925 resultados para Running Lamps.
Resumo:
INTRODUCTION AND HYPOTHESIS The prevalence of female stress urinary incontinence is high, and young adults are also affected, including athletes, especially those involved in "high-impact" sports. To date there have been almost no studies testing pelvic floor muscle (PFM) activity during dynamic functional whole body movements. The aim of this study was the description and reliability test of PFM activity and time variables during running. METHODS A prospective cross-sectional study including ten healthy female subjects was designed with the focus on the intra-session test-retest reliability of PFM activity and time variables during running derived from electromyography (EMG) and accelerometry. RESULTS Thirteen variables were identified based on ten steps of each subject: Six EMG variables showed good reliability (ICC 0.906-0.942) and seven time variables did not show good reliability (ICC 0.113-0.731). Time variables (e.g. time difference between heel strike and maximal acceleration of vaginal accelerator) showed low reliability. However, relevant PFM EMG variables during running (e.g., pre-activation, minimal and maximal activity) could be identified and showed good reliability. CONCLUSION Further adaptations regarding measurement methods should be tested to gain better control of the kinetics and kinematics of the EMG probe and accelerometers. To our knowledge this is the first study to test the reliability of PFM activity and time variables during dynamic functional whole body movements. More knowledge of PFM activity and time variables may help to provide a deeper insight into physical strain with high force impacts and important functional reflexive contraction patterns of PFM to maintain or to restore continence.
Resumo:
PURPOSE Stress urinary incontinence (SUI) affects women of all ages including young athletes, especially those involved in high-impact sports. To date, hardly any studies are available testing pelvic floor muscles (PFM) during sports activities. The aim of this study was the description and reliability test of six PFM electromyography (EMG) variables during three different running speeds. The secondary objective was to evaluate whether there was a speed-dependent difference between the PFM activity variables. METHODS This trial was designed as an exploratory and reliability study including ten young healthy female subjects to characterize PFM pre-activity and reflex activity during running at 7, 9 and 11 km/h. Six variables for each running speed, averaged over ten steps per subject, were presented descriptively, tested regarding their reliability (Friedman, ICC, SEM, MD) and speed difference (Friedman). RESULTS PFM EMG variables varied between 67.6 and 106.1 %EMG, showed no systematic error and were low for SEM and MD using the single value model. Applying the average model over ten steps, ICC (3,k) were >0.75 and SEM and MD about 50 % lower than for the single value model. Activity was found to be highest in 11 km/h. CONCLUSION EMG variables showed excellent ICC and very low SEM and MD. Further studies should investigate inter-session reliability and PFM reactivity patterns of SUI patients using the average over ten steps for each variable as it showed very high ICC and very low SEM and MD. Subsequently, longer running distances and other high-impact sports disciplines could be studied.
Resumo:
With the advent of the Universal Technical Standard for Solar Home Systems, procedures to test the compliance of SHS fluorescent lamps with the standard have been developed. Definition of the laboratory testing procedures is a necessary step in any lamp quality assurance procedure. Particular attention has been paid to test simplicity and to affordability, in order to facilitate local application of the testing procedures, for example by the organisations which carry out electrification programmes. The set of test procedures has been applied to a representative collection of 42 lamps from many different countries, directly acquired in the current photovoltaic rural electrification market. Tests apply to: lamp resistance under normal operating conditions; lamp reliability under extreme conditions; under abnormal conditions; and lamp luminosity. Results are discussed and some recommendations for updating the relevant standard are given. The selected technical standard, together with the proposed testing procedures, form the basis of a complete quality assurance tool that can be applied locally in normal electrical laboratories. Full testing of a lamp requires less than one month, which is very reasonable on the context of quality assurance programmes
Resumo:
This paper proposes a way to quantify the emissions of mercury (Hg) and CO2 associated with the manufacture and operation of compact fluorescent lamps with integrated ballasts (CFLis), as well as the economic cost of using them under different operating cycles. The main purpose of this paper is to find simple criteria for reducing the polluting emissions under consideration and the economic cost of CFLi to a minimum. A lifetime model is proposed that allows the emissions and costs to be described as a function of degradation from turning CFLi on and their continuous operation. An idealized model of a CFLi is defined that combines characteristics stated by different manufacturers. In addition, two CFLi models representing poor-quality products are analyzed. It was found that the emissions and costs per unit of time of operation of the CFLi depend linearly on the number of times per unit of time it is turned on and the time of continuous operation. The optimal conditions (lowest emissions and costs) depend on the place of manufacture, the place of operation and the quality of the components of the lamp/ballast. Finally, it was also found that for each lamp, there are intervals when it is turned off during which emissions of pollutants and costs are identical regardless of how often the lamp is turned on or the time it remains on. For CO2 emissions, the lamp must be off up to 5 minutes; for the cost, up to 7 minutes and for Hg emissions, up to 43 minutes. It is advisable not to turn on a CFLi sooner than 43 minutes from the last time it was turned off.
Resumo:
Reducing energy consumption and eliminating wastage are among the main goals of the European Union (EU) [2]. In order to satisfy all challenges arising from the Kyoto protocol, improving energy efficiency is a very important factor to take into account. There is significant potential for reducing consumption with cost-effective measures. Some studies show that 40% of our energy is consumed in buildings, and the EU has introduced legislation that aims to ensure that less energy is consumed in this way in the future.
Resumo:
The interest in LED lighting has been growing recently due to the high efficacy, lifelime and ruggedness that this technology offers. However the key element to guarantee those parameters with these new electronic devices is to keep under control the working temperature of the semiconductor crystal. This paper propases a LED lamp design that fulfils the requ irements of a PV lighting systems, whose main quality criteria is reliability. It uses directly as a power supply a non·stabilized constant voltage source, as batteries. An electronic control architecture is used to regulate the current applied to the LEO matri)( according to their temperature and the voltage output value of the batteries with two pulse modulation signals (PWM) signals. The first one connects and disconnects the LEOs to the power supply and the second one connects and disconnects several emitters to the electric circuit changing its overall impedance. A prototype of the LEO lamp has been implemented and tested at different temperaturas and battery voltages.
Resumo:
With the consolidation of the new solid state lighting LEOs devices, te5t1n9 the compliance 01 lamps based on this technology lor Solar Home Systems (SHS) have been analyzed. The definition of the laboratory procedures to be used with final products 15 a necessary step in arder to be able to assure the quality of the lamps prior to be installed [1]. As well as with CFL technology. particular attention has been given to simplicity and technical affordability in arder to facilitate the implementation of the test with basie and simple laboratory too15 even on the same SHS electrification program locations. The block of test procedures has been applied to a set of 14 low-cost lamps. They apply to lamp resistance, reliability and performance under normal, extreme and abnormal operating conditions as a simple but complete quality meter tool 01 any LEO bulb.
Resumo:
The number of breast cancer survivors increases every year, thanks to the development of new treatments and screening techniques. However, patients present with numerous side effects that may affect their quality of life. Exercise has been demostrated to reduce some of these side effects, but in spite of this, few breast cancer patientes know and follow the exercise recommendations needed to remain healthy. In this review, we describe the differente breast cancer treatments and the related side effects and implications of exercise in relation to these. We propose that exercise could be and integrative complementary intervention to improve physiological, physical and psychological factors that affect survival and quality of life of these patients. For that reason, the main objective of this review is to provide a general overview of exercise benefits in breast cancer patients and recommendations of how to design exercise interventions in patients with different side effects.
Resumo:
Running increases neurogenesis in the dentate gyrus of the hippocampus, a brain structure that is important for memory function. Consequently, spatial learning and long-term potentiation (LTP) were tested in groups of mice housed either with a running wheel (runners) or under standard conditions (controls). Mice were injected with bromodeoxyuridine to label dividing cells and trained in the Morris water maze. LTP was studied in the dentate gyrus and area CA1 in hippocampal slices from these mice. Running improved water maze performance, increased bromodeoxyuridine-positive cell numbers, and selectively enhanced dentate gyrus LTP. Our results indicate that physical activity can regulate hippocampal neurogenesis, synaptic plasticity, and learning.
Resumo:
The EU’s Central Asia Strategy approaches its fourth anniversary. In that time the EU has placed its relationship with Central Asia on a more structured footing. Although progress has been made in building dialogue and in furthering engagement, the strategy’s limitations are increasingly obvious. This brief argues that the driving force of the EU engagement should be based on a closer link between security and development. Engagement in this broad field should be underpinned by a values based approach that seeks to promote more explicitly reform on human rights, rule of law, governance and democracy. The momentous changes sweeping across the Middle East and North Africa have demonstrated that even the most apparently durable authoritarian regimes are vulnerable to sudden political shocks.