876 resultados para Recall-Precision Curves
Resumo:
Every year a large number of birds die when they collide with windows. The actual number is difficult to ascertain. Previous attempts to estimate bird-window collision rates in Canada relied heavily on a prior citizen-science study that used memory-based surveys. Such an approach to data collection has many potential biases. We built upon this study and its recommendations for future research by creating a citizen-science program that actively searched for collision evidence at houses and apartments for an extended period with the objective to see how standardized approaches to data collection compared with memory recall. Absolute collision estimates as well as relative differences were compared between residence types in the two studies, and we found considerable differences in absolute values for collisions but similar rankings of collision rates between residence types. Collision recall rates in our study (56.5%) were very similar those in the prior 2012 study, where 50.5% of participants remembered a bird colliding with a window at some time in the past. Fatality estimates, however, were 1.4 times higher in the 2012 study than in our study based on standardized searches. Rural houses with a bird feeder consistently had the highest number of collisions. This suggests that memory recall surveys may be a useful tool for understanding the relative importance of different risk factors causing bird-window collisions.
Resumo:
New radiocarbon calibration curves, IntCal04 and Marine04, have been constructed and internationally ratified to replace the terrestrial and marine components of IntCal98. The new calibration data sets extend an additional 2000 yr, from 0-26 cal kyr BP (Before Present, 0 cal. BP = AD 1950), and provide much higher resolution, greater precision, and more detailed structure than IntCal98. For the Marine04 curve, dendrochronologically-dated tree-ring samples, converted with a box diffusion model to marine mixed-layer ages, cover the period from 0-10.5 call kyr BR Beyond 10.5 cal kyr BP, high-resolution marine data become available from foraminifera in varved sediments and U/Th-dated corals. The marine records are corrected with site-specific C-14 reservoir age information to provide a single global marine mixed-layer calibration from 10.5-26.0 cal kyr BR A substantial enhancement relative to IntCal98 is the introduction of a random walk model, which takes into account the uncertainty in both the calendar age and the C-14 age to calculate the underlying calibration curve (Buck and Blackwell, this issue). The marine data sets and calibration curve for marine samples from the surface mixed layer (Marine04) are discussed here. The tree-ring data sets, sources of uncertainty, and regional offsets are presented in detail in a companion paper by Reimer et al. (this issue).
Resumo:
As part of the European Commission (EC)'s revision of the Sewage Sludge Directive and the development of a Biowaste Directive, there was recognition of the difficulty of comparing data from Member States (MSs) because of differences in sampling and analytical procedures. The 'HORIZONTAL' initiative, funded by the EC and MSs, seeks to address these differences in approach and to produce standardised procedures in the form of CEN standards. This article is a preliminary investigation into aspects of the sampling of biosolids, composts and soils to which there is a history of biosolid application. The article provides information on the measurement uncertainty associated with sampling from heaps, large bags and pipes and soils in the landscape under a limited set of conditions, using sampling approaches in space and time and sample numbers based on procedures widely used in the relevant industries and when sampling similar materials. These preliminary results suggest that considerably more information is required before the appropriate sample design, optimum number of samples, number of samples comprising a composite, and temporal and spatial frequency of sampling might be recommended to achieve consistent results of a high level of precision and confidence. (C) 2004 Elsevier Ltd. All rights reserved.
Resumo:
A method is described for the analysis of deuterated and undeuterated alpha-tocopherol in blood components using liquid chromatography coupled to an orthogonal acceleration time-of-flight (TOF) mass spectrometer. Optimal ionisation conditions for undeuterated (d0) and tri- and hexadeuterated (d3 or d6) alpha-tocopherol standards were found with negative ion mode electrospray ionisation. Each species produced an isotopically resolved single ion of exact mass. Calibration curves of pure standards were linear in the range tested (0-1.5 muM, 0-15 pmol injected). For quantification of d0 and d6 in blood components following a standard solvent extraction, a stable-isotope-labelled internal standard (d3-alpha-tocopherol) was employed. To counter matrix ion suppression effects, standard response curves were generated following identical solvent extraction procedures to those of the samples. Within-day and between-day precision were determined for quantification of d0- and d6-labelled alpha-tocopherol in each blood component and both averaged 3-10%. Accuracy was assessed by comparison with a standard high-performance liquid chromatography (HPLC) method, achieving good correlation (r(2) = 0.94), and by spiking with known concentrations of alpha-tocopherol (98% accuracy). Limits of detection and quantification were determined to be 5 and 50 fmol injected, respectively. The assay was used to measure the appearance and disappearance of deuterium-labelled alpha-tocopherol in human blood components following deuterium-labelled (d6) RRR-alpha-tocopheryl acetate ingestion. The new LC/TOFMS method was found to be sensitive, required small sample volumes, was reproducible and robust, and was capable of high throughput when large numbers of samples were generated. Copyright (C) 2003 John Wiley Sons, Ltd.
Resumo:
Previous research demonstrates that dementia of the Alzheimer type (DAT) is characterised by deficits of episodic memory, especially in the acquisition of new material. As well as this deficit in acquisition, some researchers have also argued for a deficit in consolidation in DAT. We examined acquisition and consolidation by measuring the intertrial gained and lost access in DAT, Mild Cognitive Impairment (MCI) and controls. We report findings from a study of clinical data based on assessment of patients using three free recall trials of a word list. We found that both DAT and MCI groups showed a deficit in acquisition and consolidation of items between trials relative to controls. Moreover, the DAT group was significantly impaired relative to the MCI group for both acquisition and consolidation. Correlations within each group showed that there were strong relationships between intertrial measures and standard measures of memory function. Importantly in no group was there a significant correlation between our measures of acquisition and consolidation: we argue that these measures reflect different underlying processes, and the failure to consolidate in DAT and MCI is not related to the deficit in acquisition. Finally, we showed strong correlations between our measure and dementia severity, suggesting that acquisition and consolidation both get worse as the dementia progresses.
Resumo:
In immediate recall tasks, visual recency is substantially enhanced when output interference is low (Cowan, Saults, Elliott, & Moreno, 2002; Craik, 1969) whereas auditory recency remains high even under conditions of high output interference. Ibis auditory advantage has been interpreted in terms of auditory resistance to output interference (e.g., Neath & Surprenant, 2003). In this study the auditory-visual difference at low output interference re-emerged when ceiling effects were accounted for, but only with spoken output. With written responding the auditory advantage remained significantly larger with high than with low output interference. These new data suggest that both superior auditory encoding and modality-specific output interference contribute to the classic auditory-visual modality effect.