916 resultados para Project 2001-005-B-02 : Indoor Environments : Design, Productivity and Health
Resumo:
Guía de revisión y apoyo para alumnos de educación secundaria de segundo ciclo que estén realizando el curso del OCR (Oxford Cambridge and RSA Examinations) en los niveles AS y A2 del área de química. Está estructurada en cuatro secciones que presentan una serie de consejos generales sobre cuestiones relacionadas con el trabajo práctico (obtención, registro y proceso de resultados en experimentos prácticos), un apartado de orientación para la realización de investigaciones individualizadas, un apéndice con algunos temas de teoría útiles en la investigación, y una sección final con las soluciones a las preguntas y ejercicios que aparecen a lo largo del libro.
Resumo:
Resumen basado en el de la publicación
Resumo:
The objective of the present study was to determine the optimum plant density of four pigeonpea genotypes, representing early, medium and late maturing types, grown in five contrasting environments in Tanzania. ICPL 86005 (early), Kat 50/3 and QP 37 (medium) and Local (late) were grown at four plant densities (40 000-320 000 plants/ha) in irrigated and rainfed conditions at Ilonga and under rainfed conditions at Kibaha, Selian and Ismani. At maturity, total above-ground biomass and seed yield (SY) were measured. The highest yields were obtained in the irrigated experiment at Ilonga, where the medium/late genotypes produced 25 t biomass/ha and 5 center dot 6 t seed/ha. The lowest SY were at Kibaha, 0 58 to 1 center dot 76 t/ha, where a severe drought occurred. In nearly all cases the response to density was linear or asymptotic. The response of ICPL 86005 was significantly different from the other three genotypes. The optimum density for SY varied from 37 000 to 227 000 plants/ha in ICPL 86005, compared with 3000 to 101000 plants/ha in the medium/late genotypes. The highest optimum density was at Selian and Ismani and the lowest at Ilonga and Kibaha, where drought occurred. Optimum densities therefore varied greatly with genotype (duration) and environment, and this variation needs to be considered when planning trials.
Resumo:
This paper summarizes the design, manufacturing, testing, and finite element analysis (FEA) of glass-fibre-reinforced polyester leaf springs for rail freight vehicles. FEA predictions of load-deflection curves under static loading are presented, together with comparisons with test results. Bending stress distribution at typical load conditions is plotted for the springs. The springs have been mounted on a real wagon and drop tests at tare and full load have been carried out on a purpose-built shaker rig. The transient response of the springs from tests and FEA is presented and discussed.
Resumo:
Small mammals and stray cats were trapped in two areas of North Zealand, Denmark, and their blood cultured for hemotrophic bacteria. Bacterial isolates were recovered in pure culture and subjected to 16S rDNA gene sequencing. Bartonella species were isolated from five mammalian species: B. grahamii from Microtus agrestis (field vole) and Apodemus flavicollis (yellow-necked field mouse); B. taylorii from M. agrestis, A. flavicollis and A. sylvaticus (long-tailed field mouse); B. tribocorum from A. flavicollis; R vinsonii subsp. vinsonii from M. agrestis and A. sylvaticus; and B. birtlesii from Sorex vulgaris (common shrew). In addition, two variant types of B. henselae were identified: variant I was recovered from three specimens of A. sylvaticus, and B. henselae variant 11 from I I cats; in each case this was the only B. henselae variant found. No Bartonella species was isolated from Clethrionomys glareolus (bank vole) or Micromys minutus (harvest mouse). These results suggest that B. henselae occurs in two animal reservoirs in this region, one of variant I in A. sylvaticus, which may be transmitted between mice by the tick Ixodes ricinus, and another of variant 11 in cats, which may be transmitted by the cat flea (Ctenocephalides felis). To our knowledge, this is the first report of the occurrence of B. henselae and B. tribocorum in Apodemus mice.
Resumo:
Threatening intrusive images are central to posttraumatic stress disorder. It has been suggested that intrusive imagery in the context of a sense of threat leads to the development and persistence of posttraumatic stress symptoms. This study investigates London school children's (N = 76; age 10-11 years) self-reported posttraumatic stress symptoms in response to viewing the attacks of September 11, 2001 on television. Assessments were made at two time points. A minority of participants reported moderate-severe symptoms with functional impairment at 2 months (14.5%) and 6 months (9.2%) after viewing the September 11events. After controlling for symptom stability, persistent symptoms were associated with peri-traumatic factors, notably perceiving that one's life was in danger. The combined effect of intrusive imagery and peri-traumatic life threat was associated with symptom persistence. Assessments of intrusive image content via checklist and free-report indicated that the images were directly related to September 11 and were fairly stable over time. Implications for treating children's intrusive images following stressful events are explored. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
The two major applications of microwave remote sensors are radiometer and radar. Because of its importance and the nature of the application, much research has been made on the various aspects of the radar. This paper will focus on the various aspects of the radiometer from a design point of view and the Low Noise Amplifier will be designed and implemented. The paper is based on a study in radio Frequency Communications engineering and understanding of electronic and RF circuits. Some research study about the radiometer and practical implementation of Low Noise Amplifier for Radiometer will be the main focus of this paper. Basically the paper is divided into two parts. In the first part some background study about the radiometer will be carried out and commonly used types of radiometer will be discussed. In the second part LNA for the radiometer will be designed.