987 resultados para Turner Syndrome


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fungal infection was observed in Catla catla and Labeo rohita cultured in two private fish farms. The later stage of the infection resulted in ulcerations followed by haemorrhage on the dorsal surface of the body. Initially, usual treatments of copper sulphate, potassium permanganate and common salt solution were tried, but no improvement was observed. Then repeated intramuscular injections of homeopathic drug Heaper Sulpher and Arnica spray were given with encouraging results. Infection reported in another farm was also successfully controlled using a similar treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Incidence of Epizootic Ulcerative Syndrome (EUS) has been recorded for the first time in freshwater fishes in the endemic area of Punjab, Pakistan. Survey of private fish farms, hatchery and natural water bodies was conducted in a radius of 14 Km from around river Ravi near Lahore (Punjab Province) Pakistan. Out Of 1628 fishes belonging to 18 genera, 517 fishes of 10 genera were found affected with EUS. The incidence of EUS in culturable fishes was higher in Cirrhina mrigala (15.4%) moderate in Catla cat/a (13.3%) and lower in Labeo rohita (5.0%). Exotic fish, Chinese carp Ctenoparyngodon idella and Hypophthalmicthys molitrix were not affected with EUS. In non-culturable fishes the incidence of EUS was highest in Channa punctatus (72.8%) moderate in by C. straitus (65.45%) and comparatively lower Puntius ticto (43.7%). A slow growing temperature sensitive Saprolegnia spp. was isolated from all of EUS infected fish species. Aeromonas spp. and Pseudomonas spp. were isolated from the diseased fishes. Ectoparasites viz. Lernaea, Argulus and Triclwdina spp. were also isolated from the skin and gills of infected fish species. The disease was more severe in water having low alkalinity (70 mg/1), hardness (75 mg/1) and low temperature of 10-12 °C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Latex beads were sensitized with monoclonal antibodies (MAb) rose against VP28 of WSSV. The optimum concentration of MAb required to sensitize the latex beads was 125 µg/ml. The sensitized latex beads were used to detect WSSV from PCR-positive stomach tissue homogenates obtained from infected shrimp. Stomach tissue homogenates from WSSV-infected shrimp agglutinated the sensitized latex beads within 10 minutes, while uninfected samples did not produce any agglutination, although non-specific agglutinations were observed in some samples. The analytical sensitivity, analytical specificity, diagnostic sensitivity and diagnostic specificity of the (LAT) agglutination test were assessed. The analytical sensitivity of the test was 40 ng of purified WSSV (2 µg/ml). The sensitized latex beads did not agglutinate with normal shrimp tissue or MBV-infected tissue homogenate. The test has a diagnostic sensitivity of 70 and 45%, respectively, compared to single-step and nested PCR. The diagnostic specificity of the test was 82%. This test is a simple and rapid on-farm test which can be used to corroborate clinical signs for the detection of WSSV in grow-out ponds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Polymorphisms of CLEC4M have been associated with predisposition for infection by the severe acute respiratory syndrome coronavirus (SARS-CoV). DC-SIGNR, a C-type lectin encoded by CLEC4M, is a receptor for the virus. A variable number tandem

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dynamic centrifuge modelling has been carried out at Cambridge since the late 1970s. Over this period, three different mechanical earthquake actuators were developed. In this paper the development of a new servo-hydraulic earthquake actuator is described. The basic design principles are explained along with the need to carry out these designs to match the existing services and systems of the 35 year old Turner beam centrifuge at Cambridge. In addition, some of the features of the Turner beam centrifuge are exploited in the design of this new earthquake actuator. The paper also explains the mechanical fabrication of the actuator and the control systems that were developed in order to generate real earthquake motions. Finally, the performance of this new servo-hydraulic earthquake actuator is presented and assessed based on a wide range of earthquake input motions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a computational model of the thalamus and the cortex able to reproduce some essential epileptiform features commonly observed in the Landau-Kleffner syndrome. Investigation with this realistic model leads us to the formulation of a cellular mechanism that could be responsible for the epileptic discharges occuring with this severe syndrome. Understanding this mechanism is of prime importance for developing new therapeutical strategies. © 2007 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

White spot syndrome virus (WSSV) is a major pathogen in shrimp aquaculture. VP28 is one of the most important envelope proteins of WSSV. In this study, a recombinant antibody library, as single-chain fragment variable (scFv) format, displayed on phage was constructed using mRNA from spleen cells of mice immunized with-full-length VP28 expressed in Escherichia coli. After several rounds of panning, six scFv antibodies specifically binding to the epitopes in the N-terminal, middle, and C-terminal regions of VP28, respectively, were isolated from the library. Using these scFv antibodies as tools, the epitopes in VP28 were located on the envelope of the virion by immuno-electron Microscopy, Neutralization assay with these antibodies in vitro suggested that these epitopes may not be the attachment site of WSSV to host cell receptor. This study provides a new way to investigate the structure and function of the envelope proteins of WSSV. (c) 2008 Published by Elsevier Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper describes the rapid and label-free detection of the white spot syndrome virus (WSSV) using a surface plasmon resonance (SPR) device based on gold films prepared by electroless plating. The plating condition for obtaining films suitable for SPR measurements was optimized. Gold nanoparticles adsorbed on glass slides were characterized by transmission electron microscopy (TEM). Detection of the WSSV was performed through the binding between WSSV in solution and the anti-WSSV single chain variable fragment (scFv antibody) preimmobilized onto the sensor surface. Morphologies of the as-prepared gold films, gold films modified with self-assembled alkanethiol monolayers, and films covered with antibody were examined using an atomic force microscope (AFM). To demonstrate the viability of the method for real sample analysis, WSSV of different concentrations present in a shrimp hemolymph matrix was determined upon optimizing the surface density of the antibody molecules. The SPR device based on the electroless-plated gold films is capable of detecting concentration of WSSV as low as 2.5 ng/mL in 2% shrimp hemolymph, which is one to two orders of magnitude lower than the level measurable by enzyme-linked immunosorbant assays. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fluorescent quantitative PCR (FQ-PCR) assay utilizing SYBR green I dye is described for quantitation of white spot syndrome virus (WSSV) particles isolated from infected crayfish, Cambarus clarkii. For this assay, a primer set was designed which amplifies, with high efficiency and specificity, a 129 bp target sequence within ORF167 of the WSSV genome. Conveniently, WSSV particles can be added into the FQ-PCR assay with a simple and convenient method to release its DNA. To establish the basis for an in vitro neutralization test, primary cultures of shrimp cells were challenged with WSSV that had been incubated with a polyclonal anti-WSSV serum or with control proteins. The number of WSSV particles released from the cells after these treatments were assayed by FQ-PCR. This test may serve as a method to screen monoclonal antibody pools or recombinant antibody pools for neutralizing activity prior to in vivo animal experiments. (c) 2007 Elsevier B.V. All rights reserved.