912 resultados para RETROGRADE SINUS PERFUSION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Myocardial perfusion quantification by means of Contrast-Enhanced Cardiac Magnetic Resonance images relies on time consuming frame-by-frame manual tracing of regions of interest. In this Thesis, a novel automated technique for myocardial segmentation and non-rigid registration as a basis for perfusion quantification is presented. The proposed technique is based on three steps: reference frame selection, myocardial segmentation and non-rigid registration. In the first step, the reference frame in which both endo- and epicardial segmentation will be performed is chosen. Endocardial segmentation is achieved by means of a statistical region-based level-set technique followed by a curvature-based regularization motion. Epicardial segmentation is achieved by means of an edge-based level-set technique followed again by a regularization motion. To take into account the changes in position, size and shape of myocardium throughout the sequence due to out of plane respiratory motion, a non-rigid registration algorithm is required. The proposed non-rigid registration scheme consists in a novel multiscale extension of the normalized cross-correlation algorithm in combination with level-set methods. The myocardium is then divided into standard segments. Contrast enhancement curves are computed measuring the mean pixel intensity of each segment over time, and perfusion indices are extracted from each curve. The overall approach has been tested on synthetic and real datasets. For validation purposes, the sequences have been manually traced by an experienced interpreter, and contrast enhancement curves as well as perfusion indices have been computed. Comparisons between automatically extracted and manually obtained contours and enhancement curves showed high inter-technique agreement. Comparisons of perfusion indices computed using both approaches against quantitative coronary angiography and visual interpretation demonstrated that the two technique have similar diagnostic accuracy. In conclusion, the proposed technique allows fast, automated and accurate measurement of intra-myocardial contrast dynamics, and may thus address the strong clinical need for quantitative evaluation of myocardial perfusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Perfusion CT imaging of the liver has potential to improve evaluation of tumour angiogenesis. Quantitative parameters can be obtained applying mathematical models to Time Attenuation Curve (TAC). However, there are still some difficulties for an accurate quantification of perfusion parameters due, for example, to algorithms employed, to mathematical model, to patient’s weight and cardiac output and to the acquisition system. In this thesis, new parameters and alternative methodologies about liver perfusion CT are presented in order to investigate the cause of variability of this technique. Firstly analysis were made to assess the variability related to the mathematical model used to compute arterial Blood Flow (BFa) values. Results were obtained implementing algorithms based on “ maximum slope method” and “Dual input one compartment model” . Statistical analysis on simulated data demonstrated that the two methods are not interchangeable. Anyway slope method is always applicable in clinical context. Then variability related to TAC processing in the application of slope method is analyzed. Results compared with manual selection allow to identify the best automatic algorithm to compute BFa. The consistency of a Standardized Perfusion Index (SPV) was evaluated and a simplified calibration procedure was proposed. At the end the quantitative value of perfusion map was analyzed. ROI approach and map approach provide related values of BFa and this means that pixel by pixel algorithm give reliable quantitative results. Also in pixel by pixel approach slope method give better results. In conclusion the development of new automatic algorithms for a consistent computation of BFa and the analysis and definition of simplified technique to compute SPV parameter, represent an improvement in the field of liver perfusion CT analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Questa tesi si propone di innovare lo stato dell’arte dei metodi di analisi dell’eterogeneità in lesioni polmonari attualmente utilizzati, affiancando l’analisi funzionale (emodinamica) a quella morfologica, grazie allo sviluppo di nuove feature specifiche. Grazie alla collaborazione tra il Computer Vision Group (CVG) dell’Università di Bologna e l’Unità Operativa di Radiologia dell’IRCCS-IRST di Meldola (Istituto di Ricovero e Cura a Carattere Scientifico – Istituto Scientifico Romagnolo per lo Studio e la Cura dei Tumori), è stato possibile analizzare un adeguato numero di casi reali di pazienti affetti da lesioni polmonari primitive, effettuando un’analisi dell’eterogeneità sia su sequenze di immagini TC baseline sia contrast-enhanced, consentendo quindi un confronto tra eterogeneità morfologica e funzionale. I risultati ottenuti sono infine discussi sulla base del confronto con le considerazioni di natura clinica effettuate in cieco da due esperti radiologi dell’IRCCS-IRST.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During short-term postural changes, the factors determining the amplitude of intracranial pulse pressure (ICPPA) remain constant, except for cerebrovascular resistance (CVR). Therefore, it may be possible to draw conclusions from the ICPPA onto the cerebrovascular resistance (CVR) and thus the relative change in cerebral perfusion pressure (CPP).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Successful extremity transplantations and replantations have to be performed within 6 h of amputation to avoid irreversible tissue loss. This study investigates ex vivo the technical feasibility and the limb preservation potential of extracorporeal whole blood perfusion in a porcine model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carotid sinus massage (CSM) is commonly used to identify carotid sinus hypersensitivity (CSH) as a possible cause for syncope, especially in older patients. However, CSM itself could provoke classical vasovagal syncope (VVS) in pre disposed subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To describe a method of carrying out apical surgery of a maxillary molar using ultrasonics to create a lateral sinus window into the maxillary sinus and an endoscope to enhance visibility during surgery. SUMMARY: A 37-year-old female patient presented with tenderness to percussion of the maxillary second right molar. Root canal treatment had been undertaken, and the tooth restored with a metal-ceramic crown. Radiological examination revealed an apical radiolucency in close proximity to the maxillary sinus. Apical surgery of the molar was performed through the maxillary sinus, using ultrasonics for the osteotomy, creating a window in the lateral wall of the maxillary sinus. During surgery, the lining of the sinus was exposed and elevated without perforation. The root-end was resected using a round tungsten carbide drill, and the root-end cavity was prepared with ultrasonic retrotips. Root-end filling was accomplished with MTA(®) . An endoscope was used to examine the cut root face, the prepared cavity and the root-end filling. No intraoperative or postoperative complications were observed. At the 12-month follow-up, the tooth had no clinical signs or symptoms, and the radiograph demonstrated progressing resolution of the radiolucency. KEY LEARNING POINTS: When conventional root canal retreatment cannot be performed or has failed, apical surgery may be considered, even in maxillary molars with roots in close proximity to the maxillary sinus. Ultrasonic sinus window preparation allows more control and can minimize perforation of the sinus membrane when compared with conventional rotary drilling techniques. The endoscope enhances visibility during endodontic surgery, thus improving the quality of the case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lung recruitment maneuvers (RMs), used to reopen atelectatic lung units and to improve oxygenation during mechanical ventilation, may result in hemodynamic impairment. We hypothesize that pulmonary arterial hypertension aggravates the consequences of RMs in the splanchnic circulation. Twelve anesthetized pigs underwent laparotomy and prolonged postoperative ventilation. Systemic, regional, and organ blood flows were monitored. After 6 h (= baseline), a recruitment maneuver was performed with sustained inflation of the lungs. Thereafter, the pigs were randomly assigned to group C (control, n = 6) or group E with endotoxin-induced pulmonary arterial hypertension (n = 6). Endotoxemia resulted in a normotensive and hyperdynamic state and a deterioration of the oxygenation index by 33%. The RM was then repeated in both groups. Pulmonary artery pressure increased during lipopolysaccharide infusion from 17 ± 2 mmHg (mean ± SD) to 31 ± 10 mmHg and remained unchanged in controls (P < 0.05). During endotoxemia, RM decreased aortic pulse pressure from 37 ± 14 mmHg to 27 ± 13 mmHg (mean ± SD, P = 0.024). The blood flows of the renal artery, hepatic artery, celiac trunk, superior mesenteric artery, and portal vein decreased to 71% ± 21%, 69% ± 20%, 76% ± 16%, 79% ± 18%, and 81% ± 12%, respectively, of baseline flows before RM (P < 0.05 all). Organ perfusion of kidney cortex, kidney medulla, liver, and jejunal mucosa in group E decreased to 65% ± 19%, 77% ± 13%, 66% ± 26%, and 71% ± 12%, respectively, of baseline flows (P < 0.05 all). The corresponding recovery to at least 90% of baseline regional blood flow and organ perfusion lasted 1 to 5 min. Importantly, the decreases in regional blood flows and organ perfusion and the time to recovery of these flows did not differ from the controls. In conclusion, lipopolysaccharide-induced pulmonary arterial hypertension does not aggravate the RM-induced significant but short-lasting decreases in systemic, regional, and organ blood flows.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Functional magnetic resonance imaging (fMRI) of fluorine-19 allows for the mapping of oxygen partial pressure within perfluorocarbons in the alveolar space (Pao(2)). Theoretically, fMRI-detected Pao(2) can be combined with the Fick principle approach, i.e., a mass balance of oxygen uptake by ventilation and delivery by perfusion, to quantify the ventilation-perfusion ratio (Va/Q) of a lung region: The mixed venous blood and the inspiratory oxygen fraction, which are equal for all lung regions, are measured. In addition, the local expiratory oxygen fraction and the end capillary oxygen content, both of which may differ between the lung regions, are calculated using the fMRI-detected Pao(2). We investigated this approach by numerical simulations and applied it to quantify local Va/Q in the perfluorocarbons during partial liquid ventilation. METHODS: Numerical simulations were performed to analyze the sensitivity of the Va/Q calculation and to compare this approach with another one proposed by Rizi et al. in 2004 (Magn Reson Med 2004;52:65-72). Experimentally, the method was used during partial liquid ventilation in 7 anesthetized pigs. The Pao(2) distribution in intraalveolar perflubron was measured by fluorine-19 MRI. Respiratory gas fractions together with arterial and mixed venous blood samples were taken to quantify oxygen partial pressure and content. Using the Fick principle, the local Va/Q was estimated. The impact of gravity (nondependent versus dependent) of perflubron dose (10 vs 20 mL/kg body weight) and of inspired oxygen fraction (Fio(2)) (0.4-1.0) on Va/Q was examined. RESULTS: In numerical simulations, the Fick principle proved to be appropriate over the Va/Q range from 0.02 to 2.5. Va/Q values were in acceptable agreement with the method published by Rizi et al. In the experimental setting, low mean Va/Q values were found in perflubron (confidence interval [CI] 0.08-0.29 with 20 mL/kg perflubron). At this dose, Va/Q in the nondependent lung was higher (CI 0.18-0.39) than in the dependent lung regions (CI 0.06-0.16; P = 0.006; Student t test). Differences depending on Fio(2) or perflubron dose were, however, small. CONCLUSION: The results show that derivation of Va/Q from local Po(2) measurements using fMRI in perflubron is feasible. The low detected Va/Q suggests that oxygen transport into the perflubron-filled alveolar space is significantly restrained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gene therapy may represent a promising alternative strategy for cardiac muscle regeneration. In vivo electroporation, a physical method of gene transfer, has recently evolved as an efficient method for gene transfer. In the current study, we investigated the efficiency and safety of a protocol involving in vivo electroporation for gene transfer to the beating heart. Adult male rats were anesthetised and the heart exposed through a left thoracotomy. Naked plasmid DNA was injected retrograde into the transiently occluded coronary sinus before the electric pulses were applied. Animals were sacrificed at specific time points and gene expression was detected. Results were compared to the group of animals where no electric pulses were applied. No post-procedure arrhythmia was observed. Left ventricular function was temporarily altered only in the group were high pulses were applied; CK-MB (Creatine kinase) and TNT (Troponin T) were also altered only in this group. Histology showed no signs of toxicity. Gene expression was highest at day one. Our results provide evidence that in vivo electroporation with an optimized protocol is a safe and effective tool for nonviral gene delivery to the beating heart. This method may be promising for clinical settings especially for perioperative gene delivery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: Mechanical ventilation is a cornerstone of ICU treatment. Because of its interaction with blood flow and intra-abdominal pressure, mechanical ventilation has the potential to alter hepato-splanchnic perfusion, abdominal organ function and thereby outcome of the most critically ill patients. RECENT FINDINGS: Mechanical ventilation can alter hepato-splanchnic perfusion, but the effects are minimal (with moderate inspiratory pressures, tidal volumes, and positive end-expiratory pressure levels) or variable (with high ones). Routine nursing procedures may cause repeated episodes of inadequate hepato-splanchnic perfusion in critically ill patients, but an association between perfusion and multiple organ dysfunction cannot yet be determined. Clinical research continues to be challenging as a result of difficulties in measuring hepato-splanchnic blood flow at the bedside. SUMMARY: Mechanical ventilation and attempts to improve oxygenation such as intratracheal suctioning and recruitment maneuvers, may have harmful consequences in patients with already limited cardiovascular reserves or deteriorated intestinal perfusion. Due to difficulties in assessing hepato-splanchnic perfusion, such effects are often not detected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computed tomography based navigation for endoscopic sinus surgery is inflationary used despite of major public concern about iatrogenic radiation induced cancer risk. Studies on dose reduction for CAS-CT are almost nonexistent. We validate the use of radiation dose reduced CAS-CT for clinically applied surface registration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spontaneous dural arterio-venous fistulas can imperceptibly develop over a long time period before they suddenly develop symptoms like bruit, loss of vision, exophthalmos and conjunctival injection. We present the rare case of an occult, para-infectious, dural arterio-venous fistula which became symptomatic after endoscopic sinus surgery. Conjunctival injection and slight exophthalmos developed due to decompensation of venous drainage probably by intraoperative positioning of the patient, positive pressure ventilation and nasal packing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several studies have reported certain bone morphogenic proteins (BMPs) to have positive effects on bone generation. Although some investigators have studied the effects of human recombinant BMP (rhBMP-2) in sinus augmentation in sheep, none of these studies looked at the placement of implants at the time of sinus augmentation. Furthermore, no literature could be found to report on the impact that different implant systems, as well as the positioning of the implants had on bone formation if rhBMP-2 was utilized in sinus-lift procedures.