993 resultados para Power Doppler ultrasound


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Twenty eight Mediterranean buffaloes bulls were scanned with real-time ultrasound (RTU), slaughtered, and fabricated into retail cuts to determine the potential for ultrasound measures to predict carcass retail yield. Ultrasound measures of fat thickness, ribeye area and rump fat thickness were recorded three to five days prior to slaughter. Carcass measurements were taken, and one side of each carcass was fabricated into retail cuts. Stepwise regression analysis was used to compare possible models for prediction of either kilograms or percent retail product from carcass mesaurements and ultrasound measures. Results indicate that possible prediction models for percent or kilograms of retail products using RTU measures were similar in their predictive power and accuracy when compared to models derived from carcass measurements. Both fat thickness and ribeye area were over-predicted when measured ultrasonically compared to measurements taken on the carcass in the cooler. The mean absolute differences for both traits are larger than the mean differences, indicating that some images were interpreted to be larger and some smaller than actual carcass measurements. Ultrasound measurements of REA and FT had positive correlations with carcass measures of the same traits (r=.96 for REA and r=.99 for FT). Standard errors of prediction currently are being used as the standard to certify ultrasound technicians for accuracy. Regression equations using live weight (LW), rib eye area (REAU) and subcutaneous fat thickness (FTU) between 12(th) and 13 (th) ribs and also over the biceps femoris muscle (FTP8) by ultrasound explained 95% of the variation in the hot carcass weight when measure immediately before slaughter.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Temporal and spatial acoustic intensity (SATA) of therapeutic ultrasound (US) equipment should be monitored periodically. In order to evaluate the conditions of US equipment in use in the city of Piracicaba-Sao Paulo, Brazil, 31 machines - representing all Brazilian manufacturers - were analysed under continuous and pulsed conditions at a frequency of 1 MHz. Data about temporal and spatial acoustic intensity were collected and the use of equipment was surveyed. Intensities of 0.1, 0.2, 0.5, 0.8, 1.0, 1.5, 2.0, 2.5 and 3.0 Wcm -2, indicated on the equipment panel were analysed using a previously calibrated digital radiation pressure scale, model UPM-DT-1 (Ohmic Instruments Co). The acoustic intensity (I) results were expressed as superior and inferior quartile ranges for transducers with metal surfaces of 9 cm 2 and an effective radiation area (ERA) Of 4 cm 2. The results under continuous conditions were: I 0.1 = -20.0% and -96%. I 0.2 = -3.1% and -83.7%. I 0.5 = -35.0% and -86.5%. I 0.8 = -37.5% and -71.0%. I 2.5 = -49.0% and -69.5%. I 3.0 = -58.1% and -77.6%. For pulsed conditions, intensities were: I 0.1 = -40.0% and -86.2%. I 1.0 = -50.0% and -86.5%. I 1.5 = -62.5% and -82.5%. I 2.0 = -62.5% and -81.6%. I 2.5 = -64.7% and -88.8%. I 3.0 = -87.1% and -94.8%. In reply to the questionnaire drawn up to check the conditions of use of equipment, all users reported the use of hydrosoluble gel as a coupling medium and none had carried out previous calibrations. Most users used intensities in the range of 0.4. to 1.0 Wcm -2 and used machines for 300 to 400 minutes per week. The majority of machines had been bought during the previous seven years and weekly use ranged from less than 100 minutes to 700 minutes (11 hours 40 minutes). Findings confirm previous observations of discrepancy between the intensity indicated on the equipment panel and that emitted by the transducer and highlight the necessity for periodic evaluations of US equipment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the shape of dental cavities made with the CVDentus® system using different ultrasound power levels. One standard cavity was made on the buccal aspect of 15 bovine incisors with a CVDentus® cylindrical bur (82142). The sample was divided into three groups: G1 - ultrasound with power II; G2 - ultrasound with power III; and G3 - ultrasound with power IV. A standardizing device was used to obtain standardized preparations and ultrasound was applied during one minute in each dental preparation. The cavities were sectioned in the middle, allowing observation of the cavity's profile with a magnifying glass, and width and depth measurement using the Leica Qwin program. The Kruskal-Wallis (p < 0.05) and Dunn statistical analyses demonstrated differences between the dental cavity shapes when powers III and IV were used. However, the cavities that were made with power III presented dimensions similar to those of the bur used for preparation. We concluded that the power recommended by the manufacturer (III) is the most adequate for use with the CVDentus® system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electric propulsion is now a succeful method for primary propulsion of deep space long duration missions and for geosyncronous satellite attitude control. Closed Drift Thruster, so called Hall Thruster or SPT (Stationary Plasma Thruster), was primarily conceived in USSR (the ancient Soviet Union) and, since then, it has been developed by space agencies, space research institutes and industries in several countries such as France, USA, Israel, Russian Federation and Brazil. In this work we present the main features of the Permanent Magnet Hall Thruster (PMHT) developed at the Plasma Laboratory of the University of Brasilia. The idea of using an array of permanent magnets, instead of an electromagnet, to produce a radial magnetic field inside the plasma channel of the thruster is very significant. It allows the development of a Hall Thruster with power consumption low enough to be used in small and medium size satellites. Description of a new vacuum chamber used to test the second prototype of the PMHT (PHALL II) will be given. PHALL II has an aluminum plasma chamber and is smaller with 15 cm diameter and will contain rare earth magnets. We will show plasma density and temperature space profiles inside and outside the thruster channel. Ion temperature measurements based on Doppler broadening of spectral lines and ion energy measurements are also shown. Based on the measured plasma parameters we constructed an aptitude figure of the PMHT. It contains the specific impulse, total thrust, propellant flow rate and power consumption necessary for orbit raising of satellites. Based on previous studies of geosyncronous satellite orbit positioning we perform numerical simulations of satellite orbit raising from an altitude of 700 km to 36000 km using a PMHT operating in the 100 mN - 500 mN thrust range. In order to perform these calculations integration techniques were used. The main simulation paraters were orbit raising time, fuel mass, total satellite mass, thrust and exaust velocity. We conclude comparing our results with results obtainned with known space missions performed with Hall Thrusters. © 2008 by the American Institute of Aeronautics and Astronautics, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes a method to determine iron in samples of fish feed and feces using ultrasound in the extraction of the analyte and in subsequent quantification by flame atomic absorption spectrometry. Using HCl 0.10 mol L -1 as the extraction solution, the optimal conditions of extraction were found to be: granulometry of the sample <60 μm; a sonication time of five cycles of 10 s and sonication power of 136 W. The method was applied in studies of the availability of iron in four food sources used in the diet of Nile Tilapia. The results obtained with the proposed extraction method allowed us to calculate the coefficients of apparent digestibility of iron in the food sources, which was not possible when using results obtained from samples mineralized by acid digestion. © Springer Science+Business Media, LLC 2008.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: This study aimed to evaluate the characteristics of the brain and vascular indicesof the middle cerebral artery of canine foetuses. Methods: Twenty-five bitches were selected. Tissue development, echogenicity, echotexture and brain echobiometric data were studied, and the major structures were identified between the 5th and 8th gestational weeks. The area and volume of the brain mass (BMA and BMV), cranial area and volume (AC and VC), brain mass index (BMI) and brain volume index (BVI) were determined. A single ultrasound examination was performed during each studied week (6th, 7th and 8th). Doppler ultrasonography was performed to assess the maximum and minimum velocity, resistance and pulsatility index of middle cerebral artery of the foetuses. Results: Echoencephalography was performed to evaluate the morphological characteristics of the central nervous system. Cerebral echobiometry indicated an increase in area and volume of the hemispheres and cranium (P<0·001) but no changes in BMI or BVI over the gestational period studied. Doppler ultrasonography identified increases in peak systolic velocity (P=0·0188) and end diastolic velocity (P=0·0274) and decreases in resistance index (P=0·0002) and pulsatility index (P<0·001). Clinical Significance: Echoencephalography and spectral Doppler ultrasonography of the middle cerebral artery in canine foetuses might be a useful technique for prenatal care. © 2013 British Small Animal Veterinary Association.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study is aimed to evaluate the efficiency of ultrasound-assisted extraction (UAE) as a simple strategy focused on sample preparation for metal determination in biological samples. The extraction of sodium and potassium extraction was carried out from swine feed followed by determination of the concentration of these metals by flame atomic emission spectrometry (FAES). The experiment was performed to cover the study of the variables influencing the extraction process and its optimal conditions (sample mass, particle size, acid concentration, sonication time and ultrasound power); the determination of these analytical characteristics and method validation using certified reference material; and the analysis of pre-starter diets. The optimal conditions established conditions were as follows: mass: 100 mg, particle size:<60 μm, acid concentration: 0.10 mol L-1 HCl, sonication time: 50 s and ultrasound power: 102 W. The proposed method (UAE) was applied in digestibility assays of those nutrients present in different piglet pre-starter feeds and their results proved to be compatible with those obtained from mineralized samples (P < 0.05). The ultrasound extraction method was demonstrated to be an excellent alternative for handless sampling and operational costs and the method also has the advantage of does not generating toxic residues that may negatively affect human health and contaminate the environment. © 2013 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Este trabalho teve como objetivo descrever as características ultrassonográficas uterinas e ovarianas, e dopplervelocimétricas das suas artérias nos dias periovulatórios em cadelas. Quinze ciclos estrais em 10 animais foram avaliados. As características ultrassonográficas, índices de resistência (IR) e índices de pulsatilidade (IP) do útero e dos ovários em cada animal foram registrados 5 dias antes e depois da ovulação (D0). Os dados foram analisados estatisticamente e os resultados foram expressos em média ± erro padrão da média (P<0,05). Como resultados as características ultrassonográficas uterinas foram semelhantes em todos os ciclos e dias avaliados, tendo o corpo uterino um diâmetro médio de 0,85±0,02cm. Foi observado um aumento no volume dos ovários e nos diâmetros dos folículos, tendo os ovários um volume de 0,64±0,06cm3, e a cavidade dos folículos um diâmetro de 0,46±0,01cm no dia da ovulação. Após a ovulação, foi observado colapso dos folículos somente em alguns ciclos. A perfusão sanguínea uterina diminuiu dois dias antes da ovulação e permaneceu inalterada até a ovulação. Após a ovulação, houve um aumento gradual na perfusão das artérias uterinas e ovarianas, direcionando o fluxo de sangue para os ovários e aumentando a perfusão da artéria intra-ovariana um dia após a ovulação. Conclui-se que características específicas são observadas na imagem ultrassonográfica uterina e ovariana, e dopplervelocimétricas de suas artérias nos dias periovulatórios, e quando associadas permitem estimar com mais precisão o dia da ovulação.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O objetivo do trabalho foi estabelecer a relação entre a ecobiometria renal com medidas de conformação corporal como a distância atlanto-coccígea (DAC) e a altura (H) de cães adultos saudáveis, obtendo-se parâmetros de normalidade para avaliar o tamanho e volume renal, bem como estabelecer valores de referência para avaliar a perfusão sanguínea dos rins por meio do índice de resistividade (IR) e do índice de pulsatilidade (IP) do ramo principal da artéria renal. No estudo foram utilizados 22 cães adultos sem raça definida, sendo 11 machos e 11 fêmeas. Os animais foram previamente aferidos quanto a DAC e a H. Os exames ultra-sonográficos foram realizados com um aparelho HDI 4000 PHILIPS munido de um transdutor microconvexo multifreqüêncial (5-8 MHz), dispositivos Doppler Colorido e Doppler de Fluxo. Os animais foram posicionados em decúbito lateral direito ou esquerdo, de acordo com o rim a ser avaliado. Os diâmetros longitudinal (DL) e dorsoventral (DDV) dos rins foram mensurados na secção longitudinal e, o diâmetro transversal (DT) foi aferido no plano transversal. O volume (V) foi calculado automaticamente pelo software do ultra-som. Com o uso do Triplex Doppler, o IR e o IP das artérias renais direita e esquerda foram obtidos. Todos os dados foram apresentados em média ± EPM. Análises de regressão linear foram realizadas tendo o DL, DDV, DT e V como variáveis dependentes e a DAC e H como variáveis independentes. Os IR e IP dos rins direito e esquerdo foram comparados pelo teste t de Student. A DAC variou de 54-78cm para machos e 37-71cm para fêmeas e a altura variou entre 34-64 cm para os machos e 24-57cm para as fêmeas. As médias obtidas para DL, DDV, DT e V dos rins esquerdo e direito foram: 5,24±0,27cm, 3,07±0,15cm, 3,07±0,9cm, 28,01±3,4mL e 4,50±0,19cm, 2,88±0,14cm, 2,71±0,15cm, 21,27±2,6mL, respectivamente. As análises de regressão linear entre as medidas lineares e volume renal com a DAC e a H foram significativas para os interceptos e coeficientes de regressão (P<0,01). Houve diferenças estatísticas quando comparado os IR e IP entre os rins direito e esquerdo (P=0,001), sendo que as médias para IR e IP dos rins esquerdo e direito foram 0,62±0,08; 1,34±0,18 e 0,70±0,06; 1,62±0,13; respectivamente. Os dados obtidos no presente trabalho podem auxiliar na avaliação do tamanho, volume e perfusão dos rins de cães adultos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O objetivo deste estudo foi avaliar, por meio da ultrassonografia convencional modo B, as características sonográficas e a biometria dos rins de fetos caninos, bem como determinar os índices vasculares da artéria renal dos conceptos ao Doppler Triplex. Foram utilizadas 24 fêmeas Shi-tzu e Pugs pesando de quatro a 10 kg e com idade entre quatro e seis anos. Ao modo B, a ecobiometria renal fetal, a regularidade da superfície renal, a ecotextura e a relação córtico-medular foram avaliadas durante a quinta, sexta, sétima e oitava semanas gestacionais. Ao Doppler Triplex, durante o mesmo período em que se realizou o exame convencional, foram determinados o pico de velocidade sistólica (PVS), a velocidade diastólica final (EDV) e o índice de resistência vascular (RI) e de pulsatividade (PI). Ao modo B, não foram detectadas alterações em rins fetais, e à ecobiometria renal dos fetos, foi possível determinar medidas renais importantes, verificando-se aumento das biometrias no decorrer do desenvolvimento fetal (P<0,0001). Ao Doppler Triplex, determinaram-se os índices vasculares da artéria renal fetal, sendo que os valores para PSV e EDV aumentaram no decorrer das semanas gestacionais (P<0,05) e permaneceram constantes para PI e RI (P>0,05). Concluiu-se que o modo B e o Doppler Triplex são ferramentas importantes para a avaliação do desenvolvimento renal fetal, com a utilização da ecobiometria renal e avaliação dos indices vasculares da artéria renal de fetos caninos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)