986 resultados para Power series
Resumo:
v. 1. The factory buildings / W. L. Case -- v. 8. The power plant / D. M. Myers. [c1920] -- v. 9. The mechanical equipment / J. W. Roe. [c1922]
Resumo:
v.1-8. France / M. Guizot and Madame Guizot de Witt. -- v.9-12. England / J.R. Green. -- v.13-15. United States, from the landing of Columbus to the signing of the peace protocol with Spain / Julian Hawthorne. -- v.16-17. Russia / Alfred Rambaud. -- v. 18-19. Mexico and the life of the conqueror Fernando Cortes / W.H. Prescott. -- v.20-21. Peru / W.H. Prescott. -- v. 22. Spain and her colonies / Archibald Wilberforce. -- v. 23. Germany / S. Baring-Gould. -- v.24. Austria: its rise and present power / J.S.C. Abbott. -- v.25. Italy / J.S.C. Abbott. -- v.26. Turkey / E.L. Clark. -- v.27. Egypt / J.C. McCoan. -- v.28. China / D.C. Boulger. -- v.29. Japan / Walter Dickson. -- v.30. Ancient history from the remotest times to the overthrow of the western empire, A.D. 476 / Leonhard Schmitz.
Resumo:
Mode of access: Internet.
Resumo:
Vector error-correction models (VECMs) have become increasingly important in their application to financial markets. Standard full-order VECM models assume non-zero entries in all their coefficient matrices. However, applications of VECM models to financial market data have revealed that zero entries are often a necessary part of efficient modelling. In such cases, the use of full-order VECM models may lead to incorrect inferences. Specifically, if indirect causality or Granger non-causality exists among the variables, the use of over-parameterised full-order VECM models may weaken the power of statistical inference. In this paper, it is argued that the zero–non-zero (ZNZ) patterned VECM is a more straightforward and effective means of testing for both indirect causality and Granger non-causality. For a ZNZ patterned VECM framework for time series of integrated order two, we provide a new algorithm to select cointegrating and loading vectors that can contain zero entries. Two case studies are used to demonstrate the usefulness of the algorithm in tests of purchasing power parity and a three-variable system involving the stock market.
Resumo:
We consider the problems of computing the power and exponential moments EXs and EetX of square Gaussian random matrices X=A+BWC for positive integer s and real t, where W is a standard normal random vector and A, B, C are appropriately dimensioned constant matrices. We solve the problems by a matrix product scalarization technique and interpret the solutions in system-theoretic terms. The results of the paper are applicable to Bayesian prediction in multivariate autoregressive time series and mean-reverting diffusion processes.
Resumo:
This article analyses the complex process that deracialised and democratised South African football between the early 1970s and 1990s. Based mainly on archival documents, it argues that growing isolation from world sport, exemplified by South Africa's expulsion from the Olympic movement in 1970 and FIFA in 1976, and the reinvigoration of the liberation struggle with the Soweto youth uprising triggered a process of gradual desegregation in the South African professional game. While Pretoria viewed such changes as a potential bulwark against rising black militancy, white football and big business had their own reasons for eventually supporting racial integration, as seen in the founding of the National Soccer League. As negotiations for a new democratic South Africa began in earnest between the African National Congress (ANC) and the National Party (NP) in the latter half of the 1980s, transformations in football and politics paralleled and informed each other. Previously antagonistic football associations began a series of 'unity talks' between 1985 and 1986 that eventually culminated in the formation of a single, non-racial South African Football Association in December 1991, just a few days before the Convention for a Democratic South Africa (CODESA) opened the process of writing a new post-apartheid constitution. Finally, three decades of isolation came to an end as FIFA welcomed South Africa back into world football in 1992 - a powerful example of the seemingly boundless potential of a liberated and united South Africa ahead of the first democratic elections in 1994.
Resumo:
Generation of picosecond pulses with a peak power in excess of 7W and a duration of 24ps from a gain-switched InGaN diode laser is demonstrated for the first time.
Resumo:
This chapter discusses the current state of biomass-based combined heat and power (CHP) production in the UK. It presents an overview of the UK's energy policy and targets which are relevant to the deployment of biomass-based CHP and summarises the current state for renewable, biomass and CHP. A number of small-scale biomass-based CHP projects are described while providing some indicative capital costs for combustion, pyrolysis and gasification technologies. For comparison purposes, it presents an overview of the respective situation in Europe and particularly in Sweden, Finland and Denmark. There is also a brief comment about novel CHP technologies in Austria. Finally it draws some conclusions on the potential of small-scale biomass CHP in the UK. © 2011 Woodhead Publishing Limited All rights reserved.
Resumo:
Two-way power flow is nothing new and has been in practical use using line commutated converters for at least 50 years. With these types of converters, reversal of power flow can be achieved by increasing the firing angle of the devices beyond 90 degrees thus producing a negative DC voltage. Line commutated converters have several known disadvantages including: the direct current cannot be reversed, the power factor decreases when the firing angle increases and the harmonics are high on the line current. To tackle the above problems a forced commutated converter can be used. The power factor can be unity and the harmonics can be reduced. Many researchers have used PWM with different control techniques to serve the above purposes. In each converter arm, they used a forced commutated device with an antiparallel diode. Under the rectification mode of operation the current path is preponderantly through the diodes and under the inverter operation the current flows preponderantly through the forced commutated devices. Although their results were encouraging and gave a unity power factor with nearly sinusoidal current, the main disadvantage was that there were difficulties in controlling the power factor when the system is needed to operate at lagging or leading power factor. In this work, a new idea was introduced by connecting two GTOs antiparallel instead of a diode and a GTO. A single phase system using two GTO converters which are connected in series was built. One converter operates as a rectifier and the other converter operates as an inverter. In the case of the inversion mode and in each inverter arm one GTO is operated as a diode simply by switching it always on and the other antiparallel GTO is operated as a normal device to carry the inverter current. In case of the rectification mode, in each arm one GTO is always off and the other GTP is operated as a controlled device. The main advantage is that the system can be operated at lagging or leading power factor.
Resumo:
PURPOSE: To evaluate theoretically three previously published formulae that use intra-operative aphakic refractive error to calculate intraocular lens (IOL) power, not necessitating pre-operative biometry. The formulae are as follows: IOL power (D) = Aphakic refraction x 2.01 [Ianchulev et al., J. Cataract Refract. Surg.31 (2005) 1530]; IOL power (D) = Aphakic refraction x 1.75 [Mackool et al., J. Cataract Refract. Surg.32 (2006) 435]; IOL power (D) = 0.07x(2) + 1.27x + 1.22, where x = aphakic refraction [Leccisotti, Graefes Arch. Clin. Exp. Ophthalmol.246 (2008) 729]. METHODS: Gaussian first order calculations were used to determine the relationship between intra-operative aphakic refractive error and the IOL power required for emmetropia in a series of schematic eyes incorporating varying corneal powers, pre-operative crystalline lens powers, axial lengths and post-operative IOL positions. The three previously published formulae, based on empirical data, were then compared in terms of IOL power errors that arose in the same schematic eye variants. RESULTS: An inverse relationship exists between theoretical ratio and axial length. Corneal power and initial lens power have little effect on calculated ratios, whilst final IOL position has a significant impact. None of the three empirically derived formulae are universally accurate but each is able to predict IOL power precisely in certain theoretical scenarios. The formulae derived by Ianchulev et al. and Leccisotti are most accurate for posterior IOL positions, whereas the Mackool et al. formula is most reliable when the IOL is located more anteriorly. CONCLUSION: Final IOL position was found to be the chief determinant of IOL power errors. Although the A-constants of IOLs are known and may be accurate, a variety of factors can still influence the final IOL position and lead to undesirable refractive errors. Optimum results using these novel formulae would be achieved in myopic eyes.
Resumo:
There are several methods of providing series compensation for transmission lines using power electronic switches. Four methods of series compensation have been examined in this thesis, the thyristor controlled series capacitor, a voltage sourced inverter series compensator using a capacitor as the series element, a current sourced inverter series compensator and a voltage sourced inverter using an inductor as the series element. All the compensators examined will provide a continuously variable series voltage which is controlled by the switching of the electronic switches. Two of the circuits will offer both capacitive and inductive compensation, the thyristor controlled series capacitor and the current sourced inverter series compensator. The other two will produce either capacitive or inductive series compensation. The thyristor controlled series capacitor offers the widest range of series compensation. However, there is a band of unavailable compensation between 0 and 1 pu capacitive compensation. Compared to the other compensators examined the harmonic content of the compensating voltage is quite high. An algebraic analysis showed that there is more than one state the thyristor controlled series capacitor can operate in. This state has the undesirable effect of introducing large losses. The voltage sourced inverter series compensator using a capacitor as the series element will provide only capacitive compensation. It uses two capacitors which increase the cost of the compensator significantly above the other three. This circuit has the advantage of very low harmonic distortion. The current sourced inverter series compensator will provide both capacitive and inductive series compensation. The harmonic content of the compensating voltage is second only to the voltage sourced inverter series compensator using a capacitor as the series element. The voltage sourced inverter series compensator using an inductor as the series element will only provide inductive compensation, and it is the least expensive compensator examined. Unfortunately, the harmonics introduced by this circuit are considerable.
Resumo:
Wireless power transmission technology is gaining more and more attentions in city transportation applications due to its commensurate power level and efficiency with conductive power transfer means. In this paper, an inductively coupled wireless charging system for 48V light electric vehicle is proposed. The power stages of the system is evaluated and designed, including the high frequency inverter, the resonant network, full bridge rectifier, and the load matching converter. Small signal modeling and linear control technology is applied to the load matching converter for input voltage control, which effectively controls the wireless power flow. The prototype is built with a dsPIC digital signal controller; the experiments are carried out, and the results reveal nature performances of a series-series resonant inductive power charger in terms of frequency, air-gap length, power flow control, and efficiency issues.
Resumo:
This thesis examined solar thermal collectors for use in alternative hybrid solar-biomass power plant applications in Gujarat, India. Following a preliminary review, the cost-effective selection and design of the solar thermal field were identified as critical factors underlying the success of hybrid plants. Consequently, the existing solar thermal technologies were reviewed and ranked for use in India by means of a multi-criteria decision-making method, the Analytical Hierarchy Process (AHP). Informed by the outcome of the AHP, the thesis went on to pursue the Linear Fresnel Reflector (LFR), the design of which was optimised with the help of ray-tracing. To further enhance collector performance, LFR concepts incorporating novel mirror spacing and drive mechanisms were evaluated. Subsequently, a new variant, termed the Elevation Linear Fresnel Reflector (ELFR) was designed, constructed and tested at Aston University, UK, therefore allowing theoretical models for the performance of a solar thermal field to be verified. Based on the resulting characteristics of the LFR, and data gathered for the other hybrid system components, models of hybrid LFR- and ELFR-biomass power plants were developed and analysed in TRNSYS®. The techno-economic and environmental consequences of varying the size of the solar field in relation to the total plant capacity were modelled for a series of case studies to evaluate different applications: tri-generation (electricity, ice and heat), electricity-only generation, and process heat. The case studies also encompassed varying site locations, capacities, operational conditions and financial situations. In the case of a hybrid tri-generation plant in Gujarat, it was recommended to use an LFR solar thermal field of 14,000 m2 aperture with a 3 tonne biomass boiler, generating 815 MWh per annum of electricity for nearby villages and 12,450 tonnes of ice per annum for local fisheries and food industries. However, at the expense of a 0.3 ¢/kWh increase in levelised energy costs, the ELFR increased saving of biomass (100 t/a) and land (9 ha/a). For solar thermal applications in areas with high land cost, the ELFR reduced levelised energy costs. It was determined that off-grid hybrid plants for tri-generation were the most feasible application in India. Whereas biomass-only plants were found to be more economically viable, it was concluded that hybrid systems will soon become cost competitive and can considerably improve current energy security and biomass supply chain issues in India.
Resumo:
2010. július 20-án megkezdte működését a magyar áramtőzsde, a HUPX. 2010. augusztus 16-án az első napokban tapasztalt 45-60 euró megawattórás ár helyett egyes órákban 2999 eurós árral szembesültek a piaci szereplők. A kiemelkedően magas árak megjelenése nem szokatlan az áramtőzsdéken a nemzetközi tapasztalatok szerint, sőt a kutatások kiemelten foglalkoznak az ún. ártüskék okainak felkutatásával, valamint megjelenésük kvantitatív és kvalitatív elemzésével. A cikkben a szerző bemutatja, milyen eredmények születtek a kiugró árak statisztikai vizsgálatai során a szakirodalomban, illetve azok következtetései hogyan állják meg a helyüket a magyar árak idősorát figyelembe véve. A szerző bemutat egy modellkeretet, amely a villamosenergia-árak viselkedését a hét órái szerint periodikusan váltakozó paraméterű eloszlásokkal írja le. A magyar áramtőzsde rövid története sajnos nem teszi lehetővé, hogy a hét minden órájára külön áreloszlást illeszthessünk. A szerző ezért a hét óráit két csoportba sorolja az ár eloszlásának jellege alapján: az ártüskék megjelenése szempontjából kockázatos és kevésbé kockázatos órákba. Ezután a HUPX-árak leírására felépít egy determinisztikus, kétállapotú rezsimváltó modellt, amellyel azonosítani lehet a kockázatos és kevésbé kockázatos órákat, valamint képet kaphatunk az extrém ármozgások jellegéről. / === / On 20th July, 2010 the Hungarian Power Exchange, the HUPX started its operation. On 16th August in certain hours the markets participants faced € 2,999 price instead of in the first days experienced 45-60 euros/mwh. According to the international experiences the appearance of the extremely high prices hasn’t been unusual in the power exchanges, the researches have focused exploring the causes of the so-called spikes and quantitative and qualitative analysis of those appearances. In this article the author describes what results were determined on statistical studies of outstanding prices in the literature, and how their conclusions stand up into account the time series of the Hungarian prices. The author presents a model framework which describes the behavior of electricity prices in the seven hours of periodically varying parameters. Unfortunately the brief history of the Hungarian Power Exchange does not allow to suit specific prices for each hour of week. Therefore the author classifies the hours of the week in the two groups based on the nature of price dispersion: according to the appearance of spikes to risky and less risky classes. Then for describing the HUPX prices the author builds a deterministic two-state, regime-changing model, which can be identified the risky and less risky hours, and to get a picture of the nature of extreme price movements.