944 resultados para Preços - Estabilização
Resumo:
Stabilization pond is the main technology used for treatment wastewater, in northeast Brazil, due to lower cost of deployment, operation and maintenance compared to other technologies. Most systems of stabilization ponds has been in operation for some time, on average 10 years of operation, receiving high organic loads and do not have good removal efficiencies of the main parameters for which have been designed. Therefore it is necessary to work to quantify the efficiency of current systems. This study evaluated the biodegradability of organic matter in raw sewage, the removal of organic matter in reactors and determination of the kinetic constant removal of organic matter (k), both in reactors and in raw sewage, based on the analysis made in the laboratory and through mathematical methods proposed in the literature, in nine systems stabilization ponds, located in Rio Grande do Norte. In relation the degradation kinetics in stabilization ponds, it was observed that many papers published in the literature were obtained in pilot-scale systems, which often, due to the action of external factors such as wind and temperature, these can t be considered as a reference in the analysis of the kinetic constant K, so the need for more research into systems of scale. This study had three distinct phases and simultaneous, routine monitoring, study of the daily cycle and the determination of kinetic constant of degradation of organic matter (K). The monitoring showed that the removal efficiencies of organic matter on most systems were lower than suggested by the literature, the best efficiencies of around 76% (BOD) and 72% (COD) and the worst of the order of 48% (BOD) and 55% (COD). The calculation of K in raw sewage (Ke) was within the range of variation expected in the literature (0.35 to 0.60 days-1). Already for the results obtained for K in the reactors (Kr), there were well below the values recommended in the literature (0.25 to 0.40 d-1 for complete mix and from 0.13 to 0.17 d-1 for flow dispersed), in line with the overloads that organic systems are subject
Resumo:
Experience in the use of stabilization ponds shows that this is a system with low cost, easy operation and maintenance and suitable for tropical countries. One of its disadvantages is due to high concentrations of suspended solids, mainly due to algal biomass in the effluents. Accordingly, the dissolved air flotation has been shown to be an efficient post-treatment technology. However, the efficiency of this process is related to coagulation and flocculation steps, as well as the adjustment of the involved variables in the process. The objective of this work was to evaluate the algae removal efficiency from wastewater stabilization ponds and the influence of the factors involved in the process using dissolved air flotation. For this, we used primary facultative and maturation effluents of ETE Ponta Negra in Natal. We did tests of coagulation, flocculation and flotation with the samples, using the equipment flotatest. In this process were tested coagulants aluminum sulfate and ferric chloride, and varied the factors pH, coagulant concentration, polymer concentration and rate of recirculation. At the end of the experiments were analyzed turbidity, suspended solids, color, COD and chlorophyll "a". These results were submitted to descriptive statistics to verify the efficiency of the process in general, and regression analysis to identify models that describe the process and demonstrate the factors that have greater influence on flotation. After step methodology, high values were found removal efficiency of suspended solids, reaching values greater than 90% in the best cases. It was concluded that flotation is more efficient in the facultative pond effluent using ferric chloride, and the variability of algae may negatively influence the process. Regression analyzes showed that pH is the most influential variable in the coagulation-flocculation-flotation, and its optimal value among the tested is 5.5 for both coagulants
Resumo:
Stabilization pond is the most used sewage treatment system in the country, corresponding to approximately 90% of all systems. The systems evaluated were stabilization ponds system of sewage treatment in the city of Natal / RN. This research aimed to analyze the possible uses through physical-chemical and bacteriological of these final effluent ponds for urban uses depending on the characteristics after passage around the treatment system. The parameters used were chosen according to those established by Chernicharo et al. (2006), in order to characterize the effluent. The parameters evaluated were: DO, temperature, pH, conductivity, organic nitrogen, ammonia, NTK, total phosphorus, and series of solid fecal coliforms. Generally, the characteristics of the effluent followed variability found in the literature. The results showed an efficiency that is technically feasible to use the effluent end of some of STPs analyzed when checked parameters alone, if fitting in unrestricted urban use, restricted use and urban land use
Resumo:
This research evaluated the microalgae removal produced in a stabilization pond system using biofilters as post-treatment, besides characterizing the effluents of stabilization ponds and filters in relation to concentrations of algal biomass (chlorophyll a and suspended solids), organic matter (BOD and COD), total phosphorus, orthophosphate, pH and dissolved oxygen, and tried to correlate physicochemical parameters with chlorophyll "a". It was held at the Ponta Negra ETE which is constituted by three stabilization ponds, with a primary facultative pond and two of maturation. For the algae removal were used two submerged bio-filters: the filter FPF (Facultative Pond Filter), fed with facultative pond effluent; and the filter MPF (Maturation Pond Filter), fed with second maturation pond effluent. The filling material of both filters was predominantly gravel no. 2, although it contains portions of gravel no. 1 and no. 3. The filters operating conditions were bad, they were nearly 10 years without maintenance, without cleaning or removal of sludge since the time of its construction, and part of the filling material may be obstruct. Despite poor operating conditions were obtained satisfactory results, in level of posttreatment. Removal efficiencies in relation to BOD and COD were 7 and 25% in FPF and 9 and 19% and in MPF, respectively. In relation to TSS efficiencies in MPF and FPF were 37 and 20%, respectively. As for the chlorophyll "a" removal, the FPF efficiency was 44% and the MPF was 40%. There was 50% of consumption of dissolved oxygen, on average, within the filters. Two profiles were performed in the filters, and it was possible to conclude that variations throughout the day were not statistically significant, and that, regardless of the time of collection, they would have the same representation comparing to the time of data collection (7 am) and the daily average, although individual variations throughout the day have been shown to be significant. Another important observation is that the correlations between Chlorophyll a and TSS were bigger and more significant in the effluent of the filters than in the effluent of the ponds
Resumo:
Waste stabilization ponds are the main technology in use for domestic sewage treatment in Rio Grande do Norte State (RN), northeast Brazil. The are around 80 systems, constructed mainly by municipal city halls, being series comprised by a primary facultative pond followed by two maturation ponds the most used configuration. Due to problems related with the production and destination of sludge and generation of bad odors, the designers have avoided the use of anaerobic lagoons. The majority of systems are rarely monitored to verify their efficiencies and to get new project parameters for future designing. This work has as purpose to make a diagnosis of efficiency of three series of waste stabilization pond series (WSPS) of Jardim Lola 1, Jardim Lola 2 and Beira Rio, located in the North Zone of the city of the Natal/RN, treating domestic raw sewage, on the removal of organic matter and thermotolerant coliform, comparing the operational conditions of the systems this inside of the bands foreseen in the project, through parameters BOD5, QOD, thermotolerant coliforms, dissolved oxygen, pH, temperature, ammoniac nitrogen, total and suspended solids. The work was carried through in the WSPS, all constituted by a primary facultative pond followed by two maturation ponds. Socioeconomic characteristics of population are predominantly low and all the plants are very near of the contributing basins. The series were monitored from of May the November of 2002, totalizing 20 collections of grab samples of raw sewage and ponds effluents between 8:00 and 9:50 h. The main aspect to be detached by the results was the great concentration of organic matter (BOD and COD) and microorganisms the raw sewage which were around two times more concentrated than those values foreseen one in project. Considering all series the highest removals of organic matter were observed in system Beira Rio (84 and 78% of BOD and COD, respectively), which presented high hydraulic detention time (TDH = 89 days). On the other hand, Jardim Lola 1 and Jardim Lola 2 presented a much lower values of HDT (36 days and 18 days respectively) and their removals of BOD and COD were the same (76% and 60%, respectively). The Beira Rio WSPS, was the most efficient verified in relation to solids and ammonia, proving the great influence of the operational variables such as HDT and applied surface organic loadings on the performance of pond series. Although the treatment plants have reached efficiencies of thermotolerant coliforms around 99,999%, the concentrations in the final effluent can be considered very high for launching in aquatic bodies, particularly those produced by Jardim Lola 1 and Jardim Lola 2 series
Resumo:
This work intends to develop an approach based through scientific criteria in the operational diagnosis of ponds of stabilization, starting from analyses accomplished in loco and in laboratory of 78 systems of sewer treatment through ponds of stabilization in the State of Rio Grande do Norte. The objectives of the research are: to map, to evaluate and to diagnose the operational acting of the ponds of stabilization of the state of Rio Grande do Norte, through visits in loco and analyses laboratory; to build a SIG, through the map rain, locate the points of releases of sewages of the systems of existent ponds in Rio Grande do Norte, as well as operational data and his/her respective efficiency diagnosis in the removal of BOD and Coliforms Termotolerantes; to evaluate, in real scale, three systems of ponds of stabilization of RN in the operational efficiency for the parameters BOD5, COD, pH, Temperature, OD and Coliforms Termotolerantes. Of 78 ETEs of appraised RN just, 9% or 7 had maximum concepts in what concerns the removal of BOD and Coliforms Termotolerantes and 41% or 32, they had the worst concepts in term of operational efficiency. The flowing concentrations ETEs of RN of BOD and Coliforms were of 410mg/L and 2,50x107UFC/100ml, the predominant configuration is of the type F1+M1+M2, the relationship BOD/COD revealed for the sewer tributary characteristic biodegradable high. For the study of case of 3 ETEs, the best operational efficiencies in decreasing order were: Cidade (Municipal district), it Roça (State) and São Miguel (SAAE). The removals of final BOD were 51,6mg/L; 108,27mg/L and 62,6mg/L, tends efficiency of 82%; 74% and 81%. In term of coliforms removal in the final effluentes were 1,90x103UFC/100ml; 1,50x104UFC/100ml and 3,10x104UFC/100ml, tends efficiencies of 99,99%; 99,95% and 99,90%. In what it concerns the practice of agricultural reúso of cultures consumed raw, none of 3 ETEs assisted the parameters of the Resolution CONAMA 357/05, for other reúso practices, all assisted the categories B and C of OMS. For release in body receiving ETE Cidade just, they assist the demands of the resolution of CONAMA 357/05, by study of purification solemnity of the receiving body. The maintenance lack and operation; exclusive operator in ETEs and operation knowledge was the contributory factors for the operational fall in appraised ETEs of RN
Resumo:
Este artigo avaliou a influência do vento em diferentes profundidades na circulação de massa líquida da lagoa facultativa da estação de tratamento de esgotos do município de Álvares Florence, em São Paulo, Brasil, por meio de flutuadores com diferentes dimensões (15, 25 e 35 cm de comprimento). Por meio de um método simples, prático e de baixo custo, foi possível verificar o sentido de circulação da lagoa, o qual, por sua vez, está relacionado com a direção dos ventos.
Resumo:
Physico-chemical and microbiological parameters were evaluated before and after applying an electrolytic process to effluents of a stabilization lagoon, in the presence or absence of salt. Chlorine generation and bactericidal properties of the treatments were studied following two experiments. Effluent pH increased with electrolysis time. In the absence of salt, 20 min electrolysis resulted in a COD (Chemical Oxygen Demand) reduction of 44%, along with ca. 99.9% (3 log10 cfu/mL) reduction in total coliforms, heterotrophic bacteria and Escherichia coli. These results indicated that the electrolytic process is a promising complementary technology to improve effluent quality for stabilization lagoons.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
A ruptura do ligamento cruzado cranial é uma das principais doenças ortopédicas que afetam os cães. Muitas técnicas cirúrgicas foram descritas no intuito de aliviar a dor, restaurar a estabilidade biomecânica do joelho e prevenir a progressão da osteoartrite. Fáscia lata, fio de poliéster trançado e fio de poliamida foram empregados na estabilização do joelho após excisão do ligamento cruzado cranial em cães, os quais foram submetidos à avaliação radiográfica e macroscópica da articulação. Neste estudo, foram utilizados 18 cães com massa corporal superior a 15Kg (peso médio - 19,67kg), separados em 3 grupos eqüitativos correspondentes a cada técnica, avaliados durante 30 e 60 dias. Ao exame radiográfico, independentemente de grupo, os cães apresentaram evidência de efusão articular moderada a severa, distensão da cápsula articular e, na maioria dos casos, ausência de sinais de doença articular degenerativa. Ao exame macroscópico da articulação do joelho observou-se espessamento da cápsula articular e tecidos moles periarticulares, erosão da cartilagem articular dos côndilos femorais em todos os grupos e afrouxamento dos fios nos cães submetidos às técnicas de estabilização extra-articular com fio de poliéster trançado e fio de poliamida.
Resumo:
Avaliou-se o centro instantâneo de movimento e vetor velocidade após a transecção do ligamento cruzado cranial (LCCr), seguida da substituição ligamentar por retalho de fáscia lata, associada ou não a incisuroplastia troclear (ITR) em nove cães adultos. O joelho direito (GI) foi submetido a ITR e posterior estabilização articular, e o joelho esquerdo submetido somente a substituição ligamentar (GC). Os animais foram avaliados nos períodos pré-operatório, pós-operatório imediato e aos 30, 90 e 180 de pós-operatório, correspondente ao momento de eutanásia de subgrupos de três animais. O centro instantâneo de movimento (CIM) e o vetor velocidade (Vv) resultante foram determinados por meio do deslocamento de pontos a partir da análise radiográfica dos joelhos. Todas as articulações apresentavam CIM e Vv normais antes da transecção do ligamento cruzado cranial. Após a estabilização articular, acompanhada ou não de ITR, observou-se o posicionamento normal do CIM e Vv resultante, em todos os períodos de avaliação, apesar da presença de movimento de gaveta em três animais de GC e dois de GI no pós-operatório imediato, em dois animais de cada grupo, aos 30 dias de avaliação, e em um animal em cada grupo nas avaliações subseqüentes. Conclui-se que a estabilização articular com retalho de fáscia lata, associada ou não a ITR, mantém a integridade biomecânica do joelho, quando considerados o CIM e o Vv.
Resumo:
Avaliaram-se as alterações clínicas e radiográficas em nove cães adultos, após a transecção do ligamento cruzado cranial (LCCr) seguida da substituição ligamentar por retalho de fáscia lata, associada ou não à incisuroplastia troclear (ITR). O joelho direito (GI) foi submetido à ITR e posterior estabilização articular, e o esquerdo somente à substituição ligamentar (GC). Os animais foram avaliados nos períodos pré-operatório, pós-operatório (po) imediato e aos 30, 90 e 180 dias de po, período coincidente com o momento de eutanásia de subgrupos de três cães. A instabilidade articular e o grau de claudicação diminuíram significativamente durante o período de avaliação, apesar da instabilidade persistir durante a flexão articular. Observou-se decréscimo significativo do perímetro muscular da coxa aos 30 e 90 dias p.o. em ambos os grupos. Não foram evidenciadas alterações nos graus de extensão e flexão articulares, na rotação interna da tíbia, na amplitude de movimento articular ou de doença articular degenerativa (DAD) durante o período de avaliação em ambos os grupos. Conclui-se que a ITR, associada à técnica de estabilização articular, não produz alterações em nenhuma das variáveis estudadas em cães, quando comparada à estabilização intra-articular, isoladamente.
Resumo:
A técnica TightRope, que procura aperfeiçoar a estabilização extra-capsular com sutura lateral, por meio da realização de mínimas incisões e criação de túneis ósseos em pontos isométricos, que permitem a inserção de mecanismo que anula o movimento de gaveta, além de reduzir a ocorrência de complicações graves. Dessa forma, objetivou-se avaliar a modificação da técnica TightRope em joelhos de cadáveres caninos com a finalidade de disponibilizar um procedimento simples e de custo reduzido para tratamento da Ruptura do ligamento cruzado cranial (RLCCr). Experimentalmente, foram utilizados 20 membros pélvicos de dez cadáveres caninos, provenientes do setor de patologia da Universidade Norte do Paraná, os quais pesavam entre 6,3 e 24kg. Para estabilização do LCCr, rompido intencionalmente, foi adotada a técnica de TightRope modificada utilizando fio de poliamida, cavilha e emprego de um parafuso ortopédico para proporcionar a fixação óssea. Comparando os valores de deslocamento obtidos durante a realização do movimento de gaveta previamente à ruptura do LCCr e após a realização do procedimento cirúrgico, observou-se que a modificação da técnica TightRope promoveu estabilidade significativa para a maioria (12 de 20) dos joelhos testados (P=0,0033). Contudo, essa estabilidade foi inferior, quando comparada à estabilidade do ligamento intacto.
Resumo:
Este trabalho analisa, de forma empírica, no período 1995-2005, os impactos de variações cambiais sobre os preços de exportação no Brasil, desagregados setorialmente, levando em consideração a inserção externa da economia em um contexto de ampliação da internacionalização e reestruturação produtiva. O cálculo dos coeficientes de pass-through é complementado por um exercício de análise fatorial, com o objetivo de verificar se é possível encontrar padrões setoriais definidos. Os resultados indicam maiores repasses em setores produtores de bens de menor conteúdo tecnológico em que o Brasil possui posição comercial relativamente forte, ao passo que parte dos setores produtores de manufaturados apresenta coeficientes de repasse cambial reduzido.
Resumo:
A motivação para a realização deste artigo foi a percepção de que o movimento de preços dos imóveis em Natal apresentava componentes que precisavam ser investigados, notadamente o influxo de capital estrangeiro, sobretudo para aplicação nos setores de turismo e imobiliário e o comportamento do crédito imobiliário. O objetivo do trabalho é examinar a evolução dos preços no mercado de imóveis da cidade no período 2005; 2010. Os indicadores levantados permitiram uma coleta de evidências suficiente para ampliar o grau de confiança nas hipóteses de que, de fato: a) ocorreu uma bolha no mercado de imóveis no triênio 2005; 2007; b) a bolha não implodiu no biênio 2009; 2010, após a crise financeira de 2008, pois o movimento de alta de preços se manteve tanto nos imóveis vendidos na planta quanto nos imóveis prontos.