994 resultados para Vision disorders


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the role of corneal endothelial surface enlargement in the chicken myopia model in inducing corneal endothelial changes. Methods: Lid suture was performed on one eye of 1-day-old cockerels. Five chickens were killed at 1 week, and four chickens killed at each of 3 weeks, 6 weeks, and 10 weeks postnatal. The endothelial morphology was obtained by flat mounting the endothelial surface and the subsequent digitisation. Comparisons were undertaken between the control unsutured eye and the lid-sutured eye endothelium, and between the central endothelial areas compared to the peripheral endothelial areas in both the myopic and the normal corneas. Calculation of the contribution to the endothelial change by hypertrophy and mitosis were calculated using Bahn's formula. Results: Total endothelial surface area increased significantly over time in the myopic model compared to control eyes but the mean cell area of endothelial cells remained the same for both the enlarged myopic endothelial surface area and in the normal controls. Sampling from the central and the peripheral corneal endothelial surface also disclosed no difference. The mean cell area did increase steadily with age but was the same for both normal and myopic corneas. Conclusions: It would appear that there are equal contributions from hypertrophy and mitosis in the myopic group and the normal corneal group with a slightly increasing trend towards mitotic activity in the myopic corneal endothelial layer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To assess the practices in pterygium removal as a follow-up study to a similar project 10 years ago, in order to compare the current trends with those noted a decade ago. Methods: A survey was sent to all practising ophthalmologists in Queensland (100). Results: Eighty-seven of the 100 ophthalmologists undertook pterygium surgery with no change in indications for removal, grading or anaesthesia compared to 10 years ago. Nearly half of the ophthalmologists varied their surgical technique from eight commonly used methods according to the individual patient. More than half the respondents used a swinging conjunctival flap and 29% used simple excision leaving the area bare for primary pterygia, although nearly one-quarter of the ophthalmologists added adjunctive therapies such as beta irradiation or mitomycin. For recurrent pterygia, one-third of ophthalmologists preferred adjunctive therapies, and 57% used an autoconjunctival transplant. Conclusion: There has been no consistent trend in surgical removal of pterygia with a significant number of primary pterygia still removed using bare scleral closure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to investigate the effect of high-pass filtering on TEOAE obtained from 2-month-old infants as a function of filter cut-off frequency, activity states and pass/fail status of infants. Two experiments were performed. In Experiment 1, 100 2-month-old infants (200 ears) in five activity states (asleep, awake but peaceful, sucking a pacifier, feeding, restless) were tested by use of TEOAE technology. Five different filter conditions were applied to the TEOAE responses post hoc. The filter conditions were set at 781 Hz (default setting), 1.0, 1.2, 1.4 and 1.6 kHz. Results from this experiment showed that TEOAE parameters, such as whole-wave reproducibility (WR) and signal-to-noise ratio (SNR) at 0.8 kHz and 1.6 kHz, changed as a function of the cut-off frequency. The findings suggest that the 1.6 kHz and 1.2 kHz filter conditions are optimal for WR and SNR pass/fail criteria, respectively. Although all infant recordings appeared to benefit from the filtering, infants in the noisy states seemed to benefit the most. In Experiment 2, the high-pass filtering technique was applied to 23 infants (35 ears) who apparently failed the TEOAE tests on initial screening but were subsequently awarded a pass status based on the results from a follow-up auditory brainstem response (ABR) assessment. The findings showed a significant decrease in noise contamination of the TEOAE with a corresponding significant increase in WR. With high-pass filtering at 1.6 kHz, 21/35 ears could be reclassified into the pass category.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: (1) To establish test performance measures for Transient Evoked Otoacoustic Emission testing of 6-year-old children in a school setting; (2) To investigate whether Transient Evoked Otoacoustic Emission testing provides a more accurate and effective alternative to a pure tone screening plus tympanometry protocol. Methods: Pure tone screening, tympanometry and transient evoked otoacoustic emission data were collected from 940 subjects (1880 ears), with a mean age of 6.2 years. Subjects were tested in non-sound-treated rooms within 22 schools. Receiver operating characteristics curves along with specificity, sensitivity, accuracy and efficiency values were determined for a variety of transient evoked otoacoustic emission/pure tone screening/tympanometry comparisons. Results: The Transient Evoked Otoacoustic Emission failure rate for the group was 20.3%. The failure rate for pure tone screening was found to be 8.9%, whilst 18.6% of subjects failed a protocol consisting of combined pure tone screening and tympanometry results. In essence, findings from the comparison of overall Transient Evoked Otoacoustic Emission pass/fail with overall pure tone screening pass/fail suggested that use of a modified Rhode Island Hearing Assessment Project criterion would result in a very high probability that a child with a pass result has normal hearing (true negative). However, the hit rate was only moderate. Selection of a signal-to-noise ratio (SNR) criterion set at greater than or equal to 1 dB appeared to provide the best test performance measures for the range of SNR values investigated. Test performance measures generally declined when tympanometry results were included, with the exception of lower false alarm rates and higher positive predictive values. The exclusion of low frequency data from the Transient Evoked Otoacoustic Emission SNR versus pure tone screening analysis resulted in improved performance measures. Conclusions: The present study poses several implications for the clinical implementation of Transient Evoked Otoacoustic Emission screening for entry level school children. Transient Evoked Otoacoustic Emission pass/fail criteria will require revision. The findings of the current investigation offer support to the possible replacement of pure tone screening with Transient Evoked Otoacoustic Emission testing for 6-year-old children. However, they do not suggest the replacement of the pure tone screening plus tympanometry battery. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypovitaminosis D is a candidate risk-modifying factor for a diverse range of disorders apart from rickets and osteoporosis. Based on epidemiology, and on in vitro and animal experiment, vitamin D has been linked to multiple sclerosis, certain cancers (prostate, breast and colorectal), insulin-dependent diabetes mellitus and schizophrenia. I hypothesise that low pre- and perinatal vitamin D levels imprint on the functional characteristics of various tissues throughout the body, leaving the affected individual at increased risk of developing a range of adult-onset disorders. The hypothesis draws from recent advances in our understanding of the early origin of adult disease and proposes a 'critical window' during which vitamin D levels may have a persisting impact on adult health outcomes. Methods to test the hypothesis are outlined. If correct, the hypothesis has important implications for public health. Careful attention to maternal vitamin D status could translate into diverse improvements in health outcomes for the following generation. (C) 2001 Harcourt Publishers Ltd.