980 resultados para VIDEO-ASSISTED THORACIC SURGERY
Resumo:
Background: Thaumatin is a protein originally isolated from an African fruit (the "katemfe"), but various thaumatin-like proteins have been found in apples, grapes, kiwis and olives, etc. Thaumatin has natural sweetening properties and is about 2000 to 3000 times more potent than sucrose. It is therefore used in the food industry, particularly in the processing of low-calories sweeteners. Recently, thaumatin-like proteins have been described as a new family of allergens. Methods: We report the case of a 44-year-old woman occupationally exposed to thaumatin, who developed an allergy to it. The first symptom was an urticaria, which she presented two years after the factory she was working in (a sweeteners manufacturer), started to use thaumatin. Later on, she perceived an acute episode of a sensation of lump in the throat, persisting mild dyspnea, dysphonia and cough. Despite normal peak flow values and a normal chest examination, her general practitioner treated her with local corticoids and systemic antihistaminic drugs, which improved the symptoms. As occupational physicians, we were asked about the likelihood of an occupational disease. We visited her working place, and assessed the exposure to thaumatin. We concluded that the probability for a delayed asthma related to a thaumatin exposure was high, despite the lack of an exposure test. Results: The case was submitted to the insurance company as an occupational disease, and was accepted as such. It was therefore decided not to perform the exposure test, given the absence of true benefit for the patient, who was advised to switch job, and to avoid any exposure to thaumatin in the future. A few months later, the symptoms had completely disappeared. Conclusion: Some molecules only used in specific industry sectors, can cause health problems, such as allergy, but also toxic impairments, etc. The occupational physician, trained to find out which products and identify which molecules are involved, can contribute to the diagnosis, and help make possible a safe return to work for the patient.
Resumo:
BACKGROUND: Surgical correction of complete atrio-ventricular septal defect (AVSD) achieves satisfactory results with low morbidity and mortality, but may require reoperation. Our recent operative results at mid-term were followed-up. METHODS: From June 2000 to December 2007, 81 patients (Down syndrome; n=60), median age 4.0 months (range 0.7-118.6) and weight 4.7kg (range 2.2-33), underwent complete AVSD correction. Patch closure for the ventricular septal defect (VSD; n=69) and atrial septal defect (ASD; n=42) was performed with left atrio-ventricular valve (LAVV) cleft closure (n=76) and right atrio-ventricular valve (RAVV) repair (n=57). Mortality, morbidity, and indications for reoperation were retrospectively studied; the end point 'time to reoperation' was analyzed using Kaplan-Meier curves. Follow-up was complete except in two patients and spanned a median of 28 months (range 0.4-6.1 years). RESULTS: In-hospital mortality was 3.7% (n=3) and one late death occurred. Reoperation was required in 7/79 patients (8.9%) for LAVV insufficiency (n=4), for a residual ASD (n=1), for right atrio-ventricular valve insufficiency (n=1), and for subaortic stenosis (n=1). At last follow-up, no or only mild LAVV and RAVV insufficiency was present in 81.3% and 92.1% of patients, respectively, and 2/3 of patients were medication-free. Risk factors for reoperation were younger age (<3 months; p=0.001) and lower weight (<4kg; p=0.003), and a trend towards less and later reoperations in Down syndrome (p<0.2). CONCLUSIONS: Surgical correction of AVSD can be achieved with low mortality and need for reoperation, regardless of Down syndrome or not. Immediate postoperative moderate or more residual atrio-ventricular valve insufficiency will eventually require a reoperation, and could be anticipated in patients younger than 3 months and weighing <4kg.
Resumo:
OBJECTIVES: The presence of intravascular foreign bodies is underreported in the literature and is more commonly encountered in clinical practice. We report on a case where an attempt to position a carotid stent resulted in misdeployment of the stent in the femoral artery and its surgical removal. METHODS: A 63-year-old patient admitted to hospital for cerebral stroke underwent thrombolysis for occlusive dissection of right carotid artery and was transferred to our hospital for additional thrombo-aspiration and carotid stenting. RESULTS: The carotid stent was misdeployed incompletely in the femoral artery and had to be removed surgically. CONCLUSIONS: Appropriate knowledge of intravascular migration and deployment failure management should be considered as important as the optimal device deployment.
Resumo:
Our experience with the Sapien trans-apical aortic valve (Edwards Lifesciences Inc., Irvine, CA, USA) has been straightforward without per-procedural mortality except in 1/16 consecutive cases who developed non-apical haemorrhage early after valve implantation. We describe the case of an 84-year-old female carrying a very high operative risk (logistic EuroScore of 44%), who underwent a trans-apical stent-valve implantation for severe and symptomatic aortic valve stenosis (23 mm). Due to massive blood loss, an emergency sternotomy and cannulation for cardiopulmonary bypass resuscitation were necessary to treat (without success) an unusual and unexpected subaortic left ventricular free-wall rupture that occurred few minutes after the stent-valve positioning and implantation. To the best of our knowledge, this is the first described case of a left ventricular free-wall rupture occurring after an otherwise non-complicated standard catheter-based aortic valve replacement.
Resumo:
OBJECTIVES: Assess the benefit of temporary caval stenting for remote venous drainage during cardiopulmonary bypass (CPB). METHODS: Temporary caval stenting was realized in bovine experiments (65+/-6 kg) by the means of self-expanding (18F for insertion, 36F in situ) venous cannulas (Smartcanula LLC, Lausanne, Switzerland) with various lengths: 43 cm, 53 cm, 63 cm vs. a standard 28F wire armed cannula in trans-jugular fashion. Maximal blood flows were assessed for 20, 25 and 30 mmHg of driving pressure with a motorized table height adjustment system. In addition, the inferior caval diameters (just above its bifurcation) were measured in real time with intra-vascular ultrasound (IVUS). RESULTS: Venous drainage (flow in l/min) at 20 mmHg, 25 mmHg, and 30 mmHg drainage load was 3.5+/-0.5, 3.7+/-0.7 and 4.0+/-0.6 for the 28F standard vs. 4.1+/-0.7, 4.0+/-1.3 and 3.9+/-1.1 for the 36F smart 43 cm, vs. 5.0+/-0.7, 5.3+/-1.3 and 5.4+/-1.4 for the 36F smart 53 cm, vs. 5.2+/-0.5*, 5.6+/-1.1* and 5.8+/-1.0* for the 36F smart 63 cm. The inferior vena caval diameters at 30 mmHg were 13.5+/-4.8 mm for 28F standard, 11.1+/-3.6 for 36F smart 43 cm, 11.3+/-3.2 for 36F 53 cm, and 17.0+/-0.1* for 36F 63 cm (*P<0.05 for 28F standard vs. 36F smart 63 cm long) CONCLUSIONS: The 43 cm self-expanding 36F smartcanula outperforms the 28F standard wire armed cannula at low drainage pressures and without augmentation. Temporary caval stenting with long self-expanding venous cannulas provides even better drainage (+51%).
Resumo:
BACKGROUND: In late-diagnosed transposition of the great arteries (TGA), the left ventricle (LV) involutes as it pumps against low resistance and needs retraining by applying a pulmonary artery band (PAB) in preparation for an arterial switch operation. We report our experience with a telemetrically adaptable band compared with classic banding. METHODS: Ten patients underwent retraining of the LV, 4 patients with an adaptable band and progressive weekly tightening of the band (group 1) and 6 patients with a traditional band (group 2). RESULTS: Mean weight and age at pulmonary band placement was 5.8 ± 2.36 kg and 11.7 ± 11.1 months for group 1 and 5.0 ± 2.3 kg and 6.4 ± 7.6 months for group 2. Time between palliation and switch procedure was 4.2 months in both groups. Group 1 showed an initial mean pulmonary gradient of 25.5 ± 4.43 mm Hg with a 5% closure of the device. The mean gradient increased with progressive closure to 63.5 ± 9.8 mm Hg at the time of the arterial switch operation. There were no reinterventions or deaths in this group. In group 2, the mean pulmonary gradient increased with growth from 49 ± 21.4 mm Hg to 68.4 ± 7.86 mm Hg at the time of the switch procedure. However, 4 of these patients required reoperations during retraining: 2 needed 1 reoperation and 2 needed 2 reoperations. Two patients died-1 after banding and 1 after the switch operation. CONCLUSIONS: Retraining of the LV by the adaptable device allows precise control of the tightening, avoids repetitive operations, and diminishes morbidity.
Resumo:
OBJECTIVES: Residual mitral regurgitation after valve repair worsens patients' clinical outcome. Postimplant adjustable mitral rings potentially address this issue, allowing the reshaping of the annulus on the beating heart under echocardiography control. We developed an original mitral ring allowing valve geometry remodelling after the implantation and designed an animal study to assess device effectiveness in correcting residual mitral regurgitation. METHODS: The device consists of two concentric rings: one internal and flexible, sutured to the mitral annulus and a second external and rigid. A third conic element slides between the two rings, modifying the shape of the flexible ring. This sliding element is remotely activated with a rotating tool. Animal model: in adult swine, under cardio pulmonary bypass and cardiac arrest, we shortened the primary chordae of P2 segment to reproduce Type III regurgitation and implanted the active ring. We used intracardiac ultrasound to assess mitral regurgitation and the efficacy of the active ring to correct it. RESULTS: Severe mitral regurgitation (3+ and 4+) was induced in eight animals, 54 ± 6 kg in weight. Vena contracta width decreased from 0.8 ± 0.2 to 0.1 cm; proximal isovelocity surface area radius decreased from 0.8 ± 0.2 to 0.1 cm and effective regurgitant orifice area decreased from 0.50 ± 0.1 to 0.1 ± 0.1 cm(2). Six animals had a reversal of systolic pulmonary flow that normalized following the activation of the device. All corrections were reversible. CONCLUSIONS: Postimplant adjustable mitral ring corrects severe mitral regurgitation through the reversible modification of the annulus geometry on the beating heart. It addresses the frequent and morbid issue of recurrent mitral valve regurgitation.
Resumo:
The distribution of free and liposomal doxorubicin (Liporubicin) administered by intravenous injection (IV) or isolated lung perfusion (ILP) was compared in normal and tumor tissues of sarcoma bearing rodent lungs. A single sarcomatous tumor was generated in the left lung of 35 Fischer rats, followed 10 days later by left-sided ILP (n=20) or IV drug administration (n=12), using 100 microg and 400 microg free or liposomal doxorubicin, respectively. The tumor and lung tissue drug concentration was measured by HPLC. Free doxorubicin administered by ILP resulted in a three-fold (100 microg) and 10-fold (400 microg) increase of the drug concentration in the tumor and normal lung tissue compared to IV administration. In contrast, ILP with Liporubicin resulted in a similar drug uptake in the tumor and lung tissue compared to IV injection. For both drug formulations and dosages, ILP resulted in a higher tumor to lung tissue drug ratio but also in a higher spatial heterogeneity of drug distribution within the lung compared to IV administration. ILP resulted in a higher tumor to lung tissue drug ratio and in a more heterogeneous drug distribution within the lung compared to IV drug administration.
Resumo:
Introduction: Isocyanates are sensitizing chemicals used in various industries such as polyurethane foam production or paint-related purposes. Acting as haptens recognized by T-lymphocytes, they can cause allergic asthma and rarely hypersensitivity pneumonitis (HP). We aim to present a case report of acute HP due to hexamethylene diisocyanate (HDI) in a paint quality controller, a profession not generally considered at a high risk for work-related Isocyanates exposure. Case report: A 30-yr-old otherwise healthy female, light smoker working as a paint quality controller developed shortness of breath, malaise, sweating and chills at workplace six hours after handling a HDI-based hardener. Upon admission to emergency department, symptoms had progressed to severe respiratory failure. HR computer tomography (HRCT) showed bilateral ground-glass attenuation without pleural effusion. Rapid clinical and radiological improvement occurred under facial oxygen supply and systemic steroid therapy. Occupational medicine investigations revealed regular handling of HDI using latex gloves without respiratory protection. Assessment at workplace showed insufficient air renewal (1.5 times per hour), inadequate local aspiration and HDI exposure at levels of 1-4.25 ppb/m3 (Swiss Occupation Exposure Limit 5 ppb/m3). Biological monitoring after identical work procedure executed by a co-worker showed HDI exposure (5.1 micrograms hexamethylene diamine/g creatinine). Resumption of work was disadvised because of the life-threatening event. Discussion: The diagnosis of occupational HP is highly supported by classical findings on imagery and typical symptoms occurring within approved latency interval, associated with rapid clinical improvement. Although neither broncho-alveolar lavage nor specific IgG diagnosis (en route) were performed during the acute episode, various blood tests managed to rule out evidence of an infection or autoimmune disease. Other causes of HP seem unlikely as the patient did not have any recurrence of symptoms since absence from work. Workplace evaluation provided significant information on HDI exposure and allowed substantial recommendations to diminish Isocyanate exposure for the 20 still healthy laboratory co-workers. Although the entryways (air or skin) and precise mechanism of toxicity remain unclear, the present case clearly shows that Isocyanates may trigger acute HP in susceptible workers in a profession not generally considered at a high risk.