st, 15 th and 30 th days after the treatment). The control group consisted of 6 TMD patients, who were submitted to the same 4 EMG-sessions. While EMG activity was recorded, subjects were asked to keep mandibular rest position (MRP) and to perform maximal voluntary clenching (MVC). The treatment consisted of 15 massage-sessions on face and neck and in application of Visual Analogue Scale (VAS) for measuring pain level. The massage sessions had 30 minutes of duration and were performed daily. The EMG data were processed to obtain the Root Mean Square (RMS), which were normalized by MVC. Results: It was demonstrated that (1) RMS-MRP of the right masseter in experimental group at the 1 st EMG-session was higher than at the 2 nd EMG-session and (2) statistically significant reduction was found for VAS values after massage session. Conclusion: Unfortunately the sample is insufficient to draw any conclusions, therefore, more studies regarding the use of massage in the management of myogenic TMD are necessary.
Resumo:
The effect of Microcurrent Electrical Nerve Stimulation (MENS) was evaluated and compared with occlusal splint therapy in temporomandibular disorders (TMD) patients with muscle pain. Twenty TMD patients were divided into four groups. One received occlusal splint therapy and MENS (I); other received splints and placebo MENS (II); the third, only MENS (III) and the last group, placebo MENS (IV). Sensitivity derived from muscle palpation was evaluated using a visual analogue scale. Results were submitted to analysis of variance (p<0.05). There was reduction of pain level in all groups: group I (occlusal splint and MENS) had a 47.7% reduction rate; group II (occlusal splint and placebo MENS), 66.7%; group III (MENS), 49.7% and group IV (placebo MENS), 16.5%. In spite of that, there was no statistical difference (analysis of variance / p<0.05) between MENS and occlusal splint therapy regarding muscle pain reduction in TMD patients after four weeks.
Resumo:
The purpose of this study was to measure and verify the esthetic influence of the bilateral spaces between maxillary teeth and lip corners, called negative space (NS), during smile. The sample was comprised of 60 smile photographs obtained from 60 individuals (30 men and 30 women) aged 18 to 25 years old. Two orthodontists and two lay people evaluated these pictures regarding esthetics by a visual analogue scale. In each picture, the right and left NS were measured in millimeters and in proportion to the smile width (SW). Data were analyzed for statistical significance (P = .05). The mean NS of the sample was 6.68 ± 1.99 mm, and the NS proportion in relation to the SW was 9.6 ± 2.56%, for both sides of the arch. No significant asymmetries were observed between the right and left sides. The NS was significantly larger in men than in women when measured in millimeters (P = .028) (7.08 ± 2.24 mm in men vs 6.28 ± 1.62 mm in women), but the NS proportion to the SW was similar (9.94 ± 2.24% in men vs 9.26 ± 1.61% in women). When the 12 individuals with the smallest NS in proportion to SW were compared with the 12 individuals with the largest NS in proportion to SW, there was no statistical difference regarding the esthetic evaluation (P = .11). It was concluded that the NS did not influence the esthetic evaluation of smile photographs in the sample in this study, for both orthodontists and lay people. © 2006 by The EH Angle Education and Research Foundation, Inc.
Resumo:
Introduction: Needle infi ltration of local anesthetic is a painful procedure, thus, a topical anesthetic is a comfortable alternative; however, it is diffi cult to deliver transcutaneous polar drugs. Iontophoresis is a noninvasive technique that uses electrical current for releasing electrically charged drugs through biological membranes. Objective: To evaluate the anesthesia induced by iontophoresis of lidocaine for a standardized painful stimulus. Material and methods: Randomized, controlled, double-blind study, involving 10 volunteers under the anesthetic effects of topical application of lidocaine gel 2% and noradrenaline 1:50,000, with or without iontophoresis of 1.85 milliamps for 13 minutes. Pain sensitivity was evaluated by the prick of a 21G needle in the arms posterior region, using a visual numerical scale. Results: Patients mean age was 50.8 ± 11.4 years. Nine of them were women. All had previously received infi ltrative anesthesia. Iontophoresis was well tolerated by volunteers. The median pain scores were 0 and 3 for the arm that received the iontophoresis and for the one that did not receive, respectively (p < 0.01). Conclusion: The anesthetic effect in the region subjected to iontophoresis suggests an effi cient and comfortable method for promoting local anesthesia in the surgical approach of pediatric, hyperalgic, or needlephobic patients.
Resumo:
Purpose: To comparatively and prospectively compare in a randomized clinical trial, dentin hypersensitivity after treatment with three in-office bleaching systems, based on hydrogen peroxide at different concentrations, with and without light source activation. Methods: 88 individuals were included according to inclusion and exclusion criteria. Subjects were randomly divided into the following three treatment groups: Group 1 was treated with three 15-minute applications of hydrogen peroxide at 15% with titanium dioxide (Lase Peroxide Lite) that was light-activated (Light Plus Whitening Lase) with five cycles of 1 minute and 30 seconds each cycle, giving a total treatment time of 45 minutes; Group 2 was treated with three 10-minute applications of hydrogen peroxide at 35% (Lase Peroxide Sensy), activated by light (LPWL) same activation cycles than Group 1, with a total treatment time of 30 minutes; Group 3 was treated with only one application for 45 minutes of hydrogen peroxide at 35% (Whitegold Office) without light activation. Each subject underwent one session of bleaching on the anterior teeth according to the manufacturers' instructions. Dentin sensitivity was recorded with a visual analogue scale (VAS) at baseline, immediately after, and at 7 and 30 days after treatment using a stimulus of an evaporative blowing triple syringe for 3 seconds on the upper central incisors from a distance of 1 cm. A Kruskal-Wallis test followed by Mann-Whitney test was performed for statistical analysis. Results: All groups showed increased sensitivity immediately after treatment. Group 1 displayed less changes relative to baseline with no significant differences (P= 0.104). At 7 and 30 days after treatment, a comparison of VAS values indicated no significant differences between all groups (P= 0.598 and 0.489, respectively).
Resumo:
Introduction: Our objective was to determine the perception of smile esthetics among orthodontists and laypeople with respect to asymmetries on the maxillary incisor edges in a frontal smile analysis. Methods: Two frontal close-up smile photos of 2 women, 1 white and 1 Afro-Brazilian, were selected for this study. Both smiles displayed healthy maxillary anterior dentitions. The images were digitally altered to create tooth wear on the maxillary left central and lateral incisors in 0.5-mm increments. The final images were randomly assembled into a photo album that was given to 120 judges, 60 orthodontists and 60 laypersons. Each rater was asked to evaluate the attractiveness of the images with visual analog scales. The data collected were statistically analyzed with 1-way analysis of variance with the Tukey post-hoc test and the unpaired Student t test. Results: The most attractive smiles in both types of smiles were those without asymmetries and the 0.5-mm wear in the lateral incisor. In general, tooth wear was considered unattractive by both groups of raters following a pattern: the more tooth wear, the more unattractive the smile; tooth wear in the central incisor was considered more unattractive than in the lateral incisor. For both group of raters, 0.5 mm of wear in the central incisor was considered unattractive, whereas the thresholds for lateral incisor discrepancies were 0.5 mm for orthodontists and 1.0 mm for laypersons. Conclusions: The result of this study corroborates the clinical assumption that symmetry between the maxillary central incisors is a paramount goal for esthetic treatments. Copyright © 2013 by the American Association of Orthodontists.
Resumo:
A number of variables may influence the outcome of complete denture therapy. The objective of this study was to verify possible correlations between previous experience with dentures, patient expectation and the number of post-delivery adjustments with patient satisfaction after treatment. One hundred patients (mean age 61·9 ± 10·3) rated their previous experiences with complete dentures and their expectations before and satisfaction after treatment on a visual analogue scale (VAS) using scores from 0 (worst results) to 10 (best results). The number of post-delivery adjustments and other patient-related clinical variables was also noted. Patient expectation scores were higher than previous experience scores and satisfaction after treatment scores. Positive and weak correlations were found between previous chewing experiences with complete dentures, with regard to chewing expectations and comfort of use. Phonetics and comfort of use in previous experiences presented a positive correlation with expectations for chewing, aesthetics, phonetics and comfort of use. Groups of patients with different levels of education presented significant differences in expectation scores regarding comfort of use as well. A negative and weak correlation was found between phonetics satisfaction and the number of post-delivery adjustments. Patients' expectations for the therapy were higher than their satisfaction after treatment. Previous experiences with complete dentures could slightly influence patients' expectations and satisfaction, whereas lower scores for previous experience with complete dentures caused lower scores for both expectation and satisfaction. Patients' educational levels and the number of post-delivery adjustments influenced negatively the expectations about comfort of use and patient satisfaction, respectively. © 2013 John Wiley & Sons Ltd.
Resumo:
Background: The aim of this study was to evaluate the symptoms of dry mouth and salivary flow in menarche and menopausal women. Methods: Objective and subjective assessment of salivary function were analysed by Xerostomia Inventory and Visual Analogue Scale questionnaire in menopausal and menarche women (control group). Salivary flow was evaluated by a chemical absorption stimulation test. Each subject provided three saliva samples: S1, non-stimulated saliva; S2, saliva initially stimulated with two drops of citric acid 2.5%; and S3, saliva super-stimulated with two drops of citric acid 2.5% every 30 seconds for two minutes. Results: No intergroup association was observed between Xerostomia Inventory and Visual Analogue Scale questionnaire. In both groups, the salivary flow was greatest at S3, followed by S2 and finally S1. Salivary flow was lower in the menopausal group compared to the control group only in S2 and S3. Conclusions: In the menopausal group, the salivary flow showed reduction but without clinical symptoms of dry mouth. It is important to normalize salivary flow to prevent oral abnormalities and maintain oral health. © 2013 Australian Dental Association.
Resumo:
This study aimed to evaluate the post operative analgesic effects of morphine or ketamine alone or their combination in 24 healthy bitches, weighing 11.01±8.69kg and aging 27±17 months, submitted to elective ovariohysterectomy. The animals were distributed to one of the three treatments after the anaesthetic induction: morphine (GM, n=8, 0.5mg kg-1 IM), ketamine (GK, n=8, 2.5mg kg-1 IM) or ketamine combined to morphine (GKM) using the same doses previously described. Sedation score and pain assessment were performed blindly two hours before surgery and at 1, 2, 4, 8, 12, and 24 hours after extubation, using the Dobbins scale (sedation) and visual analogue scale (pain) and Glasgow modified pain scale (GMPS). Rescue analgesia was performed with 1.0mg kg-1 of morphine and if not sufficient, followed by 0.2mg kg-1 of meloxicam, both IM, when the GMPS reached above 33% of the total score. Non parametric data were analyzed using Friedmańs test followed by Dunńs test for differences in time. Kruskal-Walliś test followed by Dunńs test were used to investigate differences in the number of analgesic rescues and among groups at each time. Parametric data were evaluated by ANOVA followed by Tukey's test (P<0.05). Except for GMPS, where the values of GM were greater than for GKM at 1h post-extubation, there were no other differences among groups. The number of rescue analgesia was greater in GM (11 in total; twice in 3 animals,) when compared to GKM (3; twice in 1 animal) and GK (2; twice in 1 animal). Analgesia provided by pre-incisional ketamine was more effective when compared to morphine. According to that, ketamine alone may be used as a preemptive analgesic in bitches undergoing ovariohysterectomy; however, rescue analgesia may be necessary.
Resumo:
Since all analgesics currently available for use in dogs have been associated with some adverse effects, the search for an effective analgesic that does not cause harm is important. This study investigated the postoperative analgesic effects of ozone administered either intrarectally or into acupoints in bitches undergoing ovariohysterectomy (OH). Twenty-four healthy adult bitches were randomly assigned to one of the three treatments 10min after sedation, as follows: 0.2mg/kg of intramuscular (IM) meloxicam (M); rectal insufflation of 10mL of 30μg/mL ozone (OI), or acupoint injection of 0.5mL ozone (30μg/mL; OA). Following sedation with acetylpromazine, anaesthesia was induced with propofol and fentanyl and maintained with isoflurane/O2. Pain was assessed using the modified Glasgow pain scale (MGPS) and the visual analogue scale (VAS) on the day before surgery, before anaesthesia, and at 1, 2, 4, 6, 8, 12 and 24h after surgery. Rescue analgesia was performed using 0.5mg/kg of morphine IM if MGPS was >3.33 points.No statistically significant differences in pain scales were found among the three analgesic protocols or the time points in each group ( P>. 0.05). Two dogs treated with OA required rescue analgesia. Meloxicam, rectal insufflation of ozone and ozone injected into acupoints provided satisfactory analgesia for 24. h in bitches undergoing elective OH. Ozone had no measurable adverse effects and is an alternative option to promote pain relief. © 2013 Elsevier Ltd.
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Pós-graduação em Agronomia (Agricultura) - FCA
Resumo:
Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)