984 resultados para Phasor measurement unit (PMUs)
Resumo:
Aims The excretion of phospholipids in urine may be a marker of the early renal toxicity of the aminoglycoside antibiotics. Urinary phospholipids are formed in myeloid bodies which develop in the lysosomes of proximal tubules during treatment with the aminoglycosides, and overflow into the urine. Methods Published assays were modified in order to measure the total phospholipid concentrations in human urine. Phospholipids were extracted from freeze-dried urine samples, digested in concentrated sulphuric acid, and the inorganic phosphorus content determined by complexing with ammonium molybdate and measuring the absorbance at 820 nm. Ten septicaemic patients treated with gentamicin for 5-7 days had significantly higher urine phospholipid concentrations than 10 healthy untreated control subjects (P<0.0001). There was a negative Linear relationship between phospholipid excretion and creatinine clearance (r(2) = 0.71). Results In 34 patients with acute pyelonephritis, increased phospholipid concentrations were observed prior to treatment compared with healthy controls (P<0.001) and did not alter during treatment with gentamicin. However, the phospholipid concentrations decreased significantly after treatment was completed (P<0.03). Conclusions These studies suggest that urinary phospholipids may indicate early aminoglycoside toxicity but with poor specificity, as many of the infections being treated may themselves be associated with phospholipiduria.
Resumo:
The aim of this study was to confirm that the radiation doses received by attendants who manually restrain infants during fluoroscopic procedures are low. Doses to the hands and neck of three radiologists and three nurses performing or assisting at all the fluoroscopic procedures in a children's hospital were measured for 1 month using thermoluminescent dosemeters. All fluoroscopy on children at this hospital is performed without an antiscatter grid. Total doses for the neck ranged from 20 to 50 mu Sv per week and for hands from 40 to 210 mu Sv per week. These doses were shared by the three radiologists and the three nurses. Individual doses received per staff member are very small when compared with the doses received by interventional radiology staff. Doses received by staff in this study were of the order of 5% of the limit advised by the National Health and Medical Research Council of Australia (NHMRC) for radiation workers. Nurses received larger doses than radiologists and steps will be taken to reduce this dose further.
Resumo:
Analysis of a major multi-site epidemiologic study of heart disease has required estimation of the pairwise correlation of several measurements across sub-populations. Because the measurements from each sub-population were subject to sampling variability, the Pearson product moment estimator of these correlations produces biased estimates. This paper proposes a model that takes into account within and between sub-population variation, provides algorithms for obtaining maximum likelihood estimates of these correlations and discusses several approaches for obtaining interval estimates. (C) 1997 by John Wiley & Sons, Ltd.
Resumo:
PURPOSE: To evaluate the impact of atypical retardation patterns (ARP) on detection of progressive retinal nerve fiber layer (RNFL) loss using scanning laser polarimetry with variable corneal compensation (VCC). DESIGN: Observational cohort study. METHODS: The study included 377 eyes of 221 patients with a median follow-up of 4.0 years. Images were obtained annually with the GDx VCC (Carl Zeiss Med, itec Inc, Dublin, California, USA), along with optic disc stereophotographs and standard automated perimetry (SAP) visual fields. Progression was determined by the Guided Progression Analysis software for SAP and by masked assessment of stereophotographs by expert graders. The typical scan score (TSS) was used to quantify the presence of ARPs on GDx VCC images. Random coefficients models were used to evaluate the relationship between ARP and RNFL thickness measurements over time. RESULTS: Thirty-eight eyes (10%) showed progression over time on visual fields, stereophotographs, or both. Changes in TSS scores from baseline were significantly associated with changes in RNFL thickness measurements in both progressing and nonprogressing eyes. Each I unit increase in TSS score was associated with a 0.19-mu m decrease in RNFL thickness measurement (P < .001) over time. CONCLUSIONS: ARPs had a significant effect on detection of progressive RNFL loss with the GDx VCC. Eyes with large amounts of atypical patterns, great fluctuations on these patterns over time, or both may show changes in measurements that can appear falsely as glaucomatous progression or can mask true changes in the RNFL. (Am J Ophthalmol 2009;148:155-163. (C) 2009 by Elsevier Inc. All rights reserved.)
Resumo:
Purpose. To use 3-dimensional sonography (3DUS) to measure contralateral lung volume and evaluate the potential of this measurement to predict neonatal outcome in isolated congenital diaphragmatic hernia (CDH). Methods. Between January 2002 and December 2004, the contralateral lung volumes of 39 fetuses with isolated CDH were measured via 3DUS using rotational multiplanar imaging. The observed/expected contralateral fetal lung volume ratios (o/eContFLVR) were compared with the lung/head ratio (LHR), observed/expected total fetal lung volume ratio (o/e-TotFLVR), and postnatal outcome. Results. Contralateral lung volumes are less reduced than total lung volumes in CDH. The bias and precision of 3DUS in estimating contralateral lung volumes were 0.99 cm(3) and 1.11 cm(3), respectively, with absolute limits of agreement ranging from -1.19 cm(3) to + 3.17 cm(3). The o/e-ContFLVR was significantly lower in neonatal death cases (median, 0.49 cm(3); range, 0.22-0.99 cm(3)) than in survival cases (median, 0.58 cm(3); range, 0.42-0.92 cm(3) [p < 0.011). Overall accuracy of the o/e-ContFLVR, o/e-TotFLVR, and LHR in predicting neonatal death were 67.7% (21/31), 80.7% (25/31), and 77.4% (24/31), respectively. Conclusion. Although o/e-ContFLVR can be precisely measured with 3DUS and can be used to predict neonatal death in CDH, it is less accurate than LHR and o/e-TotFLVR for that purpose. (C) 2007 Wiley Periodicals, Inc.
Resumo:
Purpose: The objective of this study is to evaluate blood glucose (BG) control efficacy and safety of 3 insulin protocols in medical intensive care unit (MICU) patients. Methods: This was a multicenter randomized controlled trial involving 167 MICU patients with at least one BG measurement +/- 150 mg/dL and one or more of the following: mechanical ventilation, systemic inflammatory response syndrome, trauma, or burns. The interventions were computer-assisted insulin protocol (CAIP), with insulin infusion maintaining BG between 100 and 130 mg/dL; Leuven protocol, with insulin maintaining BG between 80 and 110 mg/dL; or conventional treatment-subcutaneous insulin if glucose > 150 mg/dL. The main efficacy outcome was the mean of patients` median BG, and the safety outcome was the incidence of hypoglycemia (<= 40 mg/dL). Results: The mean of patients` median BG was 125.0, 127.1, and 158.5 mg/dL for CAIP, Leuven, and conventional treatment, respectively (P = .34, CAIP vs Leuven; P < .001, CAIP vs conventional). In CAIP, 12 patients (21.4%) had at least one episode of hypoglycemia vs 24 (41.4%) in Leuven and 2 (3.8%) in conventional treatment (P = .02, CAIP vs Leuven; P = .006, CAIP vs conventional). Conclusions: The CAIP is safer than and as effective as the standard strict protocol for controlling glucose in MICU patients. Hypoglycemia was rare under conventional treatment. However, BG levels were higher than with IV insulin protocols. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
Objectives: To analyze mortality rates of children with severe sepsis and septic shock in relation to time-sensitive fluid resuscitation and treatments received and to define barriers to the implementation of the American College of Critical Care Medicine/Pediatric Advanced Life Support guidelines in a pediatric intensive care unit in a developing country. Methods: Retrospective chart review and prospective analysis of septic shock treatment in a pediatric intensive care unit of a tertiary care teaching hospital. Ninety patients with severe sepsis or septic shock admitted between July 2002 and June 2003 were included in this study. Results: Of the 90 patients, 83% had septic shock and 17% had severe sepsis; 80 patients had preexisting severe chronic diseases. Patients with septic shock who received less than a 20-mL/kg dose of resuscitation fluid in the first hour of treatment had a mortality rate of 73%, whereas patients who received more than a 40-mL/kg dose in the first hour of treatment had a mortality rate of 33% (P < 0.05.) Patients treated less than 30 minutes after diagnosis of severe sepsis and septic shock had a significantly lower mortality rate (40%) than patients treated more than 60 Minutes after diagnosis (P < 0.05). Controlling for the risk of mortality, early fluid resuscitation was associated with a 3-fold reduction in the odds of death (odds ratio, 0.33; 95% confidence interval, 0.13-0.85). The most important barriers to achieve adequate severe sepsis and septic shock treatment were lack of adequate vascular access, lack of recognition of early shock, shortage of health care providers, and nonuse of goals and treatment protocols. Conclusions: The mortality rate was higher for children older than years, for those who received less than 40 mL/kg in the first hour, and for those whose treatment was not initiated in the first 30 Minutes after the diagnosis of septic shock. The acknowledgment of existing barriers to a timely fluid administration and the establishment of objectives to overcome these barriers may lead to a more successful implementation of the American College of Critical Care Medicine guidelines and reduced mortality rates for children with septic shock in the developing world.
Resumo:
The magnitude Of functional impairment that may indicate the threshold between MCI and incipient Alzheimer`s disease (AD) has not been clearly defined. The objective was to examine the pattern of functional impairment in the continuum MCI-AD. Eighty-nine older adults (32 cognitively unimpaired, 31 MCI, and 26 AD patients) were examined with the Brazilian version of the Direct Assessment of Functional Status (DAFS-BR) at a University-based memory clinic. MCI patients were sub-divided according to the progression to AD upon follow-up, and had baseline cognitive, functional and biological variables analyzed. MCI patients displayed mild deficits in functional abilities, with intermediate scores as compared to controls and AD. The DAFS-BR items that differentiated MCI from controls involved the ability to deal with finances and shopping skills. At baseline, scores obtained by MCI patients who converted to AD were not significantly different from scores of nonconverters. The magnitude of functional deficits was associated with AD-like pathological findings in the CSF. In conclusion, MCI patients present with early functional changes in complex, instrumental abilities that require the integrity of memory and executive functions. The objective measurement of the functional state may help identify older adults with increased risk of developing dementia in the MCI-AD continuum. (JINS, 2010, 16, 297-305.)
Resumo:
Premature birth is a well-known risk factor for sensorineural hearing loss in general and auditory neuropathy in particular. However, relatively little is known about the underlying causes, in part because there are so few relevant histopathological studies. Here, we report on the analysis of hair cell loss patterns in 54 temporal bones from premature infants and a control group of 46 bones from full-term infants, all of whom spent time in the neonatal intensive care unit at the Hospital de Nios in San Jose, Costa Rica, between 1977 and 1993. The prevalence of significant hair cell loss was higher in the preterm group than the full-term group (41% vs. 28%, respectively). The most striking finding was the frequency of selective inner hair cell loss, an extremely rare histopathological pattern, in the preterm vs. the full-term babies (27% vs. 3%, respectively). The findings suggest that a common cause of non-genetic auditory neuropathy is selective loss of inner hair cells rather than primary damage to the cochlear nerve.
Resumo:
OBJECTIVES To evaluate the initial results of a prostate cancer screening program using mobile units in Brazil. METHODS Since 2004, we have conducted a program of prostate cancer screening using mobile units across 231 municipalities from 6 Brazilian states. RESULTS A total of 17 571 men were evaluated by clinical history, digital rectal examination (DRE), and serum free and total prostate-specific antigen (PSA) levels. The recommendations for biopsy were a PSA level of >= 4.0 ng/mL, DRE findings suspicious for cancer, or a PSA level of 2.5-4.0 ng/mL with a percent-free PSA level <15%. The biopsy protocol included 12 biopsy cores from the peripheral zone, 2 from the transition zone, and additional sampling of suspicious areas. The cumulative cancer detection rate was 3.7%. The main indication for biopsy was a PSA level of >= 4.0 ng/mL (51.2%), with a positive predictive value (PPV) of 44.1%. Another 19.7% of biopsied men had suspicious DRE findings with a normal PSA level (PPV 23.5%). A percent-free PSA level of <15% in men with a PSA level of 2.5-4.0 ng/mL and normal DRE findings yielded a PPV of 31.1%. The PPV was greater (70.9%) for the 7.1% of men with both suspicious DRE findings and a PSA level of >4.0 ng/mL. Most cancers were Stage T1-T2 (93.4%), and the percentage of Gleason score of >= 7 was 32.5%. The proportion of insignificant cancers according to Epstein`s criteria was 13.5%. CONCLUSIONS A mobile prostate cancer screening unit enabled an underserved population to gain access to specialized care through the public healthcare system. The cancer detection rate in this population was similar to those from international studies. UROLOGY 76: 1052-1057, 2010. (C) 2010 Published by Elsevier Inc.
Resumo:
OBJECTIVE To evaluate the effect of the environment and the observer on the measurement of blood pressure (BP) as well as to compare home BP (HBP) and ambulatory BP (ABP) measurements in the diagnosis of white coat hypertension (WCH) and masked hypertension (MH) in children and adolescents with hypertension (HT). METHODS BP of 40 patients with HT (75% of which had secondary HT and were on antihypertensive medication), mean age 12.1 years was evaluated through casual measurements at the clinic and at the HT unit, HBP for 14 days with the OMRON HEM 705 CP monitor (Omron, Tokyo, Japan) and ABP performed with SPACELABS 90207 (Spacelabs, Redmond, WA), for 24 h. RESULTS HT was diagnosed at the doctor`s office by ABP and HBP in 30/40, 27/40, and 31/40 patients, respectively. Based on office BP and ABP, 60% of patients were normotensive, 17.5% HT, 7.5% had WCH, and 15% had MH, whereas based on office BP and HBP 65, 12.5, 10, and 12.5% of patients were classified according to these diagnoses, respectively. There was considerable diagnostic agreement of HT by ABP and HBP (McNemar test, P < 0.01) (kappa = 0.56). CONCLUSION In hypertensive children and adolescents, HBP and ABP present comparable results. HBP appears to be a useful diagnostic test for the detection of MH and WCH in pediatric patients.