951 resultados para Ventilated stone veneer
Resumo:
This paper presents the results of performance monitoring under real winter weather conditions, controlled laboratory testing and computational fluid dynamics (CFD) analysis of a wall mounted ventilation air inlet heat convector. For real winter weather monitoring, the wall-mounted convector was installed in a laboratory room of the Engineering Building of the School of Construction Management and Engineering. Air and hot water temperatures and air speeds were measured at the entrance to the convector and in the room. The hot water temperature was controlled at 40, 60 and 80 °C. The monitoring results were later used as boundary conditions for a CFD simulation to investigate the air movement in the room. Controlled laboratory testing was conducted in laboratories at the University of Reading, UK and at Wetterstad Consultancy, Sweden. The results of the performance investigation showed that the system contributed greatly to the room heating, particularly at a water temperature of 80 °C. Also adequate fresh air was supplied to the room. Such a system is able to provide an energy efficient method of eliminating problems associated with cold winter draughts.
Resumo:
Until recently, there has been little investigation concerning the poor indoor air quality (IAQ) in classrooms. Despite the evidence that the educational building systems in many of the UK institutions have significant defects that may degrade IAQ, systematic assessments of IAQ measurements has been rarely undertaken. When undertaking IAQ measurement, there is a difficult task of representing and characterizing the environment parameters. Although technologies exist to measure these parameters, direct measurements especially in a naturally ventilated spaces are often difficult. This paper presents a methodology for developing a method to characterize indoor environment flow parameters as well as the Carbon Dioxide (CO2) concentrations. Thus, CO2 concentration level can be influenced by the differences in the selection of sampling points and heights. However, because this research focuses on natural ventilation in classrooms, air exchange is provided mainly by air infiltration. It is hoped that the methodology developed and evaluated in this research can effectively simplify the process of estimating the parameters for a systematic assessment of IAQ measurements in a naturally ventilated classrooms.
Resumo:
The nexus of teaching, administration and research activities engaged in by academic staff in higher education means that each individual plays a multitude of roles in relation to colleagues, producing inevitable tensions. One role relationship that epitomizes this extraordinary juggling task is that of doctoral supervisor/supervisee, when both are academic staff in the same institution. The last 10 years has seen an upsurge of research interest in doctoral research students, and government and funding bodies have imposed ever more stringent requirements on supervisors. However, staff pairings have been ignored in this literature and research. This article reports on an exploration that seeks to redress this omission by giving voice to the participants (colleague supervisor or research student), allowing them to articulate constructs about what may be unique in the interaction, thus highlighting factors that support or impede success in the enterprise.
Resumo:
The nexus of teaching, administration and research activities engaged in by academic staff in higher education means that each individual plays a multitude of roles in relation to colleagues, producing inevitable tensions. One role relationship that epitomizes this extraordinary juggling task is that of doctoral supervisor/supervisee, when both are academic staff in the same institution. The last 10 years has seen an upsurge of research interest in doctoral research students, and government and funding bodies have imposed ever more stringent requirements on supervisors. However, staff pairings have been ignored in this literature and research. This article reports on an exploration that seeks to redress this omission by giving voice to the participants (colleague supervisor or research student), allowing them to articulate constructs about what may be unique in the interaction, thus highlighting factors that support or impede success in the enterprise.
Resumo:
Commercial mango production in Ghana is a relatively young industry faced with several pest problems including the mango stone weevil, Sternochetus mangiferae (F.). There is an urgent need to control this and other pests to facilitate access to the international export market for fresh mango fruits. A literature survey identifies stone weevil control tactics in the areas of host plant resistance, administrative and legislative controls, use of pesticides, biological control, cultural control and quarantine and phytosanitary measures that have been developed in other mango-producing areas. We assess these pest management approaches for their relevance to Ghana and West Africa, with emphasis on the research required for their appropriate, effective and sustainable use in the systems of mango production of the West African sub-region. The importance of processing and value addition technologies, as a means of circumventing the quarantine hurdles of S. mangiferae, is highlighted.
Resumo:
Systematic natural ventilation effects on measured temperatures within a standard large wooden thermometer screen are investigated under summer conditions, using well-calibrated platinum resistance thermometers. Under low ventilation (2mwind speed u2 < 1.1 m s−1), the screen slightly underestimates daytime air temperature but overestimates air temperature nocturnally by 0.2◦C. The screen’s lag time L lengthens with decreasing wind speed, following an inverse power law relationship between L and u2. For u2 > 2 m s−1, L ∼ 2.5 min, increasing, when calm, to at least 15 min. Spectral response properties of the screen to air temperature fluctuations vary with wind speed because of the lag changes. Ventilation effects are particularly apparent at the higher (>25◦C) temperatures, both through the lag effect and from solar heating. For sites where wind speed decreases with increasing daytime temperature, thermometer screen temperatures may consequently show larger uncertainties at the higher temperatures. Under strong direct beam solar radiation (>850W m−2) the radiation effect is likely to be <0.4◦C. Copyright c 2011 RoyalMeteorological Society
Resumo:
There is a tendency to reduce ventilation rates and natural or hybrid ventilation systems to ensure the conservation of energy in school buildings. However, high indoor pollutant concentration, due to natural or hybrid ventilation systems may have a significant adverse impact on the health and academic performance of pupils and students. Reviewed evidence shows that this can be detrimental to health and wellbeing in schools because of the learner density within a small area, eventually indicating that CO2 concentrations can rise to very high levels (about 4000 ppm) in classrooms during occupancy periods. In South Africa’s naturally ventilated classrooms, it is not clear whether the environmental conditions are conducive for learning. In addition, natural ventilation will be minimized given the fact that in cold, wet or windy weather, doors and windows will commonly remain closed. Evidence from literature based studies indicates that the significance of ventilation techniques is not understood satisfactorily and additional information concerning naturally ventilated schools has to be provided for better design and policy formulation. To develop a thorough understanding of the environments in classrooms, many other parameters have to be considered as well, such as outdoor air quality, CO2 concentrations, temperature and relative humidity and safety issues that may be important drawbacks for naturally ventilated schools. The aim of this paper is to develop a conceptual understanding of methods that can be implemented to assess the effectiveness of naturally ventilated classrooms in Gauteng, South Africa. A theoretical concept with an embedded practical methodology have been proposed for the research programme to investigate the relationship between ventilation rates and learning in schools in Gauteng , a province in South Africa. It is important that existing and future school buildings must include adequate outdoor ventilation, control of moisture, and avoidance of indoor exposures to microbiologic and chemical substances considered likely to have adverse effects in South Africa. Adequate ventilation in classrooms is necessary to reduce and/or eradicate the transmission of indoor pollutants.