318 resultados para Vertebrae
Resumo:
Study Design. Ex vivo study of the mechanical performance of cylindrical and dual-core pedicle screws after insertion, removal, and reinsertion in the same hole. Objective. To evaluate the effect of repeated use of same screw hole on the insertion torque and the retentive strength of the cylindrical and dual-core screws. Summary of Background Data. Insertion and removal of pedicle screws is sometimes necessary during surgical procedure to assess the integrity of the pilot-hole wall. However, this maneuver may compromise the implant-holding capacity. Methods. Sixty thoracolombar vertebrae (T13-L5), harvested from 10 healthy calves, were used to insert 2 different designs of pedicle screws: cylindrical (5.0-mm outer diameter) and dual-core screws (5.2-mm outer diameter). Three experimental groups were created on the basis of the number of insertions of the screws and 2 subgroups were established according to the core pedicle screw design (dual-core and cylindrical). The insertion torque was measured during initial insertion, second insertion, and third insertion. Pullout screw tests were performed using a universal testing machine to evaluate the pullout strength after initial insertion, second insertion, and third insertion. Results. Significant reductions of 38% in mean insertion torque and 30% in mean pullout strength of dual-core screw were observed between the initial insertion and the third insertion. The cylindrical screw observed significant reductions of 52.5% in mean insertion torque and 42.3% in mean pullout strength between the initial insertion and the third insertion. A reduction of mean insertion torque and pullout strength between the first insertion and the second insertion but without significance was also observed for both types of screws. Conclusion. Insertions and reinsertion of either cylindrical or dual-core pedicle screws have compromised insertion torque and pullout strength of the implants as measured by mechanical tests.
Pain and quality of life in patients undergoing radiotherapy for spinal metastatic disease treatment
Resumo:
Abstract Background Radiotherapy is an important tool in the control of pain in patients with spinal metastatic disease. We aimed to evaluate pain and of quality of life of patients with spinal metastatic disease undergoing radiotherapy with supportive treatment. Methods The study enrolled 30 patients. From January 2008 to January 2010, patients selection included those treated with a 20 Gy tumour dose in five fractions. Patients completed the visual analogue scale for pain assessment and the SF-36 questionnaire for quality of life assessment. Results The most frequent primary sites were breast, multiple myeloma, prostate and lymphoma. It was found that 14 spinal metastatic disease patients (46.66%) had restricted involvement of three or fewer vertebrae, while 16 patients (53.33%) had cases involving more than three vertebrae. The data from the visual analogue scale evaluation of pain showed that the average initial score was 5.7 points, the value 30 days after the end of radiotherapy was 4.60 points and the average value 6 months after treatment was 4.25 points. Notably, this final value was 25.43% lower than the value from the initial analysis. With regard to the quality of life evaluation, only the values for the functional capability and social aspects categories of the questionnaire showed significant improvement. Conclusion Radiotherapy with supportive treatment appears to be an important tool for the treatment of pain in patients with spinal metastatic disease.
Resumo:
Os glicocorticoides (GC) são prescritos por praticamente todas as especialidades médicas, e cerca de 0,5% da população geral do Reino Unido utiliza esses medicamentos. Com o aumento da sobrevida dos pacientes com doenças reumatológicas, a morbidade secundária ao uso dessa medicação representa um aspecto importante que deve ser considerado no manejo de nossos pacientes. As incidências de fraturas vertebrais e não vertebrais são elevadas, variando de 30%-50% em pessoas que usam GC por mais de três meses. Assim, a osteoporose e as fraturas por fragilidade devem ser prevenidas e tratadas em todos os pacientes que iniciarão ou que já estejam em uso desses esteroides. Diversas recomendações elaboradas por várias sociedades internacionais têm sido descritas na literatura, porém não há consenso entre elas. Recentemente, o Americam College of Rheumatology publicou novas recomendações, porém elas são fundamentadas na FRAX (WHO Fracture Risk Assessment Tool) para analisar o risco de cada indivíduo e, dessa maneira, não podem ser completamente utilizadas pela população brasileira. Dessa forma, a Comissão de Osteoporose e Doenças Osteometabólicas da Sociedade Brasileira de Reumatologia, em conjunto com a Associação Médica Brasileira e a Associação Brasileira de Medicina Física e Reabilitação, implementou as diretrizes brasileiras de osteoporose induzida por glicocorticoide (OPIG), baseando-se na melhor evidência científica disponível e/ou experiência de experts. DESCRIÇÃO DO MÉTODO DE COLETA DE EVIDÊNCIA: A revisão bibliográfica de artigos científicos desta diretriz foi realizada na base de dados MEDLINE. A busca de evidência partiu de cenários clínicos reais, e utilizou as seguintes palavras-chave (MeSH terms): Osteoporosis, Osteoporosis/chemically induced*= (Glucocorticoids= Adrenal Cortex Hormones, Steroids), Glucocorticoids, Glucocorticoids/administration and dosage, Glucocorticoids/therapeutic use, Glucocorticoids/adverse effects, Prednisone/adverse effects, Dose-Response Relationship, Drug, Bone Density/drug effects, Bone Density Conservation Agents/pharmacological action, Osteoporosis/ prevention&control, Calcium, Vitamin D, Vitamin D deficiency, Calcitriol, Receptors, Calcitriol; 1-hydroxycholecalciferol, Hydroxycholecalciferols, 25-Hydroxyvitamin D3 1-alpha-hydroxylase OR Steroid Hydroxylases, Prevention and Control, Spinal fractures/prevention & control, Fractures, Spontaneous, Lumbar Vertebrae/injuries, Lifestyle, Alcohol Drinking, Smoking OR tobacco use disorder, Movement, Resistance Training, Exercise Therapy, Bone density OR Bone and Bones, Dual-Energy X-Ray Absorptiometry OR Absorptiometry Photon OR DXA, Densitometry, Radiography, (Diphosphonates Alendronate OR Risedronate Pamidronate OR propanolamines OR Ibandronate OR Zoledronic acid, Teriparatide OR PTH 1-34, Men AND premenopause, pregnancy, pregnancy outcome maternal, fetus, lactation, breast-feeding, teratogens, Children (6-12 anos), adolescence (13-18 anos). GRAU DE RECOMENDAÇÃO E FORÇA DE EVIDÊNCIA: A) Estudos experimentais e observacionais de melhor consistência; B) Estudos experimentais e observacionais de menor consistência; C) Relatos de casos (estudos não controlados); D) Opinião desprovida de avaliação crítica, com base em consensos, estudos fisiológicos ou modelos animais. OBJETIVO: Estabelecer as diretrizes para a prevenção e o tratamento da OPIG.
Resumo:
OBJETIVO: Avaliamos a influência do diâmetro e do modo de preparação do orifício piloto na resistência ao arrancamento e no torque de inserção dos parafusos pediculares com diâmetro interno cônico. MÉTODOS: Ensaios mecânicos foram realizados com parafusos pediculares com alma cônica e diâmetro de 4,2mm e 5,2mm inseridos nos pedículos vertebrais lombares de suínos. O orifício piloto foi confeccionado com de broca e sondas (pontiaguda e cortante) com diferentes diâmetros. RESULTADOS: Testando o parafuso de 4,2mm a perfuração com orifício igual ou inferior ao menor diâmetro interno do parafuso, aumentou o torque e a resistência ao arrancamento. Perfurações com diferentes instrumentos apresentaram comportamento semelhante. Perfurações com sondas permitiram que orifícios confeccionados com dimensões superiores ao menor diâmetro interno do parafuso apresentassem resistência semelhante a das perfurações com dimensões iguais ao menor diâmetro interno do implante, realizadas com sondas e brocas. CONCLUSÕES: Nos de 4,2 mm o diâmetro e o modo de preparação do orifício influenciam o torque e a resistência, nos de 5,2 mm apenas o torque de inserção. Não há correlação entre força de arrancamento e torque de inserção. Nível de evidência II, Estudos terapêuticos - Investigação dos Resultados do Tratamento.
Resumo:
Hemangioblastomas of the central nervous system (CNS) are low-grade highly vascularized tumors that may be sporadic or associated with Von Hippel-Lindau disease. Extradural hemangioblastomas are uncommon and those located extra and intradurally are even rarer. This study uses an illustrative case and literature review to discuss the difficulties to consider the correct diagnosis and to select the best surgical approach. A 57 years-old white male patient presented with myelopathy and right C5 radiculopathy. The images showed a lobulated, hourglass shaped, highly enhanced extra/intradural lesion that occupied the spinal canal and widened the C4-C5 right intervertebral foramen. Total resection of the intradural lesion was achieved through a posterior approach, but the extradural part could only be partially removed. Complete improvement was observed after four months of follow-up and the residual tumor has been followed up clinically and radiologically. Even though the preoperative impression was of a spinal schwannoma, the histopathological examination revealed grade I hemangioblastoma as per WHO. Despite their rarity, current complementary exams allow considering the diagnosis of hemangioblastoma preoperatively. That is essential to a better surgical planning in view of the particular surgical features of this lesion.
Resumo:
Rationale: The excessive intake of vitamin A in the form of vitamin concentrate, supplement or vitamin-rich liver can result in hypervitaminosis A in man and animals. Although osteopathologies resulting from chronic vitamin A intoxication in cats are well characterized, no information is available concerning feline hypervitaminosis A-induced liver disease. Clinical summary: We report the first case of hepatic stellate cell lipidosis and hepatic fibrosis in a domestic cat that had been fed a diet based on raw beef liver. Radiographic examination revealed exostoses and ankylosis between vertebrae C1 and T7, compatible with deforming cervical spondylosis. Necropsy showed a slightly enlarged and light yellow to bronze liver. Microscopic and ultrastructural analyses of liver tissues revealed diffuse and severe liver fibrosis associated with hepatic stellate cell hyperplasia and hypertrophy. These cells showed immunopositive staining for α-smooth muscle actin and desmin markers. The necropsy findings of chronic liver disease coupled with osteopathology supported the diagnosis of hypervitaminosis A. Practical relevance: As in human hepatology, if there is dietary evidence to support increased intake of vitamin A, then hypervitaminosis A should be considered in the differential diagnosis of chronic liver disease in cats.
Resumo:
[EN]Red porgy is a candidate species for marine aquaculture diversification.The objective of the present study was to describe the osteological development and the occurrence of skeletal deformities in Pagrus pagrus larvae in relation to the intensification of the rearing system. Fish samples were periodically collected along the development from hatching to juveniles (95days after hatching). Osteological development and the presence of skeleton abnormalities were evaluated. X-ray studies revealed a high number of fish (Semi-intensive:38.8%; Intensive:46.5 %) with skeletal deformities. No significant interaction was found on the incidence of lordosis and fused vertebrae with the rearing tecnique. However, cranial abnormalities and kyphosis incidences were significantly higher in intensive system cultured red porgy. Also, the position of fused vertebrae in this fish was located mainly in the caudal area instead of pre-hemal area for semi-intensive system reared red porgy. Present results, suggest a relationship among feeding sequence, osteological development and deformity incidence and location in red porgy larvae
Resumo:
The present research thesis was focused on the development of new biomaterials and devices for application in regenerative medicine, particularly in the repair/regeneration of bone and osteochondral regions affected by degenerative diseases such as Osteoarthritis and Osteoporosis or serious traumas. More specifically, the work was focused on the synthesis and physico-chemical-morphological characterization of: i) a new superparamagnetic apatite phase; ii) new biomimetic superparamagnetic bone and osteochondral scaffolds; iii) new bioactive bone cements for regenerative vertebroplasty. The new bio-devices were designed to exhibit high biomimicry with hard human tissues and with functionality promoting faster tissue repair and improved texturing. In particular, recent trends in tissue regeneration indicate magnetism as a new tool to stimulate cells towards tissue formation and organization; in this perspective a new superparamagnetic apatite was synthesized by doping apatite lattice with di-and trivalent iron ions during synthesis. This finding was the pin to synthesize newly conceived superparamagnetic bone and osteochondral scaffolds by reproducing in laboratory the biological processes yielding the formation of new bone, i.e. the self-assembly/organization of collagen fibrils and heterogeneous nucleation of nanosized, ionically substituted apatite mimicking the mineral part of bone. The new scaffolds can be magnetically switched on/off and function as workstations guiding fast tissue regeneration by minimally invasive and more efficient approaches. Moreover, in the view of specific treatments for patients affected by osteoporosis or traumas involving vertebrae weakening or fracture, the present work was also dedicated to the development of new self-setting injectable pastes based on strontium-substituted calcium phosphates, able to harden in vivo and transform into strontium-substituted hydroxyapatite. The addition of strontium may provide an anti-osteoporotic effect, aiding to restore the physiologic bone turnover. The ceramic-based paste was also added with bio-polymers, able to be progressively resorbed thus creating additional porosity in the cement body that favour cell colonization and osseointegration.
Resumo:
In the last decade, the mechanical characterization of bone segments has been seen as a fundamental key to understanding how the distribution of physiological loads works on the bone in everyday life, and the resulting structural deformations. Therefore, characterization allows to obtain the main load directions and, consequently, to observe the structural lamellae of the bone disposal, in order to recreate a prosthesis using artificial materials that behave naturally. This thesis will expose a modular system which provides the mechanical characterization of bone in vitro segment, with particular attention to vertebrae, as the current object of study and research in the lab where I did my thesis work. The system will be able to acquire and process all the appropriately conditioned signals of interest for the test, through dedicated hardware and software architecture, with high speed and high reliability. The aim of my thesis is to create a system that can be used as a versatile tool for experimentation and innovation for future tests of the mechanical characterization of biological components, allowing a quantitative and qualitative assessment of the deformation in analysis, regardless of anatomical regions of interest.
Resumo:
As a large and long-lived species with high economic value, restricted spawning areas and short spawning periods, the Atlantic bluefin tuna (BFT; Thunnus thynnus) is particularly susceptible to over-exploitation. Although BFT have been targeted by fisheries in the Mediterranean Sea for thousands of years, it has only been in these last decades that the exploitation rate has reached far beyond sustainable levels. An understanding of the population structure, spatial dynamics, exploitation rates and the environmental variables that affect BFT is crucial for the conservation of the species. The aims of this PhD project were 1) to assess the accuracy of larval identification methods, 2) determine the genetic structure of modern BFT populations, 3) assess the self-recruitment rate in the Gulf of Mexico and Mediterranean spawning areas, 4) estimate the immigration rate of BFT to feeding aggregations from the various spawning areas, and 5) develop tools capable of investigating the temporal stability of population structuring in the Mediterranean Sea. Several weaknesses in modern morphology-based taxonomy including demographic decline of expert taxonomists, flawed identification keys, reluctance of the taxonomic community to embrace advances in digital communications and a general scarcity of modern user-friendly materials are reviewed. Barcoding of scombrid larvae revealed important differences in the accuracy of the taxonomic identifications carried out by different ichthyoplanktologists following morphology-based methods. Using a Genotyping-by-Sequencing a panel of 95 SNPs was developed and used to characterize the population structuring of BFT and composition of adult feeding aggregations. Using novel molecular techniques, DNA was extracted from bluefin tuna vertebrae excavated from late iron age, ancient roman settlements Byzantine-era Constantinople and a 20th century collection. A second panel of 96 SNPs was developed to genotype historical and modern samples in order to elucidate changes in population structuring and allele frequencies of loci associated with selective traits.
Resumo:
ZusammenfassungrnAlle bekannten Exemplare der Amphibien-Gruppe Microsauria des mitteleuropäischen Rotliegend wurden untersucht sowie – für die kladistische Untersuchung – ihre nächsten Verwandten. Im Saar-Nahe-Becken sind vier Arten aus zwei Microsauria-Gattungen nachzuweisen: Batropetes niederkirchensis n. sp., Batropetes palatinus n. sp., Batropetes appelensis n. sp. und Altenglanerpeton schroederi n. sp.. Aus dem Döhlen-Becken bei Dresden stammt Batropetes fritschi.rnDie Rekonstruktionen legen nahe, dass die in Seeablagerungen gefundenen Batropetes-Arten kleine, terrestrisch lebende Microsaurier waren, die sich von Insekten oder deren Larven ernährten. Ihre mittlere Gesamtlänge beträgt fast 8 cm, ihr Rumpf ist auffallend kurz mit je nach Art 17 oder 19 Präsakralwirbeln. Sie besitzen große von Wülsten umgebene Augenöffnungen, ein großes Pinealforamen, drei längs angeordnete Grübchen auf den Frontalia, dreispitzige Zähne, einen zahnlosen Gaumen und vier kurze kräftige Extremitäten. Becken- und Schultergürtel sind komplett verknöchert, außer den bei Batropetes appelensis und Batropetes fritschi knorpeligen Coracoid-Anteilen. Die Batropetes-Arten unterscheiden sich bezüglich Form, Proportionen bzw. Verknöcherungsgrad einiger Knochen im cranialen und postcranialen Skelett. rnDie kladistischen Untersuchungen ergeben für die Arten der monophyletische Gattung Batropetes, dass Batropetes appelensis den übrigen Arten gegenübersteht und Batropetes palatinus mit Batropetes fritschi eine Schwestergruppe zu Batropetes niederkirchensis bildet. Mit den etwas jüngeren texanischen Gattungen Carrolla und Quasicaecilia bildet Batropetes die monophyletische Familie Brachystelechidae. rnAltenglanerpeton schroederi, nur durch ein schlecht erhaltenes Exemplar überliefert, besitzt einen massiv gebauten Schädel, kaum länger als breit mit annähernd dreieckigem Umriss, ohne Anzeichen für Seitenlinien, mit kleiner rundlicher Orbita, sehr breiter Interorbitalregion und bis weit vor die Orbita reichendem Jugale. Sein langer Rumpf umfasst mindestens 30 lepospondyle Präsakralwirbel. Wegen der unvollkommenen Entwicklung der Gliedmaßen kann diese Art nicht auf vier Beinen gelaufen sein und lebte möglicherweise in der Laubschicht wühlend oder in Sümpfen. Altenglanerpeton ist keiner bestimmten Microsauria-Familie zuzuordnen und steht den Pantylidae, Gymnarthridae, Goniorhynchidae und Ostodolepidae am nächsten, wobei zu letzteren die meisten morphologischen Ähnlichkeiten bestehen.rnAußerdem sind mit isolierten Einzelknochen, insbesondere Wirbeln, Microsauria und andere Gruppen lepospondyler Amphibien ohne Bestimmung der Gattung und Art aus wenigen stratigraphischen Niveaus des Saar-Nahe-Beckens überliefert. rn
Resumo:
The spinal column performs important functions in the body, including the support of the entire weight of the human body, the ability to orientate the head in space, bending, flexing and rotating the body. Diseases affecting the spine are manifold: the most frequent is scoliosis, which often affects the female population. It is often treated surgically with a very high percentage of failures. The aim of the thesis is to study the role of instrumentation in mechanical failures encountered 12 months after surgery in the treatment of scoliosis. For the purposes of the study, we analyzed specific biomechanical parameters. The pelvic angles determine the position of the pelvis, while the imbalance parameters the structure of the body. We infer other parameters by analyzing the characteristics of the implanted instrumentation. Initially, the anatomy is described of the spine and vertebrae, the equipment used and the possible failures that may occur after surgery. Subsequently, the materials and methods used for the analysis of the above-mentioned parameters for the 61 patients are reported. All data are obtained by the observation of pre and post-operative x-rays with a special program, by reading reports from operators and by medical records. In the fourth chapter, we report the results: the overall failure rate is 60.9%; the types of failures that occurred are rupture of bars and rupture of bars simultaneously to PJK. The most influential parameters on results of the progress of the surgery are the type of material used and the BMI. It is estimated a high percentage of failures in patients treated with implants of cobalt chromium alloys (90.0%). According to the results obtained, it is possible to understand the aspects that in the future should be studied, in order to find a solution to the most frequent surgical failures.
Prevalence of findings compatible with carotid artery calcifications on dental panoramic radiographs
Resumo:
Cerebrovascular accidents are responsible for killing or disabling more than half a million Americans every year. They are the third leading cause of death in this country. In Germany, the annual stroke incidence reaches 182 cases per 100,000 inhabitants. Stroke there is the fourth leading cause of death. There is a need of finding cost-effective means of decreasing stroke mortality and morbidity. Instruments for early diagnosis are of great humanitarian and economic importance. All possible clinical findings should be taken into account. It is not the demand of this study to present the panoramic radiograph as a screening test method for early diagnosis of atherosclerosis. The aim is to show the potential of this radiograph used in everyday clinical dental practice by the prevalence of radiopaque findings in the carotid region. This study included panoramic dental radiographs of 2,557 patients older than 30 years of age. Fifty-nine percent of the patients were women and 41% were men. The radiographs were adjudged for signs compatible with carotid arterial calcifications appearing as a radiopaque nodular mass adjacent to the cervical vertebrae at or below the intervertebral space C3-4. Of all these radiographs, 4.8% showed radiopaque findings compatible with atherosclerotic lesions. The proportion of women reached 64.8% and that of men reached 35.2%. In accordance to recent literature, the results of this study show that about 5% of the patients show radiological findings compatible with carotid arterial calcifications. Some of these patients at risk for a cerebrovascular accident may be identified in the dentist's office by appropriate review of the panoramic dental radiograph. The suspicion of carotid artery calcifications demands an impetuous referral to an appropriate practitioner who can assist in the control of risk factors and if necessary arrange surgical removal of the carotid arterial plaque. So, the dentist should be aware of this problem and able to make a contribution to stroke prevention.
Resumo:
Robust and accurate identification of intervertebral discs from low resolution, sparse MRI scans is essential for the automated scan planning of the MRI spine scan. This paper presents a graphical model based solution for the detection of both the positions and orientations of intervertebral discs from low resolution, sparse MRI scans. Compared with the existing graphical model based methods, the proposed method does not need a training process using training data and it also has the capability to automatically determine the number of vertebrae visible in the image. Experiments on 25 low resolution, sparse spine MRI data sets verified its performance.
Resumo:
Purpose Accurate three-dimensional (3D) models of lumbar vertebrae can enable image-based 3D kinematic analysis. The common approach to derive 3D models is by direct segmentation of CT or MRI datasets. However, these have the disadvantages that they are expensive, timeconsuming and/or induce high-radiation doses to the patient. In this study, we present a technique to automatically reconstruct a scaled 3D lumbar vertebral model from a single two-dimensional (2D) lateral fluoroscopic image. Methods Our technique is based on a hybrid 2D/3D deformable registration strategy combining a landmark-to-ray registration with a statistical shape model-based 2D/3D reconstruction scheme. Fig. 1 shows different stages of the reconstruction process. Four cadaveric lumbar spine segments (total twelve lumbar vertebrae) were used to validate the technique. To evaluate the reconstruction accuracy, the surface models reconstructed from the lateral fluoroscopic images were compared to the associated ground truth data derived from a 3D CT-scan reconstruction technique. For each case, a surface-based matching was first used to recover the scale and the rigid transformation between the reconstructed surface model Results Our technique could successfully reconstruct 3D surface models of all twelve vertebrae. After recovering the scale and the rigid transformation between the reconstructed surface models and the ground truth models, the average error of the 2D/3D surface model reconstruction over the twelve lumbar vertebrae was found to be 1.0 mm. The errors of reconstructing surface models of all twelve vertebrae are shown in Fig. 2. It was found that the mean errors of the reconstructed surface models in comparison to their associated ground truths after iterative scaled rigid registrations ranged from 0.7 mm to 1.3 mm and the rootmean squared (RMS) errors ranged from 1.0 mm to 1.7 mm. The average mean reconstruction error was found to be 1.0 mm. Conclusion An accurate, scaled 3D reconstruction of the lumbar vertebra can be obtained from a single lateral fluoroscopic image using a statistical shape model based 2D/3D reconstruction technique. Future work will focus on applying the reconstructed model for 3D kinematic analysis of lumbar vertebrae, an extension of our previously-reported imagebased kinematic analysis. The developed method also has potential applications in surgical planning and navigation.