928 resultados para Surgical Instruments
Resumo:
To develop real-time simulations of wind instruments, digital waveguides filters can be used as an efficient representation of the air column. Many aerophones are shaped as horns which can be approximated using conical sections. Therefore the derivation of conical waveguide filters is of special interest. When these filters are used in combination with a generalized reed excitation, several classes of wind instruments can be simulated. In this paper we present the methods for transforming a continuous description of conical tube segments to a discrete filter representation. The coupling of the reed model with the conical waveguide and a simplified model of the termination at the open end are described in the same way. It turns out that the complete lossless conical waveguide requires only one type of filter.Furthermore, we developed a digital reed excitation model, which is purely based on numerical integration methods, i.e., without the use of a look-up table.
Resumo:
Capillary-based systems for measuring the input impedance of musical wind instruments were first developed in the mid-20th century and remain in widespread use today. In this paper, the basic principles and assumptions underpinning the design of such systems are examined. Inexpensive modifications to a capillary-based impedance measurement set-up made possible due to advances in computing and data acquisition technology are discussed. The modified set-up is able to measure both impedance magnitude and impedance phase even though it only contains one microphone. In addition, a method of calibration is described that results in a significant improvement in accuracy when measuring high impedance objects on the modified capillary-based system. The method involves carrying out calibration measurements on two different objects whose impedances are well-known theoretically. The benefits of performing two calibration measurements (as opposed to the one calibration measurement that has been traditionally used) are demonstrated experimentally through input impedance measurements on two test objects and a Boosey and Hawkes oboe. © S. Hirzel Verlag · EAA.
Resumo:
Data obtained with any research tool must be reproducible, a concept referred to as reliability. Three techniques are often used to evaluate reliability of tools using continuous data in aging research: intraclass correlation coefficients (ICC), Pearson correlations, and paired t tests. These are often construed as equivalent when applied to reliability. This is not correct, and may lead researchers to select instruments based on statistics that may not reflect actual reliability. The purpose of this paper is to compare the reliability estimates produced by these three techniques and determine the preferable technique. A hypothetical dataset was produced to evaluate the reliability estimates obtained with ICC, Pearson correlations, and paired t tests in three different situations. For each situation two sets of 20 observations were created to simulate an intrarater or inter-rater paradigm, based on 20 participants with two observations per participant. Situations were designed to demonstrate good agreement, systematic bias, or substantial random measurement error. In the situation demonstrating good agreement, all three techniques supported the conclusion that the data were reliable. In the situation demonstrating systematic bias, the ICC and t test suggested the data were not reliable, whereas the Pearson correlation suggested high reliability despite the systematic discrepancy. In the situation representing substantial random measurement error where low reliability was expected, the ICC and Pearson coefficient accurately illustrated this. The t test suggested the data were reliable. The ICC is the preferred technique to measure reliability. Although there are some limitations associated with the use of this technique, they can be overcome.
Resumo:
Purpose: To describe a new surgical approach in the management of pseudophakic malignant glaucoma. Design: Noncomparative case series. Participants: Five consecutive patients with pseudophakic malignant glaucoma. Methods: All patients underwent zonulo-hyaloido-vitrectomy. The procedure involves the performance of zonulectomy, hyaloidectomy, and anterior vitrectomy (zonulo-hyaloido-vitrectomy) through a peripheral iridectomy or iridotomy via the anterior chamber. Main Outcome Measures: Medications, visual acuity, intraocular pressure, and anterior and posterior segment findings were recorded before and after surgery. Results: Resolution of the malignant glaucoma was achieved in all cases. No recurrences were observed after a median follow-up of 5.5 months (range, 1-9 months). In one patient with extensive anterior synechiae, bleb failure occurred after the resolution of the malignant glaucoma. This patient was treated successfully with a guarded filtration procedure supplemented with 5-fluorouracil. No other complications were observed. Conclusions: Zonulo-hyaloido-vitrectomy via the anterior segment appears to be an alternative option in the treatment of patients with pseudophakic malignant glaucoma. © 2001 by the American Academy of Ophthalmology.
Resumo:
Purpose: To compare long-term cognitive outcomes of patients treated with surgical clipping or endovascular coiling after subarachnoid haemorrhage (SAH). Method: Retrospective matched cohort study assessed neuropsychological functioning at least 12 months after aneurysmal SAH treatment. Fourteen patients treated by endovascular coiling and nine patients treated by surgical clipping participated. After gaining written consent, a comprehensive neuropsychological battery was completed. Standardised tests were employed to assess pre-morbid and current intellectual functioning (IQ), attention, speed of information processing, memory and executive function as well as psychosocial functioning and affect. Results: Treatment groups were not significantly different in terms of age, pre-morbid IQ, time from injury to treatment or time since injury. A significant effect of treatment on full-scale IQ score (p = 0.025), performance IQ (p = 0.045) and verbal IQ score (p = 0.029), all favouring the coiled group was observed. A medium effect size between groups difference in immediate memory (p = 0.19, partial ?(2) = 0.08) was also observed. No significant between group differences on attention, executive functioning and speed of information processing measures or mood and psychosocial functioning were noted. Both groups reported increased anxiety and memory, attention and speed of information processing deficits relative to normative data. Conclusions: Study findings indicate fewer cognitive deficits following endovascular coiling. Cognitive deficits in the clipped group may be due in part to the invasive nature of neurosurgical clipping. Further prospective research with regard to long-term cognitive and emotional outcomes is warranted. [Box: see text].
Resumo:
Researchers and clinicians have experienced substantial difficulties locating measures that are suitable for use within palliative care settings. This article details the psychometric properties of nine instruments designed to assess the following psychosocial characteristics of family caregivers: competence, mastery, self-efficacy, burden, optimism, preparedness, social support, rewards, and mutuality. Results are based on the responses of 106 primary family caregivers caring for relatives dying of cancer. Principal components extraction with varimax rotation was used to explore the underlying structure of each measure. Following the exclusion of complex variables, suggested components for most measures comprised relatively homogenous items, which were good to excellent measures of each component. Some components comprised only two items; however, Cronbach's alphas typically indicated moderate to high levels of internal consistency. Overall, the results of this study suggest that most of the measures analyzed, excepting the mastery and mutuality scales, can be recommended to examine the family caregiver experience and test supportive interventions.
Resumo:
BACKGROUND: Open angle glaucoma (OAG) is a common cause of blindness.
OBJECTIVES: To assess the effects of medication compared with initial surgery in adults with OAG.
SEARCH METHODS: We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2012, Issue 7), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to August 2012), EMBASE (January 1980 to August 2012), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to August 2012), Biosciences Information Service (BIOSIS) (January 1969 to August 2012), Cumulative Index to Nursing and Allied Health Literature (CINAHL) (January 1937 to August 2012), OpenGrey (System for Information on Grey Literature in Europe) (www.opengrey.eu/), Zetoc, the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 1 August 2012. The National Research Register (NRR) was last searched in 2007 after which the database was archived. We also checked the reference lists of articles and contacted researchers in the field.
SELECTION CRITERIA: We included randomised controlled trials (RCTs) comparing medications with surgery in adults with OAG.
DATA COLLECTION AND ANALYSIS: Two authors independently assessed trial quality and extracted data. We contacted study authors for missing information.
MAIN RESULTS: Four trials involving 888 participants with previously untreated OAG were included. Surgery was Scheie's procedure in one trial and trabeculectomy in three trials. In three trials, primary medication was usually pilocarpine, in one trial it was a beta-blocker.The most recent trial included participants with on average mild OAG. At five years, the risk of progressive visual field loss, based on a three unit change of a composite visual field score, was not significantly different according to initial medication or initial trabeculectomy (odds ratio (OR) 0.74, 95% confidence interval (CI) 0.54 to 1.01). In an analysis based on mean difference (MD) as a single index of visual field loss, the between treatment group difference in MD was -0.20 decibel (dB) (95% CI -1.31 to 0.91). For a subgroup with more severe glaucoma (MD -10 dB), findings from an exploratory analysis suggest that initial trabeculectomy was associated with marginally less visual field loss at five years than initial medication, (mean difference 0.74 dB (95% CI -0.00 to 1.48). Initial trabeculectomy was associated with lower average intraocular pressure (IOP) (mean difference 2.20 mmHg (95% CI 1.63 to 2.77) but more eye symptoms than medication (P = 0.0053). Beyond five years, visual acuity did not differ according to initial treatment (OR 1.48, 95% CI 0.58 to 3.81).From three trials in more severe OAG, there is some evidence that medication was associated with more progressive visual field loss and 3 to 8 mmHg less IOP lowering than surgery. In the longer-term (two trials) the risk of failure of the randomised treatment was greater with medication than trabeculectomy (OR 3.90, 95% CI 1.60 to 9.53; hazard ratio (HR) 7.27, 95% CI 2.23 to 25.71). Medications and surgery have evolved since these trials were undertaken.In three trials the risk of developing cataract was higher with trabeculectomy (OR 2.69, 95% CI 1.64 to 4.42). Evidence from one trial suggests that, beyond five years, the risk of needing cataract surgery did not differ according to initial treatment policy (OR 0.63, 95% CI 0.15 to 2.62).Methodological weaknesses were identified in all the trials.
AUTHORS' CONCLUSIONS: Primary surgery lowers IOP more than primary medication but is associated with more eye discomfort. One trial suggests that visual field restriction at five years is not significantly different whether initial treatment is medication or trabeculectomy. There is some evidence from two small trials in more severe OAG, that initial medication (pilocarpine, now rarely used as first line medication) is associated with more glaucoma progression than surgery. Beyond five years, there is no evidence of a difference in the need for cataract surgery according to initial treatment.The clinical and cost-effectiveness of contemporary medication (prostaglandin analogues, alpha2-agonists and topical carbonic anhydrase inhibitors) compared with primary surgery is not known.Further RCTs of current medical treatments compared with surgery are required, particularly for people with severe glaucoma and in black ethnic groups. Outcomes should include those reported by patients. Economic evaluations are required to inform treatment policy.
Resumo:
PURPOSE: To report a new technique to correct tube position in anterior chamber after glaucoma drainage device implantation.
PATIENT AND METHODS: A patient who underwent a glaucoma drainage device implantation was noted to have the tube touching the corneal endothelium. A 10/0 polypropylene suture with double-armed 3-inch long straight needle was placed transcamerally from limbus to limbus, in the superior part of the eye, passing the needle in front of the tube.
RESULTS: The position of the tube in the anterior chamber was corrected with optimal distance from corneal endothelium and iris surface. The position remained satisfactory after 20 months of follow-up.
CONCLUSIONS: The placement of a transcameral suture offers a safe, quick, and minimal invasive intervention for the correction of the position of a glaucoma drainage device tube in the anterior chamber.
Resumo:
A 42-year-old man has been under long-term follow-up since he was a child for congenital glaucoma and buphthalmos in both eyes. His left eye best corrected visual acuity (BCVA) was counting fingers, due to end-stage glaucoma. He was on maximal medical therapy with an intraocular pressure (IOP) maintained at mid to low twenties. His right eye, the only seeing eye, had a BCVA of 6/9. This eye had undergone multiple glaucoma laser and surgical procedures, including an initial first Molteno drainage device inserted superonasally that failed in April 2003 due to fibrotic membrane over the tube opening. As a result, he subsequently had a second Molteno drainage device inserted inferotemporally. To further maximize his vision he had an uncomplicated cataract extraction and intraocular lens implant in December 2004, after which he developed postoperative cystoid macular edema and corneal endothelial failure. He underwent a penetrating keratoplasty in the right eye thereafter in March 2007. After approximately a year, the second Molteno device developed drainage tube retraction, which was managed surgically to maintain optimum IOP in the right eye. His right eye vision to date is maintained at 6/12. © 2011 Mustafa and Azuara-Blanco.
Resumo:
PURPOSE: To identify vision Patient-Reported Outcomes instruments relevant to glaucoma and assess their content validity.
METHODS: MEDLINE, MEDLINE in Process, EMBASE and SCOPUS (to January 2009) were systematically searched. Observational studies or randomised controlled trials, published in English, reporting use of vision instruments in glaucoma studies involving adults were included. In addition, reference lists were scanned to identify additional studies describing development and/or validation to ascertain the final version of the instruments. Instruments' content was then mapped onto a theoretical framework, the World Health Organization International Classification of Functioning, Disability and Health. Two reviewers independently evaluated studies for inclusion and quality assessed instrument content.
RESULTS: Thirty-three instruments were identified. Instruments were categorised into thirteen vision status, two vision disability, one vision satisfaction, five glaucoma status, one glaucoma medication related to health status, five glaucoma medication side effects and six glaucoma medication satisfaction measures according to each instruments' content. The National Eye Institute Visual Function Questionnaire-25, Impact of Vision Impairment and Treatment Satisfaction Survey-Intraocular Pressure had the highest number of positive ratings in the content validity assessment.
CONCLUSION: This study provides a descriptive catalogue of vision-specific PRO instruments, to inform the choice of an appropriate measure of patient-reported outcomes in a glaucoma context.
Resumo:
PURPOSE: To evaluate the relative benefits and to identify any adverse effects of surgical interventions for limbal stem cell deficiency (LSCD).
DESIGN: Systematic literature review.
METHODS: We searched the following electronic databases from January 1, 1989 through September 30, 2006: MEDLINE, EMBASE, Science citation index, BIOSIS, and the Cochrane Library. In addition, reference lists were scanned to identify any additional reports. The quality of published reports was assessed using standard methods. The main outcome measure was improvement in vision of at least two Snellen lines of best-corrected visual acuity (BCVA). Data on adverse outcomes also were collected.
RESULTS: Twenty-six studies met the inclusion criteria. There were no randomized controlled studies. All 26 studies were either prospective or retrospective case series. For bilateral severe LSCD, keratolimbal allograft was the most common intervention with systemic immunosuppression. Other interventions included eccentric penetrating keratolimbal allografts and cultivated autologous oral mucosal epithelial grafts. An improvement in BCVA of two lines or more was reported in 31% to 67% of eyes. For unilateral severe LSCD, the most common surgical intervention was contralateral conjunctival limbal autograft, with 35% to 88% of eyes gaining an improvement in BCVA of two lines or more. The only study evaluating partial LSCD showed an improvement in BCVA of two lines or more in 39% of eyes.
CONCLUSIONS: Studies to date have not provided strong evidence to guide clinical practice on which surgery is most beneficial to treat various types of LSCD. Standardized data collection in a multicenter LSCD register is suggested.
Resumo:
BACKGROUND: Open angle glaucoma (OAG) is the commonest cause of irreversible blindness worldwide. OBJECTIVES: To study the relative effects of medical and surgical treatment of OAG. SEARCH STRATEGY: We searched the Cochrane Central Register of Controlled Trials (The Cochrane Library Issue 1, 2005), MEDLINE (1966 to February 2005), EMBASE (1988 to February 2005), and reference lists of articles. We also contacted researchers in the field. SELECTION CRITERIA: Randomised controlled trials comparing medications to surgery in adults. DATA COLLECTION AND ANALYSIS: Two authors independently assessed trial quality and extracted data. We contacted trial investigators for missing information. MAIN RESULTS: Four trials involving 888 participants with previously untreated OAG were included. Surgery was Scheie's procedure in one trial and trabeculectomy in three trials. In three trials, primary medication was usually pilocarpine, in one trial a beta-blocker.In the most recent trial, participants with mild OAG, progressive visual field (VF) loss, after adjustment for cataract surgery, was not significantly different for medications compared to trabeculectomy (Odds ratio (OR) 0.74; 95% CI 0.54 to 1.01). Reduction of vision, with a higher risk of developing cataract (OR 2.69, 95%% CI 1.64 to 4.42), and more patient discomfort was more likely with trabeculectomy than medication.There is some evidence, from three trials, for people with moderately advanced glaucoma that medication is associated with more progressive VF loss and 6 to 8 mmHg less intraocular pressure (IOP) lowering than surgery, either by a Scheie's procedure or trabeculectomy. There was a trend towards an increased risk of failed IOP control over time for initial pilocarpine treatment compared to trabeculectomy. In the longer-term (two trials) the risk of failure was significantly greater with medication than trabeculectomy (OR 3.90, 95% CI 1.60 to 9.53; HR 7.27, 95% CI 2.23 to 25.71). Medicine and surgery have evolved since these trials were undertaken, and additionally the evidence is potentially subject to detection and attrition bias. AUTHORS' CONCLUSIONS: Evidence from one trial suggests, for mild OAG, that VF deterioration up to five-years is not significantly different whether treatment is initiated with medication or trabeculectomy. Reduced vision, cataract and eye discomfort are more likely with trabeculectomy. There is some evidence, for more severe OAG, that initial medication (pilocarpine, now rarely used as first line medication) is associated with greater VF deterioration than surgery. In general, surgery lowers IOP more than medication.There was no evidence to determine the effectiveness of contemporary medication (prostaglandin analogues, alpha2-agonists and topical carbonic anhydrase inhibitors) compared to surgery in severe OAG, and in people of black African ethnic origin who have a greater risk of more severe open angle glaucoma. More research is required.