569 resultados para SILICONE


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The process of epidermal differentiation involves proliferation, differentiation, migration and maturation of keratinocytes to form an impermeable barrier against water loss and outside environment. It is controlled by highly balanced regulatory machinery, involving many molecules that are still under investigation.Homeobox proteins are involved in body patterning and morphogenesis of organs and are studied as potentially good candidates to regulate this process. In the first project we investigated the role of a protein named HOP which belongs to a group of homeobox proteins. Even if HOP is a small protein almost completely composed of the homeodomain and without DNA binding capacity, it is considered as transcriptional regulator in different tissues. HOP interacts with serum response factor (SRF) and histone deacetylase type 2 (HDAC2). By microarray analysis we found that HOP expression increases in cultured human primary keratinocytes (NHK) which undergo calcium-induced differentiation. HOP protein was localized in granular layer of the epidermis of healthy individuals. Lack of HOP was demonstrated in psoriatic lesions, whereas a strong expression was demonstrated in the lesional skin of patients affected with lichen planus (LP). Since LP is characterized by hypergranulosis while psoriatic lesions by progressive lack of the granular layer, the obtained data indicated that HOP might have a potential function in granular layer of epidermis. To investigate HOP function, we inhibited its expression by using HOP specific StealthRNAi and we overexpressed HOP using lentiviral vectors in differentiating NHK. The conclusion of both experiments indicated that HOP positively regulates the expression of late differentiation markers, such as profilaggrin, loricrin and transglutaminase 1. The in vitro data were next confirmed in vivo using HOP knockout mouse model.The second part of my study involved analysis of mechanisms underlying the pathogenesis of epidermolytic hyperkeratosis (EHK). EHK is a genetic disorder characterized by erythema, skin blistering, keratinocyte hyperproliferation and hyperkeratosis. EHK is caused by mutations in keratin 1 or 10 (K1, K10) which are major structural proteins of differentiated keratinocytes and participate in the cellular scaffold formation. To investigate how the structural proteins carrying mutations alter cellular signaling, we established an in vitro model for EHK by overexpression of one of the most common K10 mutations reported so far (K10R156H), in primary human keratinocytes. In order to mimic the in vivo situation, mutated keratinocytes growing on silicone membranes were subjected to mechanical stretch. We observed strong collapse of KIF in K10R156H keratinocytes when subjected to stretch for 30 minutes. Our data demonstrated stronger activation of p38, a member of MAPK stress signaling pathways, in K10R156H when compared to control cells. We demonstrated also that K10R156H keratinocytes showed an induction of TNF-α and RANTES release in response to stretch.Taken together these studies characterize a novel regulator of epidermal differentiation - HOP and demonstrate new aspects implicated in the pathogenesis of EHK.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Most pavement contraction joint seals in Iowa, in general, have been performing in less than a satisfactory manner. The effective life of the seals, in maintaining a watertight joint, has been only from two to five years. In search of improvements, research was proposed to evaluate preformed neoprene joint seals. The performance of those seals was to be compared mainly with the hot poured rubberized asphalt sealants and cold applied silicone sealants or other sealants commonly used at the time this research began. Joint designs and methods of sawing were also investigated. All evaluations were done in new portland cement concrete (PCC) pavements. Three projects were initially selected and each included a research section of joint sealing. Some additional sites were later added for evaluation. Several joint sealants were evaluated at each research site. The various sites included high, medium and low levels of traffic. Evaluations were done over a five-year period. Neoprene joint seals provided better performance than hot or cold field formed joints.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A utilização de gases inertes como fumigantes no controle de pragas é uma alternativa ao uso de fosfina. O objetivo deste trabalho foi avaliar a eficiência de uma atmosfera com CO2 no controle de Rhyzoperta dominica (Fabr.) (Coleoptera: Bostrichidae) em grãos de trigo armazenado. O trabalho constou de cinco concentrações de CO2 (0, 30 , 40, 50 e 60%, completadas com N2), três períodos de exposição (5, 10, 15 dias), três populações de R. dominica (Fabr.) (Coleoptera: Bostrichidae) (Campo Mourão, PR, Sete Lagoas, MG e Santa Rosa, RS) e sete fases de desenvolvimento do inseto (ovo, larva de 1º, 2º, 3º e 4º ínstar, pupa e adulto) com três repetições. As diferentes fases da R. dominica foram acondicionadas em tecido organza e levadas para câmaras de expurgo de 200 litros com 75% deste volume repletos de grãos. As câmaras foram vedadas com borracha de silicone para garantir a hermeticidade. Após a vedação das câmaras injetavam-se os gases contendo diferentes teores de CO2. Os resultados mostraram que todos os teores de CO2 causaram 100% de mortalidade de adultos das três populações nos três períodos de exposição utilizados. Em pupas a mortalidade atingiu 100% no teor de 60% de CO2 para as três populações no período de 15 dias de exposição; porém, todos os teores de CO2 utilizados no período de 15 dias de exposição causaram 100% de mortalidade das pupas da população de Santa Rosa. Para o adequado controle de larvas de diferentes ínstares são necessários teores de CO2 iguais ou acima de 50%. Nos períodos de 10 e 15 dias de exposição, todos os teores de CO2 causaram 100% de mortalidade dos ovos das três populações avaliadas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Many strategies have been investigated to provide an ideal substitute to treat a nerve gap injury. Initially, silicone conduits were used and more recently conduits fabricated from natural materials such as poly-3-hydroxybutyrate (PHB) showed good results but still have their limitations. Surgically, a new concept optimising harvested autologous nerve graft has been introduced as the single fascicle method. It has been shown that a single fascicle repair of nerve grafting is successful. We investigated a new approach using a PHB strip seeded with Schwann cells to mimic a small nerve fascicle. Schwann cells were attached to the PHB strip using diluted fibrin glue and used to bridge a 10-mm sciatic nerve gap in rats. Comparison was made with a group using conventional PHB conduit tubes filled with Schwann cells and fibrin glue. After 2 weeks, the nerve samples were harvested and investigated for axonal and Schwann cell markers. PGP9.5 immunohistochemistry showed a superior nerve regeneration distance in the PHB strip group versus the PHB tube group (> 10 mm, crossed versus 3.17+/- 0.32 mm respectively, P<0.05) as well as superior Schwann cell intrusion (S100 staining) from proximal (> 10 mm, crossed versus 3.40+/- 0.36 mm, P<0.01) and distal (> 10 mm, crossed versus 2.91+/- 0.31 mm, P<0.001) ends. These findings suggest a significant advantage of a strip in rapidly connecting a nerve gap lesion and imply that single fascicle nerve grafting is advantageous for nerve repair in rats.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Methods of improving highway safety are of major concern to everyone who is involved in the planning, development and construction of improvements of our vast highway network. Other major concerns are the conservation of our rapidly disappearing sources of energy and quality building materials. This research is devoted to further exploration of a process which will: 1. help preserve higher quality aggregates; and, 2. improve the frictional characteristics and surface texture of asphalt pavement surfaces. Sprinkle treatment of asphalt concrete pavement surfaces with a non-polishing aggregate, a procedure which was developed in Europe, is one method which has shown promise in accomplishing the above listed objectives. This research seeks to explore the feasibility and cost effectiveness of using standard asphalt mixtures of local, less expensive aggregates for surface courses followed by a surface sprinkle treatment of a hard, durable, non-polishing layer of precoated chips to produce a durable, non-skid pavement surface for safe highway travel. Three standard mixture types are being evaluated for aggregate retention characteristics and six sprinkle aggregates are being evaluated for durability, polishing and friction characteristics. In addition, measurements of the surface texture by the silicone putty method are being made. Another feature of this research is the evaluation of a rubberized asphalt material called Overflex MS as a crack filler. It has been reported that the material could be beneficial in reducing reflective cracking. The project was begun in July of 1978 and was completed in August. A review made in the spring of 1979 indicates very satisfactory performance. It was determined from slide photos taken after construction and again in the spring that aggregate retention was very good. However, many cracks had reflected indicating that the Overflex MS had not been effective. Follow up friction test results and texture analysis were also very good. The results of these tests are shown in Appendix A.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chronic atrial fibrillation affects millions of people worldwide. Its surgical treatment often fails to restore the transport function of the atrium. This study first introduces the concept of an atrial assist device (AAD) to restore the pump function of the atrium. The AAD is developed to be totally implantable in the human body with a transcutaneous energy transfer system to recharge the implanted battery. The ADD consists of a motorless pump based on artificial muscle technology, positioned on the external surface of the atrium to compress it and restore its muscular activity. A bench model reproduces the function of a fibrillating atrium to assess the circulatory support that this pump can provide. Atripump (Nanopowers SA, Switzerland) is a dome-shaped silicone-coated nitinol actuator 5 mm high, sutured on the external surface of the atrium. A pacemaker-like control unit drives the actuator that compresses the atrium, providing the mechanical support to the blood circulation. Electrical characteristics: the system is composed of one actuator that needs a minimal tension of 15 V and has a maximum current of 1.5 A with a 50% duty cycle. The implantable rechargeable battery is made of a cell having the following specifications: nominal tension of a cell: 4.1 V, tension after 90% of discharge: 3.5 V, nominal capacity of a cell: 163 mA h. The bench model consists of an open circuit made of latex bladder 60 mm in diameter filled with water. The bladder is connected to a vertically positioned tube that is filled to different levels, reproducing changes in cardiac preload. The Atripump is placed on the outer surface of the bladder. Pressure, volume and temperature changes were recorded. The contraction rate was 1 Hz with a power supply of 12 V, 400 mA for 200 ms. Preload ranged from 15 to 21 cm H(2)O. Maximal silicone membrane temperature was 55 degrees C and maximal temperature of the liquid environment was 35 degrees C. The pump produced a maximal work of 16 x 10(-3) J. Maximal volume pumped was 492 ml min(-1). This artificial muscle pump is compact, follows the Starling law and reproduces the hemodynamic performances of a normal atrium. It could represent a new tool to restore the atrial kick in persistent atrial fibrillation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Laparoscopic enucleation for neuroendocrine pancreatic tumors has become a feasible technique, with a reported incidence of pancreatic fistula ranging from 13 to 29 %.1 (-) 3 This report describes the first successful case of laparoscopic pancreatic enucleation with resection of the main pancreatic duct followed by end-to-end anastomosis. METHODS: A 41-year-old woman was admitted to the authors' hospital for repeated syncope. Hypoglycemia also was noted. A contrast-enhanced computed tomography examination showed a highly enhanced tumor measuring 22 mm in diameter on the ventral side of the pancreatic body adjacent to the main pancreatic duct. The patient's blood insulin level was elevated, and her diagnosis was determined to be pancreatic insulinoma. Laparoscopic pancreatic enucleation was performed. Approximately 2 cm of the main pancreatic duct was segmentally resected, and a short stent (Silicone tube: Silastic, Dow Corning Corporation, Midland, MI) was inserted. The direct anastomosis of the main pancreatic duct was performed using four separate sutures with an absorbable monofilament (6-0 PDS). RESULTS: The operation time was 166 min, and the estimated blood loss was 100 mL. The postoperative course was uneventful, and the patient was discharged from hospital on postoperative day 7. The pathologic findings showed a well-differentiated insulinoma and a negative surgical margin. A computed tomography examination performed 1 month after the operation showed a successful anastomosis with a patent main pancreatic duct. CONCLUSIONS: Laparoscopic segmental resection of the main pancreatic duct and end-to-end anastomosis can be performed safely with the insertion of a short stent. This technique also can be used for a central pancreatectomy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to assess the safety and efficacy of stenting in upper airway reconstructions for benign laryngotracheal stenosis (LTS) with a newly designed prosthesis, the LT-Mold?. The LT-Mold and its proper use during open surgery and endoscopy are described, and the experience gathered from a prospectively collected database on 65 patients treated for complex LTS or severe aspiration is reported. This series is compared to the results of other stenting methods. All patients were available for evaluation. In all but one case, the prosthesis was removed at the end of the study. The new prosthesis did not induce any stent-related trauma to the supraglottis, glottis and subglottis. Before adding a distal round-shaped silicone cap to the LT-Mold, granulation tissue was usually seen at the stent-mucosal interface at the tracheostoma level. In 14 cases, there has been a spontaneous extrusion of the prosthesis through the mouth; this problem was solved by fixing the prosthesis through the reinforced portion of the prosthesis at the cap level and by adding one fixation stitch in the supraglottis. We have to document the loss of the silicone cap in three cases. This problem was resolved by designing a new prototype with an integrated cap, glued with a slow hardening silicone glue. Fifty-four (83 %) of 65 patients were decannulated after a mean duration of stenting of 3 months (range 1-12 months). The mean follow-up after decannulation was 23 months (range 1 month to 10 years). The experience gathered with the LT-Mold shows that long-term stenting for complex LTS is safely achieved when the prosthesis is used with its distal integrated silicone cap. The softness and smoothness of the prosthesis with a round-shaped configuration of both extremities help avoid ulceration and granulation tissue formation in the reconstructed airway. Adequate fixation is mandatory to avoid extrusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This randomized controlled pilot study examined the effects of a silicone net dressing (Mepitel(®)) and a monofilament polyamide woven dressing (SurfaSoft(®)) on the rate of epithelialisation and epidermal maturation, pain, and ease of dressing removal on paediatric donor sites treated with epithelial cell suspension (ReCell(®)). Fifteen children (1-15 years) admitted for acute or reconstructive burns procedures in a tertiary referral hospital in Australia were randomly assigned to the experimental group, Mepitel(®) (n=8) and to the control group, SurfaSoft(®) (n=7). All donor sites were treated with ReCell(®) and covered with the assigned dressing. Measurements of rate of epithelialisation and epidermal maturation, pain, and ease of dressing removal were recorded every two days until the wound was healed. Results showed that there was no difference in the rate of epidermal maturation between the two groups. Less pain and force to remove the dressing was shown in the Mepitel(®) group when compared to SurfaSoft(®). The rate of epithelialisation was found to be an unreliable measure. Although additional research is required to support the results of this study, these results suggest that Mepitel's(®) pliable, self-adhesive and atraumatic properties may improve healing of ReCell(®) treated donor sites with less pain at dressing changes. This pilot study provides a strong base for further research in this area.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Concern about premature joint sealant failures occurring in portland cement concrete (PCC) pavements gave impetus to initiating this research project. Eight sealants, including three silicone sealants, were evaluated and tested in the lab as well as incorporated in approximately 700 joints in the field and evaluated over a six-year period. The preliminary data show that among the silicone sealants, Dow Corning 888 rated the highest. However, this was rated third overall behind the W. R. Meadows cold-applied Sof Seal and Crafco #231 hot pour sealants. The W. R. Meadows and Crafco sealants cost approximately 30 percent and 50 percent less to furnish and place than the Dow Corning product. All joint sealants will continue to be evaluated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La résection par voie endoscopique transnasale de tumeurs envahissant la base du crâne antérieure a été récemment décrite. Cette chirurgie requiert une connaissance précise des repères anatomiques endoscopiques afin réduire le risque de complications vasculaires et neurologiques.¦Nous avons réalisé une étude anatomique endoscopique sur 6 têtes dont 3 injectées avec du silicone coloré. Les repères anatomiques pour les abords de 3 régions d'importance clinique ont été étudiés. Les repères pour l'abord de l'apex orbitaire sont le recessus carotidien latéral, l'empreinte du nerf optique, « l'optic strut » et le V2. Leurs rapports avec le canal optique, l'artère carotide interne et les fentes orbitaires supérieures et inférieures sont décrits. Les repères pour l'abord de l'apex pétreux sont le V2 et le nerf vidien qui permettent repérer la portion intrapétreuse de l'artère carotide interne. Les repères pour l'abord de la fosse ptérygomaxillaire sont le V2 et le foramen rotundum, l'artère et le trou sphénopalatins et l'artère maxillaire interne.¦Cette nouvelle approche permettant d'aborder des lésions médianes et paramédianes ouvre de nouvelles perspectives pour des équipes de neurochirurgiens et d'ORL. Ces voies d'abords s'appliquent aussi bien à des résections décompressives à but palliatif qu'à l'exérèse de tumeurs benignes et malignes, bien que les résultats à long terme doivent encore être validés pour cette dernière indication.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is an ongoing drive towards improvements and achieving success in effective and long term sealing of portland cement concrete pavement contraction joints. A variety of joint sealing products and procedures have been applied in Iowa in search of improvements in seal performance. Hot poured rubberized asphalt products were mainly used for sealing all joints in earlier years for highways. In the 1980s, silicone sealant products were becoming popular, especially for the major highways. As a high level of sealant performance was not achieved from silicones in Iowa conditions, other sealing products were tried. Preformed neoprene compression seals are being tried as a substitution for silicone sealants. Due to high costs of materials and installation with neoprene seals, the search for improvements through other joint sealing products and procedures continued. An agreement was made with Phoenix, North America, Inc., to provide and install preformed Ethylene Propylene Diene Monomer (EPDM) compression joint seals. The research site was a 600 ft (183 m) test section of northbound I-29 in Pottawattamie County, Iowa. Seal installation was done August 20, 1992. Seal performance has been good over the past seven years and the seals are still showing no significant signs of decreasing performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A conductometric micromethod combined with image analysis system has been developed allowing to determine the CO2 production within 'two-dimensional' tissues, i.e., flat and thin cell layers or epithelial sheets. The preparation was mounted into an airtight chamber separated in two compartments by a thin silicone membrane permeable to gases. The lower compartment contained the nutritive medium and the preparation. The upper compartment and a conductivity measuring capillary connected in series were perfused with a solution of Ba(OH)2. The CO2 produced by the tissue precipitated as BaCO3 and the resulting decrease of electrical conductivity was linearly related to the total CO2 production. In addition, the pattern of CO2 production was directly observable as the BaCO3 crystals formed upon the silicone membrane over the regions which produced CO2. The spatial distribution of the crystals was quantified by video image processing and the regional CO2 production evaluated with a spatial resolution of 100 microns. This new microtechnique was originally developed to study the CO2 production in the early chick blastoderm which is a disc 1-5 cells thick. At the stage of young neurula the CO2 production was found to be 235 +/- 37 nmol.h-1 (mean +/- SD; n = 10) per blastoderm and large variations of local CO2 production were detected from one region to another (from 0.6 to 6.5 nmol.h-1.mm-2). These results indicate a high metabolic and functional differentiation of cells within the blastoderm. The possible applications and improvements of such a microtechnique are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Bench evaluation of the hydrodynamic behavior of venous cannulas is a valuable technique for the analysis of their performance during cardiopulmonary bypass (CPB). The aim of this study was to investigate the effect of the internal diameter of the extracorporeal connecting tube of venous cannulas on flow rate (Q), pressure drop (delta P), and cannula resistance (delta P/Q²) values, using a computer assisted test bench.¦METHODS: An in vitro circuit was set up with silicone tubing between the test cannula encased in a movable reservoir, and a static reservoir. The delta P, defined as the difference between the drainage pressure and the preload pressure, was measured using high-fidelity Millar pressure transducers. Q was measured using an ultrasonic flowmeter. Data display and data recording were controlled using virtual instruments in a stepwise fashion.¦RESULTS: The 27 F smartcanula® with a 9 mm connecting tube diameter showed 17% less resistance compared to that with an 8 mm connecting tube diameter. Q values were 7.22±0.1 and 7.81±0.04 L/min for cannulas with 8 mm and 9 mm connecting tube diameters, respectively. The delta P/Q² ratio values were 72% lower for the Medtronic cannula with a 9 mm connecting tube diameter compared to that with an 8 mm connecting tube diameter. Q values for the Medtronic cannula were 3.94±0.23 and 6.58±0.04 L/min with 8 mm and 9 mm connecting tube diameters, respectively. The 27 F smartcanula® showed 13% more flow rate compared to the 28 F Medtronic cannula using the unpaired Student t-test (p<0.0001).¦CONCLUSIONS: Our results demonstrated that Q was increased but delta P and delta P/Q² values were significantly decreased when the connecting tube diameter was increased for venous cannulas. The connecting tube diameter significantly affected the resistance to liquid flow through the cannula. Smartcanulas® outperform Medtronic cannulas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Työn tavoitteena oli tutkia HSR(High Speed Release)-mittausmenetelmän käyttämistä tarralaminaattiprosessin ohjauksessa UPM Raflatacissa. Nykyisin käytössä olevaan LSR(Low Speed Release)-menetelmään verrattuna HSR-menetelmä kuvaa paremmin tarralaminaatin jatkojalostuksessa sekä etiketöinnissä tapahtuvaa irrotustyötä. Lisäksi työssä tutkittiin irrotusnopeuden vaikutusta HSR-arvoon. Työn kirjallisuusosassa perehdyttiin tarralaminaatin rakenteeseensekä valmistusprosessiin. Koska silikonin valinnalla on merkittävä vaikutus tarralaminaatin releasearvoon, kirjallisessa osassa syvennytään tarkastelemaan tarralaminaatin valmistuksessa käytettyjä silikoneja sekänäiden rakennetta. Kirjallisuusosassa on myös käsitelty muita releasetasoon vaikuttavia tekijöitä. Työn kokeellisessa osassa oli tarkoituksena tutkia HSR-mittausmenetelmän käytettävyyttä tarralaminaatin prosessinohjauksessa. Tätä tutkittiin selvittämällä nykyisin käytössä olevan LSR-menetelmän sekä HSR-menetelmän välistä korreloituvuutta. Mikäli näidenvälillä olisi korreloituvuutta, voitaisiin prosessinohjauksessa ajatella siirtyvän HSR-mittaukseen. Korrelaatiota näiden kahden menetelmän välille ei kuitenkaan löydetty. Työssä tutkittiin myös irrotusnopeuden vaikutusta tuotteen HSR-arvoon. Testeihin valittiin useita eri tuotteita useilta tuotantolaitoksilta. Kaikilla näillä tuotteilla releasearvo kasvoi irrotusnopeutta lisättäessä. Lisäksi työssä määritettiin uudet HSR-spesifikaatiot tietyille tuotteille. Kaikille UPM Raflatacin tuotteille on määritetty LSRspesifikaatiot, HSR-spesifikaatiot on asetettu vain tietyille tuotteille.