978 resultados para Somatosensory response detection


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A liquid phase blocking ELISA (LPB-ELISA) was developed for the detection and measurement of antibodies against infectious bronchitis virus (IBV). The purified and nonpurified virus used as antigen, the capture and detector antibodies, and the chicken hyperimmune sera were prepared and standardized for this purpose. A total of 156 sera from vaccinated and 100 from specific pathogen-free chickens with no recorded contact with the virus were tested. The respective serum titers obtained in the serum neutralization test (SNT) were compared with those obtained in the LPB-ELISA. There was a high correlation (r2 = 0.8926) between the two tests. The LPB-ELISA represents a single test suitable for the rapid detection of antibodies against bronchitis virus in chicken sera, with good sensitivity (88%), specificity (100%) and agreement (95.31%).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the indirect immunoperoxidase virus neutralization (IPVN) and mouse neutralization test (MNT) to detect antibodies against rabies virus from vaccinated dogs and cattle. The IPVN was set up for the ability to measure 0.5 International Units/ml (IU) of antibody required by the World Health Organization and the Office International des Epizooties as the minimum response for proof of rabies immunization. IPVN was developed and standardized in chicken embryo related (CER) cell line when 141 dog and 110 cattle sera were applied by serial five-fold dilutions (1:5, 1:25, 1:125) as well as the positive and negative reference controls, all added in four adjacent wells, of 96-well microplates. A 50 µl amount of CVS32 strain dilution containing 50-200 TCID50/ml was mixed to each serum dilution, and after 90 min 50 µl of 3 x 10(5) cells/mlcell suspension added to each well. After five days of incubation, the monolayers were fixed and the IPVN test performed. The correlation coefficient between the MNT and IPVN performed in CER cells was r = 0.9949 for dog sera (n = 100) and r = 0.9307 for cattle sera (n = 99), as well as good specificity (94.7%), sensitivity (87.5%), and agreement (96.6%) were also obtained. IPVN technique can adequately identify vaccinated and unvaccinated animals, even from low-responding vaccinated animals, with the advantage of low cost and faster then MNT standard test.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conjugated polymers have been subject of great interest in the recent literature from both fundamental point of view and applied science perspective. Among the several types of conjugated polymers used in recent investigations, polythiophene and its derivatives have attracted considerable attention over the past 20 years due to their high mobility and other remarkable solid-state properties. They have potential applications in many fields, such as microelectronic devices, catalysts, organic field-effect transistors, chemical sensors, and biosensors. They have been studied as gas and volatile organic compounds (VOCs) sensors using different principles or transduction techniques, such as optical absorption, conductivity, and capacitance measurements. In this work, we report on the fabrication of gas sensors based on a conducting polymer on an interdigitated gold electrode. We use as active layer of the sensor a polythiophene derivative: poly (3-hexylthiophene) (P3HT) and analyzed its conductivity as response for exposure to dynamic flow of saturated vapors of six VOCs [n-hexane, toluene, chloroform, dichloromethane, methanol, and tetrahydrofuran (THE)]. Different responses were obtained upon exposure to all VOCs, THF gave the higher response while methanol the lower response. The influence of moisture on the measurements was also evaluated. (C) 2010 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Langmuir films of a tetracarboxylic perylene derivative and polypyrrole display condensed surface pressure isotherms that are shifted when Cu2+ ions are added to the ultrapure water subphase. These films were transferred onto interdigitated gold electrodes leading to Y-type Langmuir-Blodgett (LB) films. The electrodes modified with 5-layer LB films were immersed into a flask with ultrapure water and water containing Cu2+ ions at concentrations ranging from mM to muM. Impedance measurements indicated a distinct electrical response for the two types of films. Although the materials chosen have no specificity for ionic metals, they can be combined for detecting trace levels of Cu2+, which may be exploited in water quality monitoring. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Biosensors for determination of carbamates in vegetables based on five different cholinesterases as biorecognition elements and a screen-printed electrode system as an amperometric transducer were developed. Measurements were simply performed by dropping solutions (either sample or substrate) directly on the biosensor. The response of biosensors to selected carbamates (aldicarb, carbaryl, carbofuran, methomyl and propoxur) was characterized. The performance was evaluated on extracts of potatoes and carrots, the results from the AChE biosensor and a standard HPLC procedure were compared. Finally, the biosensor was used for the direct analysis of vegetable juices without any pretreatment steps. In this case, 10 mu g/L levels of added carbofuran and propoxur were reliably identified. The whole procedure takes less than 20 min including 10 min incubation with samples. The concentrations of carbamates determined with biosensor agreed well for carbofuran. Lower response was observed for propoxur.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Minidosimeters of L-alanine and 2-methylalanine (2MA) were prepared and tested as potential candidates for small radiation field dosimetry. To quantify the free radicals created by radiation a K-Band (24 GHz) EPR spectrometer was used. X-rays provided by a 6 MV clinical linear accelerator were used to irradiate the minidosimeters in the dose range of 0.5-30 Gy. The dose-response curves for both radiation sensitive materials displayed a good linear behavior in the dose range indicated with 2MA being more radiation sensitive than L-alanine. Moreover, 2MA showed a smaller LLD (lower limit detection) value. The proposed system minidosimeter/K-Band spectrometer was able to detect 10 Gy EPR spectra with good signal-to-noise ratio (S/N). The overall uncertainty indicates that this system shows a good performance for the detection of dose values of 20 Gy and above, which are dose values typically used in radiosurgery treatments. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sporothrix schenckii is the etiologic agent of sporotrichosis, a mycosis of world-wide distribution more commonly occurring in tropical regions. The immunological mechanisms involved in the prevention and control of sporotrichosis are not fully understood but apparently include both the humoral and cellular responses. In the present investigation, cellular immunity was evaluated by in vivo and in vitro tests in mice infected with yeast-like forms of S. schenckii. The disease developed systemically and cellular immunity was evaluated for a period of 10 weeks. The soluble antigen utilized in the tests was prepared from yeast form of the fungus through the sonication (20 min: 10 sonications at 50 W at 2-min intervals). Delayed hypersensitivity and lymphocyte transformation tests showed that the cellular immune response was depressed between the 4th and 6th week of infection when the animals were challenged with the soluble fungal antigen. This depression frequently indicates worsening of the disease, with greater involvement of the host. This is a promising field of research for a better understanding of the pathogeny of this mycosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The malate dehydrogenase (MDH) and ascorbate oxidase were immobilized independently, onto silanized controlled porous silica and packed in a tygon tube. The reactors were inserted in the flow system, and the malic acid was determined by measurement of NADH produced by enzymatic reaction. The NADH was reoxidized in a wall jet cell that consisted of spectrographic graphite, Ag/AgCl, KCl(sat), and steel needle as work, reference, and counter electrodes, respectively. The current intensities were measured at 390 mV. The malate calibration curve shows a linear range from 5.0 x 10(-6) to 1.0 x 10(-4) molL(-1), the lifetime was 40 analyses, after that a decrease of 20% on the response is observed. Three different citric juices were analyzed and a good correlation between the proposed method and spectrophotometric commercial kit were obtained.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simultaneous method for the trace determination of acidic, neutral herbicides and their transformation products in estuarine waters has been developed through an on-line solid-phase extraction method followed by liquid chromatography with diode array and mass spectrometric detection. An atmospheric pressure chemical ionization (APCI) interface was used in the negative ionization mode after optimization of the main APCI parameters. Limits of detection ranged from 0.1 to 0.02 ng/ml for 50 mi of acidified estuarine waters preconcentrated into polymeric precolumns and using time-scheduled selected ion monitoring mode. Two degradation products of the acidic herbicides (4-chloro-2-methylphenol and 2,4-dichlorophenol) did not show good signal response using APCI-MS at the concentration studied due to the higher fragmentor voltage needed for their determination For molinate and the major degradation product of propanil, 3,4-dichloroaniline, positive ion mode was needed for APCI-MS detection. The proposed method was applied to the determination of herbicides in drainage waters from rice fields of the Delta del Ebro (Spain). During the S-month monitoring of the herbicides, 8-hydroxybentazone and 4-chloro-2-methylphenoxyacetic acid were successively found in those samples. (C) 2000 Elsevier B.V. B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objectives of the present study were to evaluate factors associated with estrous synchronization responses and pregnancy per insemination (P/AI) in Bos indicus beef cows submitted to progesterone-based fixed-time artificial insemination (FTAI) protocols. A total of 2388 cows (1869 Nellore and 519 crossbred Nellore x Angus) from 10 commercial farms were evaluated to determine the relationships among breed, body condition score (BCS) on the first day of the FTAI protocol, the occurrence of estrus between progesterone device removal and FTAI and diameter of largest ovarian follicle (LF) at FTAI on estrous synchronization responses and P/AI. Cows (n=412 primiparous; 1976 multiparous) received an intravaginal device containing progesterone or an ear implant containing norgestomet (a progestin), and an injection of estradiol at the beginning of the estrous synchronization protocol. Body condition was scored using a 1-5 scale on the first day of the FTAI protocol and at 30-60 days postpartum. Females received 300IU of equine chorionic gonadotropin (eCG) and PGF(2 alpha) on the day the progesterone device/implant was removed and were inseminated 48-60h later. At insemination, cows (n=2388) were submitted to an ultrasonographic exam to determine the diameter of the LF. Follicles were classified into four categories based on mean and standard deviation (SD) of the LF (LF1 = two SD below the mean; LF2 = mean minus one SD; LF3 = mean plus one SD; LF4 = two SD above the mean). Ovulation rate was determined in a subset of cows (n=813) by three consecutive ultrasonographic exams: (1) at time of progesterone device/implant removal, (2) at time of FTAI and (3) 48 h after FTAI. Ovulation was defined as the disappearance of a large follicle (>= 8.0 mm) that was previously recorded. Estrus was determined in a subset of the cows (n = 445) by the activation of a detection of estrous patch placed on the tail head on the day of progesterone device/implant removal. Pregnancy was diagnosed 30 days after FTAI. Pregnancy was influenced (P = 0.001) by follicle diameter [LF1 = 27.5% (81/295), LF2 = 46.6% (328/705), LF3 = 57.9% (647/1118), LF4 = 63.3% (171/270)] and the occurrence of estrus [estrus = 67.7% (174/257) and no estrus = 36.2% (68/188)]. Follicle diameter at FTAI influenced ovulation rate [LF1 = 42.5% (34/80), LF2 = 73.9% (161/218), LF3 = 95.8% (407/425), LF4 = 97.8% (88/90)], the occurrence of estrus [LF1 = 54.8% (51/93), LF2 = 33.6% (43/128), LF3 = 68.9% (126/183), LF4 = 90.2% (37/41)] and P/AI among cows that had ovulations [LF1 =32.4% (11/34), LF2 = 50.3% (81/161), LF3 = 60.0% (244/407), LF4 = 68.2% (60/88)]. Improving estrous responses between progesterone device withdrawal and FTAI and increasing the diameter of the LF at FTAI may be important aspects to achieve improved estrous synchronization responses and P/AI following progesterone/progestin and estradiol based FTAI protocols in suckled Bos indicus cows. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The surface properties of boron-doped nanocrystalline diamond films treated with H(2) plasma was investigated in regard to their electrochemical response for phenol oxidation. The surface of these films is relatively flat formed by crystallites with sizes of about 40 nm. X-ray photoelectron spectroscopy analyses showed that electrode surface has a high amount of C-H bonds. This behavior is in agreement with Mott-Schottky plot measurements concerning the flat band potential that presented a value as expected for hydrogenated diamond surface. This electrode presented the phenol detection limit of 0.08 mg L(-1) for low phenol concentrations from 40 to 250 mu mol L(-1).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)