731 resultados para Transducer


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tuneable optical sensors have been developed to sense chemical stimuli for a range of applications from bioprocess and environmental monitoring to medical diagnostics. Here, we present a porphyrin-functionalised optical sensor based on a holographic grating. The holographic sensor fulfils two key sensing functions simultaneously: it responds to external stimuli and serves as an optical transducer in the visible region of the spectrum. The sensor was fabricated via a 6 nanosecond-pulsed laser (350 mJ, λ = 532 nm) photochemical patterning process that enabled a facile fabrication. A novel porphyrin derivative was synthesised to function as the crosslinker of a polymer matrix, the light-absorbing material, the component of a diffraction grating, as well as the cation chelating agent in the sensor. The use of this multifunctional porphyrin permitted two-step fabrication of a narrow-band light diffracting photonic sensing structure. The resulting structure can be tuned finely to diffract narrow-band light based on the changes in the fringe spacing within the polymer and the system's overall index of refraction. We show the utility of the sensor by demonstrating its reversible colorimetric tuneability in response to variation in concentrations of organic solvents and metal cations (Cu 2+ and Fe2+) in the visible region of the spectrum (λmax ≈ 520-680 nm) with a response time within 50 s. Porphyrin-functionalised optical sensors offer great promise in fields varying from environmental monitoring to biochemical sensing to printable optical devices. This journal is © the Partner Organisations 2014.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Type I interferon (IFN) exerts its pleiotropic effects mainly through the JAK-STAT signaling pathway, which is presently best described in mammals. By subtractive suppression hybridization, two fish signaling factors, JAK1 and STAT1, had been identified in the IFN-induced crucian carp Carassius auratus L. blastulae embryonic (CAB) cells after treatment with UV-inactivated grass carp hemorrhagic virus (GCHV). Further, the full-length cDNA of STAT1, termed CaSTAT1, was obtained. It contains 2926 bp and encodes a protein of 718 aa. CaSTAT1 is most similar to rat STAT1 with 59% identity overall and displays all highly conserved domains that the STAT family possesses. Like human STAT1beta, it lacks the C-terminus acting as transcriptional activation domain in mammals. By contrast, only a single transcript was detected in virus-induced CAB cells. Expression analysis showed that CaSTAT1 could be activated by stimulation of CAB cells with poly I:C, active GCHV, UV-inactivated GCHV or CAB IFN, and displayed diverse expression patterns similar to that of mammalian STATI. Additionally, the expression of an antiviral gene CaMx1 was also induced under the same conditions, and expression difference between CaSTAT1 and CaMx1 was revealed by induction of CAB IFN. These results provide molecular evidence supporting the notion that the fish IFN signaling transduction pathway is similar to that in mammals. Fish IFN exerts its multiple functions, at least antiviral action, through a JAK-STAT pathway. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, the SiC-based clamped-clamped filter was designed and fabricated. The filter was composed of two clamped-clamped beam micromechanical resonators coupled by a spring coupling beam. Structural geometries, including the length and width of the resonator beam and coupling beam, were optimized by simulation for high frequency and high Q, under the material properties of SiC. The vibrating modes for the designed filter structure were analyzed by finite element analysis (FEA) method. For the optimized structure, the geometries of resonator beams and coupling beams, as well as the coupling position, the SiC-based clamped-clamped filter was fabricated by surface micromaching technology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lipids are the main component of all cell membranes and also important mimetic materials. Moreover, it was found recently that they can be used as sensitive membranes for olfactory and taste sensors. Hence the understanding of lipid resistance is important both in sensors and in life sciences. Thirteen lipids were examined by means of interdigital electrodes with narrow gaps of 20-50 mu m, made by IC technology. The membrane lateral resistance in air, resisting electrical voltage, the influence of impurities on resistance and the resistance change in acetic acid vapour are presented for the first time. It is shown that the electrical resistivity for self-assembling lipids depends on their duration of being in an electric field and the content of the conductive impurities. The interdigital electrode is a transducer as well as a powerful tool for researching biomaterials and mimicking materials. The conducting mechanism of lipids is discussed. This method is also suitable for some polymer membranes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For an olfactory sensor or electronic nose the task is not only to detect the object concentration, but also to recognize it. It is well known that all the elements can be identified by their charge to mass ratio e+/m. We tried to use this principle for molecular recognition. Two kinds of sensors are used simultaneously in testing. One is Quartz Crystal Microbalance (QCM) for detecting the change in mass, the other is Interdigital Electrode (IE) for detecting the change in conduction. In this paper the principle and the feasibility of this method are reported. The preliminary results on the recognition of alcohols are presented. The multisensor can be used as an instrument for research on material properties and kinetic process as well.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For an olfactory sensor or electronic nose, the task is not only to detect the object concentration, but also to recognize it. It is well known that all the elements can be identified by their charge to mass ratio e(+)/m. We tried to imitate this principle for molecular recognition. Two kinds of sensors are used simultaneously in testing. One is quartz crystal microbalance (QCM) for detecting the change in mass, the other is interdigital electrode (IE) for detecting the change in conduction, as an electro-mass multi-sensor (EMMS). in this paper, the principle and the feasibility of this method are discussed. The preliminary results on the recognition of alcohol by EMMS coated with lipids are presented. Meanwhile, the multi-sensor can also be used as an instrument for research on some physico-chemistry problems. The change in conduction of coated membrane caused by one absorbed molecule is reported. It is found that when a QCM is coated with membrane, it still obeys the relationship Delta F (frequency change of QCM) = K Delta m (mass change of absorbed substance) and the proportional coefficient, K, depends not only on quartz properties but also on membrane characteristics as well. (C) 2000 Elsevier Science S.A. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two biosensors for fermentation process control have been introduced, which were developed in our lab recently. One is an enzyme electrode-based on-line monitoring system for glutamate fermentation process control and the other is an H+-ISFET-based ENFET for penicillin G fermentation process control.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An electroosmotic pump (EOP) capable of generating pressure above 3 MPa and mul/min flow rate with reverse phase mobile phases of HPLC was constructed and evaluated. The pump consisted of three parallel connected fused silica capillary columns (25 cm x 320 mum I.D.) packed with 2 mum silica materials, hollow electrodes, a high voltage DC power supply, and. a liquid pressure transducer. The EOP was applied in a capillary liquid chromatographic system for mobile phase delivery instead of a mechanical pump. Standard samples containing thiourea, naphthalene, anthracene, phenanthrene and acetonitrile were separated on a 15 cm x 320 mum I.D. 5 mum Chromasil C-18 packed capillary column with acetonitrile/water as mobile phase. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The pH-sensitive property of the single-wall carbon nanotube modified electrode based oil the electroactive group on the single-wall carbon nanotube was explored by differential pulse voltammetry technique. In pH range 1-13 investigated in Britton-Robinson (B-R) buffer, the anodic peak shifted negatively along with the increase of pH exhibiting a reversible Nernstian response. Experiments were carried out to investigate the response of the single-wall carbon nanotube (SWNT) modified electrode to analytes associated with pH change. The response behavior of the modified electrode to ammonia was studied as an example. The potential response could reach equilibrium within 5 min. The modified electrode had good operational stability. Voltammetric urease and acetylcholinesterase biosensors were constructed by immobilizing the enzymes with sol-get hybrid material. The maximum potential shift could reach 0.130 and 0.220V for urea and acetylthiocholine, respectively. The methods for preparing sensor and biosensor were simple and reproducible and the range of analytes could be extended to substrates of other hydrolyases and esterases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

本文从化学传感器与催化之关连的角度论述了两学科共通的几个重要问题及其相互关系,诸如气体在固体表面上的吸附与反应行为,贵金属添加剂的作用,固体表面的改性及精细结构的控制等。前言众所周知,所谓化学传感器就是检知化学成分并获得电信号或光信号的装置。这里,化学传感器必须具备两项功能:一是对化学成分存在与否的检知功能(receptor),二是检知后转换为电信号的传感功能(transducer)。这其中利用了很多化学现象与材料物性,

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel design of a moving-coil transducer coupled with a low-hardness elastomer called “the gel surround” is presented in this thesis. This device is termed a “gel-type audio transducer”. The gel-type audio transducer has been developed to overcome the problems that conventional loudspeakers have suffered - that is, the problem with size of the audio device against the quality of sound at low frequency range. Therefore the research work presented herein aims to develop the “gel-type audio transducer” as a next-generation audio transducer for miniaturized woofers. The gel-type audio transducer consists of the magnetic and coil-drive plate assembly, and these parts are coupled by the gel surround. The transducer is driven by the electromagnetic conversion mechanism (a moving-coil transducer) and its output driving force can be greatly enhanced by applying the novel mechanism of the gel surround especially at low frequency range, resulting in the enhanced acoustic efficiency. The transducer can be attached to a stiff and light panel with both the optimized impedance matching and minimised wave collisions. The performance of the gel-type audio transducer is greatly influenced by the mass of the magnetic assembly and compliance of the “gel surround”. But as the size of the magnet and its weight have to be kept minimal for a miniaturisation of the device, the focus of the research is on the effect of the of the gel surround. As a result, the effect of the gel surround, made of the RTV (room-temperature vulcanising) silicone elastomer, TPE (thermoplastic elastomer), and the silicone foam, on generation of the output driving force, the energy transfer from the transducer to a panel to which the transducer is attached, and sound radiation from the vibrating panel, was investigated. This effect was studied by COMSOL multiphysics (FE analysis) and thereby, the simulated results were verified by experiments such as the laser scanning measurement, DMA (dynamic mechanical analyzer), and the acoustic test. Successful development of prototypes of the gel-type audio transducers, with an enhanced acoustic efficiency at reduced size and weight, was achieved. Implementation of the transducers into consumer applications was also demonstrated with their commercial values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The topic of this thesis is an acoustic scattering technique for detennining the compressibility and density of individual particles. The particles, which have diameters on the order of 10 µm, are modeled as fluid spheres. Ultrasonic tone bursts of 2 µsec duration and 30 MHz center frequency scatter from individual particles as they traverse the focal region of two confocally positioned transducers. One transducer acts as a receiver while the other both transmits and receives acoustic signals. The resulting scattered bursts are detected at 90° and at 180° (backscattered). Using either the long wavelength (Rayleigh) or the weak scatterer (Born) approximations, it is possible to detennine the compressibility and density of the particle provided we possess a priori knowledge of the particle size and the host properties. The detected scattered signals are digitized and stored in computer memory. With this information we can compute the mean compressibility and density averaged over a population of particles ( typically 1000 particles) or display histograms of scattered amplitude statistics. An experiment was run first run to assess the feasibility of using polystyrene polymer microspheres to calibrate the instrument. A second study was performed on the buffy coat harvested from whole human blood. Finally, chinese hamster ovary cells which were subject to hyperthermia treatment were studied in order to see if the instrument could detect heat induced membrane blebbing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

High-intensity focused ultrasound is a form of therapeutic ultrasound which uses high amplitude acoustic waves to heat and ablate tissue. HIFU employs acoustic amplitudes that are high enough that nonlinear propagation effects are important in the evolution of the sound field. A common model for HIFU beams is the Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation which accounts for nonlinearity, diffraction, and absorption. The KZK equation models diffraction using the parabolic or paraxial approximation. Many HIFU sources have an aperture diameter similar to the focal length and the paraxial approximation may not be appropriate. Here, results obtained using the “Texas code,” a time-domain numerical solution to the KZK equation, were used to assess when the KZK equation can be employed. In a linear water case comparison with the O’Neil solution, the KZK equation accurately predicts the pressure field in the focal region. The KZK equation was also compared to simulations of the exact fluid dynamics equations (no paraxial approximation). The exact equations were solved using the Fourier-Continuation (FC) method to approximate derivatives in the equations. Results have been obtained for a focused HIFU source in tissue. For a low focusing gain transducer (focal length 50λ and radius 10λ), the KZK and FC models showed excellent agreement, however, as the source radius was increased to 30λ, discrepancies started to appear. Modeling was extended to the case of tissue with the appropriate power law using a relaxation model. The relaxation model resulted in a higher peak pressure and a shift in the location of the peak pressure, highlighting the importance of employing the correct attenuation model. Simulations from the code that were compared to experimental data in water showed good agreement through the focal plane.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Acousto-optic imaging (AOI) in optically diffuse media is a hybrid imaging modality in which a focused ultrasound beam is used to locally phase modulate light inside of turbid media. The modulated optical field carries with it information about the optical properties in the region where the light and sound interact. The motivation for the development of AOI systems is to measure optical properties at large depths within biological tissue with high spatial resolution. A photorefractive crystal (PRC) based interferometry system is developed for the detection of phase modulated light in AOI applications. Two-wave mixing in the PRC creates a reference beam that is wavefront matched to the modulated optical field collected from the specimen. The phase modulation is converted to an intensity modulation at the optical detector when these two fields interfere. The interferometer has a high optical etendue, making it well suited for AOI where the scattered light levels are typically low. A theoretical model for the detection of acoustically induced phase modulation in turbid media using PRC based interferometry is detailed. An AOI system, using a single element focused ultrasound transducer to pump the AO interaction and the PRC based detection system, is fabricated and tested on tissue mimicking phantoms. It is found that the system has sufficient sensitivity to detect broadband AO signals generated using pulsed ultrasound, allowing for AOI at low time averaged ultrasound output levels. The spatial resolution of the AO imaging system is studied as a function of the ultrasound pulse parameters. A theoretical model of light propagation in turbid media is used to explore the dependence of the AO response on the experimental geometry, light collection aperture, and target optical properties. Finally, a multimodal imaging system combining pulsed AOI and conventional B- mode ultrasound imaging is developed. B-mode ultrasound and AO images of targets embedded in both highly diffuse phantoms and biological tissue ex vivo are obtained, and millimeter resolution is demonstrated in three dimensions. The AO images are intrinsically co-registered with the B-mode ultrasound images. The results suggest that AOI can be used to supplement conventional B-mode ultrasound imaging with optical information.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Acousto-optic (AO) sensing and imaging (AOI) is a dual-wave modality that combines ultrasound with diffusive light to measure and/or image the optical properties of optically diffusive media, including biological tissues such as breast and brain. The light passing through a focused ultrasound beam undergoes a phase modulation at the ultrasound frequency that is detected using an adaptive interferometer scheme employing a GaAs photorefractive crystal (PRC). The PRC-based AO system operating at 1064 nm is described, along with the underlying theory, validating experiments, characterization, and optimization of this sensing and imaging apparatus. The spatial resolution of AO sensing, which is determined by spatial dimensions of the ultrasound beam or pulse, can be sub-millimeter for megahertz-frequency sound waves.A modified approach for quantifying the optical properties of diffuse media with AO sensing employs the ratio of AO signals generated at two different ultrasound focal pressures. The resulting “pressure contrast signal” (PCS), once calibrated for a particular set of pressure pulses, yields a direct measure of the spatially averaged optical transport attenuation coefficient within the interaction volume between light and sound. This is a significant improvement over current AO sensing methods since it produces a quantitative measure of the optical properties of optically diffuse media without a priori knowledge of the background illumination. It can also be used to generate images based on spatial variations in both optical scattering and absorption. Finally, the AO sensing system is modified to monitor the irreversible optical changes associated with the tissue heating from high intensity focused ultrasound (HIFU) therapy, providing a powerful method for noninvasively sensing the onset and growth of thermal lesions in soft tissues. A single HIFU transducer is used to simultaneously generate tissue damage and pump the AO interaction. Experimental results performed in excised chicken breast demonstrate that AO sensing can identify the onset and growth of lesion formation in real time and, when used as feedback to guide exposure parameters, results in more predictable lesion formation.