960 resultados para STRICTLY POSITIVE REAL MATRICES
Resumo:
For a typical non-symmetrical system with two parallel three phase transmission lines, modal transformation is applied using some examples of single real transformation matrices. These examples are applied searching an adequate single real transformation matrix to two parallel three phase transmission line systems. The analyses are started with the eigenvector and eigenvalue studies, using Clarke's transformation or linear combinations of Clarke's elements. The Z C and parameters are analyzed for the case that presents the smallest errors between the exact eigenvalues and the single real transformation matrix application results. The single real transformation determined for this case is based on Clarke's matrix and its main characteristic is the use of a unique homopolar reference. So, the homopolar mode becomes a connector mode between the two three-phase circuits of the analyzed system. ©2005 IEEE.
Resumo:
The objective of this paper is to show an alternative representation in time domain of a non-transposed three-phase transmission line decomposed in its exact modes by using two transformation matrices. The first matrix is Clarke's matrix that is real, frequency independent, easily represented in computational transient programs (EMTP) and separates the line into Quasi-modes α, β and zero. After that, Quasi-modes a and zero are decomposed into their exact modes by using a modal transformation matrix whose elements can be synthesized in time domain through standard curve-fitting techniques. The main advantage of this alternative representation is to reduce the processing time because a frequency dependent modal transformation matrix of a three-phase line has nine elements to be represented in time domain while a modal transformation matrix of a two-phase line has only four elements. This paper shows modal decomposition process and eigenvectors of a non-transposed three-phase line with a vertical symmetry plane whose nominal voltage is 440 kV and line length is 500 km. ©2006 IEEE.
Resumo:
Clarke's matrix has been used as an eigenvector matrix for transposed three-phase transmission lines and it can be applied as a phase-mode transformation matrix for transposed cases. Considering untransposed three-phase transmission lines, Clarke's matrix is not an exact eigenvector matrix. In this case, the errors related to the diagonal elements of the Z and Y matrices can be considered negligible, if these diagonal elements are compared to the exact elements in domain mode. The mentioned comparisons are performed based on the error and frequency scan analyses. From these analyses and considering untransposed asymmetrical three-phase transmission lines, a correction procedure is determined searching for better results from the Clarke's matrix use as a phase-mode transformation matrix. Using the Clarke's matrix, the relative errors of the eigenvalue matrix elements can be considered negligible and the relative values of the off-diagonal elements are significant. Applying the corrected transformation matrices, the relative values of the off-diagonal elements are decreased. The comparisons among the results of these analyses show that the homopolar mode is more sensitive to the frequency influence than the two other modes related to three-phase lines. © 2006 IEEE.
Resumo:
The objective of this paper is to show an alternative representation in time domain of a non-transposed three-phase transmission line decomposed in its exact modes by using two transformation matrices. The first matrix is Clarke's matrix that is real, frequency independent, easily represented in computational transient programs (EMTP) and separates the line into Quasi-modes α, β and zero. After that, Quasi-modes α and zero are decomposed into their exact modes by using a modal transformation matrix whose elements can be synthesized in time domain through standard curve-fitting techniques. The main advantage of this alternative representation is to reduce the processing time because a frequency dependent modal transformation matrix of a three-phase line has nine elements to be represented in time domain while a modal transformation matrix of a two-phase line has only four elements. This paper shows modal decomposition process and eigenvectors of a non-transposed three-phase line with a vertical symmetry plane whose nominal voltage is 440 kV and line length is 500 km. © 2006 IEEE.
Resumo:
Includes bibliography
Resumo:
We study polynomials which satisfy the same recurrence relation as the Szego{double acute} polynomials, however, with the restriction that the (reflection) coefficients in the recurrence are larger than one in modulus. Para-orthogonal polynomials that follow from these Szego{double acute} polynomials are also considered. With positive values for the reflection coefficients, zeros of the Szego{double acute} polynomials, para-orthogonal polynomials and associated quadrature rules are also studied. Finally, again with positive values for the reflection coefficients, interlacing properties of the Szego{double acute} polynomials and polynomials arising from canonical spectral transformations are obtained. © 2012 American Mathematical Society.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Much has been said about possible symptoms of Dutch disease in Colombia in the wake of a marked upsurge in commodity prices and the significant real appreciation of the national currency. This paper examines whether the real effective exchange rate had an impact on industry during the period 2000-2010. Specifically, it evaluates the effect of the appreciation of the real exchange rate on the value added of 63 industrial sectors in Colombia using the Arellano and Bond (1991) generalized method of moments (gmm) estimator. Overall, our results confirm a negative relationship between real exchange rate appreciation and industry. The analysis showed that real exchange rate appreciation had a significant impact on the value added of 21 sectors: a negative effect for 18 sectors and a positive effect for 3 sectors.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Os vírus linfotrópicos de células T humanas, quando integrados ao genoma da célula hospedeira, provírus, têm como marcador de replicação seu DNA proviral. A carga proviral parece ser um importante fator no desenvolvimento de patologias associadas a estes retrovírus. Neste estudo foi desenvolvida uma metodologia para quantificação absoluta da carga proviral dos HTLV-1 e HTLV-2 através da PCR em tempo real. Cinqüenta e três amostras de doadores de sangue com teste de ELISA reagente foram submetidas à metodologia, que utilizou o sistema TaqMan® para três seqüências alvo: HTLV-1, HTLV-2 e albumina. A quantificação proviral absoluta foi determinada através da proporção relativa entre o genoma do HTLV e o genoma da célula hospedeira, levando em consideração o número de leucócitos. O método apresentado é sensível (215 cópias/mL), prático e simples para quantificação proviral, além de eficiente e adequado para confirmação e discriminação da infecção pelos tipos virais.
Resumo:
O HCV é um vírus esférico, que apresenta um genoma de RNA com polaridade positiva. Atualmente está classificado na família Flaviviridae num gênero separado que é o Hepacivirus, apresenta cerca de 9,4 Kb constituído por uma única e longa fase de leitura aberta (ORF) que compreende quase todo o genoma. Apresenta duas regiões não traduzidas nas extremidades 5' e 3' denominadas 5' UTR e 3' UTR. A poli proteína precursora é clivada em dez proteínas, resultando em proteínas virais estruturais e proteínas nãoestruturais. É um vírus de transmissão preferencialmente parenteral, com distribuição universal, cujo diagnóstico é feito na grande maioria de maneira acidental, sendo atualmente utilizado os testes sorológico e molecular. Este trabalho tem como objetivo comparar o teste sorológico de imunoensaio enzimático (ELISA) e a reação em cadeia da polimerase (PCR) na ocasião da seleção de pré-doadores de sangue. Foram feitos testes de detecção do vírus C por PCR em 290 amostras com resultado positivo ou indeterminado para o teste ELISA. A análise dos resultados revelou que as amostras com testes ELISA positivo/PCR positivo e ELISA positivo/PCR negativo são duas amostras diferentes e independentes (p=0,0006). Esta diferença pode ser supostamente devido a resposta imune diferenciada nas amostras que apresentaram resultado no teste PCR positivas. Esperava-se que houvesse correlação entre os resultados do DO/Cutoff (ELISA) e carga viral (PCR) como o que ocorre em outros vírus como o HIV, no entanto os resultados apresentaram-se totalmente dispersos (R2=0,025), confirmando a não correlação entre os dois testes: ELISA e PCR para o vírus C.