959 resultados para THERMAL-BOUNDARY CONDITIONS
Resumo:
In hypersonic flight, the prediction of aerodynamic heating and the construction of a proper thermal protection system (TPS) are significantly important. In this study, the method of a film cooling technique, which is already the state of the art in cooling of gas turbine engines, is proposed for a fully reusable and active TPS. Effectiveness of the film cooling scheme to reduce convective heating rates for a blunt-nosed spacecraft flying at Mach number 6.56 and 40 deg angle of attack is investigated numerically. The inflow boundary conditions used the standard values at an altitude of 30 km. The computational domain consists of infinite rows of film cooling holes on the bottom of a blunt-nosed slab. Laminar and several turbulent calculations have been performed and compared. The influence of blowing ratios on the film cooling effectiveness is investigated. The results exhibit that the film cooling technique could be an effective method for an active cooling of blunt-nosed bodies in hypersonic flows.
Resumo:
In supernova remnants, the nonlinear amplification of magnetic fields upstream of collisionless shocks is essential for the acceleration of cosmic rays to the energy of the "knee" at 10(15.5) eV. A nonresonant instability driven by the cosmic ray current is thought to be responsible for this effect. We perform two-dimensional, particle-in-cell simulations of this instability. We observe an initial growth of circularly polarized nonpropagating magnetic waves as predicted in linear theory. It is demonstrated that in some cases the magnetic energy density in the growing waves can grow to at least 10 times its initial value. We find no evidence of competing modes, nor of significant modification by thermal effects. At late times, we observe saturation of the instability in the simulation, but the mechanism responsible is an artifact of the periodic boundary conditions and has no counterpart in the supernova-shock scenario.
Resumo:
In hypersonic flights, the prediction of aerodynamic heating and the construction of a proper thermal protection system (TPS) are significantly important. In this study, the method of a film cooling technique, which is already the state of the art in cooling gas turbine engine, is proposed for a fully reusable and active TPS. Effectiveness of the film cooling scheme to reduce convective heating rates for a blunt nosed spacecraft flying at Mach number 6.56 and 40 degree angle of attack is investigated numerically. The inflow boundary conditions used the standard values at an altitude of 30 km. Computational domain consists of infinite rows of film cooling holes on the bottom of a blunt-nosed slab. Laminar and several turbulent calculations have been performed and compared each other. The influence of blowing ratios on the film cooling effectiveness is investigated. The results exhibit that the film cooling technique could be an effective method for an active cooling of blunt-nosed bodies in hypersonic flows.
Resumo:
This paper presents the background rationale and key findings for a model-based study of supercritical waste heat recovery organic Rankine cycles. The paper’s objective is to cover the necessary groundwork to facilitate the future operation of a thermodynamic organic Rankine cycle model under realistic thermodynamic boundary conditions for performance optimisation of organic Rankine cycles. This involves determining the type of power cycle for organic Rankine cycles, the circuit configuration and suitable boundary conditions. The study focuses on multiple heat sources from vehicles but the findings are generally applicable, with careful consideration, to any waste heat recovery system. This paper introduces waste heat recovery and discusses the general merits of organic fluids versus water and supercritical operation versus subcritical operation from a theoretical perspective and, where possible, from a practical perspective. The benefits of regeneration are investigated from an efficiency perspective for selected subcritical and supercritical conditions. A simulation model is described with an introduction to some general Rankine cycle boundary conditions. The paper describes the analysis of real hybrid vehicle data from several driving cycles and its manipulation to represent the thermal inertia for model heat input boundary conditions. Basic theory suggests that selecting the operating pressures and temperatures to maximise the Rankine cycle performance is relatively straightforward. However, it was found that this may not be the case for an organic Rankine cycle operating in a vehicle. When operating in a driving cycle, the available heat and its quality can vary with the power output and between heat sources. For example, the available coolant heat does not vary much with the load, whereas the quantity and quality of the exhaust heat varies considerably. The key objective for operation in the vehicle is optimum utilisation of the available heat by delivering the maximum work out. The fluid selection process and the presentation and analysis of the final results of the simulation work on organic Rankine cycles are the subjects of two future publications.
Resumo:
Natural ventilation is a sustainable solution to maintaining healthy and comfortable environmental conditions in buildings. However, the effective design, construction and operation of naturally ventilated buildings require a good understanding of complex airflow patterns caused by the buoyancy and wind effects.The work presented in this article employed a 3D computational fluid dynamics (CFD) analysis in order to investigate environmental conditions and thermal comfort of the occupants of a highly-glazed naturally ventilated meeting room. This analysis was facilitated by the real-time field measurements performed in an operating building, and previously developed formal calibration methodology for reliable CFD models of indoor environments. Since, creating an accurate CFD model of an occupied space in a real-life scenario requires a high level of CFD expertise, trusted experimental data and an ability to interpret model input parameters; the calibration methodology guided towards a robust and reliable CFD model of the indoor environment. This calibrated CFD model was then used to investigate indoor environmental conditions and to evaluate thermal comfort indices for the occupants of the room. Thermal comfort expresses occupants' satisfaction with thermal environment in buildings by defining the range of indoor thermal environmental conditions acceptable to a majority of occupants. In this study, the thermal comfort analysis, supported by both field measurements and CFD simulation results, confirmed a satisfactory and optimal room operation in terms of thermal environment for the investigated real-life scenario. © 2013 Elsevier Ltd.
Resumo:
Accurate modelling of the internal climate of buildings is essential if Building Energy Management Systems (BEMS) are to efficiently maintain adequate thermal comfort. Computational fluid dynamics (CFD) models are usually utilised to predict internal climate. Nevertheless CFD models, although providing the necessary level of accuracy, are highly computationally expensive, and cannot practically be integrated in BEMS. This paper presents and describes validation of a CFD-ROM method for real-time simulations of building thermal performance. The CFD-ROM method involves the automatic extraction and solution of reduced order models (ROMs) from validated CFD simulations. ROMs are shown to be adequately accurate with a total error below 5% and to retain satisfactory representation of the phenomena modelled. Each ROM has a time to solution under 20seconds, which opens the potential of their integration with BEMS, giving real-time physics-based building energy modelling. A parameter study was conducted to investigate the applicability of the extracted ROM to initial boundary conditions different from those from which it was extracted. The results show that the ROMs retained satisfactory total errors when the initial conditions in the room were varied by ±5°C. This allows the production of a finite number of ROMs with the ability to rapidly model many possible scenarios.
Resumo:
Hemp-lime concrete is a sustainable alternative to standard building wall materials, with low associated embodied energy. It exhibits good hygric, acoustic and thermal properties, making it an exciting, sustainable building envelope material. When cast in temporary shuttering around a timber frame, it exhibits lower thermal conductivity than concrete, and consequently achieves low U-values in a primarily mono-material wall construction. Although cast relatively thick hemp-lime walls do not generally achieve the low U-values stipulated in building regulations. However assessment of its thermal performance through evaluation of its resistance to thermal transfer alone, underestimates its true thermal quality. The thermal inertia, or reluctance of the wall to change its temperature when exposed to changing environmental temperatures, also has a significant impact on the thermal quality of the wall, the thermal comfort of the interior space and energy consumption due to space heating. With a focus on energy reduction in buildings, regulations emphasise thermal resistance to heat transfer with only less focus on thermal inertia or storage benefits due to thermal mass. This paper investigates dynamic thermal responsiveness in hemp-lime concrete walls. It reports the influence of thermal conductivity, density and specific heat through analysis of steady state and transient heat transfer, in the walls. A novel hot-box design which isolates the conductive heat flow is used, and compared with tests in standard hot-boxes. Thermal diffusivity and effusivity are evaluated, using experimentally measured conductivity, based on analytical relationships. Experimental results evident that hemp-lime exhibits high thermal inertia. They show the thermal inertia characteristics compensate for any limitations in the thermal resistance of the construction material. When viewed together the thermal resistance and mass characteristics of hemp-lime are appropriate to maintain comfortable thermal indoor conditions and low energy operation.
Resumo:
This paper investigates the environmental conditions inside a highly-glazed cross-ventilated meeting room. A 3D computational fluid dynamics (CFD) model of an indoor environment is developed with the support of the field measurements performed in a normally operating room. The work presented here follows the steps of the formal calibration methodology for the development of CFD models of naturally ventilated environments. This paper utilises the calibration methodology in order to predict environmental conditions within the highly-glazed cross-ventilated room occupied by people. The CFD model is verified and validated with field measurements performed in an operating building. Moreover, parametric analysis determines the most influential boundary conditions on indoor air temperatures and air speeds
Resumo:
Moisture and heat management properties of Hemp and Stone Wool insulations were studied by mounting them between a hot and a cold climate chamber. Both insulations were exposed to identical hygrothermal boundary conditions. Quasi steady state and dynamic tests were carried out at a range of relative humidity exposures. The likelihood of interstitial condensation was assessed and equivalent thermal conductivity values of the insulations were determined. The adsorption-desorption isotherms of the insulations were also determined in a dynamic vapour sorption (DVS) instrument. It was observed that the likelihood of condensation was higher in Stone Wool insulation than in Hemp insulation. Hemp insulation performed better in managing moisture due to its high hygric inertia and water absorption capacity. It was observed that the equivalent thermal conductivity of Stone Wool insulation was dependent on enthalpy flow and phase change of moisture. The equivalent thermal conductivity of Hemp insulation was close to its declared thermal conductivity in dynamic conditions when high relative humidity exposures were transient. In quasi steady state boundary conditions, when the insulation was allowed to reach the equilibrium moisture content at ranges of relative humidity, there was a moisture dependent increase of thermal conductivity in Hemp insulation.
Resumo:
In der Praxis kommt es bei der spanenden Bearbeitung immer wieder zu großen Standwegunterschieden identischer Werkzeuge bei vordergründig identischen Bearbeitungsrandbedingungen. Insbesondere bei Fertigungsschritten, die das Bohren als Vorbearbeitung erfordern, kommt es gelegentlich zu atypischen Verschleißerscheinungen, die auf das Entstehen einer Neuhärtezone an der Werkstückoberfläche beim Bohren zurückgeführt werden. Grundsätzlich sind Randzonenveränderungen eine Folge der mechanischen und thermischen Beanspruchung bei der Bearbeitung. Beim Eindringen des Schneidkeils kommt es zu Kornverzerrungen, welche die Werkstückhärte bis in eine Tiefe von 40 bis 80 µm erhöhen können. Überdies wird die Randzone des Werkstücks durch den Bearbeitungsvorgang und den Spantransport erhitzt und durch den Kühlschmierstoff bzw. die so genannte Selbstabschreckung im Anschluss sehr schnell abgekühlt. So kann es in Abhängigkeit der Randbedingungen zu Gefügeänderungen mit härtesteigernder (Sekundärabschreckung) oder härtemindernder (Anlasseffekte) Wirkung kommen. Nicht zuletzt beeinflussen beide Beanspruchungsarten auch das Ausmaß der Eigenspannungen in der Werkstückoberfläche. In dieser Arbeit werden die beim Kernlochbohren erzeugten Randzonenveränderungen sowie die Standzeit von Folgebearbeitungswerkzeugen, wie Gewindebohrern und Gewindeformern, und deren Abhängigkeit vom Verschleißzustand des Kernlochbohrers untersucht. Weiterhin werden mit Hilfe einer Energiebilanz die Anteile herausgefiltert, die primär die Eigenschaften der Bohrungsrandzone beeinflussen. Dies geschieht mit Hilfe einer mathematischen Modellierung des Bohrprozesses, in der die Einflüsse der Schneidkantengeometrie, der Schneidkantenverrundung, der Schneidkantenfase sowie des Freiflächenverschleißes berücksichtigt werden.
Resumo:
Ein Luft-Erdwärmetauscher (L-EWT) kommt wegen seines niedrigen Energiebedarfs und möglicher guter Aufwandszahlen als umweltfreundliche Versorgungskomponente für Gebäude in Betracht. Dabei ist besonders vorteilhaft, dass ein L-EWT die Umgebungsluft je nach Jahreszeit vorwärmen oder auch kühlen kann. Dem zufolge sind L-EWT zur Energieeinsparung nicht nur für den Wohnhausbau interessant, sondern auch dort, wo immer noch große Mengen an fossiler Energie für die Raumkühlung benötigt werden, im Büro- und Produktionsgebäudesektor. Der Einsatzbereich eines L-EWT liegt zwischen Volumenströmen von 100 m3/h und mehreren 100.000 m3/h. Aus dieser Bandbreite und den instationären Randbedingungen entstehen erhebliche Schwierigkeiten, allgemeingültige Aussagen über das zu erwartende thermische Systemverhalten aus der Vielzahl möglicher Konstruktionsvarianten zu treffen. Hauptziel dieser Arbeit ist es, auf Basis umfangreicher, mehrjähriger Messungen an einer eigens konzipierten Testanlage und eines speziell angepassten numerischen Rechenmodells, Kennzahlen zu entwickeln, die es ermöglichen, die Betriebseigenschaften eines L-EWT im Planungsalltag zu bestimmen und ein technisch, ökologisch wie ökonomisch effizientes System zu identifizieren. Es werden die Kennzahlen elewt (Aufwandszahl), QV (Netto-Volumenleistung), ME (Meterertrag), sowie die Kombination aus v (Strömungsgeschwindigkeit) und VL (Metervolumenstrom) definiert, die zu wichtigen Informationen führen, mit denen die Qualität von Systemvarianten in der Planungsphase bewertet werden können. Weiterführende Erkenntnisse über die genauere Abschätzung von Bodenkennwerten werden dargestellt. Die hygienische Situation der durch den L-EWT transportierten Luft wird für die warme Jahreszeit, aufgrund auftretender Tauwasserbildung, beschrieben. Aus diesem Grund werden alle relevanten lufthygienischen Parameter in mehreren aufwendigen Messkampagnen erfasst und auf pathogene Wirkungen überprüft. Es wird über Sensitivitätsanalysen gezeigt, welche Fehler bei Annahme falscher Randbedingungen eintreten. Weiterhin werden in dieser Arbeit wesentliche, grundsätzliche Erkenntnisse aufbereitet, die sich aus der Betriebsbeobachtung und der Auswertung der umfangreich vorliegenden Messdaten mehrerer Anlagen ergeben haben und für die praktische Umsetzung und die Betriebsführung bedeutend sind. Hinweise zu Materialeigenschaften und zur Systemwirtschaftlichkeit sind detailliert aufgeführt.
Resumo:
Bei Meßprojekten in denen Gebäude mit installierter Lüftungsanlage untersucht wurden, stellte man immer wieder ein breite Streuung der Meßwerte, als auch eine oftmals deutliche Abweichung vom vorher ermittelten Heizwärmebedarf der Gebäude fest. Es wird vermutet, daß diese Unterschiede systemspezifische Ursachen haben, ein Nachweis kann aufgrund der geringen Anzahl vorhandener Meßpunkte jedoch nicht geführt werden. Um die Sensitivität verschiedener Randbedingungen auf den Energieverbrauch zu ermitteln, wird im vorliegenden Forschungsprojekt ein Simulationsmodell erstellt. Das thermische Verhalten und die Durchströmung des Gebäudes werden durch ein gekoppeltes Modell abgebildet. Unterschiedliche Lüftungsanlagensysteme werden miteinander verglichen. Auf Basis vorhandener Meßdaten wird ein klimaabhängiges Modell zur Fensterlüftung entwickelt, welches in die Modellbildung der Gebäudedurchströmung mit einfließt. Feuchtegeregelte Abluftanlagen sind in der Lage den mittleren Luftwechsel auf ein hygienisch sinnvollen Wert zu begrenzen. Sie erweisen sich im Hinblick auf die Sensitivität verschiedener Randbedingungen als robuste Systeme. Trotz Einsatz von Lüftungsanlagen kann je nach Betriebszustand insbesondere bei Abluftanlagen keine ausreichende Luftqualität sichergestellt werden. Zukünftige Systeme dürfen das "Lüftungssystem" Fenster nicht vernachlässigen, sondern müssen es in das Gesamtkonzept mit einbeziehen.
Resumo:
Aquesta tesi permet adquirir una millor comprensió de la dinàmica dels plomalls hidrotèrmics en l'estany de Banyoles i correlacionar la meteorologia amb els processos de fluïdització que s'hi produeixen. S'han trobat els patrons atmosfèrics que generen els esdeveniments de les fluïditzacions així com la seva freqüència. Això és crucial per a determinar la qualitat de l'aigua de l'estany. S'han trobat inhomogeneïtats espacials tant en el plomall crònic que es desenvolupa en la cubeta B1, com en el plomall episòdic de la cubeta B2. S'ha caracteritzat l'estructura del plomall generat a la cubeta B2 i s'ha comparat amb el desenvolupat a la cubeta B1. Finalment, s'han realitzat simulacions numèriques mitjançant un model numèric: MIT General Circulation Model, en el qual s'ha hagut de fer canvis en les condicions de contorn per a situar la font convectiva al fons de la columna d'aigua. Les simulacions s'han comparat amb els resultats experimentals trobats mitjançant campanyes.
Resumo:
The flow dynamics of crystal-rich high-viscosity magma is likely to be strongly influenced by viscous and latent heat release. Viscous heating is observed to play an important role in the dynamics of fluids with temperature-dependent viscosities. The growth of microlite crystals and the accompanying release of latent heat should play a similar role in raising fluid temperatures. Earlier models of viscous heating in magmas have shown the potential for unstable (thermal runaway) flow as described by a Gruntfest number, using an Arrhenius temperature dependence for the viscosity, but have not considered crystal growth or latent heating. We present a theoretical model for magma flow in an axisymmetric conduit and consider both heating effects using Finite Element Method techniques. We consider a constant mass flux in a 1-D infinitesimal conduit segment with isothermal and adiabatic boundary conditions and Newtonian and non-Newtonian magma flow properties. We find that the growth of crystals acts to stabilize the flow field and make the magma less likely to experience a thermal runaway. The additional heating influences crystal growth and can counteract supercooling from degassing-induced crystallization and drive the residual melt composition back towards the liquidus temperature. We illustrate the models with results generated using parameters appropriate for the andesite lava dome-forming eruption at Soufriere Hills Volcano, Montserrat. These results emphasize the radial variability of the magma. Both viscous and latent heating effects are shown to be capable of playing a significant role in the eruption dynamics of Soufriere Hills Volcano. Latent heating is a factor in the top two kilometres of the conduit and may be responsible for relatively short-term (days) transients. Viscous heating is less restricted spatially, but because thermal runaway requires periods of hundreds of days to be achieved, the process is likely to be interrupted. Our models show that thermal evolution of the conduit walls could lead to an increase in the effective diameter of flow and an increase in flux at constant magma pressure.
Resumo:
A new boundary integral operator is introduced for the solution of the soundsoft acoustic scattering problem, i.e., for the exterior problem for the Helmholtz equation with Dirichlet boundary conditions. We prove that this integral operator is coercive in L2(Γ) (where Γ is the surface of the scatterer) for all Lipschitz star-shaped domains. Moreover, the coercivity is uniform in the wavenumber k = ω/c, where ω is the frequency and c is the speed of sound. The new boundary integral operator, which we call the “star-combined” potential operator, is a slight modification of the standard combined potential operator, and is shown to be as easy to implement as the standard one. Additionally, to the authors' knowledge, it is the only second-kind integral operator for which convergence of the Galerkin method in L2(Γ) is proved without smoothness assumptions on Γ except that it is Lipschitz. The coercivity of the star-combined operator implies frequency-explicit error bounds for the Galerkin method for any approximation space. In particular, these error estimates apply to several hybrid asymptoticnumerical methods developed recently that provide robust approximations in the high-frequency case. The proof of coercivity of the star-combined operator critically relies on an identity first introduced by Morawetz and Ludwig in 1968, supplemented further by more recent harmonic analysis techniques for Lipschitz domains.