309 resultados para QUADRICEPS FEMORIS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Patients with Chronic Obstructive Pulmonary Disease may have muscle dysfunction, which ultimately reduce the functional capacity. Neuromuscular electrical stimulation (NMES) is a technique that can be effective in these patients, and implies low overload to the cardiorespiratory system. The aim of this study was to investigate the effects of NMES on muscle strength and cardiorespiratory fitness in COPD patients. Five patients (2 men, 3 women) were evaluated, with a mean age of 70.40 ± 6.61 years, and underwent anamnesis, anthropometric measurements, spirometry, pulmonary function, cardiopulmonary functional capacity and muscle strength in the lower limbs. After the evaluations, the patients were enrolled in a program of electrical stimulation of the quadriceps muscles, performed 3 times per week for 5 weeks. Each session lasted for 30 minutes, being reassessed at the end of the 15 sessions. Statistically significant response is observed to gain strength in lower limb (p = 0.005), but no significant responses were observed for the distance in six minute walking test before and after the test protocol for electrical stimulation. Showing that with NMES was located just gain muscle strength without effects on functional capacity, and there are few studies that investigate these effects, so further studies are needed to investigate this relationship.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Autohemotherapy is a type of treatment that have acquired an opposite role and have presented its efficiency strived by the medical community for many reasons. In this study we aimed to evaluate the effects of authohaemotherapy on hematological response. Method: We used Wistar female rats (300g). The study consisted in a control group and a treatment group, blood samples were collected at the first day and at the eighth day after the application. In the both groups we collected 300 μl of blood from each rat through a syringe with a previously prepared solution of 30 μl of sodium citrate 3.2%. In the autohemotherapy group the blood sample was immediately injected in the quadriceps muscle on the back of the thigh hind limb. Rats from the control group did not receive intramuscular blood application. The cellular count was done through flow cytometry and the samples were dosed for immunoglobulin. Results: In the both groups we observed increased production of erytrocites, hemoglobin and platelet (p<0.05). However, there was reduction of basophil in the control group and reduction of lymphocyte, monocyte and neutrophil in the both groups. No effects were observed in IgA, IgG and IgM levels. Conclusion: Autohemotherapy did not influence hematological responses in Wistar female rats.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia Animal - FEIS

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho teve como objetivo avaliar características de carcaça por ultra-som de 28 bubalinos jovens Mediterrâneo terminados em confinamento e abatidos aos 450, 480, 510 e 540 kg de peso vivo (PV). Foi utilizado um equipamento de ultra-som Piemedical Scanner 200 Vet, com transdutor linear de 178 mm e 3,5 MHz, a cada intervalo de aproximadamente 28 dias, para obter a área do longíssímus dorsí (ALOU), espessura de gordura subcutânea (EGSU) entre a 12ª e 13ª costelas e a espessura de gordura na picanha (EGP8U), sob o terço superior do músculo bíceps femorís. Após atingirem os pesos de abate pré-estabelecidos, os animais foram abatidos e obteve-se o peso de carcaça quente (PCQ) e o rendimento de carcaça (RC). Após 24 horas de resfriamento, as carcaças foram seccionadas entre a 12a e 13a costelas e obtidas a área do longíssímus dorsí (ALOC), a espessura de gordura (EGSC) e a espessura de gordura sob o bíceps femorís (EGP8C) na carcaça. As correlações entre as medidas por ultra-som e na carcaça foram de 0,96 entre ALOU e ALOC, de 0,99 entre EGSU e EGSC e de 0,91 entre EGP8U e EGP8C. Equações de regressão utilizando o peso vivo (PV), ALOU, EGSU e EGP8U explicaram 95% da variação do PCQ quando a medida foi realizada imediatamente antes do abate. As equações para estimar o RC utilizando as mesmas características explicaram cerca de 32% da variação quando a medida foi realizada imediatamente antes do abate. O peso da porção comestível do corte traseiro a partir de medidas efetuadas por ultra-som e na carcaça é predito com maior magnitude que a percentagem da porção comestível. Os resultados indicam que as equações para as medidas ultra-sônicas apresentaram boa acurácia e podem ser utilizadas para estimar diferenças entre grupos de animais, mas há a necessidade de mais estudos envolvendo maior número de animais e de outros grupos genéticos de bubalinos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was evaluate the effects of three anesthetic combinations, ketamine-midazolam, ketamine-xylazine and tiletamine-zolazepam, on IOP in rabbits. In a experimental, blind, randomized, crossover study, six rabbits were anesthetized with each of 3 treatments in random order. Groups KM (ketamine, 30 mg/kg + midazolam, 1 mg/kg); KX (ketamine, 30 mg/kg + xylazine, 3 mg/kg); and TZ (tiletamine + zolazepam, 20 mg/kg). The drugs were mixed in the same syringe injected intramuscularly (IM) into the quadriceps muscle. IOP was measured before drug administration (baseline) and at 5-minute intervals for 30 minutes. The data were analyzed by a 2-way repeated measures ANOVA followed by Bonferroni test. All groups had significant decreases in IOP compared to baseline (p < 0.001). There was no difference between groups at any of the time points assessed (p > 0.05). Administration of either ketamine-midazolam, ketamine-xylazine, or tiletamine-zolazepam similarly decrease IOP in rabbits within 30 minutes of injection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Throughout the history of medicine surgeons realized the importance of the patella to the functioning of the knee. The main function of the patella is to increase the mechanical efficiency of the quadriceps tendon and knee extensor mechanism. It was found that 50% to 80% of the fractures without deviation of the patella have the transversal pattern, possibly due to excessive tensile forces applied to the extensor mechanism. The purpose of this study is to analyze the loads to which a patella is submitted during a normal extension movement of knee. This analysis will be done by modeling a 3D patella and subsequent load simulation as, described in medical literature, using the finite element method

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O joelho, por suas características anatômicas e freqüente instabilidade e exposição as lesões tem o quadríceps como importante músculo a ser desenvolvido quanto ao seu trofismo e força. Composto de quatro porções distintas estas podem gerar diferentes vetores de força que podem ter relações diretas com o recrutamento de unidades motoras. O posicionamento articular, a conseqüente modificação do comprimento muscular e a intensidade da contração podem influenciar o desenvolvimento da força do quadríceps. Dentre as contrações relacionadas ao maior recrutamento de unidades motoras com o intuito do desenvolvimento de força está a contração isométrica. Dentre as contrações musculares, as isométricas têm sido frequentemente indicadas para aumentar a força e estabilidade articular em sessões de treinamento e reabilitação. Pelo exposto, o objetivo do estudo foi analisar os músculos vasto medial (VM) e vasto lateral (VL) por meio da eletromiografia de superfície durante 15s de contração isométrica a 20%, 30%, 40% e 50% da contração isométrica voluntária máxima – CIVM com o joelho a 90 graus. Foram utilizados eletrodos de superfície bipolar de Ag/AgCl, posicionados nos músculos VM e VL, um módulo de aquisição de sinais biológicos (Lynx) calibrado com ganho de 1000vezes, filtro de passa alta de 20Hz e de passa baixa de 500Hz. Uma célula de carga foi acoplada perpendicularmente à cadeira de teste especialmente desenvolvida para o estudo e utilizado uma indicador digital para retorno visual. Na análise estatística utilizou-se teste de Friedman e teste de Wilcoxon, e adotou-se nível de significância de p<0,05. Verificou-se que os músculos VM e VL foram semelhantes entre si, e entre as cargas, houve diferença significante entre as cargas de 20% e 40%, 20% e 50%, e 30% e 50% para ambos os músculos, com maior atividade nas cargas de 40% e 50% CVM... (Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Muscle fatigue is described as a cause of injuries among the many related to the running practice. Therefore, the purpose of this study was to analyze the behavior of the amplitude (RMS) and median frequency (MF) of EMG signal of the iliocostalis (CI), rectus femoris (RF), vastus lateralis (VL), vastus medialis (VM) biceps femoris (long head) (BFCL), tibialis anterior (TA) and gastrocnemius (lateral) (LNG) from the right lower limb, and the behavior of the parameters of amplitude (AP) and frequency (PF) spent in different percentages of the maximum speed during incremental protocol of treadmill running. 10 volunteers participated in this study, athletes, male, aged between 18 and 30 years with no history of injury in lower limbs and similar anthropometry. The protocol consisted of a treadmill test with initial velocity of 10 km.h-¹ and increments of 1 km.h-¹ each three minutes until volitional exhaustion, without rest interval. Synchronized collections were made of electromyographic and kinematic data. The signals were obtained through an acquisition module of biological signals (Telemyo 900 - Noraxon - USA) and software (Myoresearch - Noraxon - USA) calibrated with a sampling frequency of 1000 Hz, gain 2000 times. The raw data were filtered with a 60Hz notch filter, high pass and low pass 20Hz to 500Hz. To capture the image was used a digital video recorder (model NV-GS320, PANASONIC brand), and for image scanning and kinematic data collection was used the software Peak Motus 9.0 (ViconPeak). To obtain the values of RMS and FM analyzed the last ten passes of each speed through a specific routine (Matlab). To obtain these variables AP (m) and FP (stride I min) were analyzed for the last ten past each speed, using specific software (Peak Motus 9.0). After verification of data normality (Shapiro-Wilk) and homogeneity of the data (Levene), the comparison ...(Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the chemical and lipid composition of uncooked or cooked loin (Longissimus thoracis) and rump (Biceps femoris) in samples of 2.54 cm thick from 35 carcasses of Nellore young bulls finished in feedlot for 96 days and slaughtered at an average weight of 532.17 ± 30.25 kg and 24 months of age. The rump had the lowest level of protein and ash (18.57 and 0.90%, respectively) and the highest level of ether extract compared to loin (3.37 and 1.90%, respectively). Higher levels of cholesterol were found in rump compared to loin (40.91 e 30.93 mg 100 g-1, respectively). The uncooked loin showed lower content of saturated fatty acids and higher content of polyunsaturated fatty acids. The best values for the omega-6: omega-3 ratio was observed in the uncooked beef. In the present study, the loin was healthier due to the higher amount of polyunsaturated fatty acids compared to rump. Cooking the meat decreases the levels of polyunsaturated fatty acids, omega-3, omega-6 and the omega-6: omega-3 ratio.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[Purpose] Sit-to-walk performance is linked to proper proprioceptive information processing. Therefore, it is believed that an increase of proprioceptive inflow (using muscle vibration) might improve sit-to-walk performance. However, before testing muscle vibration effects on a frail population, assessment of its effects on healthy young people is necessary. Thus, the aim of this study was to investigate the effects of muscle vibration on sit-to-walk performance in healthy young adults. [Subjects and Methods] Fifteen young adults performed the sit-to-walk task under three conditions: without vibration, with vibration applied before movement onset, and with vibration applied during the movement. Vibration was applied bilaterally for 30 s to the tibialis anterior, rectus femoris, and upper trapezius muscles bellies. The vibration parameters were as follows: 120 Hz and 1.2 mm. Kinematics and kinetic data were assessed using a 3D motion capture system and two force plates. The coordinates of reflective markers were used to define the center-of-mass velocities and displacements. In addition, the first step spatiotemporal variables were assessed. [Results] No vibration effect was observed on any dependent variables. [Conclusion] The results show that stimulation of the proprioceptive system with local muscle vibration does not improve sit-towalk performance in healthy young adults.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The elevated Q-angle seems to be one of the most suggested factors contributing to patellofemoral pain. Females with patellofemoral pain are often evaluated through static clinical tests in clinical practice. However, the adaptations seem to appear more frequently in dynamic conditions. Performing static vs. dynamic evaluations of widely used measures would add to the knowledge in this area. Therefore, the aim of this study was to determine the reliability and discriminatory capability of three Q-angle measurements: a static clinical test, peak dynamic knee valgus during stair ascent and a static measurement using a three-dimensional system. Twenty-nine females with patellofemoral pain and twenty-five pain-free females underwent clinical Q-angle measurement and static and dynamic knee valgus measurements during stair ascent, using a three-dimensional system. All measurements were obtained and comparisons between groups, reliability and discriminatory capability were calculated. Peak dynamic knee valgus was found to be greater in the patellofemoral pain group. On the other hand, no significant effects were found for static knee valgus or clinical Q-angle measurements between groups. The dynamic variable demonstrated the best discriminatory capability. Low values of reliability were found for clinical Q-angle, in contrast to the high values found for the three-dimensional system measurements. Based on our findings, avoiding or correcting dynamic knee valgus during stair ascent may be an important component of rehabilitation programs in females with patellofemoral pain who demonstrate excessive dynamic knee valgus. Q-angle static measurements were not different between groups and presented poor values of discriminatory capability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Among the numerous possibilities of physical exercise, it has been recommended that stretching routines should be incorporated into training programs focused on the elderly population, and that these routines should be preferentially performed on the same strength or aerobic training session. However, studies have shown that muscle strength production can be acutely impaired if it is preceded by static stretching exercises (AE). Although there seems to be a relationship between the number of stretched muscles and strength response, no studies were found examining such relationship in the same study, simultaneously. Thus, the objective of this study is to analyze the acute effect of stretching of different muscle groups on strength performance in older women. Nineteen physically active older women participated in the study (67.8 ± 5.3 years, 68.9 ± 12.4 kg, 157.2 ± 6.4 cm)-usar ponto final em inglês e não vírgula. The participants visited the lab for six consecutive days, three of which were intended to familiarization. Over the next three days, all the participants performed the experimental conditions: control; quadriceps stretching alone and complete stretching, involving the major extensors muscle groups of knees and hips. Both the two stretching conditions were realized with three series of 30s (total volume of 90 seconds for each exercise). All experimental conditions was be performed with an interval of at least 24 hours and order of execution was be randomized. The force transducer was connected to a leg press apparatus, where the isometric force time curve and electromyographic activity of the vastus medial and vastus lateralis were recorded. Measurements were registered immediately after each experimental condition, during five seconds. Statistical analysis comprised descriptive procedures and the One way ANOVA test for repeated measures (p<0.05). No statistically significant differences between the control and the two...