963 resultados para Pulses


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Off-resonance RF pre-saturation was used to obtain contrast in MRI images of polymer gel dosimeters irradiated to doses up to 50 Gy. Two different polymer gel dosimeters composed of 2-hydroxyethyl-acryl ate or methacrylic acid monomers mixed with N, N'-methylene-bisacrylamide (BIS), dispersed in an aqueous gelatin matrix were evaluated. Radiation-induced polymerization of the co-monomers generates a fast-relaxing insoluble polymer. Saturation of the polymer using off-resonance Gaussian RF pulses prior to a spin-echo read-out with a short echo time leads to contrast that is dependent on the absorbed dose. This contrast is attributed to magnetization transfer (MT) between free water and the polymer, and direct saturation of water was found to be negligible under the prevailing experimental conditions. The usefulness of MT imaging was assessed by computing the dose resolution obtained with this technique. We found a low value of dose resolution over a wide range of doses could be obtained with a single experiment. This is an advantage over multiple spin echo (MSE) experiments using a single echo spacing where an optimal dose resolution is achieved over only very limited ranges of doses. The results suggest MT imaging protocols may be developed into a useful tool for polymer gel dosimetry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bees generate thoracic vibrations with their indirect flight muscles in various behavioural contexts. The main frequency component of non-flight vibrations, during which the wings are usually folded over the abdomen, is higher than that of thoracic vibrations that drive the wing movements for flight. So far, this has been concluded from an increase in natural frequency of the oscillating system in association with the wing adduction. In the present study, we measured the thoracic oscillations in stingless bees during stationary flight and during two types of non-flight behaviour, annoyance buzzing and forager communication, using laser vibrometry. As expected, the flight vibrations met all tested assumptions for resonant oscillations: slow build-up and decay of amplitude; increased frequency following reduction of the inertial load; and decreased frequency following an increase of the mass of the oscillating system. Resonances, however, do not play a significant role in the generation of non-flight vibrations. The strong decrease in main frequency at the end of the pulses indicates that these were driven at a frequency higher than the natural frequency of the system. Despite significant differences regarding the main frequency components and their oscillation amplitudes, the mechanism of generation is apparently similar in annoyance buzzing and forager vibrations. Both types of non-flight vibration induced oscillations of the wings and the legs in a similar way. Since these body parts transform thoracic oscillations into airborne sounds and substrate vibrations, annoyance buzzing can also be used to study mechanisms of signal generation and transmission potentially relevant in forager communication under controlled conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare changes in corneal hysteresis (CH) and the corneal resistance factor (CRF) in myopic and hyperopic laser in situ keratomileusis (LASIK) and evaluate their relationship to the number of photoablative pulses delivered, a surrogate for ablation volume. SETTING: Cleveland Clinic Cole Eye Institute, Cleveland, Ohio, USA. METHODS: Preoperative and 1-week postoperative Ocular Response Analyzer measurements in eyes that had femtosecond-assisted LASIK were studied retrospectively. Changes in CH and CRF were compared and tested for correlation with the number of excimer laser pulses. RESULTS: Thirteen myopic eyes and 11 hyperopic eyes were evaluated. Preoperative corneal thickness, CH, CRF, programmed correction magnitude, flap thickness, and total number of fixed spotsize photoablative pulses were similar in the 2 groups (P>.1). Decreases in CH and CRF were greater after myopic LASIK than after hyperopic LASIK (P<.005), and changes in CRF were correlated with the number of excimer laser pulses in the myopic group only (r = -0.63, P = .02). Regardless of ablation profile, changes in CH were more strongly correlated with preoperative CH values than with attempted ablation volume. CONCLUSIONS: With comparable flap thickness and attempted ablation volumes, myopic photoablation profiles were associated with greater decreases in CRF and CH than hyperopic profiles. Results indicate that preoperative corneal biomechanical status, ablation volume, and the spatial distribution of ablation are important factors that affect corneal resistance and viscous dissipative properties differently. Preferential tissue removal in the natively thicker paracentral cornea in hyperopia may partially account for the rarity of ectasia after hyperopic LASIK.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This report considers the rare situation in which primary antiphospholipid syndrome (PAPS) is linked with thrombotic thrombocytopenic purpura (TTP). It describes the case of a young lady with PAPS, characterized by recurring cerebro-vascular abnormalities and marked livedo reticularis, combined with circulating anticardiolipin and lupus anticoagulant antibodies. On follow-up, while on oral anticoagulation, she developed severe thrombocytopenia associated with hematuria, microangiophatic anaemia and neurological manifestations consistent with a diagnosis of TTP. The patient was treated with pulses of methylprednisolone and plasmapheresis with plasma exchange. The result was a favourable outcome. To our knowledge, this is the seventh report on this rare association in the English-language literature of this field. Lupus (2009) 18, 841-844.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vagal Denervation and Neurally Mediated Syncope. A 15-year-old female patient presented with frequent episodes of vasovagal syncope refractory to non-pharmacological and pharmacological measures. Two tilt-table tests performed before and after conventional therapy were positive and reproduced the patient`s clinical symptoms. Selective vagal denervation, guided by HFS, was performed. Six radiofrequency pulses were applied on the left and right sides of the interatrial septum, abolishing vagal responses at these locations. Basal sinus node and Wenckebach cycle lengths changed significantly following ablation. A tilt test performed after denervation was negative and revealed autonomic tone modification. The patient reported significant improvement in quality of life and remained asymptomatic for 9 months after denervation. After this period, three episodes of NMS occurred during a 4-month interval and a tilt test performed 11 months after the procedure demonstrated vagal activity recovery. (J Cardiovasc Electrophysiol, Vol. 20, pp. 558-563, May 2009).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gastric Palsy Following AF Vagal Ablation. We report a case of a 55-year-old man with vagal paroxysmal atrial fibrillation (AF) who was submitted to selective epicardial and endocardial atrial vagal denervation with the objective of treating AF. Radiofrequency pulses were applied on epicardial and endocardial surface of the left atrium close to right pulmonary veins (PVs) and also on epicardial surface close to left inferior PV. Following the procedure, patient presented with symptoms of gastroparesis, which was documented on CT scan and gastric emptying scintigraphy. Symptoms were transient and the patient recovered completely.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present results from both theoretical and experimental studies of the noise characteristics of mode-locked superfluorescent lasers. The results show that observed macroscopic broadband amplitude noise on the laser pulse train has its origin in quantum noise-initiated ''phase-wave'' fluctuations, and we find an associated phase transition in the noise characteristics as a function of laser cavity detuning.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The technique of frequency-resolved optical gating is used to characterize the intensity and the phase of picosecond pulses after propagation through 700 m of fiber at close to the zero-dispersion wavelength. Using the frequency-resolved optical gating technique, we directly measure the severe temporal distortion resulting from the interplay between self-phase modulation and higher-order dispersion in this regime. The measured intensity and phase of the pulses after propagation are found to be in good agreement with the predictions of numerical simulations with the nonlinear Schrodinger equation. (C) 1997 Optical Society of America.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A robust semi-implicit central partial difference algorithm for the numerical solution of coupled stochastic parabolic partial differential equations (PDEs) is described. This can be used for calculating correlation functions of systems of interacting stochastic fields. Such field equations can arise in the description of Hamiltonian and open systems in the physics of nonlinear processes, and may include multiplicative noise sources. The algorithm can be used for studying the properties of nonlinear quantum or classical field theories. The general approach is outlined and applied to a specific example, namely the quantum statistical fluctuations of ultra-short optical pulses in chi((2)) parametric waveguides. This example uses a non-diagonal coherent state representation, and correctly predicts the sub-shot noise level spectral fluctuations observed in homodyne detection measurements. It is expected that the methods used wilt be applicable for higher-order correlation functions and other physical problems as well. A stochastic differencing technique for reducing sampling errors is also introduced. This involves solving nonlinear stochastic parabolic PDEs in combination with a reference process, which uses the Wigner representation in the example presented here. A computer implementation on MIMD parallel architectures is discussed. (C) 1997 Academic Press.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background-Epicardial coronary injury is by far the most feared complication of epicardial ablation. Little information is available regarding the chronic effects of delivering radiofrequency in the vicinity of large coronary vessels, and the long-term impact of this approach for mapping and ablation on epicardial vessel integrity is poorly understood. Therefore, the aim of this study was to characterize the acute and chronic histopathologic changes produced by in vivo epicardial pulses of radiofrequency ablation on coronary artery of porcine hearts. Methods and Results-Seven pigs underwent a left thoracotomy. The catheter was sutured adjacent to the left anterior descending artery and left circumflex artery, and 20 pulses of radiofrequency energy were applied. Radiofrequency lesions located no more than 1 mm of the vessel were used for this analysis. Three animals were euthanized 20 days (acute phase) after the procedure and 4 animals after 70 days (chronic phase). The following parameters were obtained in each vessel analyzed: (1) internal and external perimeter; (2) vessel wall thickness; (3) tunica media thickness, and (4) tunica intima thickness. The presence of adipose tissue around the coronary arteries, the distance between the artery and the epicardium, and the anatomic relationship of the artery with the coronary vein was also documented for each section. Sixteen of 20 (80%) sections analyzed, showed intimal thickening with a mean of 0.18 +/- 0.14 mm compared with 0.13 +/- 0.16 mm in the acute phase (P=0.331). The mean tunica media thickness was 0.25 +/- 0.10 mm in the chronic phase animals compared with 0.18 +/- 0.03 mm in the acute phase animals (P=0.021). A clear protective effect of pericardial fat and coronary veins was also present. A positive correlation between depth of radiofrequency lesion and the degree of vessel injury expressed as intimal and media thickening (P=0.001) was present. A negative correlation was identified (r = -0.83; P=0.002) between intimal thickening and distance between epicardium and coronary artery. Conclusions-In this porcine model of in vivo epicardial radiofrequency ablation in proximity to coronary arteries leads to acute and chronic histopathologic changes characterized by tunica intima and media thickening, with replacement of smooth muscle cells with extracellular matrix, but no significant stenosis was observed up to 70 days after the ablation. The absence of acute coronary occlusion or injury does not preclude subsequent significant arterial damage, which frequently occurs when epicardial radiofrequency applications are delivered in close vicinity to the vessels. (Circ Arrhythm Electrophysiol. 2011;4:526-531.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

From a general model of fiber optics, we investigate the physical limits of soliton-based terabaud communication systems. In particular we consider Raman and initial quantum noise effects which are often neglected in fiber communications. Simulations of the position diffusion in dark and bright solitons show that these effects become increasingly important at short pulse durations, even over kilometer-scale distances. We also obtain an approximate analytic theory in agreement with numerical simulations, which shows that the Raman effects exceed the Gordon-Haus jitter for sub-picosecond pulses. (C) 1997 Elsevier Science B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is shown that coherent quantum simultons (simultaneous solitary waves at two different frequencies) can undergo quadrature-phase squeezing as they propagate through a dispersive chi((2)) waveguide. This requires a treatment of the coupled quantized fields including a quantized depleted pump field. A technique involving nonlinear stochastic parabolic partial differential equations using a nondiagonal coherent state representation in combination with an exact Wigner representation on a reduced phase space is outlined. We explicitly demonstrate that group-velocity matched chi((2)) waveguides which exhibit collinear propagation can produce quadrature-phase squeezed simultons. Quasi-phase-matched KTP waveguides, even with their large group-velocity mismatch between fundamental and second harmonic at 425 nm, can produce 3 dB squeezed bright pulses at 850 nm in the large phase-mismatch regime. This can be improved to more than 6 dB by using group-velocity matched waveguides.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We show how a nonlinear chaotic system, the parametrically kicked nonlinear oscillator, may be realized in the dynamics of a trapped, laser-cooled ion, interacting with a sequence of standing-wave pulses. Unlike the original optical scheme [G. J. Milburn and C.A. Holmes, Phys. Rev. A 44, 4704 (1991)], the trapped ion enables strongly quantum dynamics with minimal dissipation. This should permit an experimental test of one of the quantum signatures of chaos: irregular collapse and revival dynamics of the average vibrational energy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigated the role of endogenous opioid systems in the analgesic effects induced by repetitive transcranial magnetic stimulation (rTMS). We compared the analgesic effects of motor cortex (M1) or dorsolateral prefrontal cortex (DLPFC) stimulation before and after naloxone or placebo treatment, in a randomized, double-blind crossover design, in healthy volunteers. Three groups of 12 volunteers were selected at random and given active stimulation (frequency 10 Hz, at 80% motor threshold intensity, 1500 pulses per session) of the right M1, active stimulation of the right DLPFC, or sham stimulation, during two experimental sessions 2 weeks apart. Cold pain thresholds and the intensity of pain induced by a series of fixed-temperature cold stimuli (5, 10, and 15 degrees C) were used to evaluate the analgesic effects of rTMS. Measurements were made at the left thenar eminence, before and 1 hour after the intravenous injection of naloxone (bolus of 0.1 mg/kg followed by a continuous infusion of 0.1 mg/kg/h until the end of rTMS) or placebo (saline). Naloxone injection significantly decreased the analgesic effects of M1 stimulation, but did not change the effects of rTMS of the DLPFC or sham rTMS. This study demonstrates, for the first time, the involvement of endogenous opioid systems in rTMS-induced analgesia. The differential effects of naloxone on M1 and DLPFC stimulation suggest that the analgesic effects induced by the stimulation of these 2 cortical sites are mediated by different mechanisms. (C) 2010 Published by Elsevier B.V. on behalf of International Association for the Study of Pain.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study evaluated the effectiveness of electrotactile tongue biofeedback (BrainPort (R)) as a sensory substitute for the vestibular apparatus in patients with bilateral vestibular loss (BVL) who did not have a good response to conventional vestibular rehabilitation (VR). Seven patients with BVL were trained to use the device. Stimulation on the surface of the tongue was created by a dynamic pattern of electrical pulses and the patient was able to adjust the intensity of stimulation and spatially centralize the stimulus on the electrode array. Patients were directed to continuously adjust head orientation and to maintain the stimulus pattern at the center of the array. Postural tasks that present progressive difficulties were given during the use of the device. Pre- and post-treatment distribution of the sensory organization test (SOT) composite score showed an average value of 38.3 +/- 8.7 and 59.9 +/- 11.3, respectively, indicating a statistically significant improvement (p = 0.01). Electrotactile tongue biofeedback significantly improved the postural control of the study group, even if they had not improved with conventional VR. The electrotactile tongue biofeedback system was able to supply additional information about head position with respect to gravitational vertical orientation in the absence of vestibular input, improving postural control. Patients with BVL can integrate electrotactile information in their postural control in order to improve stability after conventional VR. These results were obtained and verified not only by the subjective questionnaire but also by the SOT composite score. The limitations of the study are the small sample size and short duration of the follow-up. The current findings show that the sensory substitution mediated by electrotactile tongue biofeedback may contribute to the improved balance experienced by these patients compared to VR. (C) 2010 Elsevier Ireland Ltd. All rights reserved.