627 resultados para Silicone hydrogel contact lenses
Resumo:
The total protein content and activity of the enzymes glutathione reductase (GR), superoxide dismutase (SOD) and thioredoxin reductase (TrxR) were evaluated in Acidithiobacillus ferrooxidans LR cells maintained in contact with the metal sulfide chalcopyrite for 1 and 10 days. A significant decrease in total protein content was observed in cells maintained for 10 days in the presence of chalcopyrite, suggesting proteolytic breakdown clue to exposure to the metal sulfide. Following 10 clays of contact with chalcopyrite, increases in GR, SOD and TrxR activities were detected, suggesting the formation of reactive oxygen species. After ten clays, there was a fivefold increase in GR activity, of which, isoenzyme IV represented approximately 82% of the total. An increase in Fe-SOD activity following ten days exposure to chalcopyrite was also determined, as measured on non-denaturing polyacrylamide gels. Also, after 10 days. an approximately 31-fold increase was observed for TrxR activity. The presence of oxidative stress when A. ferrooxidans is in the presence of chalcopyrite could have a negative impact on bioleaching. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
This review reflects the state of the art in study of contact and dynamic phenomena occurring in cold roll forming. The importance of taking these phenomena into account is determined by significant machine time and tooling costs spent on worn out forming rolls replacement and equipment adjustment in cold roll forming. Predictive modelling of the tool wear caused by contact and dynamic phenomena can reduce the production losses in this technological process.
Resumo:
A copolymer of X-hydroxyethyl methacrylate (HEMA) with 2-ethoxy ethyl methacrylate (EEMA) was synthesized and the molecular mobility, free volume, and density properties examined as a function of composition. These properties were correlated with the equilibrium water uptake in order to determine which of the properties were most influential in causing high water sorption, as these materials are suitable candidates for hydrogel systems. It was found that the polar HEMA repeat unit results in a rigid, glassy sample at room temperature due to the high degree of hydrogen bonding between chains whereas high EEMA content leads to rubbery samples with subambient glass transition temperatures. The free volume properties on the molecular scale measured by positron annihilation Lifetime spectroscopy (PALS) showed that higher HEMA content led to smaller, fewer holes and a lower free volume fraction than EEMA. Therefore the high water uptake of HEEMA-containing copolymers is largely related to the high polarity of the HEMA unit compared to EEMA, despite the low content of free volume into which the water can initially diffuse. Trends in density with copolymer composition, as measured on a macroscopic level, differs to that seen by PALS and indicates that the two techniques are measuring different scales of packing. (C) 1998 John Wiley & Sons, Inc.
Resumo:
The otoliths and lenses of the temperate damselfish Parma microlepis (Gunther) (Pomacentridae) showed similar differences in trace-metal profile for selected locations along the coast of New South Wales, Australia. Otoliths and lenses displayed a differential ability to accumulate metals. Metal concentrations were ranked differently in the two structures (e.g. Sr > Ba > Pb > Rb > Hg in otoliths, and Hg > Sr similar or equal to Rb > Pb > Ba in lenses), and where similar metals were accumulated, they were accumulated at vastly different concentrations (e.g. Ba concentrations in otoliths are a thousand-fold greater than in lenses). Analyses of the otoliths and lenses of P. microlepis from locations close to Sydney and up to 100 kill from the city were able to distinguish amongst these locations with respect to a number of metals, namely Ba, Mn and Hg. Multivariate analyses of otolith and lens data gave similar results among locations (agreement was obtained for Ii out of 15 pair-wise comparisons), and differences were attributable to the differential ability of the two structures to accumulate metals such as Mn and Hg. Trace-metal differences between locations were found to coincide with the proximity of sewage (including industrial waste) and petroleum storage facilities to the different locations.
Resumo:
This paper reports a follow-up study to an article on the sensitivity of three tests of speed of information processing to impairment after concussion (Hinton-Bayre, Geffen, BL McFarland, 1997). Group analyses showed that practice effects can obscure the effects of concussion on information processing, thereby making the assessment of functional impairment and recovery after injury unreliable. A Reliable Change Index (RCI) was used to assess individual variations following concussion. It was found that 16 of the 20 concussed professional rugby league players were impaired 1-3 days following injury. It was also demonstrated that 7 players still displayed cognitive deficits at 1-2 weeks, before returning to preseason levels at 3-5 weeks. The RCI permits comparisons between different tests, players, and repeated assessments, thereby providing a quantitative basis for decisions regarding return to play.
Resumo:
We use theoretical and numerical methods to investigate the general pore-fluid flow patterns near geological lenses in hydrodynamic and hydrothermal systems respectively. Analytical solutions have been rigorously derived for the pore-fluid velocity, stream function and excess pore-fluid pressure near a circular lens in a hydrodynamic system. These analytical solutions provide not only a better understanding of the physics behind the problem, but also a valuable benchmark solution for validating any numerical method. Since a geological lens is surrounded by a medium of large extent in nature and the finite element method is efficient at modelling only media of finite size, the determination of the size of the computational domain of a finite element model, which is often overlooked by numerical analysts, is very important in order to ensure both the efficiency of the method and the accuracy of the numerical solution obtained. To highlight this issue, we use the derived analytical solutions to deduce a rigorous mathematical formula for designing the computational domain size of a finite element model. The proposed mathematical formula has indicated that, no matter how fine the mesh or how high the order of elements, the desired accuracy of a finite element solution for pore-fluid flow near a geological lens cannot be achieved unless the size of the finite element model is determined appropriately. Once the finite element computational model has been appropriately designed and validated in a hydrodynamic system, it is used to examine general pore-fluid flow patterns near geological lenses in hydrothermal systems. Some interesting conclusions on the behaviour of geological lenses in hydrodynamic and hydrothermal systems have been reached through the analytical and numerical analyses carried out in this paper.
Resumo:
The eye lenses of Parma microlepis from the rocky barrens of Sydney (New South Wales, Australia) were found to contain Ba, Hg, Rb, and Sr at concentrations above the quantitative detection limits of solution-based inductively-coupled plasma-mass spectrometry (ICP-MS). Lenses were separated into the hard central nucleus and the softer surrounding cortex. Nuclei contained lower (equal for Ba) concentrations of these metals. Biochemical analysis of the protein composition of these lenses revealed differences in the ratio of gamma-crystallin to beta-crystallin in the lens nucleus and cortex. These changes were shown to be attributable both to protein degradation and changes in protein synthesis as fish age. Such changes may lead to the loss of sequestered metals from older cell layers, or change the affinity of new layers for particular trace metals. Differential binding affinities of these crystallins may, therefore, partially account for trace-metal differences observed in the lens nucleus and cortex.
Resumo:
To help improve services for parents with psychotic disorders, patients with such disorders in three treatment agencies in Queensland, Australia, were surveyed about whether they were parents, how much contact they had with their offspring, and who provided assistance with child care. Of the 342 individuals with psychotic disorders mho participated in the study, 124 were parents. Forty-eight parents in the study had children under age 16, and 20 of these parents (42 percent) had their children living with them. Most parents relied on relatives or friends for assistance with child care. Barriers to child care services identified by parents were inability to pay, lack of local services, and fear of losing custody of children.
Resumo:
Most Western countries have, for some time, provided income support and/or taxation relief to parents with children in their care. The significant amount of research into the costs of children to couple and sole parent households has been important in assessing and developing family support policies. Changing societal expectations about the level of involvement of fathers in child rearing activities has highlighted the need to understand the costs facing usually male non-resident parents in having contact with their children. The budget standards methodology is used in this paper to estimate the costs for non-resident parents exercising regular contact with their children. Costs of contact are found to be high. For contact with one child for 20 per cent of the year, costs of contact represent about 40 per cent of the costs of that same child in an intact couple household with a medium income and more than half of the costs of that child in a household with low income. Household infrastructure and transportation is the reason for high costs. One implication of this finding is that the total cost of children substantially increases when parents separate. The article discusses some policy implications of these findings. This research is of relevance to social security, taxation, family law and child support policies and administration.
Resumo:
The combined approach of the molecular-kinetic and hydrodynamic theories for description of the motion of three-phase gas-liquid-solid contact lines has been examined using the Wilhelmy plate method. The whole dynamic meniscus has been divided into molecular, hydrodynamic, and static-like regions. The Young-Laplace equation and the molecular-kinetic and hydrodynamic dewetting theories have been applied to describe the meniscus profiles and contact angle. The dissipative forces accompanying the dynamic dewetting have also been investigated. The experiments with a Wilhelmy plate made from an acrylic polymer sheet were carried out using a computerized apparatus for contact angle analysis (OCA 20, DataPhysics, Germany). The extrapolated dynamic contact angle versus velocity of the three-phase contact line for Milli-Q water and 5 x 10(-4) M SDBS solution was experimentally obtained and compared with the combined MHD models with low and moderate Reynolds numbers. The models predict similar results for the extrapolated contact angle. SDBS decreases the equilibrium contact angle and increases the molecular jumping length but does not affect the molecular frequency significantly. The hydrodynamic deformation of the meniscus, viscous dissipation, and friction were also influenced by the SDBS surfactant. (c) 2005 Elsevier Inc. All rights reserved.
Resumo:
Purpose: To evaluate wavefront performance and modulation transfer function (MTF) in the human eye aft er the implantation of diffractive or refractive multifocal intraocular lenses (IOLs). Materials and Methods: This was a prospective, interventional, comparative, nonrandomized clinical study. Uncorrected distance and near visual acuity, and wavefront analysis including MTF curves (iTrace aberrometer, Tracey Technologies, Houston, TX, USA) were measured in 60 patients aft er bilateral IOL implantation with 6 months of follow-up. Forty eyes received the diffractive ReSTOR (Alcon), 40 eyes received the refractive ReZoom (Advanced Medical Optics) and 40 eyes, the Tecnis ZM900 (Advanced Medical Optics). The comparison of MTF and aberration between the intraocular lenses was performed using analysis of variance (ANOVA), followed by the Dunn test when necessary. Results: The mean uncorrected distance visual acuity was similar in all three groups of multifocal IOLs. The ReSTOR group provided better uncorrected near visual acuity than the ReZoom group (P < 0.001), but similar to the Tecnis group. Spherical aberration was significantly higher in the ReZoom group (P = 0.007). Similar MTF curves were found for the aspheric multifocal IOL Tecnis and the spheric multifocal IOL ReSTOR, and both performed better than the multifocal IOL ReZoom in a 5 mm pupil (P < 0.001 at all spatial frequencies). Conclusions: Diffractive IOLs studied presented similar MTF curves for a 5 mm pupil diameter. Both diffractive IOLs showed similar spherical aberration, which was significantly better with the full-diffractive IOL Tecnis than with the refractive IOL ReZoom.
Resumo:
Allergic contact dermatitis is the consequence of an immune reaction mediated by T cells against low molecular weight chemicals known as haptens. It is a common condition that occurs in all races and age groups and affects the quality of life of those who present it. The immunological mechanism of this disease has been reviewed in recent decades with significant advance in its understanding. The metabolism and pathway of the haptens as well as the activation and mechanism of action of the cells responsible for both the immune reaction and its completion are discussed in this article.
Resumo:
PURPOSE: To determine whether implantation of an intraocular lens (IOL) with an aspheric surface (Akreos AO, Bausch & Lomb Inc) results in reduced ocular aberrations (spherical aberration) and improved Strehl ratio and modulation transfer function (MTF) after cataract surgery. METHODS: In an intraindividual, randomized, double-masked, prospective study of 50 eyes (25 patients) with bilateral cataract, an IOL with modified anterior and posterior surfaces (Akreos AO) was implanted in one eye and a biconvex IOL with spherical surfaces (Akreos Fit, Bausch & Lomb Inc) implanted in the fellow eye. Ocular aberrations, Strehl ratio, and MTF curve with 4.5-, 5.0-, and 6.0-mm pupils were measured with a NIDEK OPD-Scan dynamic retinoscopy aberrometer 3 months after surgery. Uncorrected and corrected distance visual acuity (UDVA and CDVA, respectively) were also measured. RESULTS: No statistically significant difference was noted between eyes in postoperative UDVA and CDVA at 1 month. At 3 months, the Akreos AO IOL group obtained statistically significant lower values of higher order and spherical aberrations with 4.5-, 5.0-, and 6.0-mm pupil diameters than the Akreos Fit IOL group (P<.05). The value of Strehl ratio was statistically significantly higher in eyes with the Akreos AO IOL for 4.5- and 6.0-mm pupils (P<.05). The MTF curve was better in the Akreos AO IOL group in 4.5-, 5.0-, and 6.0-mm pupils (P<.05). CONCLUSIONS: The aspheric Akreos AO IOL induced significantly less spherical aberration than the Akreos Fit IOL for 4.5-, 5.0-, and 6.0-mm pupils. Modulation transfer function and Strehl ratio were also better in eyes implanted with the Akreos AO IOL than the Akreos Fit. [J Refract Surg. 2011;27(4):287-292.] doi:10.3928/1081597X-20100714-01
Resumo:
PURPOSE To compare reading ability after cataract surgery and bilateral implantation of multifocal intraocular lenses (IOLs) with a +3 00 diopter (D) addition (add) or a +4 00 D add SETTING Department of Ophthalmology, University of Sao Paulo, Sao Paulo, Brazil DESIGN Prospective comparative study METHODS Patients scheduled for cataract surgery were randomly assigned to bilateral implantation of an aspheric AcrySof ReSTOR multifocal IOL with a +3 00 diopter (D) addition (add) or a +4 00 D add The reading speed, critical print size, and reading acuity were measured binocularly with best correction using MNREAD acuity charts 6 months after surgery Patients were tested with the chart at the best patient-preferred reading distance and at 40 cm Binocular uncorrected and best distance-corrected visual acuities at far and near were also measured RESULTS The study enrolled 32 patients At the best reading distance the results were similar between the 2 IOL groups in all reading parameters When tested at 40 cm, reading speed at all print sizes from 03 to 00 (all P< 001), critical print size (P< 001) and reading acuity (P = 014) were statistically significantly better in the +3 00 D IOL group than in the +4 00 DIOL group Uncorrected and corrected visual acuities at far and near were similar between the 2 groups CONCLUSION Although the 2 IOL groups had similar performance in reading parameters, patients had to adjust to their best reading distance The +3 00 D IOL performed better than the +4 00 D IOL at 40 cm
Resumo:
Purpose: Most groups have reported disappointing results with autoaugmentation or detrusor myectomy for low capacity/compliance neuropathic bladders. Failure may be due to an ischemic diverticulum or mucosal shrinkage. We investigated whether a Silimed (R) silicone balloon placed in the bladder after autoaugmentation could prevent these problems, improving surgical results. Materials and Methods: We compared the results of standard bladder autoaugmentation in 12 children (group 1) with those in 10 (group 2) who underwent the same surgery using a bladder conformer. The conformer was a silicone balloon filled with saline that remained in the bladder for 2 weeks. All patients had a neuropathic bladder with poor capacity and compliance, resulting in urinary leakage between catheterizations. Preoperative and postoperative evaluation included a voiding diary, ultrasound, voiding cystourethrogram and urodynamics. Results: In group 1 only 1 patient became dry, 4 had little improvement in continence, 4 remained unchanged and 3 became worse. In group 2, 6 patients (60%) become continent without medication, 2 (20%) become continent with oxybutynin and 2 remained unchanged. Bladder capacity and compliance did not change significantly in group 1. However, in group 2 capacity changed from a mean of 140 to 240 ml and mean +/- SD compliance increased from 15.6 +/- 16.8 to 34.3 +/- 22.8 ml/cm H(2)O (p = 0.02). Conclusions: The inflatable balloon improved our long-term results of bladder auto-augmentation. A larger series may be necessary to confirm procedure efficacy and safety.