975 resultados para Ultrasonic Attenuation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the influence of variations in the working angle of the piezoelectric ultrasonic scaler (PUS) on root surfaces. Material and methods Fifty-five uniradicular bovine teeth were used, of which 25 teeth were used for the analysis of the roughness and root wear, while the remaining 30 teeth were used for the analysis of morphology (MRS) and the attachment of blood components (ABC). The teeth were randomly divided into five groups according to the type of treatment (G1-G5: piezoelectric ultrasonic scaler; G6: manual curette) and to the PUS working angle applied (G1: 0°; G2: 30°; G3: 45°; G4: 60°; G5: 90°). For statistical analysis, the data describing the MRS and ABC were analysed by the Kruskal–Wallis and Dunn's tests, and the data describing the roughness and tooth wear were analysed by anova and Tukey's tests at the significance level of 5%. Results Manual curette (MC) promoted a smoother root surface than the application of the PUS. The PUS used at the angles of 30° and 45° resulted in a high level of ABC that was comparable to that obtained by MC. Additionally, the group in which the PUS was applied at an angle of 45° exhibited less tooth wear than the other groups. Conclusions Changes in the working angle of the PUS influenced the characteristics of root surfaces after instrumentation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of ultrasound and osmotic dehydration pretreatments on papaya drying kinetics was investigated. The ultrasound pretreatment was carried out in an ultrasonic bath at 30 A degrees C. The osmotic pretreatment in sucrose solution was carried out in an incubator at 34 A degrees C and agitation of 80 rpm for 210 min. The drying process was conducted in a fixed bed dryer at 70 A degrees C. Experimental data were fitted successfully using the Page model for dried fresh and pretreated fruits, with coefficient of determination greater than 0.9992 and average relative error lower that 14.4 %. The diffusional model was used to describe the moisture transfer, and the effective water diffusivity was identified in the order of 10(-9) m(2) s(-1). It was found that drying rates of osmosed fruits were the lowest due to the presence of infused solutes, while the ultrasound pretreatment contributed to faster drying rates. Evaluation of the dried fruit was performed by means of total carotenoids retention. Ultrasound treatments in distilled water prior to air-drying gave rise to dried papayas with retention of carotenoids in the range 30.4-39.8 % and the ultrasonic-assisted osmotic dehydration of papayas showed carotenoids retention values up to 64.9 %, whereas the dried fruit without pretreatment showed carotenoids retention lower than 24 %.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research aims to present a new method to get real attenuation of hearing protection devices, with good reproducibility and a small standard deviation, without relying on skills and cooperation individual. Thus the authors performed tests in 10 individuals without protection and after with two kinds of ear protections (ear plug and ear muffs), to get the threshold limit value in each of the 3 stages. For this, the research used an electrophysical exam, normally used in speech therapy, named ASSR (auditory steady-state response). The principle of this exam is put on individual’s head 3 electrodes, to capture electrical signs directly in auditory nerve. In summary, the authors presented the final results. The method proposed by ANSI (American National Standards Institute) indicated an attenuation of 27.6 dB for ear plugs, while the value found in this work was 16 dB; and for ear muffs, the ANSI method indicated 29.8 dB while the value found here was 28.5 dB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Product miniaturization for applications in fields such as biotechnology, medical devices, aerospace, optics and communications has made the advancement of micromachining techniques essential. Machining of hard and brittle materials such as ceramics, glass and silicon is a formidable task. Rotary ultrasonic machining (RUM) is capable of machining these materials. RUM is a hybrid machining process which combines the mechanism of material removal of conventional grinding and ultrasonic machining. Downscaling of RUM for micro scale machining is essential to generate miniature features or parts from hard and brittle materials. The goal of this thesis is to conduct a feasibility study and to develop a knowledge base for micro rotary ultrasonic machining (MRUM). Positive outcome of the feasibility study led to a comprehensive investigation on the effect of process parameters. The effect of spindle speed, grit size, vibration amplitude, tool geometry, static load and coolant on the material removal rate (MRR) of MRUM was studied. In general, MRR was found to increase with increase in spindle speed, vibration amplitude and static load. MRR was also noted to depend upon the abrasive grit size and tool geometry. The behavior of the cutting forces was modeled using time series analysis. Being a vibration assisted machining process, heat generation in MRUM is low which is essential for bone machining. Capability of MRUM process for machining bone tissue was investigated. Finally, to estimate the MRR a predictive model was proposed. The experimental and the theoretical results exhibited a matching trend.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ruminal methanogens reduce carbon dioxide to methane (CH 4 ), thereby preventing hydrogen use by bacteria for VFA synthesis resulting in a 2 to 12% loss in feed gross energy. Methane is a greenhouse gas that contributes to global warming. The objectives of this work were to determine: (1) the extent to which ruminal cultures acquire resistance to a nitrofuranyl derivative of para-aminobenzoate (NFP) and an extract from the plant Yucca shidigera (Yucca); (2) the effect of distillers dried grains plus solubles (DDGS) on ruminal CH4 production; (3) the effect of brome hay-based diets, corn-based diets, and in vivo 2-bromoethansulfonate treatment on ruminal methane (CH4 ) production; and (4) the effect of the above treatments on the methanogen population. Ruminal cultures treated with NFP for 90 d maintained a diminished capacity to generate CH4 , but cultures became resistant to the inhibitory effects of Yucca treatment within 10 d. Both treatments decreased (P < 0.01) the relative abundance of total Archaea and the order Methanomicrobiales, but Yucca treatment increased (P < 0.01) the relative abundance of the order Methanobacteriales. The replacement of brome hay and corn with DDGS in lamb diets decreased (P < 0.01) and increased (P < 0.05), respectively, the amount of CH4 produced per unit of digested DM. The substitution of DDGS for brome hay increased (P < 0.01) the relative abundance of the order Methanomicrobiales. The replacement of brome hay with corn decreased (P < 0.05) the amount of CH4 produced per unit of digested DM, and also decreased (P < 0.05) the relative abundance of both Archaea and the order Methanomicrobiales. However, the abundance of the order Methanobacteriales increased (P < 0.05) as corn replaced brome hay. Intraruminal administration of 2-bromoethansulfonate decreased (P < 0.05) CH4 emissions, and decreased (P < 0.05) the relative abundance of Archaea and Methanobacteriales. In conclusion, NFP may be efficacious for chronically inhibiting ruminal methanogenesis, and the replacement of dietary forage with DDGS attenuates CH4 emissions from ruminant animals. Changes in domain- and order-specific ribosomal DNA indicators of methanogens are not consistently correlated with changes in CH4 production.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The practice of running has consistently increased worldwide, and with it, related lower limb injuries. The type of running surface has been associated with running injury etiology, in addition other factors, such as the relationship between the amount and intensity of training. There is still controversy in the literature regarding the biomechanical effects of different types of running surfaces on foot-floor interaction. The aim of this study was to investigate the influence of running on asphalt, concrete, natural grass, and rubber on in-shoe pressure patterns in adult recreational runners. Forty-seven adult recreational runners ran twice for 40 m on all four different surfaces at 12 +/- 5% km . h(-1). Peak pressure, pressure-time integral, and contact time were recorded by Pedar X insoles. Asphalt and concrete were similar for all plantar variables and pressure zones. Running on grass produced peak pressures 9.3% to 16.6% lower (P < 0.001) than the other surfaces in the rearfoot and 4.7% to 12.3% (P < 0.05) lower in the forefoot. The contact time on rubber was greater than on concrete for the rearfoot and midfoot. The behaviour of rubber was similar to that obtained for the rigid surfaces - concrete and asphalt - possibly because of its time of usage (five years). Running on natural grass attenuates in-shoe plantar pressures in recreational runners. If a runner controls the amount and intensity of practice, running on grass may reduce the total stress on the musculoskeletal system compared with the total musculoskeletal stress when running on more rigid surfaces, such as asphalt and concrete.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study is to investigate cardiac bioeffects resulting from ultrasonic stimulation using a specific set of acoustical parameters. Ten Sprague-Dawley rats were anesthetized and exposed to 1-MHz ultrasound pulses of 3-MPa peak rarefactional pressure and approximately 1% duty factor. The pulse repetition frequency started slightly above the heart rate and was decreased by 1 Hz every 10 s, for a total exposure duration of 30 s. The control group was composed of five rats. Two-way analysis of variance for repeated measures and Bonferroni post hoc tests were used to compare heart rate and ejection fraction, which was used as an index of myocardial contractility. It was demonstrated for the first time that transthoracic ultrasound has the potential to decrease the heart rate by similar to 20%. The negative chronotropic effect lasted for at least 15 min after ultrasound exposure and there was no apparent gross damage to the cardiac tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the clinical setting, the early detection of myocardial injury induced by doxorubicin (DXR) is still considered a challenge. To assess whether ultrasonic tissue characterization (UTC) can identify early DXR-related myocardial lesions and their correlation with collagen myocardial percentages, we studied 60 rats at basal status and prospectively after 2mg/Kg/week DXR endovenous infusion. Echocardiographic examinations were conducted at baseline and at 8,10,12,14 and 16 mg/Kg DXR cumulative dose. The left ventricle ejection fraction (LVEF), shortening fraction (SF), and the UTC indices: corrected coefficient of integrated backscatter (IBS) (tissue IBS intensity/phantom IBS intensity) (CC-IBS) and the cyclic variation magnitude of this intensity curve (MCV) were measured. The variation of each parameter of study through DXR dose was expressed by the average and standard error at specific DXR dosages and those at baseline. The collagen percent (%) was calculated in six control group animals and 24 DXR group animals. CC-IBS increased (1.29 +/- 0.27 x 1.1 +/- 0.26-basal; p=0.005) and MCV decreased (9.1 +/- 2.8 x 11.02 +/- 2.6-basal; p=0.006) from 8 mg/Kg to 16mg/Kg DXR. LVEF presented only a slight but significant decrease (80.4 +/- 6.9% x 85.3 +/- 6.9%-basal, p=0.005) from 8 mg/Kg to 16 mg/Kg DXR. CC-IBS was 72.2% sensitive and 83.3% specific to detect collagen deposition of 4.24%(AUC=0.76). LVEF was not accurate to detect initial collagen deposition (AUC=0.54). In conclusion: UTC was able to early identify the DXR myocardial lesion when compared to LVEF, showing good accuracy to detect the initial collagen deposition in this experimental animal model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Because of their similar visual appearance, differentiation of left ventricular thrombotic material and myocardial wall can be difficult in contrast-enhanced coronary computed tomography (CT) angiography. OBJECTIVE: We identified typical thrombi attenuation of left ventricular thrombi with the use of CT measurement. METHODS: Over a time period of 6 years; we retrospectively identified 31 patients who showed a left ventricular thrombus in CT angiography datasets. Patients underwent routine contrast cardiac CT to investigate coronary artery disease. CT attenuation of each thrombus was assessed in the 4-chamber view. CT densities were also determined in the ascending aorta, left ventricle, and myocardial wall both in the mid-septal and mid-lateral segments. The mean CT attenuation of thrombi and the difference between attenuation in thrombi, left ventricular cavity, and myocardial wall were determined. The ratio of attenuation values in thrombus versus aorta and myocardium versus aorta were also determined. RESULTS: Mean (+/- SD) CT attenuation of all left ventricular thrombi in 31 patients was 43.2 +/- 15.3 HU (range, 25-80 HU). Mean CT densities of septal and lateral myocardial wall were 102.9 +/- 23.1 HU (range, 63-155 HU) and 99.3 +/- 28.7 HU (range, 72-191 HU), respectively, and were thus significantly higher than the CT attenuation of thrombi (P < 0.001). A threshold of 65 HU yielded a sensitivity, specificity, and positive and negative predictive values of 94%, 97%, 94%, and 97%, respectively, to differentiate thrombus from the myocardial wall. The mean ratio between CT attenuation of thrombus and CT attenuation within the ascending aorta was 0.11 +/- 0.05 (range, 0.04-0.23), which was significantly lower compared with the mean ratio between CT attenuation of the myocardial wall and the CT attenuation within the ascending aorta. CONCLUSION: CT attenuation within left ventricular thrombi was significantly lower than myocardial attenuation in CT angiography datasets. Assessment of CT attenuation may contribute to the differentiation of thrombi. (C) 2012 Society of Cardiovascular Computed Tomography. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of the complex reflection coefficient of ultrasonic shear-waves at the solid-liquid interface is a technique employed for the measurement of the viscoelastic properties of liquids. An interesting property of the measurement technique is the very small penetration depth of the shear-waves into the liquid sample, which permits measurements with liquid films of some micrometers thick. This property, along with the adhesion of oily substances to surfaces, can be used for the detection of oily contaminants in water. In this work, the employment of the ultrasonic shear-wave reflection technique to the detection of oily contaminants in water is proposed and the theoretical and experimental concepts involved are discussed. Preliminary experimental results show the measurement technique can detect SAE 40 automotive oil in water in volume proportions less than 0.5%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The purpose of this study was to analyze the influence of ultrasonic activation of calcium hydroxide (CH) pastes on pH and calcium release in simulated external root resorptions. Methods: Forty-six bovine incisors had their canals cleaned and instrumented, and defects were created in the external middle third of the roots, which were then used for the study. The teeth were externally made impermeable, except for the defected area, and divided into the following 4 groups containing 10 samples each according to the CH paste and the use or not of the ultrasonic activation: group 1: propylene glycol without ultrasonic activation, group 2: distilled water without ultrasonic activation, group 3: propylene glycol with ultrasonic activation, and group 4: distilled water with ultrasonic activation. After filling the canals with the paste, the teeth were restored and individually immersed into flasks with ultrapure water. The samples were placed into other flasks after 7, 15, and 30 days so that the water pH level could be measured by means of a pH meter. Calcium release was measured by means of an atomic absorption spectrophotometer. Six teeth were used as controls. The results were statistically compared using the Kruskal-Wallis and Mann-Whitney U tests (P < .05). Results: For all periods analyzed, the pH level was found to be higher when the CH paste was activated with ultrasound. Calcium release was significantly greater (P < .05) using ultrasonic activation after 7 and 30 days. Conclusions: The ultrasonic activation of CH pastes favored a higher pH level and calcium release in simulated external root resorptions. (J Endod 2012;38:834-837)