223 resultados para Supine
Resumo:
Advancements in retinal imaging technologies have drastically improved the quality of eye care in the past couple decades. Scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT) are two examples of critical imaging modalities for the diagnosis of retinal pathologies. However current-generation SLO and OCT systems have limitations in diagnostic capability due to the following factors: the use of bulky tabletop systems, monochromatic imaging, and resolution degradation due to ocular aberrations and diffraction.
Bulky tabletop SLO and OCT systems are incapable of imaging patients that are supine, under anesthesia, or otherwise unable to maintain the required posture and fixation. Monochromatic SLO and OCT imaging prevents the identification of various color-specific diagnostic markers visible with color fundus photography like those of neovascular age-related macular degeneration. Resolution degradation due to ocular aberrations and diffraction has prevented the imaging of photoreceptors close to the fovea without the use of adaptive optics (AO), which require bulky and expensive components that limit the potential for widespread clinical use.
In this dissertation, techniques for extending the diagnostic capability of SLO and OCT systems are developed. These techniques include design strategies for miniaturizing and combining SLO and OCT to permit multi-modal, lightweight handheld probes to extend high quality retinal imaging to pediatric eye care. In addition, a method for extending true color retinal imaging to SLO to enable high-contrast, depth-resolved, high-fidelity color fundus imaging is demonstrated using a supercontinuum light source. Finally, the development and combination of SLO with a super-resolution confocal microscopy technique known as optical photon reassignment (OPRA) is demonstrated to enable high-resolution imaging of retinal photoreceptors without the use of adaptive optics.
Resumo:
Purpose: The purpose of this work was to investigate the breast dose saving potential of a breast positioning technique (BP) for thoracic CT examinations with organ-based tube current modulation (OTCM).
Methods: The study included 13 female patient models (XCAT, age range: 27-65 y.o., weight range: 52 to 105.8 kg). Each model was modified to simulate three breast sizes in standard supine geometry. The modeled breasts were further deformed, emulating a BP that would constrain the breasts within 120° anterior tube current (mA) reduction zone. The tube current value of the CT examination was modeled using an attenuation-based program, which reduces the radiation dose to 20% in the anterior region with a corresponding increase to the posterior region. A validated Monte Carlo program was used to estimate organ doses with a typical clinical system (SOMATOM Definition Flash, Siemens Healthcare). The simulated organ doses and organ doses normalized by CTDIvol were compared between attenuation-based tube current modulation (ATCM), OTCM, and OTCM with BP (OTCMBP).
Results: On average, compared to ATCM, OTCM reduced the breast dose by 19.3±4.5%, whereas OTCMBP reduced breast dose by 36.6±6.9% (an additional 21.3±7.3%). The dose saving of OTCMBP was more significant for larger breasts (on average 32, 38, and 44% reduction for 0.5, 1.5, and 2.5 kg breasts, respectively). Compared to ATCM, OTCMBP also reduced thymus and heart dose by 12.1 ± 6.3% and 13.1 ± 5.4%, respectively.
Conclusions: In thoracic CT examinations, OTCM with a breast positioning technique can markedly reduce unnecessary exposure to the radiosensitive organs in the anterior chest wall, specifically breast tissue. The breast dose reduction is more notable for women with larger breasts.
Resumo:
As complex radiotherapy techniques become more readily-practiced, comprehensive 3D dosimetry is a growing necessity for advanced quality assurance. However, clinical implementation has been impeded by a wide variety of factors, including the expense of dedicated optical dosimeter readout tools, high operational costs, and the overall difficulty of use. To address these issues, a novel dry-tank optical CT scanner was designed for PRESAGE 3D dosimeter readout, relying on 3D printed components and omitting costly parts from preceding optical scanners. This work details the design, prototyping, and basic commissioning of the Duke Integrated-lens Optical Scanner (DIOS).
The convex scanning geometry was designed in ScanSim, an in-house Monte Carlo optical ray-tracing simulation. ScanSim parameters were used to build a 3D rendering of a convex ‘solid tank’ for optical-CT, which is capable of collimating a point light source into telecentric geometry without significant quantities of refractive-index matched fluid. The model was 3D printed, processed, and converted into a negative mold via rubber casting to produce a transparent polyurethane scanning tank. The DIOS was assembled with the solid tank, a 3W red LED light source, a computer-controlled rotation stage, and a 12-bit CCD camera. Initial optical phantom studies show negligible spatial inaccuracies in 2D projection images and 3D tomographic reconstructions. A PRESAGE 3D dose measurement for a 4-field box treatment plan from Eclipse shows 95% of voxels passing gamma analysis at 3%/3mm criteria. Gamma analysis between tomographic images of the same dosimeter in the DIOS and DLOS systems show 93.1% agreement at 5%/1mm criteria. From this initial study, the DIOS has demonstrated promise as an economically-viable optical-CT scanner. However, further improvements will be necessary to fully develop this system into an accurate and reliable tool for advanced QA.
Pre-clinical animal studies are used as a conventional means of translational research, as a midpoint between in-vitro cell studies and clinical implementation. However, modern small animal radiotherapy platforms are primitive in comparison with conventional linear accelerators. This work also investigates a series of 3D printed tools to expand the treatment capabilities of the X-RAD 225Cx orthovoltage irradiator, and applies them to a feasibility study of hippocampal avoidance in rodent whole-brain radiotherapy.
As an alternative material to lead, a novel 3D-printable tungsten-composite ABS plastic, GMASS, was tested to create precisely-shaped blocks. Film studies show virtually all primary radiation at 225 kVp can be attenuated by GMASS blocks of 0.5cm thickness. A state-of-the-art software, BlockGen, was used to create custom hippocampus-shaped blocks from medical image data, for any possible axial treatment field arrangement. A custom 3D printed bite block was developed to immobilize and position a supine rat for optimal hippocampal conformity. An immobilized rat CT with digitally-inserted blocks was imported into the SmART-Plan Monte-Carlo simulation software to determine the optimal beam arrangement. Protocols with 4 and 7 equally-spaced fields were considered as viable treatment options, featuring improved hippocampal conformity and whole-brain coverage when compared to prior lateral-opposed protocols. Custom rodent-morphic PRESAGE dosimeters were developed to accurately reflect these treatment scenarios, and a 3D dosimetry study was performed to confirm the SmART-Plan simulations. Measured doses indicate significant hippocampal sparing and moderate whole-brain coverage.
Resumo:
Este artículo presenta la construcción de un instrumento para monitorizar la frecuencia cardíaca (FC), caracterizado por el bajo coste material de su producción. Para verificar la aplicabilidad del Fonocardiograma (FCG) se tomó la FC de nueve (9) sujetos experimentales con a través de dos sistemas: el FCG y el monitor de FC de la marca Polar inc. (Finlandia) modelo RS 800 Cx HR. A continuación, se compraron los resultados. A las nueve (9) personas (4 hombres y 5 mujeres) investigadas se les midió la FC en posición sentada y en posición supina (Zuttin, R. S., Moreno, M. A., César, M. C., Martins, L. E. B., Catai, A. M., & Silva, E., 2008) durante 5 minutos (Vanderlei, L.C.M., Silva, R.A., Pastre, C.M., Azevedo, F.M. & Godoy, M.F., 2008). Se obtuvo una correlación de r = 0,982 para la posición supina y de r = 0,794 para la posición sentada, ambas con p <0,05. Se conseja la construcción de este instrumento para la enseñanza y el aprendizaje de la monitorización de la FC, así como su importancia como método didáctico para la comprensión de la auto-regulación de los ritmos internos.
Resumo:
Este artículo presenta la construcción de un instrumento para monitorizar la frecuencia cardíaca (FC), caracterizado por el bajo coste material de su producción. Para verificar la aplicabilidad del Fonocardiograma (FCG) se tomó la FC de nueve (9) sujetos experimentales con a través de dos sistemas: el FCG y el monitor de FC de la marca Polar inc. (Finlandia) modelo RS 800 Cx HR. A continuación, se compraron los resultados. A las nueve (9) personas (4 hombres y 5 mujeres) investigadas se les midió la FC en posición sentada y en posición supina (Zuttin, R. S., Moreno, M. A., César, M. C., Martins, L. E. B., Catai, A. M., & Silva, E., 2008) durante 5 minutos (Vanderlei, L.C.M., Silva, R.A., Pastre, C.M., Azevedo, F.M. & Godoy, M.F., 2008). Se obtuvo una correlación de r = 0,982 para la posición supina y de r = 0,794 para la posición sentada, ambas con p <0,05. Se conseja la construcción de este instrumento para la enseñanza y el aprendizaje de la monitorización de la FC, así como su importancia como método didáctico para la comprensión de la auto-regulación de los ritmos internos.
Resumo:
Introduction Quantitative and accurate measurements of fat and muscle in the body are important for prevention and diagnosis of diseases related to obesity and muscle degeneration. Manually segmenting muscle and fat compartments in MR body-images is laborious and time-consuming, hindering implementation in large cohorts. In the present study, the feasibility and success-rate of a Dixon-based MR scan followed by an intensity-normalised, non-rigid, multi-atlas based segmentation was investigated in a cohort of 3,000 subjects. Materials and Methods 3,000 participants in the in-depth phenotyping arm of the UK Biobank imaging study underwent a comprehensive MR examination. All subjects were scanned using a 1.5 T MR-scanner with the dual-echo Dixon Vibe protocol, covering neck to knees. Subjects were scanned with six slabs in supine position, without localizer. Automated body composition analysis was performed using the AMRA Profiler™ system, to segment and quantify visceral adipose tissue (VAT), abdominal subcutaneous adipose tissue (ASAT) and thigh muscles. Technical quality assurance was performed and a standard set of acceptance/rejection criteria was established. Descriptive statistics were calculated for all volume measurements and quality assurance metrics. Results Of the 3,000 subjects, 2,995 (99.83%) were analysable for body fat, 2,828 (94.27%) were analysable when body fat and one thigh was included, and 2,775 (92.50%) were fully analysable for body fat and both thigh muscles. Reasons for not being able to analyse datasets were mainly due to missing slabs in the acquisition, or patient positioned so that large parts of the volume was outside of the field-of-view. Discussion and Conclusions In conclusion, this study showed that the rapid UK Biobank MR-protocol was well tolerated by most subjects and sufficiently robust to achieve very high success-rate for body composition analysis. This research has been conducted using the UK Biobank Resource.
Resumo:
Trata-se de uma revisão bibliográfica que objetivou relacionar as medidas educativas para a promoção da integridade da pele em idosos com as Cartas de Promoção da Saúde. Realizou-se a busca nas bases de dados CINAHL, SCOPUS, LILACS e COCHRANE, nos portais CAPES e BVS e na biblioteca PUBMED, mediante a aplicação dos descritores Health Education; Skin e Aged. Os resultados dos 7 artigos analisados apontaram como principais medidas educativas: inspeção diária da pele, cuidados com calçados e com os pés, uso regular de protetor solar e mudanças de decúbito. Essas medidas estavam relacionadas com as seguintes Cartas de Promoção da Saúde: Ottawa, Declaração de Santafé de Bogotá e Declaração de Jacarta. Conclui-se que as medidas educativas, baseadas nas Cartas, são de grande relevância para a criação de uma cultura de saúde, com enfoque na população e no indivíduo como agentes executores imprescindíveis para o alcance da promoção da saúde
Resumo:
Early identification of spontaneous pneumomediastinum in an Emergency Department is possible with thoracic ultrasound. We report two cases of spontaneous pneumomediastinum, diagnosed in a 26-year old man with chronic asthma and a 19-year old athlete, and discuss the role of thoracic US alongside conventional X-ray and thoracic CT in emergency medicine. The patients were transferred to an Emergency Department, where conservative treatment produced a good outcome. The greater sensitivity and specificity of thoracic US over conventional supine X-ray in the detection of occult pneumothorax is ever more appreciated. However, training in the diagnosis of pneumomediastinum is required.
Resumo:
An 85-year-old male was hospitalized because of deterioration of his general condition and infection of the tracheostoma. He had had laryngectomy, bilateral neck dissection and radiation therapy for a laryngeal carcinoma 5 years earlier. Despite a good recovery, he could not get up because of a new onset of postural symptoms (dizziness, lightheadedness, collapse). Late onset of baroreflex failure and autonomic nervous system failure were diagnosed. Volatility of blood pressure (supine hypertension, upright hypotension) was treated with NaCl supplement during the day and a short-acting antihypertensive (clonidine) at night. With this regimen, the patient could walk without support.
Resumo:
From May 15th to 30th and 15th to 30th September 2015 took place the fifth and sixth excavation campaign at the Castellazzo of Monte Iato. The presence of 15 participants made it possible to deepen the research significantly and ex-pand the surface area of investigation. It is completely emptied a room already identified in previous campaigns and provided new information about the relationship with the existing cemetery. Part of a burial in a supine position was destroyed by the installation of wall 20. Traces of another turret projecting from the walls have been discovered in the east and another section of the inner walls (15) was fully exposed. A gate, between two towers, is the first entry traced so far, on the north-eastern side of the plateau. The archaeological materials found confirm the characteristics and type of construction. Being a military camp of ephemeral nature, although active at least 30 years, objects such as arrowheads and crossbow quarrels, knives, buckles and harnesses for horses have been found. One of the environments has been interpreted as an area where gaming took place because of the presence of four dice in ivory, glasses and different coins, in addition to the greater extent than the other environments found. Among the findings are reported a glass weight with a cufic inscription dated to the mid-twelfth century and two bronze coins dated in 15th centu-ry.
Resumo:
Trata-se de uma revisão bibliográfica que objetivou relacionar as medidas educativas para a promoção da integridade da pele em idosos com as Cartas de Promoção da Saúde. Realizou-se a busca nas bases de dados CINAHL, SCOPUS, LILACS e COCHRANE, nos portais CAPES e BVS e na biblioteca PUBMED, mediante a aplicação dos descritores Health Education; Skin e Aged. Os resultados dos 7 artigos analisados apontaram como principais medidas educativas: inspeção diária da pele, cuidados com calçados e com os pés, uso regular de protetor solar e mudanças de decúbito. Essas medidas estavam relacionadas com as seguintes Cartas de Promoção da Saúde: Ottawa, Declaração de Santafé de Bogotá e Declaração de Jacarta. Conclui-se que as medidas educativas, baseadas nas Cartas, são de grande relevância para a criação de uma cultura de saúde, com enfoque na população e no indivíduo como agentes executores imprescindíveis para o alcance da promoção da saúde
Resumo:
The benefits of prone position ventilation are well demonstrated in the severe forms of acute respiratory distress syndrome, but not in the milder forms. We investigated the effects of prone position on arterial blood gases, lung inflammation, and histology in an experimental mild acute lung injury (ALI) model. ALI was induced in Wistar rats by intraperitoneal Escherichia coli lipopolysaccharide (LPS, 5 mg/kg). After 24 h, the animals with PaO2/FIO2 between 200 and 300 mmHg were randomized into 2 groups: prone position (n = 6) and supine position (n = 6). Both groups were compared with a control group (n = 5) that was ventilated in the supine position. All of the groups were ventilated for 1 h with volume-controlled ventilation mode (tidal volume = 6 ml/kg, respiratory rate = 80 breaths/min, positive end-expiratory pressure = 5 cmH2O, inspired oxygen fraction = 1). Significantly higher lung injury scores were observed in the LPS-supine group compared to the LPS-prone and control groups (0.32 ± 0.03; 0.17 ± 0.03 and 0.13 ± 0.04, respectively) (p < 0.001), mainly due to a higher neutrophil infiltration level in the interstitial space and more proteinaceous debris that filled the airspaces. Similar differences were observed when the gravity-dependent lung regions and non-dependent lung regions were analyzed separately (p < 0.05). The BAL neutrophil content was also higher in the LPS-supine group compared to the LPS-prone and control groups (p < 0.05). There were no significant differences in the wet/dry ratio and gas exchange levels. In this experimental extrapulmonary mild ALI model, prone position ventilation for 1 h, when compared with supine position ventilation, was associated with lower lung inflammation and injury.
Resumo:
AIMS: The present is a retrospective evaluation of acute genito-urinary (GU) and gastro-intestinal (GI) toxicity, in addition to biochemical recurrence rate in 57 prostate cancer patients treated at our Institution with ultra-hypofractionated RT (UHRT) schedule. METHODS: From January 2021 to December 2022 we have treated 57 patients with prostate cancer, using an UHRT scheme of 5-fractions every other day for a total dose delivered of 36.25 Gy, according to the PACE-B trial treatment schedule. Good urinary function, assessed by International Prostate Symptom Score (IPSS), were required. The simulation CT scans were acquired in supine position and fused with MRI for CTVs definition for every patient. Each treatment was performed by Accuray's TomoTherapy with daily IGRT. The evaluation of the set-up was very restrictive before daily treatment delivery. RESULTS: According to RTOG toxicity scale, the acute GU toxicity at 3 months from RT, GU toxicity was G0 for 30 patients (52.6%), G1 for 26 (45.6%) and G2 for one only (1.75%); rectal toxicity was G0 for 56 patients (98.25%) and G1 for one only (1.75%). The median follow-up (FU) was 9 months (2-24 months). In the following FU months, we observed progressively lower urinary and rectal toxicity, except for one patient who showed G2 GU toxicity at 12 months. All but one patient had a progressive PSA value decrease. CONCLUSIONS: In our experience, UHRT appears to be safe and well tolerated even without the use of rectal spacer devices. A longer FU is necessary to evaluate late toxicity and disease control rate.