846 resultados para Post-Operating Performance


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The PulseCath iVAC 3L? left ventricular assist device is an option to treat transitory left heart failure or dysfunction post-cardiac surgery. Assisted blood flow should reach up to 3 l/min. In the present in vitro model exact pump flow, depending on various frequencies and afterload was examined. Optimal flow was achieved with inflation/deflation frequencies of about 70-80/min. The maximal flow rate was achieved at about 2.5 l/min with a minimal afterload of 22 mmHg. Handling of the device was easy due to the connection to a standard intra-aortic balloon pump console. With increasing afterload (up to a simulated mean systemic pressure of 66 mmHg) flow rate and cardiac support are in some extent limited.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: To date, there is no quality assurance program that correlates patient outcome to perfusion service provided during cardiopulmonary bypass (CPB). A score was devised, incorporating objective parameters that would reflect the likelihood to influence patient outcome. The purpose was to create a new method for evaluating the quality of care the perfusionist provides during CPB procedures and to deduce whether it predicts patient morbidity and mortality. METHODS: We analysed 295 consecutive elective patients. We chose 10 parameters: fluid balance, blood transfused, Hct, ACT, PaO2, PaCO2, pH, BE, potassium and CPB time. Distribution analysis was performed using the Shapiro-Wilcoxon test. This made up the PerfSCORE and we tried to find a correlation to mortality rate, patient stay in the ICU and length of mechanical ventilation. Univariate analysis (UA) using linear regression was established for each parameter. Statistical significance was established when p < 0.05. Multivariate analysis (MA) was performed with the same parameters. RESULTS: The mean age was 63.8 +/- 12.6 years with 70% males. There were 180 CABG, 88 valves, and 27 combined CABG/valve procedures. The PerfSCORE of 6.6 +/- 2.4 (0-20), mortality of 2.7% (8/295), CPB time 100 +/- 41 min (19-313), ICU stay 52 +/- 62 hrs (7-564) and mechanical ventilation of 10.5 +/- 14.8 hrs (0-564) was calculated. CPB time, fluid balance, PaO2, PerfSCORE and blood transfused were significantly correlated to mortality (UA, p < 0.05). Also, CPB time, blood transfused and PaO2 were parameters predicting mortality (MA, p < 0.01). Only pH was significantly correlated for predicting ICU stay (UA). Ultrafiltration (UF) and CPB time were significantly correlated (UA, p < 0.01) while UF (p < 0.05) was the only parameter predicting mechanical ventilation duration (MA). CONCLUSIONS: CPB time, blood transfused and PaO2 are independent risk factors of mortality. Fluid balance, blood transfusion, PaO2, PerfSCORE and CPB time are independent parameters for predicting morbidity. PerfSCORE is a quality of perfusion measure that objectively quantifies perfusion performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To evaluate the incidence of presumed endophthalmitis (EO) after intravitreal injection (IVI) of anti-vascular endothelial growth factor agents performed in the operating room. METHODS: Retrospective study at 2 Swiss eye hospitals between 2004 and 2012. Hospital records were used to identify patients treated with an IVI of an anti-vascular endothelial growth factor agent between 2004 and 2012 and those treated for EO, defined as any intraocular inflammation treated with intravitreal antibiotics. All IVIs were performed using standard sterile technique in a Swiss Class 1 operating room. No patient received preinjection topical antibiotics. Postinjection topical antibiotics were used only in one hospital. RESULTS: A total of 40,011 IVIs were performed at the 2 centers during the study period. Of the IVIs, ranibizumab was injected in 36,398 (91%), bevacizumab in 3,518 (9%), aflibercept in 89 (0.2%), and pegaptanib in 6 (<0.1%). Three cases of post-IVI presumed EO occurred, yielding a combined incidence of 0.0075% per injection (95% confidence interval: 0.0026-0.0220%) or 1 case per 13,337 IVIs. Two of the three cases of EO occurred in patients using post-IVI antibiotics. All three cases followed ranibizumab injection and were culture negative by anterior chamber tap or vitreous biopsy. CONCLUSION: The risk of EO after IVI performed under the sterile conditions of the operating room was very low.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Resum en anglès del projecte de recerca L'empresa xarxa a Catalunya. TIC, productivitat, competitivitat, salaris i beneficis a l'empresa catalana té com a objectiu principal constatar que la consolidació d'un nou model estratègic, organitzatiu i d'activitat empresarial, vinculat amb la inversió i l'ús de les TIC (o empresa xarxa), modifica substancialment els patrons de comportament dels resultats empresarials, en especial la productivitat, la competitivitat, les retribucions dels treballadors i el benefici. La contrastació empírica de les hipòtesis de treball l'hem feta per mitjà de les dades d'una enquesta a una mostra representativa de 2.038 empreses catalanes. Amb la perspectiva de l'impacte de la inversió i l'ús de les TIC no s'aprecia una relació directa entre els processos d'innovació digital i els resultats de l'activitat de l'empresa catalana. En aquest sentit, hem hagut de segmentar el teixit productiu català per a buscar les organitzacions en què el procés de coinnovació tecnològica digital i organitzativa és més present i en què la intensitat de l'ús del coneixement és un recurs molt freqüent per a poder copsar impactes rellevants en els principals resultats empresarials. Això és així perquè l'economia catalana, avui, presenta una estructura productiva dual.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to examine the effect of an individualized overground walking interval training on gait performance [i.e., speed and energy cost (C(w))] in healthy elderly individuals. Twenty-two older adults were assigned to either a training group (TG; n=12, 73.4+/-3.9yr) or a non-training control group (CG; n=10, 70.9+/-9.6yr). TG participated in a 7-week individualized walking interval training at intensities progressing from 50 to 100% of ventilatory threshold (T (VE)). Aerobic fitness [maximal oxygen uptake (V O(2max)) and T (VE)], preferred walking speed (PWS), gross and net C(w) (GC(w) and NC(w), respectively) and relative effort (%V O(2max)) at PWS measured before training (PWS(1)) were assessed prior and following the intervention. All outcomes were measured on a treadmill. Significant improvements in GC(w) (-8%; P=0.007), NC(w) (-12%; P=0.003), relative effort (%V O(2max): -12%; P<0.001) and PWS (+12%; P<0.001) were observed in TG but not in CG (P>0.71). V O(2max) and T (VE) remained unchanged in both groups (P>0.57). Changes in GC(w) at PWS(1) (difference between GC(w) at PWS(1) measured pre and post intervention) were inversely correlated with changes in PWS (difference between pre and post PWS; r=-0.67; P=0.02). The decreased C(w) at PWS(1), with no concomitant improvement in aerobic fitness, represents the main contributing factor for the reduction of the relative effort at this speed. This also allows elderly people to increase their PWS post training. Therefore, the present walking training may be an effective way to improve walking performance and delay mobility impairment in older adults.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ECG criteria for left ventricular hypertrophy (LVH) have been almost exclusively elaborated and calibrated in white populations. Because several interethnic differences in ECG characteristics have been found, the applicability of these criteria to African individuals remains to be demonstrated. We therefore investigated the performance of classic ECG criteria for LVH detection in an African population. Digitized 12-lead ECG tracings were obtained from 334 African individuals randomly selected from the general population of the Republic of Seychelles (Indian Ocean). Left ventricular mass was calculated with M-mode echocardiography and indexed to body height. LVH was defined by taking the 95th percentile of body height-indexed LVM values in a reference subgroup. In the entire study sample, 16 men and 15 women (prevalence 9.3%) were finally declared to have LVH, of whom 9 were of the reference subgroup. Sensitivity, specificity, accuracy, and positive and negative predictive values for LVH were calculated for 9 classic ECG criteria, and receiver operating characteristic curves were computed. We also generated a new composite time-voltage criterion with stepwise multiple linear regression: weighted time-voltage criterion=(0.2366R(aVL)+0.0551R(V5)+0.0785S(V3)+ 0.2993T(V1))xQRS duration. The Sokolow-Lyon criterion reached the highest sensitivity (61%) and the R(aVL) voltage criterion reached the highest specificity (97%) when evaluated at their traditional partition value. However, at a fixed specificity of 95%, the sensitivity of these 10 criteria ranged from 16% to 32%. Best accuracy was obtained with the R(aVL) voltage criterion and the new composite time-voltage criterion (89% for both). Positive and negative predictive values varied considerably depending on the concomitant presence of 3 clinical risk factors for LVH (hypertension, age >/=50 years, overweight). Median positive and negative predictive values of the 10 ECG criteria were 15% and 95%, respectively, for subjects with none or 1 of these risk factors compared with 63% and 76% for subjects with all of them. In conclusion, the performance of classic ECG criteria for LVH detection was largely disparate and appeared to be lower in this population of East African origin than in white subjects. A newly generated composite time-voltage criterion might provide improved performance. The predictive value of ECG criteria for LVH was considerably enhanced with the integration of information on concomitant clinical risk factors for LVH.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Given that firms develop their activities in a network of multiple players, interfirm rivalry is not only a matter of direct competitors, but also of indirect competition. In spite of this, the literature on competitive dynamics tends to focus on analyzing rivalry as an exclusive function of the competitive relationship between a focal firm and its direct rivals. In this article, we extend competitive dynamics literature by considering how focal firms are affected by the relationships of their rivals with third-party firms. Specifically, we study the effect that the multimarket contacts of rivals produces on the performance of the focal firm. Additionally, we incorporate the idea that there are different strategic options for operating in an industry that affect the intensity of multimarket contact externalities. Our results show that multimarket contact among firms causes externalities that indirectly affect firms that are not directly involved in this competitive relationship. We find that multimarket contact externalities differ between and within strategic groups.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The diagnosis of hypertension in children is difficult because of the multiple sex-, age-, and height-specific thresholds to define elevated blood pressure (BP). Blood pressure-to-height ratio (BPHR) has been proposed to facilitate the identification of elevated BP in children. OBJECTIVE: We assessed the performance of BPHR at a single screening visit to identify children with hypertension that is sustained elevated BP. METHOD: In a school-based study conducted in Switzerland, BP was measured at up to three visits in 5207 children. Children had hypertension if BP was elevated at the three visits. Sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) for the identification of hypertension were assessed for different thresholds of BPHR. The ability of BPHR at a single screening visit to discriminate children with and without hypertension was evaluated with receiver operating characteristic (ROC) curve analyses. RESULTS: The prevalence of systolic/diastolic hypertension was 2.2%. Systolic BPHR had a better performance to identify hypertension compared with diastolic BPHR (area under the ROC curve: 0.95 vs. 0.84). The highest performance was obtained with a systolic BPHR threshold set at 0.80 mmHg/cm (sensitivity: 98%; specificity: 85%; PPV: 12%; and NPV: 100%) and a diastolic BPHR threshold set at 0.45 mmHg/cm (sensitivity: 79%; specificity: 70%; PPV: 5%; and NPV: 99%). The PPV was higher among tall or overweight children. CONCLUSION: BPHR at a single screening visit had a high performance to identify hypertension in children, although the low prevalence of hypertension led to a low PPV.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Transthoracic echocardiography (TTE) has been used clinically to disobstruct venous drainage cannula and to optimise placement of venous cannulae in the vena cava but it has never been used to evaluate performance capabilities. Also, little progress has been made in venous cannula design in order to optimise venous return to the heart lung machine. We designed a self-expandable Smartcanula (SC) and analysed its performance capability using echocardiography. METHODS: An epicardial echocardiography probe was placed over the SC or control cannula (CTRL) and a Doppler image was obtained. Mean (V(m)) and maximum (V(max)) velocities, flow and diameter were obtained. Also, pressure drop (DeltaP(CPB)) was obtained between the central venous pressure and inlet to venous reservoir. LDH and Free Hb were also compared in 30 patients. Comparison was made between the two groups using the student's t-test with statistical significance established when p<0.05. RESULTS: Age for the SC and CC groups were 61.6+/-17.6 years and 64.6+/-13.1 years, respectively. Weight was 70.3+/-11.6 kg and 72.8+/-14.4 kg, respectively. BSA was 1.80+/-0.2 m(2) and 1.82+/-0.2 m(2), respectively. CPB times were 114+/-53 min and 108+/-44 min, respectively. Cross-clamp time was 59+/-15 min and 76+/-29 min, respectively (p=NS). Free-Hb was 568+/-142 U/l versus 549+/-271 U/l post-CPB for the SC and CC, respectively (p=NS). LDH was 335+/-73 mg/l versus 354+/-116 mg/l for the SC and CC, respectively (p=NS). V(m) was 89+/-10 cm/s (SC) versus 63+/-3 cm/s (CC), V(max) was 139+/-23 cm/s (SC) versus 93+/-11 cm/s (CC) (both p<0.01). DeltaP(CPB) was 30+/-10 mmHg (SC) versus 43+/-13 mmHg (CC) (p<0.05). A Bland-Altman test showed good agreement between the two devices used concerning flow rate calculations between CPB and TTE (bias 300 ml+/-700 ml standard deviation). CONCLUSIONS: This novel Smartcanula design, due to its self-expanding principle, provides superior flow characteristics compared to classic two stage venous cannula used for adult CPB surgery. No detrimental effects were observed concerning blood damage. Echocardiography was effective in analysing venous cannula performance and velocity patterns.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Supported by IEEE 802.15.4 standardization activities, embedded networks have been gaining popularity in recent years. The focus of this paper is to quantify the behavior of key networking metrics of IEEE 802.15.4 beacon-enabled nodes under typical operating conditions, with the inclusion of packet retransmissions. We corrected and extended previous analyses by scrutinizing the assumptions on which the prevalent Markovian modeling is generally based. By means of a comparative study, we singled out which of the assumptions impact each of the performance metrics (throughput, delay, power consumption, collision probability, and packet-discard probability). In particular, we showed that - unlike what is usually assumed - the probability that a node senses the channel busy is not constant for all the stages of the backoff procedure and that these differences have a noticeable impact on backoff delay, packet-discard probability, and power consumption. Similarly, we showed that - again contrary to common assumption - the probability of obtaining transmission access to the channel depends on the number of nodes that is simultaneously sensing it. We evidenced that ignoring this dependence has a significant impact on the calculated values of throughput and collision probability. Circumventing these and other assumptions, we rigorously characterize, through a semianalytical approach, the key metrics in a beacon-enabled IEEE 802.15.4 system with retransmissions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Responses to external stimuli are typically investigated by averaging peri-stimulus electroencephalography (EEG) epochs in order to derive event-related potentials (ERPs) across the electrode montage, under the assumption that signals that are related to the external stimulus are fixed in time across trials. We demonstrate the applicability of a single-trial model based on patterns of scalp topographies (De Lucia et al, 2007) that can be used for ERP analysis at the single-subject level. The model is able to classify new trials (or groups of trials) with minimal a priori hypotheses, using information derived from a training dataset. The features used for the classification (the topography of responses and their latency) can be neurophysiologically interpreted, because a difference in scalp topography indicates a different configuration of brain generators. An above chance classification accuracy on test datasets implicitly demonstrates the suitability of this model for EEG data. Methods: The data analyzed in this study were acquired from two separate visual evoked potential (VEP) experiments. The first entailed passive presentation of checkerboard stimuli to each of the four visual quadrants (hereafter, "Checkerboard Experiment") (Plomp et al, submitted). The second entailed active discrimination of novel versus repeated line drawings of common objects (hereafter, "Priming Experiment") (Murray et al, 2004). Four subjects per experiment were analyzed, using approx. 200 trials per experimental condition. These trials were randomly separated in training (90%) and testing (10%) datasets in 10 independent shuffles. In order to perform the ERP analysis we estimated the statistical distribution of voltage topographies by a Mixture of Gaussians (MofGs), which reduces our original dataset to a small number of representative voltage topographies. We then evaluated statistically the degree of presence of these template maps across trials and whether and when this was different across experimental conditions. Based on these differences, single-trials or sets of a few single-trials were classified as belonging to one or the other experimental condition. Classification performance was assessed using the Receiver Operating Characteristic (ROC) curve. Results: For the Checkerboard Experiment contrasts entailed left vs. right visual field presentations for upper and lower quadrants, separately. The average posterior probabilities, indicating the presence of the computed template maps in time and across trials revealed significant differences starting at ~60-70 ms post-stimulus. The average ROC curve area across all four subjects was 0.80 and 0.85 for upper and lower quadrants, respectively and was in all cases significantly higher than chance (unpaired t-test, p<0.0001). In the Priming Experiment, we contrasted initial versus repeated presentations of visual object stimuli. Their posterior probabilities revealed significant differences, which started at 250ms post-stimulus onset. The classification accuracy rates with single-trial test data were at chance level. We therefore considered sub-averages based on five single trials. We found that for three out of four subjects' classification rates were significantly above chance level (unpaired t-test, p<0.0001). Conclusions: The main advantage of the present approach is that it is based on topographic features that are readily interpretable along neurophysiologic lines. As these maps were previously normalized by the overall strength of the field potential on the scalp, a change in their presence across trials and between conditions forcibly reflects a change in the underlying generator configurations. The temporal periods of statistical difference between conditions were estimated for each training dataset for ten shuffles of the data. Across the ten shuffles and in both experiments, we observed a high level of consistency in the temporal periods over which the two conditions differed. With this method we are able to analyze ERPs at the single-subject level providing a novel tool to compare normal electrophysiological responses versus single cases that cannot be considered part of any cohort of subjects. This aspect promises to have a strong impact on both basic and clinical research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the effectiveness of an educational intervention on malignant hyperthermia with operating room nurses. METHOD A quasi-experimental study, aimed at an educational intervention of short duration with the nursing staff in the operating room of the institution hosting the research in the city of São Paulo, with the participation of 96 professionals. Pre-intervention tests and post-intervention tests were applied, which consisted of a lecture followed by simulation. RESULTS Considering the overall results of the intervention, there was a statistically significant difference (p<0.00). After the educational intervention, there was an increase of the minimum and maximum scores, and average growth of 2.64 points in the knowledge of professionals when compared to the previous step. CONCLUSION The educational intervention strategy favors the concept of the content developed by everyone involved and qualifies professionals to work safely.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To examine the relationship of early serum procalcitonin (PCT) levels with the severity of post-cardiac arrest syndrome (PCAS), long-term neurological recovery and the risk of early-onset infections in patients with coma after cardiac arrest (CA) treated with therapeutic hypothermia (TH). METHODS: A prospective cohort of adult comatose CA patients treated with TH (33°C, for 24h) admitted to the medical/surgical intensive care unit, Lausanne University Hospital, was studied. Serum PCT was measured early after CA, at two time-points (days 1 and 2). The SOFA score was used to quantify the severity of PCAS. Diagnosis of early-onset infections (within the first 7 days of ICU stay) was made after review of clinical, radiological and microbiological data. Neurological recovery at 3 months was assessed with Cerebral Performance Categories (CPC), and was dichotomized as favorable (CPC 1-2) vs. unfavorable (CPC 3-5). RESULTS: From December 2009 to April 2012, 100 patients (median age 64 [interquartile range 55-73] years, median time from collapse to ROSC 20 [11-30]min) were studied. Peak PCT correlated with SOFA score at day 1 (Spearman's R=0.44, p<0.0001) and was associated with neurological recovery at 3 months (peak PCT 1.08 [0.35-4.45]ng/ml in patients with CPC 1-2 vs. 3.07 [0.89-9.99] ng/ml in those with CPC 3-5, p=0.01). Peak PCT did not differ significantly between patients with early-onset vs. no infections (2.14 [0.49-6.74] vs. 1.53 [0.46-5.38]ng/ml, p=0.49). CONCLUSIONS: Early elevations of serum PCT levels correlate with the severity of PCAS and are associated with worse neurological recovery after CA and TH. In contrast, elevated serum PCT did not correlate with early-onset infections in this setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The original and modified Wells score are widely used prediction rules for pre-test probability assessment of deep vein thrombosis (DVT). The objective of this study was to compare the predictive performance of both Wells scores in unselected patients with clinical suspicion of DVT.Methods: Consecutive inpatients and outpatients with a clinical suspicion of DVT were prospectively enrolled. Pre-test DVT probability (low/intermediate/high) was determined using both scores. Patients with a non-high probability based on the original Wells score underwent D-dimers measurement. Patients with D-dimers <500 mu g/L did not undergo further testing, and treatment was withheld. All others underwent complete lower limb compression ultrasound, and those diagnosed with DVT were anticoagulated. The primary study outcome was objectively confirmed symptomatic venous thromboembolism within 3 months of enrollment.Results: 298 patients with suspected DVT were included. Of these, 82 (27.5%) had DVT, and 46 of them were proximal. Compared to the modified score, the original Wells score classified a higher proportion of patients as low-risk (53 vs 48%; p<0.01) and a lower proportion as high-risk (17 vs 15%; p=0.02); the prevalence of proximal DVT in each category was similar with both scores (7-8% low, 16-19% intermediate, 36-37% high). The area under the receiver operating characteristic curve regarding proximal DVT detection was similar for both scores, but they both performed poorly in predicting isolated distal DVT and DVT in inpatients.Conclusion: The study demonstrates that both Wells scores perform equally well in proximal DVT pre-test probability prediction. Neither score appears to be particularly useful in hospitalized patients and those with isolated distal DVT. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Until recently, the hard X-ray, phase-sensitive imaging technique called grating interferometry was thought to provide information only in real space. However, by utilizing an alternative approach to data analysis we demonstrated that the angular resolved ultra-small angle X-ray scattering distribution can be retrieved from experimental data. Thus, reciprocal space information is accessible by grating interferometry in addition to real space. Naturally, the quality of the retrieved data strongly depends on the performance of the employed analysis procedure, which involves deconvolution of periodic and noisy data in this context. The aim of this article is to compare several deconvolution algorithms to retrieve the ultra-small angle X-ray scattering distribution in grating interferometry. We quantitatively compare the performance of three deconvolution procedures (i.e., Wiener, iterative Wiener and Lucy-Richardson) in case of realistically modeled, noisy and periodic input data. The simulations showed that the algorithm of Lucy-Richardson is the more reliable and more efficient as a function of the characteristics of the signals in the given context. The availability of a reliable data analysis procedure is essential for future developments in grating interferometry.